- KPM Transformer Oil Testing | Oil Analysis & Diagnostics|Transformer Oil Testing
Advanced transformer oil testing by KPM for precise oil analysis, insulation assessment, and efficient transformer maintenance. EQUIPO DE LABORATORIO DE PRUEBA DE ACEITE PROBADOR DEL PUNTO DE INFLAMACIÓN (KPM OT 01) Ver más El probador de punto de inflamación de aceite de transformador de copa cerrada KPM OT 01 es un probador automático de punto de inflamación cerrado. Se utiliza para medir el punto de inflamación abierto y cerrado de productos derivados del petróleo. Parámetros técnicos-: 1. Medición de temperatura Rango de medición de temperatura: -59,9 °C~299,9 °C Rango de control de temperatura: temperatura ambiente ~ 300 ° C Repetibilidad: 0.025X (x = valor promedio de prueba dos veces sucesivas) Resolución: 0.1°C Precisión: 0,5% Sensor de temperatura: resistencia de platino (PT100) Sensor de fuego relámpago: anillo de detección de iones 2. Temperatura ambiente: 0 ~ 40 °C 3. Humedad relativa: ≤ 85 % de humedad relativa 4. Fuente de alimentación: AC220V ± 20%; 50Hz ± 10% 5. Consumo de energía: aproximadamente 400W PROBADOR DEL PUNTO DE INFLAMACIÓN (KPM OT 01) Ver más El probador de punto de inflamación de aceite de transformador de copa cerrada KPM OT 01 es un probador automático de punto de inflamación cerrado. Se utiliza para medir el punto de inflamación abierto y cerrado de productos derivados del petróleo. Parámetros técnicos-: 1. Medición de temperatura Rango de medición de temperatura: -59,9 °C~299,9 °C Rango de control de temperatura: temperatura ambiente ~ 300 ° C Repetibilidad: 0.025X (x = valor promedio de prueba dos veces sucesivas) Resolución: 0.1°C Precisión: 0,5% Sensor de temperatura: resistencia de platino (PT100) Sensor de fuego relámpago: anillo de detección de iones 2. Temperatura ambiente: 0 ~ 40 °C 3. Humedad relativa: ≤ 85 % de humedad relativa 4. Fuente de alimentación: AC220V ± 20%; 50Hz ± 10% 5. Consumo de energía: aproximadamente 400W PROBADOR DE VISCOSIDAD (KPM OT O3) Ver más La viscosidad cinemática es la medida de la fuerza de fricción interna cuando el líquido fluye bajo la acción de la gravedad, y su valor es la relación entre la viscosidad dinámica y la densidad a la misma temperatura, que es una de las propiedades físicas y químicas importantes de identificación del grado y la calidad del aceite. En la aplicación práctica, la selección adecuada de la viscosidad del aceite lubricante puede garantizar el funcionamiento normal y fiable de los equipos mecánicos. KPM OT 03 es el equipo de prueba especial diseñado y fabricado en base a las normas nacionales/normas internacionales. KPM OT 03 es adecuado para la determinación de la viscosidad cinemática de productos petrolíferos líquidos. El instrumento tiene una función de temporizador del tiempo de movimiento de la muestra y una función de cálculo automático de los resultados finales de la viscosidad cinemática. Características del instrumento probador de viscosidad cinemática ◆La constante del viscosímetro, el valor de control de temperatura, la temperatura de ajuste fino, el número de pruebas y otros parámetros se pueden configurar mediante el teclado, el instrumento tiene una función de memoria para guardar el conjunto de datos automáticamente la primera vez ◆Adoptar sensor importado y nueva tecnología de control de temperatura de ajuste automático PID digital, que tiene un amplio rango de control de temperatura y alta precisión de control de temperatura ◆El reloj calendario no se apaga y muestra la hora actual automáticamente cuando se inicia ◆Función alternativa de comunicación en red, control remoto, tabulación ◆Botón sin marcas, el funcionamiento es intuitivo y sencillo. ◆El número de tiempo de experimento es de 1 a 6 veces, lo cual es ajustable y conveniente ◆El registro experimental se puede guardar para verlo más tarde. Probador de viscosidad cinemática Parámetros técnicos ◆ Agujero de baño líquido: 4 agujeros ◆Rango de control de temperatura: temperatura ambiente —120 ℃ ◆ Precisión de control de temperatura: ≤ ± 0,01 ℃ ◆Potencia de calefacción: 1000W ◆Tiempos de prueba: 1 a 6 veces, ajustable TAN DELTA DE ACEITE ( KPM OTD 01 ) Ver más KPM OTD01 is used for measuring dielectric dissipation_cc781905 -5cde-3194-bb3b-136bad5cf58d_factor and DC resistivity of insulating oil_cc781905 -5cde-3194-bb3b-136bad5cf58d_and other aislantes líquidos._cc781905-5cde-3194-bb3b5cf-1586d_bad KPM OTD01 en un probador de resistividad y pérdida dieléctrica de aceite aislante de limpieza automática 1.Oil cup is cleaned automatically and_cc781905-5cde-3194-bb3b- 136bad5cf58d_has electrode calibración función._cc781905-5cde-31936-bad3bcf-5 2. Internal standard capacitor electrode type_cc781905-5cde-3194-bb3b- 136bad5cf58d_condensador,con electrode spacing 2mm. 3.Large-screen LCD,backlight, display is clear._cc781905-5cde-3194-bb3b- 136malo5cf58d_ 4.More accurate. Testing AC power supply_cc781905-5cde-3194- bb3b-136bad5cf58d_adopts AC - DC -_cc781905-5cde-3194 -bb3b-136bad5cf58d_AC conversion method. 5.Equipped with overvoltage, overcurrent and limit_cc781905-5cde-3194- bb3b-136bad5cf58d_ protecciones. 6.Measured temperature and system clock. _cc781905-5cde-3194- bb3b-136bad5cf58d_ Technical Parámetros Alimentación Voltage : AC 220V±10% Potencia Frecuencia: 50Hz/60Hz ±1% Medición Rangecapacitancia: 5pF~200pF relativa permitividad: 1.000~30.000 dielectric dissipation factor : 0.00001~100 DC Resistividad: 2,5 MΩm~20 TΩm Medición Capacidad de precisión: ±(1 % de lectura+0,5 pF) relativa permitividad: ±1% lectura dielectric dissipation factor : ±(1% reading +0.0001) DC Resistividad: ±10 % lectura Resolution Relación de capacitancia: 0.01pF relativo permitividad: 0,001 dielectric dissipation factor : 0.00001 Temperatura Rango: 0~125℃ Thermometric Error: ±0,5 ℃ AC testing voltage : 500 ~ 2200V adjustable,_cc781905-5cde- 3194-bb3b-136bad5cf58d_frequency 50 HZ DC testing voltage : 0 ~ 500V adjustable Potencia Disipación: 100w Límite Dimensión: 500 mm * 360 mm * 420 mm Peso : 22kg PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DEL PUNTO DE INFLAMACIÓN (KPM OT 01) Ver más El probador de punto de inflamación de aceite de transformador de copa cerrada KPM OT 01 es un probador automático de punto de inflamación cerrado. Se utiliza para medir el punto de inflamación abierto y cerrado de productos derivados del petróleo. Parámetros técnicos-: 1. Medición de temperatura Rango de medición de temperatura: -59,9 °C~299,9 °C Rango de control de temperatura: temperatura ambiente ~ 300 ° C Repetibilidad: 0.025X (x = valor promedio de prueba dos veces sucesivas) Resolución: 0.1°C Precisión: 0,5% Sensor de temperatura: resistencia de platino (PT100) Sensor de fuego relámpago: anillo de detección de iones 2. Temperatura ambiente: 0 ~ 40 °C 3. Humedad relativa: ≤ 85 % de humedad relativa 4. Fuente de alimentación: AC220V ± 20%; 50Hz ± 10% 5. Consumo de energía: aproximadamente 400W KARL FISCHER (KPM OT 02) Ver más Valorador Karl Fischer KPM OT 02 is suitable in determining water content in_cc781905-5cde-3194- bb3b-136bad5cf58d_the liquid petroleum products by titration using_cc781905- 5cde-3194-bb3b-136bad5cf58d_Karl Fischer reagent. It adopts a microprocessor for control, so_cc781905-5cde- 3194-bb3b-136bad5cf58d_it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It_cc781905-5cde-3194- bb3b-136bad5cf58d_also has function of self-diagnostics, menu_cc781905-5cde- 3194-bb3b-136bad5cf58d_selection. It is a multifunctional, convenient, and automatic analysis_cc781905-5cde-3194-bb3b5-cf58d_instrumento. Titulador volumétrico de humedad Karl Fischer Technical parameters: 1 Method Karl Fischer Coulometric Titrator_cc781905-5cde-3194-bb3b- 136bad5cf58d_Principio 2 Tipo Portátil 3 Medición Range 0ug-100mg 4 Resolución 0.1ug 5 the Largest Electrolytic Speed 40_cc781905-5cde-3194-bb3b- 136bad5cf58d_ug/s 6 Power Supply Voltage AC220V ±20%(_cc781905-5cde -3194-bb3b-136bad5cf58d_personalización) 7 Mayor power 30w 8 Work Temperature 10~35℃ 9 Trabajo Humedad ≤85 % 10 Dimensiones 320*240*150mm 11 Peso 5kg TAN DELTA DE ACEITE ( KPM OTD 01 ) Ver más KPM OTD01 is used for measuring dielectric dissipation_cc781905 -5cde-3194-bb3b-136bad5cf58d_factor and DC resistivity of insulating oil_cc781905 -5cde-3194-bb3b-136bad5cf58d_and other aislantes líquidos._cc781905-5cde-3194-bb3b5cf-1586d_bad KPM OTD01 en un probador de resistividad y pérdida dieléctrica de aceite aislante de limpieza automática 1.Oil cup is cleaned automatically and_cc781905-5cde-3194-bb3b- 136bad5cf58d_has electrode calibración función._cc781905-5cde-31936-bad3bcf-5 2. Internal standard capacitor electrode type_cc781905-5cde-3194-bb3b- 136bad5cf58d_condensador,con electrode spacing 2mm. 3.Large-screen LCD,backlight, display is clear._cc781905-5cde-3194-bb3b- 136malo5cf58d_ 4.More accurate. Testing AC power supply_cc781905-5cde-3194- bb3b-136bad5cf58d_adopts AC - DC -_cc781905-5cde-3194 -bb3b-136bad5cf58d_AC conversion method. 5.Equipped with overvoltage, overcurrent and limit_cc781905-5cde-3194- bb3b-136bad5cf58d_ protecciones. 6.Measured temperature and system clock. _cc781905-5cde-3194- bb3b-136bad5cf58d_ Technical Parámetros Alimentación Voltage : AC 220V±10% Potencia Frecuencia: 50Hz/60Hz ±1% Medición Rangecapacitancia: 5pF~200pF relativa permitividad: 1.000~30.000 dielectric dissipation factor : 0.00001~100 DC Resistividad: 2,5 MΩm~20 TΩm Medición Capacidad de precisión: ±(1 % de lectura+0,5 pF) relativa permitividad: ±1% lectura dielectric dissipation factor : ±(1% reading +0.0001) DC Resistividad: ±10 % lectura Resolution Relación de capacitancia: 0.01pF relativo permitividad: 0,001 dielectric dissipation factor : 0.00001 Temperatura Rango: 0~125℃ Thermometric Error: ±0,5 ℃ AC testing voltage : 500 ~ 2200V adjustable,_cc781905-5cde- 3194-bb3b-136bad5cf58d_frequency 50 HZ DC testing voltage : 0 ~ 500V adjustable Potencia Disipación: 100w Límite Dimensión: 500 mm * 360 mm * 420 mm Peso : 22kg PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W Kit de prueba de aceite BDV (OBD 100A+) Ver más Como sugiere el nombre, el equipo de prueba Oil BDV (KPM-OBD100A+) se utiliza para medir la resistencia a la ruptura del aceite aislante. Capaz de generar 80/100 KV con impresora integrada. Agitador motorizado y programado Peso ligero 0.5KV/sec to 5KV/sec variable voltage rise as per ASTM Standards ( available in "A+"_cc781905-5cde-3194-bb3b- 136bad5cf58d_ modelos) Kit de prueba de aceite BDV (OBD 100+) Ver más Como sugiere el nombre, el juego de prueba Oil BDV (KPM-OBD 100+) se utiliza para medir la resistencia a la ruptura del aceite aislante. Capaz de generar 80/100 KV con impresora integrada. Agitador motorizado y programado Peso ligero Aumento de voltaje de 2 KV/s con planes de prueba automáticos según IEC e IS Preguntas frecuentes (FAQ) FAQ about Oil testing : 01 How to Perform a Reliable 10kV Insulation Test? A 10kV insulation resistance test is used to evaluate the dielectric strength of high-voltage equipment like transformers, motors, and cables. To perform it reliably, first de-energize and isolate the equipment, ensuring it's properly grounded. Clean terminals to remove surface contamination. Connect the insulation tester leads: One to the conductor and the other to ground. Select the 10kV test voltage on the insulation resistance tester. Begin the test and monitor resistance for 1 to 10 minutes—longer durations help identify moisture or insulation defects. Readings should be in the GΩ (giga ohm) range for healthy insulation. Apply DAR (Dielectric Absorption Ratio) or PI (Polarization Index) analysis to assess insulation aging. Ensure environmental conditions are dry and free of electrical noise for accuracy. KPM provides high-voltage insulation testers with digital displays, timer functions, and built-in safety features, ensuring accurate, safe, and standards-compliant insulation testing across utility and industrial applications. 02 Differences Between 5kV, 10kV, and 15kV Insulation Testers? The main difference between 5kV, 10kV, and 15kV insulation testers lies in their test voltage output, which determines the type of equipment they are suited for and the depth of insulation assessment they provide. 5kV testers are typically used for low to medium voltage equipment like motors, cables, and switchgear up to 25kV. 10kV testers are suitable for higher-voltage systems such as power transformers, HV motors, and cables rated up to 69kV, providing a deeper insulation profile. 15kV testers are used for critical high-voltage assets above 69kV, enabling detection of insulation weaknesses that lower voltages may miss. Higher voltage testers stress insulation more, revealing latent defects and moisture absorption. However, using too high a voltage on low-rated equipment can cause damage. KPM offers 5kV, 10kV, and 15kV insulation testers with digital readings, polarization index (PI), and DAR calculations, ideal for field diagnostics and predictive maintenance. 03 What is Karl Fischer Titration ? Explain Moisture Testing in Oil. Karl Fischer (KF) titration is a precise chemical method used to measure moisture content (water) in substances, including insulating oils, with accuracy down to parts per million (ppm). It's the preferred method for transformer oil and lubricants because even trace moisture can degrade dielectric strength, cause corrosion, or affect equipment performance. How It Works: KF titration is based on a chemical reaction where iodine reacts with water in the presence of sulfur dioxide and alcohol, using a base (often imidazole or pyridine) as a catalyst: This reaction occurs until all water is consumed. The amount of iodine used is directly proportional to the moisture present. Types of KF Titration: Volumetric KF: For water content above 1%. Common in oil testing. Coulometric KF: For ultra-low moisture (<1%), generating iodine electrochemically. Advantages: Highly accurate (1–10 ppm range). Specific to water (no interference from other volatiles). Widely accepted in ASTM D1533 for transformer oil testing. KPM supplies Karl Fischer titrators for both volumetric and coulometric methods, used in power utilities and oil testing labs to ensure insulation oils remain within safe moisture limits. 04 How to Identify Oil Contamination Using BDV Testers? Breakdown Voltage (BDV) testing is a key method to identify contamination in insulating oils used in transformers, circuit breakers, and other high-voltage equipment. A BDV tester applies a gradually increasing AC voltage to a sample of insulating oil placed between two standard electrodes. Clean, dry oil has high dielectric strength and resists electrical breakdown. However, the presence of moisture, dissolved gases, carbon particles, or sludge lowers the breakdown voltage significantly. Typically, good transformer oil should withstand 30 kV or more in a 2.5 mm electrode gap. A low BDV reading (e.g., below 20 kV) suggests contamination. Multiple test cycles (usually 5–6) help eliminate anomalies and confirm consistency. KPM provides automated and manual BDV testers with features like automatic voltage ramping, stirrers for even testing, digital displays, and built-in standards (IEC 60156, ASTM D1816), ensuring accurate detection of oil contamination and timely maintenance planning. 05 What is Viscosity and Pour Point in Transformer Oils? Viscosity is the measure of a fluid's resistance to flow. In transformer oils, optimal viscosity is crucial for: Heat transfer: Low viscosity allows better circulation and cooling. Lubrication: Protects internal parts from wear. Pump efficiency: Thinner oil reduces mechanical stress on pumps. High viscosity at low temperatures can hinder oil movement, reducing cooling and increasing risk of overheating. Transformer oils typically have a viscosity range of 8–12 cSt at 40°C, as per IEC and ASTM standards. Pour Point: Pour point is the lowest temperature at which oil still flows. It indicates how oil behaves in cold environments. A low pour point ensures the oil remains pumpable and circulates properly during cold starts or winter operation. A good transformer oil has a pour point below -30°C, as per ASTM D97 or ISO 3016. KPM provides viscosity and pour point testing kits and services compliant with ASTM D445 and D97, ensuring transformer oil meets safety and performance standards. 06 What is Flash Point Testing? What are its Safety Standards and Applications? Flash point testing determines the lowest temperature at which a liquid emits enough vapor to ignite in the presence of an ignition source. It is a critical parameter for assessing the fire and explosion risk of flammable and combustible liquids such as fuels, lubricants, and transformer oils. This test ensures the safe handling, storage, and transportation of these substances. Globally recognized standards such as ASTM D93 (Pensky-Martens Closed Cup), ISO 2719, and ASTM D56 (Tag Closed Tester) provide standardized methods to ensure consistency and safety. Applications span industries like petrochemicals, energy, pharmaceuticals, and aviation, where accurate flash point data is essential for risk assessments, regulatory compliance, and material classification. KPM ensures strict adherence to international safety standards by offering flash point testers that comply with ASTM D93, ISO 2719, and related norms. KPM’s equipment features precision temperature control, sealed test chambers, and automation to eliminate user error. These instruments are calibrated and validated regularly to maintain measurement integrity. Additionally, KPM provides comprehensive support, including training and servicing, to ensure customers conduct testing safely and accurately. By aligning with global testing protocols, KPM plays a key role in advancing operational safety and regulatory compliance across 07 What is Oil Tan Delta? Also understanding Dielectric Loss. Tan Delta, also known as the dissipation factor, is a key parameter used to evaluate the dielectric loss in insulating oils. It represents the ratio of the resistive current to the capacitive current within the oil when subjected to an alternating electrical field. It measures the inefficiency or energy loss in the insulation system when subjected to an alternating electric field. A low Tan Delta value indicates good insulation quality with minimal dielectric loss, while a high value suggests aging, moisture contamination, or deterioration of the insulating oil. Tan delta testing is a crucial diagnostic tool for assessing the health of insulating oil. By understanding the relationship between tan delta, dielectric loss, and the condition of the oil, maintenance professionals can take steps to ensure the reliable and safe operation of electrical equipment. KPM offers advanced Tan Delta testing instruments that comply with IEC and ASTM standards. These kits provide accurate, real-time results with user-friendly operation and robust design. KPM also offers expert support, calibration, and on-site testing services to help utilities maintain insulation health effectively. 08 What are the Best Practices in Oil Sampling and Analysis? Accurate oil sampling and analysis are vital for assessing the condition of insulating oils used in transformers and other high-voltage equipment. Key best practices include taking samples from the correct location (ideally turbulent flow areas, upstream of filters, and not from drain plugs), at the right time (when the machine is running and under normal load), and with proper techniques (using clean equipment, avoiding contamination, and labeling samples accurately). Best practices include taking samples from live equipment using clean, dry, and airtight glass or metal containers to avoid contamination. Sampling should be done from designated sampling valves, ideally after allowing sufficient oil flow to flush impurities. Samples must be labeled clearly with details like equipment ID, location, date, and temperature. Proper analysis involves tests for moisture content, dielectric strength, acidity, interfacial tension, Tan Delta, and dissolved gas analysis (DGA), offering insights into oil aging, contamination, and equipment health. KPM provides a full range of oil testing instruments, including BDV testers, moisture analyzers (Karl Fischer), and Tan Delta kits, all adhering to IEC/ASTM standards. KPM also offers oil sampling kits, training, and onsite testing services, ensuring reliable diagnostics and extending asset life. 09 How to Interpret Insulation Resistance Test Results? Insulation resistance (IR) testing assesses the quality of insulation in electrical equipment by measuring its resistance to current flow. IR testing helps detect insulation weaknesses before they lead to equipment failure, short circuits, or electrical shocks. The test measures the resistance between conductors (e.g., wires) or between a conductor and ground, indicating how well the insulation is preventing current leakage. Interpreting these results involves understanding the expected values, identifying trends, and recognizing factors that can affect the readings. A high insulation resistance (in the megaohms or higher) generally indicates good insulation, while low readings suggest potential problems like moisture, contamination, or damage.. It is typically conducted using a megohmmeter at voltages like 500V, 1kV, or 5kV. Higher resistance values (in megaohms or gigaohms) indicate good insulation, while lower values suggest moisture ingress, dirt, or insulation deterioration. Acceptable IR values vary by equipment type, but a general rule is 1 MΩ per kV of operating voltage, with time-based readings (1 min, 10 min) used to calculate the polarization index (PI). A PI > 2 indicates good insulation; < 1.5 may signal problems. KPM offers reliable insulation resistance testers with digital displays, automatic PI/ DAR calculation, and high-voltage test capabilities (up to 20kV). Compliant with IEC and IEEE standards, KPM’s instruments ensure precise diagnosis. KPM also provides training and expert support to help customers accurately interpret IR results for preventive maintenance and asset safety. 10 What is Electrical Oil Testing According to ASTM/IEC Standards? Electrical insulating oils play a critical role in cooling and insulating transformers, circuit breakers, and other high-voltage equipment. Electrical oil testing, particularly for transformer oil, is crucial for assessing its performance and detecting potential issues. Various ASTM and IEC standards govern these tests, ensuring consistent and reliable results. These standards cover a range of properties like dielectric breakdown voltage, acidity, moisture content, and more. Key ASTM and IEC Standards for Electrical Oil Testing: 1. Dielectric Breakdown Voltage: IEC 60156: Specifies the method for determining the dielectric breakdown voltage of insulating liquids at power frequency. This test is vital for assessing the oil's ability to withstand electrical stress. ASTM D877: Another standard for determining dielectric breakdown voltage, using disk electrodes. ASTM D1816: Uses VDE electrodes for the same purpose. 2. Moisture Content: IEC 60814: Specifies the method for determining the water content in insulating liquids. 3. Acidity (Neutralization Value): IEC 62021-1: Provides the standard for determining the acidity of insulating liquids. 4. Dissolved Gas Analysis (DGA): While not explicitly mentioned in the provided context, DGA is a crucial test for identifying potential problems like overheating or arcing within a transformer. 5. Other Important Tests: IEC 60422: Covers various aspects of insulating oil, including appearance, color rating, and sludge content. ASTM D1500: Specifies the method for determining the color of petroleum products. Interfacial Tension (ASTM D971): Indicates the presence of soluble contaminants. Resistivity (IEC 60247): Measures the oil's ability to resist electrical current flow. Dissipation Factor (IEC 60247): Indicates the energy loss in the oil due to dielectric losses. Flash Point (ASTM D92, ASTM D93): Determines the temperature at which the oil will ignite. Pour Point (ASTM D97): Indicates the lowest temperature at which the oil will flow. Viscosity (ASTM D445): Measures the oil's resistance to flow. KPM provides a comprehensive range of oil testing instruments aligned with ASTM and IEC standards. These include BDV testers, Tan Delta analyzers, moisture testers. KPM also offers calibration, on-line testing, and training services, ensuring users maintain transformer health and meet regulatory requirements effectively. 11 How to measure oil density and what are its implications? Oil density is the mass per unit volume (typically expressed in kg/m³ or g/cm³) and is a key parameter in evaluating the quality and type of insulating oils used in transformers and electrical equipment. Measuring oil density helps in determining its composition, potential uses, and potential for refining into various products like gasoline, diesel, or asphalt. Changes in oil density can indicate contamination, degradation, or improper formulation, affecting cooling efficiency, dielectric strength, and compatibility with equipment materials. Accurate density measurement is essential during oil processing, quality checks, and routine maintenance. It is often performed at a standard reference temperature (usually 15°C or 20°C) using digital density meters or hydrometers, in line with ASTM D4052 or ISO 12185 standards. KPM offers precise digital density meters and oil analysis kits compliant with international standards. These tools are designed for ease of use, fast operation, and high accuracy. With additional support like calibration services and technical guidance, KPM ensures reliable oil density measurement, aiding customers in maintaining transformer performance and operational safety. 12 What are the Early Warning Signs from Your Oil Particle Counter? An oil particle counter detects and quantifies solid contaminants in insulating oil, providing early warning signs of equipment wear, insulation breakdown, or external contamination. Key indicators include: Rising Particle Counts: A sudden increase in particles, especially >4µm or >6µm, can signal insulation aging, arcing, or mechanical wear. Shift in Particle Size Distribution: A higher concentration of larger particles may indicate internal component failure. Exceeding ISO 4406 Cleanliness Codes: Values outside acceptable limits suggest a decline in oil cleanliness, potentially leading to reduced dielectric strength and accelerated aging. Regular monitoring allows for trend analysis, helping prevent failures before they occur. KPM provides portable and lab-grade oil particle counters aligned with ISO 4406 and NAS 1638 standards. These instruments offer accurate, real-time data for critical decision-making. Combined with expert support and service, KPM enables power utilities and industries to ensure oil cleanliness and extend equipment lifespan. 13 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? Using both TEV and ultrasonic methods together enhances diagnostic accuracy: TEV gives insight into internal discharge severity and location. Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. This dual-method approach is vital for: Preventive maintenance, Avoiding insulation failures, Improving switchgear reliability, and Extending equipment life without needing shutdowns.
- PD Detector (Digital) | KPM India |PD Detector (Digital)
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Digital) |https://kpmtek.wixsite.com/website/es/pd-detector-digital Detector de descargas parciales (digital)
- Cable Testing Equipment by KPM | Fault Location & Diagnostics|CABLE
Advanced cable testing equipment by KPM for precise fault location, insulation testing, and condition monitoring of power cables. MONITOREO EN LÍNEA DE PD Y TIERRA KPM TAN DELTA 40 KPM TD 40 KPM TD 40 capacitance and tan delta tester is designed for condition assessment of high capacitance & high voltage electrical insulation in high voltage apparatus. It is a measurement instrument that is used with an AC power source and a standard capacitor to form a complete measurement setup. KPM TD 40 is a two-piece design. the control module and the test module communicate wirelessly during the test. KPM DC HIPOT KPM DC HIPOT KPM Portable DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM- DC series of HIPOTs is light weight, portable & easy to use. These units are user friendly & its output is stable at even high voltages DC vs AC High-potential Testing Direct current high-potential testing provides several advantages over alternating current. KPM VLF Series KPM VLF Series KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. KPM AC HIPOT KPM AC HIPTO KPM Portable AC/DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM-AC/DC series of HIPOTs is light weight , portable & easy to use. These units are user friendly& its output is stable at even high voltages it is the basic test equipment used by the power station, transmission and distribution companies for testing the insulation strength of all kind of electrical products, electrical equipment and insulated materials. KPM VLF Hipot Tester KPM VLF Hipot Tester KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. Preguntas frecuentes (FAQ) FAQ about Cable testing : 01 1. What is VLF testing, and why is it used for cable diagnostics? VLF (Very Low Frequency) testing applies a low-frequency AC voltage—typically 0.01 Hz to 0.1 Hz—to power cables to assess their insulation condition. It’s used because VLF testing can apply a high voltage stress similar to normal operating conditions but with less heating and damage risk than standard power frequency tests. This makes it ideal for diagnosing medium- and high-voltage cables, especially in field conditions, to detect weaknesses like insulation degradation, voids, or defects before failure occurs. 02 2. How does VLF testing differ from conventional AC hipot testing? VLF testing uses a very low frequency (typically 0.01 to 0.1 Hz) AC voltage, whereas conventional AC hipot testing applies standard power frequency (50/60 Hz) voltage. The low frequency in VLF reduces the capacitive charging current in long cables, allowing high test voltages without overheating the cable insulation. This makes VLF safer and more practical for field testing of long medium- and high-voltage cables. In contrast, conventional AC hipot tests can cause excessive heating and damage when used on such cables. 03 3. What types of cable defects can VLF testing detect? VLF testing is effective at identifying a wide range of insulation defects and weaknesses within medium- and high-voltage power cables. It can detect partial discharge (PD) activity, which is a common early indicator of insulation deterioration such as microscopic voids or cracks within the cable’s insulation material. These PD sites generate localized electrical discharges that degrade the insulation over time, potentially leading to catastrophic failure if not addressed. Additionally, VLF testing can reveal water ingress problems, where moisture penetrates the insulation and lowers its dielectric strength, as well as contamination or aging effects such as thermal, mechanical, or chemical degradation of the insulation material. It can also uncover manufacturing defects like thin spots, improper curing, or insulation gaps. While VLF testing is excellent for assessing the overall integrity of the cable insulation and detecting areas of weakness, it may not precisely locate the defects. For detailed localization, it is often combined with other techniques such as partial discharge (PD) measurements or time-domain reflectometry (TDR). 04 4. What is Tan Delta (VLD) testing, and how does it assess cable insulation quality? Tan Delta (also called Very Low Dissipation factor or VLD) testing measures the dielectric losses in cable insulation by applying an AC voltage and analyzing the phase difference between the current and voltage. The "tan delta" represents the ratio of resistive (lossy) current to capacitive (ideal) current. A low tan delta value indicates good insulation with minimal energy loss, while higher values suggest deterioration due to moisture, contamination, or aging. By measuring these losses, Tan Delta testing assesses the overall insulation condition and detects early-stage degradation before catastrophic failure. It is highly sensitive to insulation quality changes and is commonly used for condition assessment and preventive maintenance of medium- and high-voltage cables. 05 5. How do Tan Delta results indicate the health or degradation of a cable? Tan Delta results reflect the insulation’s dielectric losses, which increase as the cable ages or deteriorates. A low tan delta value means the insulation is healthy, with minimal leakage current and good dielectric integrity. Conversely, a rising tan delta value indicates increasing insulation defects such as moisture ingress, contamination, cracks, or thermal aging. Trends in tan delta over time are especially important: a gradual increase suggests progressive degradation, allowing maintenance teams to plan repairs before failure occurs. Sudden spikes may point to acute damage or contamination. Thus, monitoring tan delta values helps assess the insulation’s condition, predict remaining service life, and prioritize maintenance actions. 06 6. What is VLF Partial Discharge (PD) testing, and how does it help's identify insulation defects? VLF Partial Discharge (PD) testing uses very low frequency voltage to stress the cable insulation while detecting and measuring partial discharges—tiny electrical sparks that occur within insulation voids or defects. These discharges are often early signs of insulation failure, caused by imperfections like cracks, voids, or contamination. By capturing PD activity, VLF PD testing helps pinpoint insulation defects before they lead to catastrophic cable failure. It provides valuable insight into the type, location, and severity of defects, enabling targeted maintenance and reducing unplanned outages. This makes it a crucial tool for proactive cable condition assessment. 07 7. Can VLF PD testing detect early-stage insulation failures? Yes, VLF Partial Discharge (PD) testing is specifically designed to detect early-stage insulation failures. Partial discharges are small electrical sparks that occur in microscopic voids, cracks, or impurities within the cable insulation—often long before a complete breakdown happens. By applying very low frequency voltage, VLF PD testing stresses the insulation gently but effectively, allowing detection of these early PD activities. Detecting partial discharges early helps identify weak spots or developing defects in the insulation, enabling maintenance teams to address issues proactively, extend cable life, and avoid costly unplanned failures. 08 8. What are the typical test voltages and frequencies used in VLF cable testing for 11 kV and 33 kV cables? For 11 kV cables, the VLF test voltage typically ranges from 15 kV to 33 kV, depending on the test type—diagnostic tests usually use about 1.5 times the rated voltage (around 16.5 kV), while withstand tests may apply up to 2.5 to 3 times the rated voltage (up to ~33 kV). For 33 kV cables, the test voltage typically ranges from 45 kV to 75 kV, with diagnostic tests at around 1.5 times the rated voltage (approximately 49.5 kV), and withstand tests potentially up to 2.5 times rated voltage (about 82.5 kV), though the upper limit depends on cable specifications and standards. In both cases, the frequency used is very low—typically 0.1 Hz—to reduce capacitive currents and minimize heating during testing, making it safe and effective for long cable lengths. 09 9. How do environmental factors affect VLF, Tan Delta, and PD test results? Environmental conditions like temperature, humidity, and soil moisture can significantly impact VLF, Tan Delta, and Partial Discharge (PD) test results. Temperature: Higher temperatures generally reduce insulation resistance and can increase Tan Delta values and PD activity due to increased molecular activity in the insulation. Low temperatures can raise resistance but might mask some defects. Humidity and Moisture: Moisture ingress lowers insulation resistance and increases dielectric losses, causing higher Tan Delta readings and more PD activity. Wet conditions can lead to more apparent insulation degradation during testing. Soil Conditions: For underground cables, soil resistivity and moisture affect grounding and test current paths, influencing VLF and PD measurements. Dry or rocky soils may lead to higher resistance readings. Surface Contamination: Dirt, oil, or salts on cable surfaces can cause surface discharges, impacting PD and Tan Delta results. Because of these factors, it’s important to consider and document environmental conditions during testing and, where possible, perform tests under similar conditions for consistent trending and accurate diagnostics. 10 10. What are the safety precautions and best practices during VLF and PD cable testing? Ensure Proper Training: Only qualified personnel familiar with high-voltage testing and equipment should conduct tests. Use Appropriate PPE: Wear insulated gloves, safety glasses, and flame-resistant clothing. Clear the Test Area: Establish a safe perimeter with warning signs and barriers to prevent unauthorized access during testing. Verify Equipment Condition: Check all test instruments, leads, and connections for damage before use. De-energize and Ground Cables: Ensure the cable is disconnected from the power system and properly grounded before connecting test equipment. Follow Manufacturer Guidelines: Use the recommended test voltages, durations, and procedures specific to the cable type and equipment. Monitor Test Parameters: Continuously observe voltage, current, and PD activity during the test to detect abnormalities early. Avoid Testing in Hazardous Environments: Do not perform tests during storms, wet conditions, or explosive atmospheres. Record Test Data Accurately: Document all parameters, environmental conditions, and observations for traceability and analysis. Emergency Preparedness: Have clear procedures for immediate shutdown and emergency response in case of equipment failure or personnel hazard. Following these precautions ensures safety and reliable test results while protecting both personnel and equipment.
- CT/PT Testing Kit by KPM | Current & Potential Transformer Testing|CT/PT Testing
KPM CT/PT testing kits deliver accurate and reliable current and potential transformer testing for industrial and electrical applications. KITS DE PRUEBAS DE TC Y PT Analizador CT/PT CT/PT Analyzer C+ KPM-CT/PT Analyzer es una solución todo en uno para probar todo tipo de CT/PT según las normas IEC. Es un equipo con alto ROI (Return On Investment). Below features make KPM CT/PT analyzer and ideal tool for_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Fabricante de CT/PT, laboratorios de prueba, subestaciones (hasta 765 KV), plantas de energía etc. Características Low Testing Time _cc781905-5cde -3194-bb3b-136bad5cf58d_ (Completes all test for CT/PT _cc781905-5cde -3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb3b- 136bad5cf58d_ _cc781905-5cde- 3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb 3b-136bad5cf58d_ _cc781905- 5cde-3194-bb3b-136bad5cf58d_ Winding & Cores in few min) Simple connection _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (Conexión simple de una sola vez) Highest Accuracy _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (0.05% for turns ratio & winding resistance ) Portátil y liviano ( < 15KG ) Rechazo de alta interferencia (Se puede usar en 220/400/765 KV Live Switchyards) Kit de inyección de corriente primaria KPM APIK 2000 Este dispositivo de prueba de subestaciones está diseñado para garantizar una alta salida de corriente cuando sea necesario en las actividades de puesta en marcha de subestaciones. La serie de equipos KPM PIK tiene las siguientes características: Salida de alta corriente hasta 8000 A Potente salida de hasta 35 kVA Diseño personalizado. Diseñado para pruebas de inyección primaria de relés de protección e interruptores automáticos, para puesta en marcha y renovación de subestaciones y redes eléctricas Diseño modular para facilitar el transporte Carrera de calor. CT/PT Pro CT/PT Pro KPM-CT/PT Pro is an automatic device used for testing of instrument transformadores por método de relación de tensión . CT/PT Pro es capaz de realizar las siguientes pruebas en CT y PT 1) Turns Ratio (error de relación y errores de fase) 2) Trazado de la curva de excitación 3) Resistencia de bobinado 4) Carga secundaria CT 3) Polaridad Especificaciones técnicas -: ROI más alto con una propuesta de valor nunca antes vista . Fácil de operar. KPM- CT PT Pror completa automáticamente la prueba y genera el informe . Tensión de salida máxima de 2000 V para prueba de características de excitación HVCTR (Probador de relación HV CT) CTR Probador de relación de CT HV en línea (KPM-HVCTR) - Probador de relación de transformador de corriente de alto voltaje Como sugiere el nombre, Online HV CT Ratio Tester (KPM-HVCTR) es un innovador_cc781905-5cde-3194-bb3b-136bad5cf58-3-3-3-3-51cde9 producto para medir Key0 -136bad5cf58d_ línea/parámetros CT de hasta Sistema de 33KV. El probador de relación HV CT en línea (KPM-HVCTR) se utiliza para la determinación de: Medición de corriente primaria y secundaria Relación de transformación actual Secuencia de fase Polaridad Analizador CT/PT CT/PT Analyzer KPM-CT/PT Analyzer es una solución todo en uno para probar todo tipo de CT/PT según las normas IEC. Es un equipo con alto ROI (Return On Investment). Below features make KPM CT/PT analyzer and ideal tool for_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Fabricante de CT/PT, laboratorios de prueba, subestaciones (hasta 765 KV), plantas de energía etc. Características Low Testing Time _cc781905-5cde -3194-bb3b-136bad5cf58d_ (Completes all test for CT/PT _cc781905-5cde -3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb3b- 136bad5cf58d_ _cc781905-5cde- 3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb 3b-136bad5cf58d_ _cc781905- 5cde-3194-bb3b-136bad5cf58d_ Winding & Cores in few min) Simple connection _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (Conexión simple de una sola vez) Highest Accuracy _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (0.05% for turns ratio & winding resistance ) Portátil y liviano ( < 15KG ) Rechazo de alta interferencia (Se puede usar en 220/400/765 KV Live Switchyards) Kit de inyección de corriente primaria PIK Este dispositivo de prueba de subestaciones está diseñado para garantizar una alta salida de corriente cuando sea necesario en las actividades de puesta en marcha de subestaciones. La serie de equipos KPM PIK tiene las siguientes características: Salida de alta corriente hasta 8000 A Potente salida de hasta 35 kVA Diseño personalizado. Diseñado para pruebas de inyección primaria de relés de protección e interruptores automáticos, para puesta en marcha y renovación de subestaciones y redes eléctricas Diseño modular para facilitar el transporte Carrera de calor. HVCTR (Probador de relación HV CT) HVCTR Probador de relación de CT HV en línea (KPM-HVCTR) - Probador de relación de transformador de corriente de alto voltaje Como sugiere el nombre, Online HV CT Ratio Tester (KPM-HVCTR) es un innovador_cc781905-5cde-3194-bb3b-136bad5cf58-3-3-3-3-51cde9 producto para medir Key0 -136bad5cf58d_ línea/parámetros CT de hasta Sistema de 33KV. El probador de relación HV CT en línea (KPM-HVCTR) se utiliza para la determinación de: Medición de corriente primaria y secundaria Relación de transformación actual Secuencia de fase Polaridad Comparación: CT PT Analyzer y CT PT Pro Vídeo - Analizador CT/PT CT/PT Videos KPM CT PT Testing Videos KPM CT PT Testing Videos Reproducir video Compartir Canal completo Este video Facebook Twitter Pinterest Tumblr Copiar Enlace Enlace copiado Search videos Buscar video... Ahora en reproducción Unboxing LA Tester , KPM LA 103+ 03:45 Reproducir video Ahora en reproducción KPM TAN DELTA - 12 KV (https://www.kpmtek.com/tandelta) 01:27 Reproducir video Ahora en reproducción UNBOXING RELAY TEST KIT - KINGSINE K3063I 05:50 Reproducir video Ahora en reproducción Testing Tan Delta in 765kV Live Switchyard 00:43 Reproducir video Teoría - Pruebas CT/PT CT PT Theory CT (Transformador de Corriente) – Teoría Como cualquier otro transformador, un transformador de corriente tiene un devanado primario, un núcleo magnético y un devanado secundario. La corriente alterna que fluye en el primario produce un campo magnético alterno en el núcleo, que luego induce una corriente alterna en el circuito del devanado secundario. Un objetivo esencial del diseño de transformadores de corriente es garantizar que los circuitos primario y secundario estén acoplados de manera eficiente, de modo que la corriente secundaria guarde una relación precisa con la corriente primaria. PT (Transformador de Potencial) – Teoría Una teoría del transformador de voltaje o la teoría del transformador de potencial es como la teoría del transformador reductor de propósito general. El primario de este transformador está conectado a través de las fases y tierra según el requisito. Al igual que el transformador, que se utiliza con fines reductores, el transformador de potencial, es decir, PT, tiene un devanado de vueltas más bajo en su secundario. El voltaje del sistema se aplica a través de los terminales del devanado primario de ese transformador, y luego aparece un voltaje secundario proporcional a través de los terminales secundarios del PT. Pruebas de CT/PT A continuación se muestra la lista de las principales pruebas realizadas en CT y PT Prueba de resistencia de aislamiento Prueba de polaridad Prueba de resistencia secundaria/de bucle Prueba de carga (prueba opcional) Prueba de curva de magnetización (prueba opcional) Prueba de curva de histéresis Prueba de relación de vueltas (prueba opcional) Prueba de inyección primaria Prueba de alto voltaje Preguntas frecuentes (FAQ) FAQ - CT PT Analyzer FAQ about all our CT/PT products : 01 ¿Qué tipo de CT puede probar KPM CT PT Analyzer? El analizador KPM CT PT es capaz de probar casi todos los tipos de CT y PT, incluidos los CT de medición y de protección. En cuanto a las aplicaciones, todos los tipos de TC utilizados en la distribución, transmisión y generación de energía se pueden probar con KPM CT/PT Analyzer. Los TC de aplicación especial, como el TC de anillo de conducto de bus, el TC de buje de transformador también se pueden probar. El analizador KPM CT PT puede probar un PT y CVT también utilizando un accesorio de refuerzo de voltaje. 02 ¿Puede KPM CT PT Analyzer probar CT de conductos de bus de generador? Sí, el analizador KPM CT PT puede probar CT de conducto de bus de generador a la perfección. 03 ¿Puede KPM CT PT Analyzer probar los CT de aisladores de transformadores de potencia ? Sí, KPM CT PT Analyzer prueba los TC de aisladores de transformadores de potencia a la perfección. 04 ¿Por qué probar un TC de aisladores de transformadores de potencia es un asunto complejo para cualquier equipo de prueba de TC? El analizador KPM CT PT funciona según el principio del método de relación de voltaje. Mientras se prueba un TC de buje de transformador de potencia, el circuito primario está conectado al devanado del transformador de potencia en serie, lo que hace que la prueba sea compleja. El analizador KPM CT PT, con la ayuda de su circuito de reducción de ruido, es capaz de probar a la perfección el TC de aisladores de transformadores de potencia. 05 ¿Cuál es el punto de inflexión más alto probado por KPM CT PT Analyzer? El analizador KPM CT PT satura el núcleo de los CT con un punto de inflexión alto mediante el principio de reducción de frecuencia. Así que prácticamente puede probar el punto de inflexión de todo tipo de CT de protección EHV utilizando su fuente de bajo voltaje. Teóricamente, puede probar hasta 35KV de punto de rodilla. 06 ¿El analizador KPM CT PT es portátil? El analizador KPM CT PT es altamente portátil con un tamaño (WXHXD) en mm 485 X 356 X 183 y un peso < 15 kg. Esto lo convierte en un equipo ideal para viajar. 07 Qué tipo de clientes del sector energético utilizan KPM CT PT Analyzer El analizador KPM CT PT es utilizado por todo tipo de clientes que se encuentran en generación, transmisión y distribución de energía. 08 ¿Podemos medir la resistencia primaria y secundaria de un PT usando el analizador KPM CT PT? La resistencia del devanado primario de PT está en Kohms. El analizador KPM CT PT tiene un rango de resistencia en Kohms, con la ayuda de la cual puede probar fácilmente la resistencia primaria de un PT. La resistencia secundaria de PT está en ohmios y se puede probar fácilmente. 09 ¿Podemos obtener una curva de histéresis de un TC usando el analizador KPM CT PT? Sí, el analizador KPM CT PT tiene una función de curva de histéresis. Al final de la prueba, se calcula la curva de histéresis del TC, que muestra claramente las características de pérdida de potencia del TC bajo prueba. 10 ¿Qué es la curva de histéresis y cuál es su relevancia? La magnetización de las sustancias ferromagnéticas debido a un campo magnético variable va a la zaga del campo. Este efecto se llama histéresis, y el término se usa para describir cualquier sistema cuya respuesta depende no solo de su estado actual, sino también de su historia pasada. En KPM CT PT Analyzer, se calcula la curva de histéresis de CT. El ancho de la curva de histéresis muestra claramente las características de pérdida de potencia del CT bajo prueba. 11 Cómo el analizador KPM CT PT puede encontrar automáticamente un valor de resistencia de devanado a 75 °C. El analizador KPM CT PT tiene un sensor de temperatura incorporado con la ayuda del cual mide la temperatura ambiente en el momento de la prueba de resistencia del devanado. Una vez que se completa la prueba, muestra el valor de resistencia del devanado a temperatura ambiente y también la temperatura de resistencia del devanado compensada. valor @ 75'C automáticamente. Esto reduce la posibilidad de cualquier error humano debido al ingreso manual de datos de temperatura. 12 ¿Qué es la prueba de carga secundaria de TC y cuál es su relevancia? Todo tipo de CT y PT están diseñados para soportar una carga fija. Si la carga conectada de un TC es mayor que la carga requerida, entonces la salida del TC no se ajustará a las especificaciones y se introducirá un error. El analizador KPM CT PT tiene una función de prueba de carga en la que el analizador KPM CT PT encuentra el VA del bucle completo del conductor. 13 ¿Qué prueba se puede realizar con el analizador KPM CT PT? La siguiente prueba se puede realizar en CT y PT usando KPM CT/PT Analyzer Pruebas para Transformador de corriente: Prueba de parámetros y curva de excitación Prueba de relación de transformación Prueba de relación y error de fase Comprobación de marca de polaridad Medición de resistencia de bobina Medición de carga de bucle secundario Prueba de curva de línea de error para TC de protección Prueba de parámetros transitorios de TC Conjetura de la placa de identificación de CT Medición de curva de bucle de histéresis de saturación Pruebas para transformador de tensión: Prueba de error de relación de transformación y ángulo de fase Prueba de polaridad Prueba de carga secundaria Prueba de resistencia de devanados
- KPM Battery Testing Utility | Accurate Battery Diagnostics| Battery Testing ( Utility )
KPM battery testing utility ensures accurate performance analysis, reliable diagnostics, and efficient battery maintenance for industrial and electrical applications. KITS DE PRUEBA DE BATERÍA ( UTILIDAD ) Resistencia de la batería y Probador de conductancia Contáctenos Analizador de estado de batería BA-01 El BA-01 Battery Condition Anlayzer es un probador actualizado que es un dispositivo de administración de batería muy efectivo y económico para probar la resistencia interna (o conductancia) y el voltaje de la batería. Le ayuda a eliminar las baterías débiles para garantizar el rendimiento de sus sistemas de baterías. Es capaz de realizar mediciones precisas y consistentes de la resistencia interna (o conductancia) de la batería, baterías de plomo-ácido reguladas por válvula (VRLA), baterías de plomo-ácido ventiladas (VLA) y baterías de Ni-cd, que son la composición principal de los sistemas de energía críticos en espera. Este comprobador de baterías se aplica ampliamente a proveedores de servicios, equipos de operaciones y mantenimiento para la gestión y medición de baterías a fin de garantizar la integridad de la energía en diversas industrias. Registrador de datos de batería Contáctenos Registrador de datos de batería BDL es un registrador de datos de batería actualizado para cumplir con los estándares de medición IEEE para voltaje de batería, voltaje de cadena, corriente y temperatura ambiente. Se personaliza de 12 V a 700 V para diferentes sistemas de baterías. Y tiene fácil expansión para todos los sistemas de batería. Con la comunicación wifi, puede ver fácilmente los datos completos y generar un informe de prueba en el software de la PC. Para una prueba rápida de la conductancia/resistencia interna de la batería, consulte también Analizador de estado de batería BA-01 . Banco de carga de batería Contáctenos Banco de carga de batería KPM Ofrecemos una serie de bancos de carga de baterías personalizados con muchos modelos diferentes para la prueba de descarga de corriente constante y la prueba de capacidad de la batería. Cubren un amplio rango de tensión desde 12V hasta 480V de tensión nominal con corriente de hasta 600A. Se aplican ampliamente en diversas industrias. Con su Estuche de Adquisición de Datos (DAC) de batería opcional, los valores de descarga de CADA celda pueden monitorearse en el banco de carga de batería y el software de PC simultáneamente usando el software de visualización de datos de KPM. El mismo banco de carga de batería DAC en también puede funcionar de forma independiente con "String DAC" para hacer otro producto, Registrador de datos de batería BDL-3926C . Para una prueba rápida del estado de la batería, consulte Analizador de estado de batería BA-01 que prueba la conductancia/resistencia interna de la batería en segundos. Preguntas frecuentes FAQ about all our battery utility : 01 What is the purpose of battery utility testing in backup power systems? Battery utility testing ensures the reliability, health, and performance of backup power systems used in utilities, substations, data centers, and critical infrastructure. Over time, batteries degrade due to factors like temperature, charge-discharge cycles, and age. Testing helps detect early signs of failure such as increased internal resistance, reduced capacity, or imbalance among cells. This enables timely maintenance or replacement, preventing unexpected power loss during outages. Utility testing validates whether batteries meet required discharge durations and ensures compliance with standards like IEEE 450 or IEC 60896. Regular testing minimizes downtime, enhances operational safety, and protects expensive downstream equipment. KPM provides advanced battery analyzers and constant current discharge kits designed for utility-scale battery banks. These instruments measure internal resistance, voltage, and capacity under load conditions. KPM’s systems are aligned with international testing standards and are used by utilities to perform periodic health checks, identify weak cells, and ensure uninterrupted power backup readiness. 02 What safety precautions must be taken during battery testing? Battery testing involves handling high voltages, currents, and hazardous chemicals, so strict safety precautions are essential. Always wear appropriate personal protective equipment (PPE) such as insulated gloves, eye protection, and flame-resistant clothing. Ensure proper ventilation, especially for lead-acid batteries that emit hydrogen gas during charging or discharging. Isolate the battery bank from the load before testing, and use insulated tools to prevent short circuits. Verify polarity before connecting test equipment to avoid damage or sparking. Never allow metal objects near open battery terminals. Maintain safe distances and use warning signs during high-current discharge tests. Monitor temperature rise and terminate testing if overheating or voltage instability is observed. Follow the manufacturer’s guidelines and applicable standards (IEEE, IEC) during every procedure. KPM’s battery analyzers and discharge testers are equipped with multiple safety features such as overcurrent protection, reverse polarity alarms, thermal cutoffs, and auto-shutdown. KPM also provides user training and safety documentation to ensure proper and secure operation. 03 How does internal resistance measurement indicate battery health? Internal resistance (IR) is the opposition a battery offers to current flow within its own structure. As batteries age or degrade, their internal resistance increases due to chemical wear, sulfation (in lead-acid), or electrode deterioration. Here's how it reflects battery health: Low IR = Healthy battery: Indicates good electrolyte condition, intact electrodes, and low energy loss during discharge. High IR = Degraded battery: Results in voltage drops under load, reduced capacity, and heat generation during operation. Rising IR over time signals aging or developing faults, even if voltage appears normal. Sudden spikes in IR may indicate failing cells or poor interconnections. Thus, internal resistance is a quick, non-invasive diagnostic metric used to identify weak or failing batteries before they cause critical power failures. KPM’s battery analyzers measure IR accurately across large battery banks, providing real-time indicators of cell health and enabling predictive maintenance. 04 What are the key parameters measured by a battery analyzer? A battery analyzer is used to assess the condition and performance of individual cells and complete battery banks. The key parameters it typically measures include: Internal Resistance (IR):Indicates the battery’s ability to deliver current. Higher resistance means deterioration or aging. Voltage (V): Measures the open-circuit voltage of each cell or unit to check state-of-charge and overall health. Conductance (optional): Used as an alternative to resistance in some analyzers to determine battery condition. Temperature (°C): Affects performance and safety. Monitoring ensures accurate readings and helps prevent overheating. State of Health (SoH): Some analyzers estimate the health of the battery based on historical and real-time data. Cell Imbalance: Detects inconsistencies among cells in a battery bank, which can lead to system failure. Ripple Voltage (if applicable): Monitors AC noise on DC lines, often in UPS and telecom systems. KPM’s battery analyzers measure all key parameters—internal resistance, voltage, temperature, and cell imbalance—with high accuracy. Features include: High-precision sensors and rugged design for utility environments, Built-in safety features (reverse polarity, overvoltage alerts), PC software for data logging, trending, and report generation. Widely used in substations, power plants, and telecom towers for preventive maintenance and health diagnostics. 05 Can battery conductivity testing detect early-stage cell degradation ? Conductivity is a measure of a battery’s ability to pass electrical current. In healthy batteries, conductivity is high because the internal chemical pathways are clean and efficient. As a cell begins to degrade (due to sulfation, corrosion, electrolyte breakdown, or plate shedding), these pathways become obstructed, causing conductivity to decrease—even before voltage or capacity noticeably drops. Early Detection: Changes in conductivity often occur before performance failures, allowing for early intervention. Identifies Weak Cells: It helps isolate underperforming cells within a battery bank. Prevents Failures: Enables predictive maintenance and avoids costly downtime. Monitors Aging: Tracks gradual degradation over time for lifecycle management. KPM’s advanced battery analyzers can perform conductivity or internal resistance-based diagnostics, depending on battery type. These tools help utility and industrial users identify subtle degradation trends early, plan timely maintenance, and ensure long-term battery reliability. 06 Why is constant current discharge testing crucial in critical power applications? Constant current discharge testing is essential because it directly evaluates a battery’s actual capacity and performance under load, simulating real-world power demands. In critical power applications—such as substations, hospitals, data centers, and telecom systems—batteries must supply reliable power during outages or switching events. If a battery cannot sustain the required current for the expected duration, it risks system failure, data loss, or equipment damage. Key reasons it’s crucial: Confirms True Capacity: Validates if the battery can deliver its rated ampere-hours (Ah) under specified load. Identifies Weak Batteries: Detects hidden degradation not revealed by voltage or internal resistance alone. Reveals Runtime Performance: Simulates backup duration under real conditions. Supports Preventive Maintenance: Enables data-driven decisions for battery replacement and servicing. KPM’s constant current discharge kits are designed for high-reliability environments. They offer programmable loads, auto cut-off, data logging, and safety features, ensuring accurate, safe, and standards-compliant capacity testing for critical backup systems. 07 How is the battery's capacity (Ah) validated through a discharge test? Battery capacity, measured in ampere-hours (Ah), is validated by discharging the battery at a constant current until it reaches its specified cut-off voltage. The total time it takes to reach that voltage determines the actual capacity using the formula: Capacity (Ah)=Discharge Current (A) × Discharge Time (hours) Example: If a battery is discharged at 10 A and it takes 5 hours to reach the end voltage, the delivered capacity is: 10 A × 5 hrs = 50 Ah This result is then compared to the battery’s rated capacity (e.g., 100 Ah). If it delivers significantly less, it indicates degradation or failure. KPM’s constant current discharge kits precisely control and monitor the discharge current and voltage. They record time-stamped data, auto-calculate Ah, and generate test reports. These tools comply with standards like IEEE 450, ensuring reliable capacity validation for utility and industrial batteries. 08 What role does ambient temperature play in discharge test accuracy? Ambient temperature has a significant impact on the accuracy and outcome of battery discharge tests. Battery performance is highly temperature-sensitive, particularly for lead-acid, lithium-ion, and Ni-Cd chemistries. At High Temperatures: Battery capacity appears higher because chemical reactions speed up. Can lead to overestimation of real-world performance. Increases the risk of thermal runaway or cell damage. At Low Temperatures: Capacity drops due to slower electrochemical activity. May result in underestimated performance and early cut-off in tests. Internal resistance rises, leading to voltage drops under load. Deviations from this temperature should be noted and corrected using manufacturer-specified compensation factors or software. KPM’s battery discharge testers and analyzers include temperature monitoring sensors. The system records ambient and cell temperatures during testing and can apply correction factors to ensure accurate capacity evaluation under varying environmental conditions. 09 How do we determine end-voltage for discharge cut-off? The end-voltage, or cut-off voltage, is the minimum voltage at which a battery should be discharged to avoid deep discharge damage and to ensure reliable capacity measurement. It is determined based on the battery type, rated capacity, discharge rate (C-rate), and manufacturer specifications. For example, a 12V lead-acid battery typically has an end-voltage of 10.5V (1.75V per cell) at standard rates. Discharging below this threshold can lead to irreversible sulfation, reduced life, or failure. In lithium-ion batteries, cut-off is often set higher (e.g., 2.5V–3.0V per cell) to protect cell chemistry and safety. The correct end-voltage ensures consistent and safe testing across different test cycles. It must also be adjusted for ambient temperature and load current, as higher loads can cause greater voltage sag. KPM’s discharge kits allow users to program end-voltage settings per battery specs. The system automatically halts testing at the preset voltage to prevent over-discharge and protect battery health. 10 How can test data be used to predict battery end-of-life? Battery test data—such as internal resistance, voltage, capacity, and temperature trends—can be analyzed over time to accurately predict end-of-life (EOL). A consistent increase in internal resistance and decline in capacity (Ah) are key indicators of aging. When a battery can no longer deliver at least 80% of its rated capacity, it is generally considered at the end of its useful life. Regular discharge tests and impedance measurements create a performance history that reveals degradation rates, enabling predictive analytics. By identifying abnormal changes, such as faster resistance rise in one cell compared to others, maintenance teams can isolate failing units early. Trend-based monitoring allows scheduling replacements before failures occur, ensuring reliability in critical applications. KPM’s analyzers and discharge kits offer data logging, graphing, and reporting features that help utilities and industries track battery health over time, enabling data-driven EOL prediction and proactive asset management.
- Members | KPM India |Members
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Members |https://kpmtek.wixsite.com/website/es/members
- Voltage Regulator (ContactType) | KPM India |Voltage Regulator (ContactType)
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Voltage Regulator (ContactType) |https://kpmtek.wixsite.com/website/es/voltageregulator-contacttype Regulador de voltaje (tipo de contacto)
- Career | KPM India |Career
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc. |Career | https://www.kpmtek.com/career Do you have it in you Careers "Welcome to KPM's Careers Page, where opportunities for growth and innovation abound. At the heart of our success is a vibrant culture that values collaboration, diversity, and continuous learning. We're on a mission "to bring reliable & robust solutions to customers all across the world with best ROI and backing them with expert application support " , and we're searching for dedicated individuals who share our commitment to excellence. Explore our current job openings and discover a workplace where your unique skills and aspirations can thrive. Our employees are at the core of our success, and we invite you to be a part of our dynamic team. With comprehensive benefits, a commitment to diversity and inclusion, and a supportive environment, KPM is not just a workplace—it's a place to build a rewarding career. Take the first step toward joining us on this exciting journey!" Lab Assistant/Manager – Transformer Oil Testing Lab Tanzania Job Title: Lab Assistant – Transformer Oil Testing Lab Location: Tanzania Company: Confidencial, KPM's Client Joining : Immediate About the Role: We are seeking a dedicated and detail-oriented Lab Assistant to manage a state-of-the-art Transformer Oil Testing Lab for our esteemed client in Tanzania. This role offers an exciting opportunity to work with advanced diagnostic equipment and contribute to ensuring the reliability and efficiency of critical power sector assets. With infinite future growth prospects, this position is ideal for someone passionate about electrical testing and laboratory operations. Key Responsibilities: Conduct Dissolved Gas Analysis (DGA) to detect and diagnose faults in transformer oil. Perform Furan Analysis to assess the degradation of transformer insulation. Test Oil Acidity to monitor the chemical stability and performance of insulating oils. Operate and maintain the Karl Fischer Titrator for precise moisture content determination. Prepare oil samples, follow standard testing procedures, and document all results accurately. Ensure proper calibration and maintenance of lab equipment. Analyze test results and prepare detailed technical reports. Adhere to safety protocols and maintain a clean, organized lab environment. Collaborate with engineers and technical staff to interpret data and recommend actions. Qualifications and Skills: Diploma or Bachelor’s degree in Chemistry, Electrical Engineering, or a related field. Proven experience in transformer oil testing or similar laboratory environments. Familiarity with DGA, Furan Analysis, Oil Acidity tests, and Karl Fischer testing methods. Strong analytical and problem-solving skills. Excellent attention to detail and data recording accuracy. Ability to work independently and as part of a team. Effective communication skills for reporting and client interactions. Why Join Us: Opportunity to work in a growing power sector in Tanzania. Hands-on experience with cutting-edge testing equipment. Career advancement and future leadership opportunities. Collaborative and innovative work environment. Remuneration: Competitive salary based on experience and qualifications. Additional benefits and performance-based incentives. Opportunities for professional development and career growth. If you are passionate about electrical testing and eager to grow your career in a dynamic lab setting, we invite you to apply and become a vital part of our client’s success story. How to Apply: Please send your updated resume and a cover letter to consultant@kpmtek.com . We look forward to building the future of transformer diagnostics together! Customer Support Engineer - Electrical Testing Equip. Gurgaon , Bangalore We are a close-knit team of electrical engineers supplying and supporting our high-tech solutions in field of electrical testing and measuring equipment. We are looking for a self motivated Customer Support Engineer with below profile. Shall be capable of having technical discussions with customers and backing the sales team , Competition Study , Customer Tracing etc. Computer Savvy and capable of coordinating webinars, Ms Office Reporting , editing Technical Manuals & Data-sheets etc. Shall have basic knowledge in all electrical equipment such as ,Transformers, HV /MV and LV Switchgear, circuit breakers, earthing system, Lightning Arresters , Relays etc. Knowledge of below subjects will be an advantage -: CT / PT Testing Equipment Relay Testing Equipment Transformer Testing Equipment Circuit Breaker Testing Equipment Earth Testing You'll work in an office environment, but will frequently travel within the day for face-to-face meetings with customers and other business partners. You will be involved in technical discussions, product trainings and application support. If you are looking for a next level of challenge we motivate you to mail your CV to us today on below email ID - consultant@kpmtek.com
- About Us | KPM Engineering Solutions Pvt. Ltd.|Privacy & Disclaimer
KPM ENGINEERING SOLUTIONS is electrical test equipment provider with strong support. Our solutions are Relay Test Kit, CT/PT Analyzer, Oil BDV, Tan delta , Circuit Breaker Analyzer, LA Testing,Partial Discharge Test Kit, Thermal Imager Camera, PIK, SIK, AC/DC HIPOT. Visit us @ www.kpmtek.com Política de privacidad de KPM Bienvenido al Centro de privacidad de KPM Echa un vistazo. Aprenderá cómo KPM trata su información personal, junto con formas de controlar sus preferencias y configuraciones. Como siempre, KPM se compromete a ganar su confianza. Qué cubre esta política de privacidad KPM toma su privacidad muy en serio. Lea lo siguiente para obtener más información sobre nuestra política de privacidad. Cómo utiliza KPM su información personal Esta política cubre cómo KPM trata la información personal que KPM recopila y recibe, incluida la información relacionada con su uso anterior de los productos y servicios de KPM _cc781905-5cde-3194-bb3b-1586dbad5cf . La información personal es información sobre usted que es identificable personalmente, como su nombre, dirección, dirección de correo electrónico o número de teléfono, y que de otra manera no está disponible públicamente. Esta política de privacidad solo se aplica a KPM Esta política no se aplica a las prácticas de empresas que KPM no posee ni controla, ni a las personas que KPM no emplea ni administra. Además, algunas empresas que KPM ha adquirido tienen sus propias políticas de privacidad preexistentes que se pueden consultar en nuestra página de empresas adquiridas. Recopilación y uso de información General KPM recopila información personal cuando se registra en KPM, cuando utiliza KPM productos o servicios, cuando visita KPM _cc781905-5cde-3194-bb3b-1536bad5scf o las páginas de ciertos KPM partners, y cuando participa en promociones o sorteos. KPM puede combinar información sobre usted que tenemos con información que obtenemos de socios comerciales u otras empresas. Cuando se registra, le solicitamos información como su nombre, dirección de correo electrónico, fecha de nacimiento, sexo, código postal, ocupación, industria e intereses personales. Para algunos productos y servicios financieros, si se ofrecen, también podemos solicitar su dirección e información sobre sus activos. Cuando se registra en KPM e inicia sesión en nuestros servicios, no es anónimo para nosotros. KPM recopila información sobre sus transacciones con nosotros y con algunos de nuestros socios comerciales, incluida información sobre su uso de productos y servicios financieros, si se ofrecen. KPM automáticamente recibe y registra información de su computadora y navegador, incluida su dirección IP, KPM información de cookies, atributos de software y hardware, y la página que solicita. Además, cuando utiliza los servicios de KPM, puede optar por hacer pública parte de su información personal. Si publica información personal en línea que es accesible al público, puede recibir mensajes no solicitados de otras partes a cambio y KPM no será responsable del uso o mal uso de dicha información. KPM usa la información para los siguientes propósitos generales: personalizar la publicidad y el contenido que ve, satisfacer sus solicitudes de productos y servicios, mejorar nuestros servicios, contactarlo, realizar investigaciones y proporcionar informes anónimos para fines internos. y clientes externos. KPM no es responsable de la exactitud, integridad, veracidad ni confiabilidad de cualquier publicidad y contenido, productos o servicios a los que pueda acceder o publicitarse y KPM no será responsable de cualquier pérdida o daño que surja de la misma. KPM no alquila, vende ni comparte información personal sobre usted con otras personas o compañías no afiliadas, excepto para proporcionar productos o servicios que haya solicitado, cuando tengamos su permiso, o bajo los siguientes circunstancias: Proporcionamos la información a socios de confianza que trabajan en nombre de o con KPM bajo acuerdos de confidencialidad. Estas empresas pueden utilizar su información personal para ayudar a KPM a comunicarse con usted acerca de las ofertas de KPM y nuestros socios de marketing. Sin embargo, estas empresas no tienen ningún derecho independiente para compartir esta información. Respondemos a citaciones, órdenes judiciales o procesos legales, o para establecer o ejercer nuestros derechos legales o defendernos de reclamos legales. Creemos que es necesario compartir información para investigar, prevenir o tomar medidas con respecto a actividades ilegales, sospechas de fraude, situaciones que impliquen amenazas potenciales a la seguridad física de cualquier persona, violaciones de los términos de uso de KPM o según se requiera de otra manera. por ley. Transferimos información sobre usted si KPM es adquirida o fusionada con otra empresa. En este caso, KPM le notificará antes de que se transfiera su información y quede sujeta a una política de privacidad diferente. KPM muestra anuncios dirigidos basados en información personal. Los anunciantes (incluidas las empresas de publicación de anuncios) pueden suponer que las personas que interactúan, ven o hacen clic en anuncios dirigidos cumplen los criterios de orientación, por ejemplo, mujeres de 18 a 24 años de un área geográfica en particular. KPM no proporciona ninguna información personal al anunciante cuando interactúa o ve un anuncio dirigido. Sin embargo, al interactuar o ver un anuncio, usted acepta la posibilidad de que el anunciante asuma que usted cumple con los criterios de orientación utilizados para mostrar el anuncio. KPM puede contactarlo a través de servicios de llamadas de terceros para promoción o discusiones relacionadas con su tema. KPM trabaja con proveedores, socios, anunciantes y otros proveedores de servicios en diferentes industrias y categorías de negocios. Para obtener más información sobre los proveedores de productos o servicios que ha solicitado, lea nuestros enlaces de referencia detallados. Galletas KPM puede establecer y acceder a KPM cookies en su computadora. KPM permite que otras empresas que muestran anuncios en algunas de nuestras páginas configuren y accedan a sus cookies en su computadora. El uso de cookies por parte de otras empresas está sujeto a sus propias políticas de privacidad, no a esta. Los anunciantes u otras empresas no tienen acceso a las cookies de KPM. KPM utiliza balizas web para acceder a KPM cookies dentro y fuera de nuestra red de sitios web y en relación con KPM _cc781905-5cde-3194-bb3b-1536d_bad5cf productos y servicios. Su capacidad para editar y eliminar la información y las preferencias de su cuenta General Puede editar su KPM Información de cuenta, incluidas sus preferencias de marketing, en cualquier momento. Es posible que se agreguen nuevas categorías de comunicaciones de marketing a la página de Preferencias de marketing de vez en cuando. Los usuarios que visitan esta página pueden optar por no recibir futuras comunicaciones de marketing de estas nuevas categorías o pueden darse de baja siguiendo las instrucciones contenidas en los mensajes que reciben. Nos reservamos el derecho de enviarle ciertas comunicaciones relacionadas con el servicio KPM , como anuncios de servicio, mensajes administrativos y el boletín informativo KPM , que se consideran parte de su KPM account, sin ofrecerle la oportunidad de optar por no recibirlos. Puede eliminar su KPM account solicitándonos la eliminación de la cuenta. Confidencialidad y Seguridad Limitamos el acceso a su información personal a los empleados que creemos que necesitan razonablemente entrar en contacto con esa información para proporcionarle productos o servicios o para hacer su trabajo. Contamos con protecciones físicas, electrónicas y de procedimiento que cumplen con las reglamentaciones federales para proteger su información personal. Para obtener más información sobre seguridad, incluidos los pasos de seguridad que hemos tomado y los pasos de seguridad que puede tomar, lea Seguridad en KPM. Cambios a esta política de privacidad KPM puede actualizar esta política. Le notificaremos sobre cambios significativos en la forma en que tratamos la información personal enviando un aviso a la dirección de correo electrónico principal especificada en su cuenta de KPM account o colocando un aviso destacado en nuestro sitio. Preguntas y Sugerencias Si tiene preguntas o sugerencias, complete a formulario de comentarios o puede contactarnos en: sales@kpmtek.com Anchor 1
- Non PD Coupling Capacitor | KPM India |Non PD Coupling Capacitor
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Non PD Coupling Capacitor |https://kpmtek.wixsite.com/website/es/coupling-capacitor Condensador de acoplamiento sin PD
- form page | KPM India |form page
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|form page |https://kpmtek.wixsite.com/website/es/form-page Customer Information Contact Person: Designation and Dept. Company Name: Phone Number: Email Address: Website (if any): Location (City, Country): Machine Requirements Machine application If application is not mentioned * Make/Brand Model (Please mention "not decided" in case model is not finalised by you) Mention detailed specification and purpose of machine Expected Purchase Timeline (in months) Immediate 1–3 months 3–6 months 6 or more Expected Budget in lakhs Submit
- Voltage Regulator (Column Type) | KPM India |Voltage Regulator (Column Type)
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Voltage Regulator (Column Type) |https://kpmtek.wixsite.com/website/es/voltageregulator Regulador de voltaje (tipo de columna)