df/dt (ROCOF) Relay Testing: How to Test Rate-of-Change-of-Frequency Protection with an Automatic Relay Test Kit
KPM ENGINEERING SOLUTIONS · TECHNICAL BLOG df/dt protection, also called ROCOF (rate of change of frequency) protection or ANSI 81R, is one of the fastest-acting frequency protections in a power system. It is widely used for load shedding, generator protection and loss-of-mains (islanding) protection at solar, wind and captive power plants. It is also one of the harder functions to test, because a static injection cannot prove it: the relay must see the frequency actually c
Akshit Dharwala
Nov 511 min read


Why Does a Transformer Differential Relay Trip Without an Internal Fault?
KPM ENGINEERING SOLUTIONS · TECHNICAL NOTE 14 causes of false 87T trips — commissioning-stage errors and in-service effects — and the test that proves or rules out each one Part A — Commissioning stage Part B — In service A1 Wrong CT ratio or ratio compensation B1 Magnetizing inrush A2 Reversed CT polarity or crossed phases B2 CT saturation during an external fault A3 Wrong vector-group compensation B3 CT remanence A4 Zero-sequence current not eliminated B4 Overexcitation A
KPM Tech Team
Oct 2617 min read


5% or 10%? What the Error Curve on Your CT Analyzer Really Tells You
What the Error Curve on Your CT Analyzer Really Tells You
KPM Tech Team
Oct 126 min read


Unlocking the Secrets of Vacuum Interrupter Testing
Vacuum Interrupter Testing
A vacuum interrupter tester works by applying a high DC voltage across the interrupter's open contacts to check for a loss of vacuum or other defects. A good vacuum interrupter will have high dielectric strength, preventing a flashover or excessive leakage current, indicated by a green light. If the interrupter is defective and the vacuum is poor, the tester will detect a flashover or high leakage current and indicate a failure .
KPM Tech Team
Nov 23, 20253 min read


Understanding the Importance of Shorting Secondary Windings in Current Transformer Testing
When testing a current transformer (CT) , it is crucial to short the secondary windings of the other CT cores not under test. This practice is essential for safety and accuracy reasons . Below is a comprehensive breakdown of this procedure. KPM CT PT Analyzer at manufacturer's facility 1. Prevent Dangerous High Voltages (During Primary Current Injection Method) A current transformer behaves like a step-up voltage transformer when its secondary is open. If a CT secondary is
KPM Tech Team
Sep 24, 20252 min read


Achieving Perfect Accuracy: How CT Analyzers Can Mimic Primary Injection Results
Generator Bus Duct CT Testing using KPM CT/PT Analyzer. In the world of electrical engineering, Current Transformers (CTs) are critical...
KPM Tech Team
Jan 23, 20255 min read


Understanding Partial Discharge Measurements & their significance.
Figure 1 - KPM Penta PD with its 5 sensor technology. What is Partial Discharge? PD Definitions according to IEC 60270 “Localized...
KPM Tech Team
Jul 18, 20243 min read


Which relay test kit suits me ? Which points to consider while selecting a model of a relay test kit ?
Which relay test kit is the best for me ? How Important is the application support for selecting a make and model of a relay test kit ?
KPM Tech Team
Jun 3, 20244 min read


"The Essential Guide to Choosing Substation Testing Equipment"
Selecting substation testing equipment is crucial for ensuring the safety, reliability, and efficiency of electrical power systems. Here...
KPM Tech Team
May 28, 20242 min read


What are the most common tests performed on power transformer oil by power utilities.
Power utilities employ a range of tests to assess the condition of transformer oil, ensuring the reliability and longevity of power...
KPM Tech Team
May 28, 20243 min read


Comparing the Effectiveness of Tan Delta Test at 10kV and Oil Tan Delta Testing: Which is More Useful?
Detailed Comparison of Oil Tan Delta Testing and General Tan Delta Testing at 10kV for Power Transformers Oil Tan Delta Testing Purpose:...
KPM Tech Team
May 20, 20243 min read


Which PD measurement method is the best and in which conditions?
Introduction: Partial discharge is a phenomenon that occurs in electrical insulation systems when localized breakdowns or discharges...
KPM Tech Team
Jan 23, 20244 min read


Decoding - Power Transformer Bushing CT Testing using KPM CT PT Analyzer
Bushing CT Testing using KPM CT PT Analyzer
KPM Tech Team
Jun 25, 20232 min read


Why only few types of tan delta kits can perform in charged EHV Switchyards ?
Performing tan delta testing in charged switchyards presents unique challenges and safety concerns due to the presence of high voltages...
KPM Tech Team
Jun 25, 20233 min read


What is Dissolved Gas Analysis & Why DGA is conducted ?
Dissolved Gas Analysis (DGA) is a diagnostic technique used in laboratories to assess the condition of transformer oil. Transformers are...
KPM Tech Team
Jun 21, 20232 min read


DC Testing Methods
DC Testing Methods | Insulation Resistance Testing | High-potential (Hi-pot) voltage testing
KPM Tech Team
Jul 2, 20213 min read


What is principle of tan delta? What are its various Modes.
What is the Tan Delta Test? A pure insulator when is connected across line and earth behaves as a capacitor. In an ideal insulator, as...
KPM Tech Team
Jun 1, 20214 min read


What is Lightning Arrester Testing? When to test a LA & How to perform the test?
Surge Arresters ( Lightning Arresters ) are the protective devices for limiting the surge voltages on the equipments / power distribution...
KPM Tech Team
Apr 9, 20212 min read


What is Current Transformer? Explain its principle & key parameters
Principle of operation of CT A current transformer is defined as “as an instrument transformer in which the secondary current is...
KPM Tech Team
Apr 9, 20215 min read


What are relays & what are the type of relays?
What is Relay: A relay is automatic device which senses an abnormal condition of electrical circuit and closes its contacts. These...
KPM Tech Team
Apr 9, 202118 min read
Disclaimer - The informations provided in these blogs are for general informational purposes only. While we strive to ensure the accuracy and completeness of the content, we make no guarantees regarding its correctness, reliability, or currentness. The content is provided "as is," and any reliance you place on such information is strictly at your own risk. We are not responsible for any errors, omissions, or any outcomes related to the use of this information. Always seek professional advice or verification before making decisions based on the content of this blog.