top of page

CT & PT TESTING KITS 

CT/PT Analyzer C+

KPM CTA C+.png
  • Designed for comprehensive testing of all types of CT/PT including magnetization characteristics, saturation behavior, transformation ratio, polarity, burden, and winding resistance.

  • Optional external booster provides 0–200 A AC output for Primary Current Injection with high testing accuracy and reliable performance.

  • Suitable for laboratories, transformer manufacturing units, testing facilities, and 220 kV, 400 kV, and 765 kV live switchyards.

  • Widely used in power utilities, substations, industrial power systems, and electrical maintenance applications for accurate diagnostics and efficient testing.

Automatic PIK ( KPM APIK 2000 )

KPM APIK 2000.png
  • KPM-APIK Series Automatic Primary Current Injection Tester is designed for high-voltage switch testing, protection system testing, and Current Transformer (CT) testing in power systems.

  • Generates high current to simulate rated or fault current conditions for accurate testing of primary circuits and electrical protection equipment.

  • Measures impedance voltage, power factor, resistance, active/reactive power, and provides precise data through primary voltage and current sampling.

  • Suitable for Primary Current Injection testing, CT/PT primary & secondary measurement, Circuit Breaker I/T Curve testing, polarity testing, operation time analysis, and temperature rise testing.

CT/PT Pro 

KPM CT PT Pro
  • KPM-CT/PT Pro is an automatic testing device designed for accurate testing of instrument transformers through primary current injection.

  • Capable of performing CT/PT tests including Turns Ratio, Ratio Error, Phase Error, Excitation Curve Plotting (up to 2 kV), Polarity, Winding Resistance, and CT Secondary Burden.

  • Automatically completes testing procedures and generates detailed reports for faster and more efficient transformer diagnostics.

  • Equipped with built-in flash RAM to prevent data loss during power failure, ensuring reliable operation in laboratories, substations, and industrial power systems.

CT HEAT RUN TEST DEVICE 

KPM CTTC .png
  • Current transformer heat run test device first measures the impedance value of the connected current transformer sample loop, and then automatically controls the output current of the device to the target test current value according to the impedance value and the set test current value. 

  • It ​measures the primary loop impedance of the connected sample current transformer, and adjusts the device's electric voltage regulator to the target value according to the measured impedance value, and then generates the required target test current in the booster output loop. 

  • It records the amplitude-time curve of the sample primary loop current, primary loop voltage, device regulator output voltage, device regulator output current, etc. during the test. It automatically controls and monitors the entire test process to protect against abnormal and erroneous operations during the test.

CT/PT Analyzer 

KPM CT PT Analyzer.png
  • Designed for CT/PT manufacturers and utility customers for accurate transformer testing in 220 kV, 400 kV, and 765 kV live switchyards.

  • Advanced Multi Tap Testing feature allows testing of all secondary winding ratios in a single operation, reducing testing time.

  • Widely used in power utilities, substations, renewable energy plants, railways, and industrial power systems.

  • Ensures reliable diagnostics, high accuracy, faster testing, and efficient power system performance.

Primary Current Injection Kit

KPM PIK1000.png
  • KPM Series Primary Current Injection Test Set is specially designed for high current simulation and testing applications in industrial and power sector environments.

  • Used for testing Current Transformers (CTs), Circuit Breakers, switchgear equipment, and other high-current electrical systems with reliable performance.

  • Features stable current rise, wide load variation range, reliable functionality, and easy & safe operation for efficient field and laboratory testing.

  • Ideal for temperature rise testing, maintenance, diagnostics, and performance evaluation of various electrical and power equipment.

HVCTR ( HV CT Ratio Tester)

KPM HVCTR.png
  • It is the High Voltage Current Transformer Ratio Tester. It is an innovative product to measure Key line / CT parameters of up to 33KV systems. 

  • KPM-HVCTR is used for the determination of Primary & Secondary Current Measurement, Current Transformation Ratio, Phase Sequence and Polarity.

  • It has 3 units 1) High Voltage Clamp is used with the Hot Stick to clamp the primary of current transformer. It transmits the wireless signal to the monitor.

  • 2) Three-Channel Low-voltage Secondary Current Clamps are available for determination of secondary current of CT. 

  • 3) Monitor is used to display the various results with storage of 99 readings which receives the primary signal through the wireless transmitter.

Comparison - CT PT Analyzer & CT PT Pro 

KPM CT PT Testers

Video - CT/PT Analyzer

CT/PT Videos

KPM CT PT Testing Videos

KPM CT PT Testing Videos

KPM CT PT Testing Videos
Unboxing LA Tester , KPM LA 103+

Unboxing LA Tester , KPM LA 103+

03:45
KPM TAN DELTA - 12 KV (https://www.kpmtek.com/tandelta)

KPM TAN DELTA - 12 KV (https://www.kpmtek.com/tandelta)

01:27
UNBOXING RELAY TEST KIT - KINGSINE K3063I

UNBOXING RELAY TEST KIT - KINGSINE K3063I

05:50
Testing Tan Delta in 765kV Live Switchyard

Testing Tan Delta in 765kV Live Switchyard

00:43

Theory - CT/PT Testing

CT PT Theory
KPM CT_PT Analyzer ,  Generator Busduct

CT (Current Transformer) – Theory

Like any other transformer, a current transformer has a primary winding, a magnetic core, and a secondary winding. The alternating current flowing in the primary produces an alternating magnetic field in the core, which then induces an alternating current in the secondary winding circuit. An essential objective of current transformer design is to ensure that the primary and secondary circuits are efficiently coupled, so that the secondary current bears an accurate relationship to the primary current.

 

 

PT (Potential Transformer) – Theory

A Voltage Transformer theory or Potential Transformer theory is just like theory of general purpose step down transformer. Primary of this transformer is connected across the phases or and ground depending upon the requirement. Just like the transformer, used for stepping down purpose, potential transformer i.e. PT has lower turns winding at its secondary. The system voltage is applied across the terminals of primary winding of that transformer, and then proportionate secondary voltage appears across the secondary terminals of the PT.

CT/PT Testing

Below is the list of Major tests conducted on CT & PT

  • Insulation Resistance Test

  • Polarity Test

  • Secondary/Loop Resistance Test

  • Burden Test (optional test)

  • Magnetization Curve Test (optional test)

  • Hysteresis Curve Test

  • Turns Ratio Test (optional test)

  • Primary Injection Test

  • High Voltage Test

Frequently Asked Questions ( FAQ )  

FAQ - CT PT Analyzer

FAQ about all our CT/PT products :

  • 01
  • 02
  • 03
  • 04
  • 05
  • 06
  • 07
  • 08
  • 09
  • 10
  • 11
  • 12
  • 13
bottom of page