Search Results
Buscar en este sitio
Se encontraron 91 resultados sin ingresar un término de búsqueda
- Demo Registration | KPM India |Demo Registration
Register today for demonstrations of KPM Electrical Testing Equipment. Formulario de consulta de servicio
- SF6 Gas Testing Equipment by KPM | Gas Analysis & Detection|SF6 Gas Test Equipment
KPM SF6 gas test equipment ensures accurate measurement, reliable diagnostics, and efficient monitoring for electrical and industrial applications. EQUIPO DE PRUEBA DE GAS SF6 (GIS) Analizador de gas SF6 Especificaciones técnicas -: 1. Pureza de SF6: 0~100 % de SF6 (proporción de peso); 2. Productos de descomposición de SF6: 1.SO2: 0~200ppm; 2.H2S: 0~200ppm; 3.HF: 0~10ppm; 4. CO: 0 ~ 1000 ppm; 3. Precisión de la medición a) Pureza de SF6: ±0.1%, irrelevante para el flujo; b) Productos de descomposición de SF6: 0,1 ppm; 4) Tiempo de respuesta a) Pureza de SF6: 30 s; b) Productos de descomposición de SF6: 10 ~ 15 s。 Contáctenos Medidor de punto de rocío SF6 ( KPM DPM-01 ) Ampliamente utilizado en talleres, oficinas, plantas, estaciones informáticas, laboratorios y almacenes. El medidor de punto de rocío portátil KPM-DPM-82H se utiliza para aplicaciones de verificación puntual y calibración de campo. Ofrece una medición precisa y rápida para aplicaciones de punto de rocío industrial, como aire comprimido, gas Sf6, _cc781905 -5cde-3194-bb3b-136bad5cf58d_tratamiento de metales, fabricación aditiva y secado de alimentos y plásticos. Ventajas-: Accurate measurement y tiempo de medición rápido. La pantalla digital da una lectura exacta con un error mínimo Amplio rango de medición y alta resolución. Los últimos valores / Máx. Valores / Min. Valores de tanto la humedad como la temperatura se almacenarán automáticamente en la memoria y se podrán visualizar. El uso de componentes resistentes y duraderos, incluida una carcasa de plástico ABS resistente y ligera, garantiza un rendimiento sin mantenimiento durante muchos años. La carcasa ha sido cuidadosamente diseñada para adaptarse cómodamente a cualquier mano. Contáctenos Medidor de punto de rocío SF6 (KPM DPM-01) Especificaciones técnicas -: KPM-DPM-01 adopta un sensor de humedad capacitivo de película importada y tecnología de microcomputadora. It está desarrollado como un instrumento inteligente de medición de trazas de humedad con buen rendimiento. Su operación es simple y tiene la función de conversión entre Td, RH, PPM y actualización de software. El detector se puede utilizar en pruebas de humedad del aire, incluidos aire, nitrógeno, gas inerte y cualquier aire que no contenga medios corrosivos, especialmente la prueba de humedad del aire SF6. Características Autocalibración del punto cero y de la pendiente después del inicio, calibración del punto de rocío mediante un solo punto para rango completo (tecnología patentada) Diseño de circuito de gas único, buena hermeticidad y permeabilidad al gas, resistencia al agua. El cristal líquido TFT de pantalla grande muestra el valor del punto de rocío y el % de HR relativo correspondiente Valor de humedad, valor de humedad PPM Almacenamiento y consulta de datos de medición Aviso de alimentación inteligente, protección de carga inteligente La batería de litio ofrece fuente de alimentación de larga espera Contáctenos Preguntas frecuentes (FAQ) FAQ about SF6 GAS testing : 01 Is SF6 Gas Testing: Health, Safety, and Environmental Implications? Sulfur hexafluoride (SF₆) is widely used as an insulating and arc-quenching gas in high-voltage switchgear due to its excellent dielectric properties. However, SF₆ is a potent greenhouse gas, with a global warming potential over 23,000 times that of CO₂. Hence, rigorous testing and handling are essential for environmental compliance and personnel safety. Key SF₆ tests include moisture content, purity, and decomposition products (like SO₂ and HF), which help detect gas leakage, contamination, or insulation failure. Exposure to decomposition byproducts can pose health hazards such as respiratory irritation or chemical burns, necessitating strict handling protocols and personal protective equipment (PPE). KPM offers advanced SF₆ gas analyzers that measure purity, moisture, and decomposition gases in accordance with IEC 60376 and 60480 standards. With portable, user-friendly designs and accurate sensors, KPM’s instruments support safe operation, environmental responsibility, and preventive maintenance of gas-insulated systems. 02 What Is a Dew Point Meter and Why Is It Essential for SF6 Systems? A dew point meter is a device that measures the dew point, the temperature at which air becomes saturated and water vapour condenses into liquid water. In SF6 (sulfur hexafluoride) systems, dew point meters are crucial for monitoring moisture levels, as even small amounts of water can lead to hydrolysis, forming corrosive byproducts like hydrofluoric acid, which damage insulation and metal components. Excess moisture can also reduce the dielectric strength of SF₆, increasing the risk of flashovers and system failures. Regular dew point monitoring ensures that SF₆ gas remains dry and stable, extending the lifespan of high-voltage equipment like GIS (Gas Insulated Switchgear). KPM's Dew Point Meters provide fast, accurate, and reliable measurements, with robust sensors designed for field and laboratory use. These meters help utilities maintain safety, reliability, and regulatory compliance, making them an essential part of preventive maintenance in SF₆ systems. 03 What is PQ analyzer , how it is different than Power recorders ? A Power Quality Analyzer and a Power Recorder may appear similar at first glance, but they serve distinct purposes in electrical diagnostics and monitoring. A Power Quality Analyzer is specifically designed to detect, analyze, and troubleshoot disturbances in the power system such as voltage sags, swells, transients, harmonics, flicker, unbalance, and frequency deviations. These analyzers are equipped with high-speed sampling capabilities, waveform capture, and harmonic spectrum analysis tools, making them ideal for identifying and resolving issues that can affect the performance or lifespan of sensitive electrical equipment. They are also commonly used for compliance monitoring against standards like EN 50160 or IEEE 519. In contrast, a Power Recorder is primarily used for long-term logging of power parameters such as voltage, current, power (kW, kVA, kVAR), and energy consumption. Its focus is more on load studies, energy audits, and identifying usage patterns over time rather than real-time disturbances or quality issues. Power Recorders usually measure and log RMS values at set intervals and are not typically equipped to detect fast transients, harmonics, or waveform-level events. While some overlap exists—many modern Power Quality Analyzers also offer recording functionality—the key difference lies in the depth of analysis. A Power Quality Analyzer is a diagnostic tool used when there’s a suspected problem or for verifying power quality compliance, whereas a Power Recorder is more of a monitoring tool for tracking energy use and system loading trends over time. 04 How Harmonics Affect Transformer Performance? Effects of Harmonics on Transformer Performance Increased Heating (Core and Copper Losses): Harmonics cause additional eddy current and hysteresis losses in the transformer core and I²R losses in the windings due to the skin effect and proximity effect. This leads to excessive heating, even when the transformer is operating within its rated current. This can reduce transformer lifespan or even cause thermal failure. Reduced Efficiency: As harmonic losses increase, the overall efficiency of the transformer drops. It may appear to be operating under normal conditions in terms of RMS values, but real power losses are higher. Derating of Transformer: To compensate for the increased losses due to harmonics, transformers are often derated (i.e., used at less than their nameplate capacity) when supplying non-linear loads. IEEE Std C57.110 provides guidelines for calculating the required derating. Increased Vibration and Noise: Harmonics can cause magnetostriction effects in the transformer core, resulting in audible noise and mechanical vibration, which can be especially problematic in sensitive environments. Insulation Stress and Aging: Repeated thermal cycling due to harmonic-induced heating stresses the insulation system, accelerating insulation degradation and reducing transformer life expectancy. Neutral Overload (in 3-phase systems): In systems with significant triplen harmonics (3rd, 9th, 15th...), these components add arithmetically in the neutral conductor. This can cause the neutral to overheat, even if the phase conductors are within limits. Incorrect Protective Relay Operation: Harmonic distortion can interfere with current and voltage sensing used in protective relays, leading to nuisance tripping or failure to trip during faults. 05 What are Real-World Applications of PQ Recorders? Real-World Applications of Power Quality (PQ) Recorders 1. Load Profiling and Energy Audits PQ recorders are commonly used to monitor energy consumption patterns over time. This helps identify peak demand periods, base loads, and inefficiencies, supporting energy optimization and cost savings. 2. Electrical System Commissioning During commissioning of new installations—such as switchboards, transformers, or generators—PQ recorders verify voltage levels, current balance, and overall system performance to ensure proper operation. 3. Capacity Planning and Expansion Before adding new electrical loads, PQ recorders assess whether existing infrastructure can support the additional demand. This prevents overloading and supports informed upgrade decisions. 4. Renewable Energy Integration In solar and wind power systems, PQ recorders monitor output stability, voltage, and frequency to ensure grid compliance and smooth integration with the main supply. 5. Troubleshooting Intermittent Issues When power issues such as flickering, nuisance tripping, or undervoltage occur, PQ recorders help log and analyze events that may not be immediately visible during spot checks. 6. Utility Billing Verification PQ recorders provide accurate data for verifying utility charges, particularly demand-based billing and power factor penalties, helping avoid disputes or overcharges. 7. Temporary Power Monitoring For construction sites, events, or mobile power setups, PQ recorders ensure temporary supplies are stable, safe, and suitable for operational requirements. 8. Preventive Maintenance and Trend Analysis Long-term monitoring enables early detection of issues like increasing unbalance or loading trends, allowing for proactive maintenance before failures occur. 06 What are the Benefits of 24/7 Power Quality Monitoring? Benefits of 24/7 Power Quality Monitoring : 1. Continuous Visibility Real-time tracking of voltage, current, harmonics, and disturbances ensures you always have a clear picture of system health — without waiting for issues to escalate. 2. Early Fault Detection Continuous monitoring helps detect developing issues like transformer overload, harmonic distortion, or voltage imbalance before they cause damage or downtime. 3. Minimizes Unplanned Downtime By identifying power disturbances early, 24/7 PQ monitoring reduces the risk of equipment failure, production loss, or service interruption. 4. Improves Equipment Lifespan Stable power quality reduces stress on motors, drives, UPS systems, and sensitive electronics — extending their service life and reducing maintenance costs. 5. Supports Root Cause Analysis Historical event logs and waveform captures make it easier to trace the cause of faults, helping engineers respond faster and more accurately. 6. Compliance & Reporting Automated recording helps meet regulatory standards (e.g., EN 50160, IEEE 519) and supports internal audits or external quality reports. 7. Energy Efficiency Optimization By continuously monitoring power factor, load balance, and harmonic content, users can implement corrective actions to reduce losses and improve system efficiency. 8. Informs Investment Decisions Reliable long-term data helps justify infrastructure upgrades, sizing of backup systems, or addition of filters and stabilizers.
- Servicesupport
In KPM Engineering Solution Pvt. Ltd our solutions are Thermal Imager camera, fever monitoring solution, Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing , Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing. Visit www.kpmtek.com for details Technical support and services Localized Service Center A Key to Success for Hi-Tech Equipment Providers Relay Test Kits CT/PT Analyzers Tan Delta Kits And other advanced diagnostic instruments. With local spare parts availability, we ensure fast turnaround times and reliable repairs, resulting in minimal downtime and maximum customer satisfaction. At KPM, we believe that a localized service center is crucial to the success of any high-tech equipment provider. We take pride in operating a state-of-the-art service center with over 10 years of experience in the repair and maintenance of critical testing equipment, including: Contact Us
- TrustShield | KPM India |TrustShield
Each product supplied by KPM undergoes a series of lab & field testing trials. Performance of equipment is closely monitored in rigorous field trials under stringent conditions. Once the equipment passes through these trials, then it is launched in the market . Trust Shield is an initiative to quantify the testing outcomes. Trust shield is a way to impart transparency to customer's purchase process. ESCUDO DE CONFIANZA DE KPM One estrella Equipo con 1 estrella Satisface por debajo del rendimiento requisitos Más de 20 pruebas de campo en condiciones del sitio Más de 100 ensayos de prueba en condiciones de laboratorio Comprobado en el mercado durante < 3 años En todos los requisitos anteriores, el rendimiento del producto se supervisa sobre la base de: Confiabilidad Repetibilidad Precisión Desempeño contra el efecto del ruido (Conectores EHV en vivo) Robustez durante el viaje, etc. dos estrella Equipo con 2 estrellas Satisface por debajo del rendimiento requisitos Más de 50 pruebas de campo en condiciones del sitio Más de 100 ensayos de prueba en condiciones de laboratorio Comprobado en el mercado durante más de 3 años En todos los requisitos anteriores, el rendimiento del producto se supervisa sobre la base de: Confiabilidad Repetibilidad Precisión Desempeño contra el efecto del ruido (Conectores EHV en vivo) Robustez durante el viaje, etc. tres estrella Equipo con 3 estrellas Satisface por debajo del rendimiento requisitos Más de 50 pruebas de campo en condiciones del sitio Más de 100 ensayos de prueba en condiciones de laboratorio Comprobado en el mercado durante más de 7 años En todos los requisitos anteriores, el rendimiento del producto se supervisa sobre la base de: Confiabilidad Repetibilidad Precisión Desempeño contra el efecto del ruido (Conectores EHV en vivo) Robustez durante el viaje, etc. CUÁL ES LA RELEVANCIA DE " TRUST SHIELD " Cada producto suministrado por KPM se somete a una serie de pruebas de laboratorio y de campo. El rendimiento del equipo se supervisa de cerca en rigurosas pruebas de campo en condiciones estrictas. Una vez que el equipo pasa por estas pruebas, se lanza al mercado. Trust Shield es una iniciativa para cuantificar los resultados de las pruebas. Trust Shield es una forma de impartir transparencia al proceso de compra del cliente. ¿Significa que 3 estrellas es mejor que 2 estrellas? Sí y no, cualquier equipo con un KPM TRUST SHIELD de 2 estrellas puede ser tan bueno como un equipo de 3 estrellas. número de ensayos de laboratorio. La calificación de estrellas de KPM TRUST SHIELD también depende del período de tiempo durante el cual el equipo funciona en el campo en términos de robustez y confiabilidad. Cualquier producto de 2 estrellas también puede caer en la calificación de 3 estrellas si funciona de manera constante durante más de 7 años.
- Partial Discharge Testing Equipment by KPM | PD Diagnostics|Partial Discharge
Advanced partial discharge testing equipment by KPM for precise detection, insulation analysis, and condition monitoring of electrical assets. MONITOREO EN LÍNEA DE PD Y TIERRA KPM PENTA PD (HAND HELD) View more Partial Discharge Detector Penta-PD is an ideal partner for condition-based maintenance programs. Partial Discharge Detector Penta-PD incorporates all 5 types of online PD sensor technology. Information from multiple sensors gives Partial Discharge Detector Penta-PD the versatility to detect various type PD in variety of substation apparatus. KPM PDM-01,Partial Discharge Monitor View more The KPM PDM-01 partial discharge detector stands out as a versatile digital tool within KPM's product range. Featuring a 10.1-inch touch screen, it replaces the traditional oscilloscope tube and physical knob operation, enhancing user convenience. The instrument employs a full touch screen interface, contributing to extended product longevity and incorporates useful features such as automatic correction, high voltage divider ratio settings, and serial communication for uploading test data. KPM PDTI Cable Termination Monitor View more The KPM PDTI system is deployed on primary switching equipment such as ring network switch cabinets, cable termination boxes, and transformer output cables etc. within the power distribution network. Its primary function is to conduct online monitoring of partial discharge, indicating potential short circuits and ground faults in corresponding cable sections, along with real-time temperature monitoring. KPM Corona Pointer View more KPM Corona Pointer is an ideal equipment for condition-based maintenance programs. Online partial discharge testing is a method of inspecting the insulation of electric power systems while equipment remains energized and in service. Corona Pointer is based on online Ultrasonic PD sensor technology. KPM Duo PD - Handheld PD monitoring system View more KPM Duo PD is a handheld partial discharge tester which uses the ultrasonic signal generated by partial discharge to determine the existence and location of partial discharge and combines the real-time displayed images and data to quickly diagnose partial discharge conditions. KPM PDA-01, Partial Discharge Monitor View more The KPM PDA-01 features a split, modular design, with the local discharge signal conditioning module, digital acquisition module, and test voltage acquisition module integrated into the instrument. The powerful local discharge test and analysis system software is installed on the host computer, which connects to the instrument via USB and RS232 serial ports. KPM PD Pulse-8, Online Partial Discharge Monitor View more KPM PD Pulse-8 partial discharge online monitoring device includes a modularly designed partial discharge sensor and a partial discharge data processing terminal. The partial discharge sensor can effectively monitor ultrasonic and transient earth voltage signals. Its sensors are a two-in-one integrated assembly that can be installed on the HV equipment. Preguntas frecuentes (FAQ) FAQ about Partial discharge : 01 What is partial discharge? Partial discharge (PD) is a small electrical spark that bridges only part of the insulation between two conductors at different voltages. The insulation as a whole still holds, but at one weak spot the local electric field is high enough to break down a tiny gap, a gas bubble or a surface path.Each discharge lasts a fraction of a microsecond and carries a minute charge. It repeats every power cycle, though, often thousands of times a second, and over months or years that repeated attack erodes the insulation around it. 02 Why is partial discharge dangerous for high-voltage equipment? Partial discharge is both a symptom and a cause. It shows that the insulation has a defect, and it makes that defect worse. Each discharge damages the material by heat, chemical attack and erosion, and the damaged region grows.In solid insulation, that can lead to electrical treeing and eventually a full breakdown: a flashover or fault that can destroy switchgear, a cable joint or a transformer and cause an unplanned outage. Partial discharge is one of the most common forms of deterioration in medium- and high-voltage insulation, so finding it early is one of the most effective ways to prevent failures. 03 Where does partial discharge occur in electrical equipment? • Internal discharge: in voids, cracks or delaminations inside solid insulation such as cast resin, cable insulation or bushings.• Surface discharge: along an insulating surface that is contaminated, damp or overstressed, for example on bushings, terminations and insulator surfaces inside switchgear.• Corona: in air or gas around sharp edges and points at high voltage.• Floating potential: from a metal part that has lost its connection and charges up to an intermediate voltage.• Free particles: loose metal particles moving in gas-insulated equipment.Each type produces a characteristic pattern relative to the power-frequency voltage, which is how an experienced analyst tells them apart. 04 What is the difference between partial discharge and corona? Corona is one type of partial discharge: discharge in air or gas around a sharp conductor at high voltage, with no solid insulation involved. On overhead lines and in outdoor substations some corona is normal and often harmless, apart from radio interference and power loss.Partial discharge is the wider term. It also covers discharge inside solid insulation and along insulating surfaces, which is much more damaging. Telling corona apart from internal or surface discharge is an important part of interpreting any PD test. 05 What is the difference between online and offline partial discharge testing? Online testing is done with the equipment energised and in normal service. Sensors pick up the signals that partial discharge sends out, with no outage and no extra high-voltage supply. It is ideal for surveys and condition monitoring.Offline testing is done with the equipment disconnected and energised from a separate test source. It allows the voltage to be controlled and the discharge to be measured in calibrated units, which is why it is used for factory acceptance tests and detailed diagnostics. It needs an outage and more equipment. 06 What is IEC 60270 partial discharge measurement? IEC 60270 is the international standard for the conventional, electrical measurement of partial discharge. It uses a coupling capacitor and a measuring circuit, calibrated by injecting a known charge, and reports the apparent charge of the discharges in picocoulombs (pC).It is the method used in factory acceptance tests and in equipment standards that set a pC limit. Most portable online PD testers use non-conventional methods instead (electromagnetic and acoustic sensors, covered in IEC TS 62478), which do not give a pC value but can test equipment in service. 07 How is partial discharge detected? A partial discharge releases energy in several forms, and each can be detected:• An electromagnetic pulse, picked up as transient earth voltage (TEV) on metal enclosures, or as UHF radio waves.• Sound, mostly ultrasonic, picked up through the air or through the enclosure wall.• A current pulse flowing to earth, picked up with a high-frequency current transformer (HFCT) on an earth connection.• Light, heat and chemical by-products, used in some specialised methods.The best method depends on the equipment and on which of these signals can reach the outside of it.Picture filepd-signals-and-detection-methods.pngAlt textDiagram of the signals a partial discharge gives off and the sensor that detects each: TEV, ultrasonic, UHF and HFCTCaptionOne discharge, four kinds of signal, four ways to detect it. 08 What is KPMs TEV (transient earth voltage) partial discharge testing? When partial discharge occurs inside metal-clad switchgear, it sends out a fast electromagnetic pulse. Most of it stays inside the metal enclosure, but some escapes through joints, gaskets and openings and induces a very short voltage pulse on the outer surface of the enclosure. That pulse is the transient earth voltage.A TEV sensor is a capacitive probe held against the outside of the panel. TEV testing is quick, needs no outage and is one of the main methods for surveying medium-voltage switchgear and ring main units. 09 What is KPMs UHF partial discharge detection? Partial discharge in gas or solid insulation produces extremely fast current pulses, with rise times of around a nanosecond, which radiate electromagnetic waves up into the ultra-high-frequency range, from hundreds of megahertz to a few gigahertz.UHF sensors pick up these signals. The method is widely used for gas-insulated switchgear (GIS), where sensors are placed at insulating spacers or inspection windows, and for transformers fitted with UHF sensor ports. Working at these frequencies avoids most corona in air and low-frequency noise, although radio sources in the same band, such as mobile phones and Wi-Fi, can still interfere. 10 How is partial discharge detected in power cables? Along most of a cable's length, metal screens, armour and burial stop electromagnetic and acoustic signals from being picked up outside. A discharge does, however, send current pulses along the cable screen to earth. (At terminations inside switchgear and at exposed cable boxes, TEV, ultrasonic and UHF sensors can also help.)A high-frequency current transformer (HFCT), a clamp-on sensor, placed around the earth connection of a cable termination or joint picks up those pulses. Online cable PD testing with HFCTs is common at terminations, in substations and at link boxes. 11 Is a handheld partial discharge tester the same as continuous PD monitoring? No. A handheld PD tester gives a snapshot: an engineer visits, measures and records. It is ideal for surveying many assets quickly and checking equipment periodically.Continuous monitoring uses permanently installed sensors and records partial discharge all the time. It is used on critical or known-suspect assets where activity may come and go with load, temperature or humidity.Many asset owners combine them: periodic handheld surveys across the network, and continuous monitoring where a survey finds something worth watching closely. 12 Why measure background levels before a KPM partial discharge test? Every PD reading has to be judged against the background: the signal level present even where there is no discharge. A high background can hide real discharge, or make a healthy panel look suspect.Electromagnetic interference affects TEV and UHF readings, and other noise sources affect ultrasonic readings. Measuring the background first tells you how much of each reading is genuine, and whether conditions are good enough to test at all. 13 Does humidity or temperature affect partial discharge readings? Yes. Surface discharge in particular is strongly affected by humidity and condensation: it can be active on a damp morning and quiet in the afternoon. Load and temperature also change discharge activity in cables and transformers.Always record the ambient conditions with every test, and compare surveys taken in similar conditions where possible. Discharge that appears only in damp weather still points to a real problem, often surface contamination or poor sealing. 14 What is a PRPD pattern? A PRPD (phase-resolved partial discharge) pattern plots each detected discharge pulse by its amplitude and by the point in the power-frequency cycle (0° to 360°) at which it occurred, accumulated over many cycles.Different defects discharge at characteristic points in the voltage cycle, so the shape of the pattern is a fingerprint. Internal discharge, surface discharge, corona and floating parts each tend to produce a recognisable pattern, while most random noise does not line up with the voltage cycle. Interference from power electronics is an exception: it is locked to the supply and appears at fixed points in the cycle, so it has to be recognised and excluded. PRPD analysis is the standard way of identifying what kind of discharge is present.Picture filepd-idealised-prpd-patterns.pngAlt textIdealised textbook sketches of phase-resolved partial discharge (PRPD) patterns for internal discharge, corona and noiseCaptionSimplified textbook sketches, not instrument screens. Real patterns vary with the equipment and the measurement. 15 What do dB, dBmV and dBµV mean in KPM partial discharge testing? Partial discharge signals vary over a very wide range, so many instruments show them on a logarithmic decibel (dB) scale.• dBmV is relative to 1 millivolt, often used for TEV readings. UHF readings are often given in dBm, relative to 1 milliwatt.• dBµV is relative to 1 microvolt, often used for ultrasonic readings.Every 20 dB is a tenfold increase in signal amplitude, so a reading 20 dB higher than another is ten times larger, and 40 dB higher is a hundred times larger. FAQ about Monitoring testing : 01 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? Using both TEV and ultrasonic methods together enhances diagnostic accuracy: TEV gives insight into internal discharge severity and location. Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. This dual-method approach is vital for: Preventive maintenance, Avoiding insulation failures, Improving switchgear reliability, and Extending equipment life without needing shutdowns.
- KPM Transformer Oil Testing | Oil Analysis & Diagnostics|Transformer Oil Testing
Advanced transformer oil testing by KPM for precise oil analysis, insulation assessment, and efficient transformer maintenance. EQUIPO DE LABORATORIO DE PRUEBA DE ACEITE PROBADOR DEL PUNTO DE INFLAMACIÓN (KPM OT 01) Ver más El probador de punto de inflamación de aceite de transformador de copa cerrada KPM OT 01 es un probador automático de punto de inflamación cerrado. Se utiliza para medir el punto de inflamación abierto y cerrado de productos derivados del petróleo. Parámetros técnicos-: 1. Medición de temperatura Rango de medición de temperatura: -59,9 °C~299,9 °C Rango de control de temperatura: temperatura ambiente ~ 300 ° C Repetibilidad: 0.025X (x = valor promedio de prueba dos veces sucesivas) Resolución: 0.1°C Precisión: 0,5% Sensor de temperatura: resistencia de platino (PT100) Sensor de fuego relámpago: anillo de detección de iones 2. Temperatura ambiente: 0 ~ 40 °C 3. Humedad relativa: ≤ 85 % de humedad relativa 4. Fuente de alimentación: AC220V ± 20%; 50Hz ± 10% 5. Consumo de energía: aproximadamente 400W PROBADOR DEL PUNTO DE INFLAMACIÓN (KPM OT 01) Ver más El probador de punto de inflamación de aceite de transformador de copa cerrada KPM OT 01 es un probador automático de punto de inflamación cerrado. Se utiliza para medir el punto de inflamación abierto y cerrado de productos derivados del petróleo. Parámetros técnicos-: 1. Medición de temperatura Rango de medición de temperatura: -59,9 °C~299,9 °C Rango de control de temperatura: temperatura ambiente ~ 300 ° C Repetibilidad: 0.025X (x = valor promedio de prueba dos veces sucesivas) Resolución: 0.1°C Precisión: 0,5% Sensor de temperatura: resistencia de platino (PT100) Sensor de fuego relámpago: anillo de detección de iones 2. Temperatura ambiente: 0 ~ 40 °C 3. Humedad relativa: ≤ 85 % de humedad relativa 4. Fuente de alimentación: AC220V ± 20%; 50Hz ± 10% 5. Consumo de energía: aproximadamente 400W PROBADOR DE VISCOSIDAD (KPM OT O3) Ver más La viscosidad cinemática es la medida de la fuerza de fricción interna cuando el líquido fluye bajo la acción de la gravedad, y su valor es la relación entre la viscosidad dinámica y la densidad a la misma temperatura, que es una de las propiedades físicas y químicas importantes de identificación del grado y la calidad del aceite. En la aplicación práctica, la selección adecuada de la viscosidad del aceite lubricante puede garantizar el funcionamiento normal y fiable de los equipos mecánicos. KPM OT 03 es el equipo de prueba especial diseñado y fabricado en base a las normas nacionales/normas internacionales. KPM OT 03 es adecuado para la determinación de la viscosidad cinemática de productos petrolíferos líquidos. El instrumento tiene una función de temporizador del tiempo de movimiento de la muestra y una función de cálculo automático de los resultados finales de la viscosidad cinemática. Características del instrumento probador de viscosidad cinemática ◆La constante del viscosímetro, el valor de control de temperatura, la temperatura de ajuste fino, el número de pruebas y otros parámetros se pueden configurar mediante el teclado, el instrumento tiene una función de memoria para guardar el conjunto de datos automáticamente la primera vez ◆Adoptar sensor importado y nueva tecnología de control de temperatura de ajuste automático PID digital, que tiene un amplio rango de control de temperatura y alta precisión de control de temperatura ◆El reloj calendario no se apaga y muestra la hora actual automáticamente cuando se inicia ◆Función alternativa de comunicación en red, control remoto, tabulación ◆Botón sin marcas, el funcionamiento es intuitivo y sencillo. ◆El número de tiempo de experimento es de 1 a 6 veces, lo cual es ajustable y conveniente ◆El registro experimental se puede guardar para verlo más tarde. Probador de viscosidad cinemática Parámetros técnicos ◆ Agujero de baño líquido: 4 agujeros ◆Rango de control de temperatura: temperatura ambiente —120 ℃ ◆ Precisión de control de temperatura: ≤ ± 0,01 ℃ ◆Potencia de calefacción: 1000W ◆Tiempos de prueba: 1 a 6 veces, ajustable TAN DELTA DE ACEITE ( KPM OTD 01 ) Ver más KPM OTD01 is used for measuring dielectric dissipation_cc781905 -5cde-3194-bb3b-136bad5cf58d_factor and DC resistivity of insulating oil_cc781905 -5cde-3194-bb3b-136bad5cf58d_and other aislantes líquidos._cc781905-5cde-3194-bb3b5cf-1586d_bad KPM OTD01 en un probador de resistividad y pérdida dieléctrica de aceite aislante de limpieza automática 1.Oil cup is cleaned automatically and_cc781905-5cde-3194-bb3b- 136bad5cf58d_has electrode calibración función._cc781905-5cde-31936-bad3bcf-5 2. Internal standard capacitor electrode type_cc781905-5cde-3194-bb3b- 136bad5cf58d_condensador,con electrode spacing 2mm. 3.Large-screen LCD,backlight, display is clear._cc781905-5cde-3194-bb3b- 136malo5cf58d_ 4.More accurate. Testing AC power supply_cc781905-5cde-3194- bb3b-136bad5cf58d_adopts AC - DC -_cc781905-5cde-3194 -bb3b-136bad5cf58d_AC conversion method. 5.Equipped with overvoltage, overcurrent and limit_cc781905-5cde-3194- bb3b-136bad5cf58d_ protecciones. 6.Measured temperature and system clock. _cc781905-5cde-3194- bb3b-136bad5cf58d_ Technical Parámetros Alimentación Voltage : AC 220V±10% Potencia Frecuencia: 50Hz/60Hz ±1% Medición Rangecapacitancia: 5pF~200pF relativa permitividad: 1.000~30.000 dielectric dissipation factor : 0.00001~100 DC Resistividad: 2,5 MΩm~20 TΩm Medición Capacidad de precisión: ±(1 % de lectura+0,5 pF) relativa permitividad: ±1% lectura dielectric dissipation factor : ±(1% reading +0.0001) DC Resistividad: ±10 % lectura Resolution Relación de capacitancia: 0.01pF relativo permitividad: 0,001 dielectric dissipation factor : 0.00001 Temperatura Rango: 0~125℃ Thermometric Error: ±0,5 ℃ AC testing voltage : 500 ~ 2200V adjustable,_cc781905-5cde- 3194-bb3b-136bad5cf58d_frequency 50 HZ DC testing voltage : 0 ~ 500V adjustable Potencia Disipación: 100w Límite Dimensión: 500 mm * 360 mm * 420 mm Peso : 22kg PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DEL PUNTO DE INFLAMACIÓN (KPM OT 01) Ver más El probador de punto de inflamación de aceite de transformador de copa cerrada KPM OT 01 es un probador automático de punto de inflamación cerrado. Se utiliza para medir el punto de inflamación abierto y cerrado de productos derivados del petróleo. Parámetros técnicos-: 1. Medición de temperatura Rango de medición de temperatura: -59,9 °C~299,9 °C Rango de control de temperatura: temperatura ambiente ~ 300 ° C Repetibilidad: 0.025X (x = valor promedio de prueba dos veces sucesivas) Resolución: 0.1°C Precisión: 0,5% Sensor de temperatura: resistencia de platino (PT100) Sensor de fuego relámpago: anillo de detección de iones 2. Temperatura ambiente: 0 ~ 40 °C 3. Humedad relativa: ≤ 85 % de humedad relativa 4. Fuente de alimentación: AC220V ± 20%; 50Hz ± 10% 5. Consumo de energía: aproximadamente 400W KARL FISCHER (KPM OT 02) Ver más Valorador Karl Fischer KPM OT 02 is suitable in determining water content in_cc781905-5cde-3194- bb3b-136bad5cf58d_the liquid petroleum products by titration using_cc781905- 5cde-3194-bb3b-136bad5cf58d_Karl Fischer reagent. It adopts a microprocessor for control, so_cc781905-5cde- 3194-bb3b-136bad5cf58d_it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It_cc781905-5cde-3194- bb3b-136bad5cf58d_also has function of self-diagnostics, menu_cc781905-5cde- 3194-bb3b-136bad5cf58d_selection. It is a multifunctional, convenient, and automatic analysis_cc781905-5cde-3194-bb3b5-cf58d_instrumento. Titulador volumétrico de humedad Karl Fischer Technical parameters: 1 Method Karl Fischer Coulometric Titrator_cc781905-5cde-3194-bb3b- 136bad5cf58d_Principio 2 Tipo Portátil 3 Medición Range 0ug-100mg 4 Resolución 0.1ug 5 the Largest Electrolytic Speed 40_cc781905-5cde-3194-bb3b- 136bad5cf58d_ug/s 6 Power Supply Voltage AC220V ±20%(_cc781905-5cde -3194-bb3b-136bad5cf58d_personalización) 7 Mayor power 30w 8 Work Temperature 10~35℃ 9 Trabajo Humedad ≤85 % 10 Dimensiones 320*240*150mm 11 Peso 5kg TAN DELTA DE ACEITE ( KPM OTD 01 ) Ver más KPM OTD01 is used for measuring dielectric dissipation_cc781905 -5cde-3194-bb3b-136bad5cf58d_factor and DC resistivity of insulating oil_cc781905 -5cde-3194-bb3b-136bad5cf58d_and other aislantes líquidos._cc781905-5cde-3194-bb3b5cf-1586d_bad KPM OTD01 en un probador de resistividad y pérdida dieléctrica de aceite aislante de limpieza automática 1.Oil cup is cleaned automatically and_cc781905-5cde-3194-bb3b- 136bad5cf58d_has electrode calibración función._cc781905-5cde-31936-bad3bcf-5 2. Internal standard capacitor electrode type_cc781905-5cde-3194-bb3b- 136bad5cf58d_condensador,con electrode spacing 2mm. 3.Large-screen LCD,backlight, display is clear._cc781905-5cde-3194-bb3b- 136malo5cf58d_ 4.More accurate. Testing AC power supply_cc781905-5cde-3194- bb3b-136bad5cf58d_adopts AC - DC -_cc781905-5cde-3194 -bb3b-136bad5cf58d_AC conversion method. 5.Equipped with overvoltage, overcurrent and limit_cc781905-5cde-3194- bb3b-136bad5cf58d_ protecciones. 6.Measured temperature and system clock. _cc781905-5cde-3194- bb3b-136bad5cf58d_ Technical Parámetros Alimentación Voltage : AC 220V±10% Potencia Frecuencia: 50Hz/60Hz ±1% Medición Rangecapacitancia: 5pF~200pF relativa permitividad: 1.000~30.000 dielectric dissipation factor : 0.00001~100 DC Resistividad: 2,5 MΩm~20 TΩm Medición Capacidad de precisión: ±(1 % de lectura+0,5 pF) relativa permitividad: ±1% lectura dielectric dissipation factor : ±(1% reading +0.0001) DC Resistividad: ±10 % lectura Resolution Relación de capacitancia: 0.01pF relativo permitividad: 0,001 dielectric dissipation factor : 0.00001 Temperatura Rango: 0~125℃ Thermometric Error: ±0,5 ℃ AC testing voltage : 500 ~ 2200V adjustable,_cc781905-5cde- 3194-bb3b-136bad5cf58d_frequency 50 HZ DC testing voltage : 0 ~ 500V adjustable Potencia Disipación: 100w Límite Dimensión: 500 mm * 360 mm * 420 mm Peso : 22kg PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W PROBADOR DE VALOR ACIDO ( KPM OT 05 ) Ver más La acidez del aceite de transformador es una propiedad nociva. Si el aceite se vuelve ácido, el contenido de agua en el aceite se vuelve más soluble en el aceite. La acidez del aceite deteriora la propiedad de aislamiento del aislamiento de papel del devanado. La acidez acelera el proceso de oxidación del aceite. El ácido también incluye la oxidación del hierro en presencia de humedad. The acidity of transformer oil is medida de sus constituyentes ácidos de contaminantes. La acidez del aceite se expresa en mg de KOH necesarios para neutralizar el ácido presente en un gramo de aceite. Esto también se conoce como número de neutralización. KPM OT 05 es un probador de valor de ácido automático con las siguientes características: Utilidad multifunción: puede probar el valor de ácido del aceite del transformador, aceite de turbina y aceite combustible. equipado con ácido estándar y procedimientos de calibración Completamente automatico microimpresora pantalla LCD Alta precisión Operación fácil Technical Parámetro: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 -bb3b-136bad5cf58d_of transformer oil Prueba Range 0.001~1mg KOH/g Error ≤±0.001mg KOH/g Repetibilidad ≤0.002mg KOH/g Temperatura 10°c~45°c Humedad ≤85 % de HR Alimentación Supply CA 220 V/50 HZ Potencia 500W Kit de prueba de aceite BDV (OBD 100A+) Ver más Como sugiere el nombre, el equipo de prueba Oil BDV (KPM-OBD100A+) se utiliza para medir la resistencia a la ruptura del aceite aislante. Capaz de generar 80/100 KV con impresora integrada. Agitador motorizado y programado Peso ligero 0.5KV/sec to 5KV/sec variable voltage rise as per ASTM Standards ( available in "A+"_cc781905-5cde-3194-bb3b- 136bad5cf58d_ modelos) Kit de prueba de aceite BDV (OBD 100+) Ver más Como sugiere el nombre, el juego de prueba Oil BDV (KPM-OBD 100+) se utiliza para medir la resistencia a la ruptura del aceite aislante. Capaz de generar 80/100 KV con impresora integrada. Agitador motorizado y programado Peso ligero Aumento de voltaje de 2 KV/s con planes de prueba automáticos según IEC e IS Preguntas frecuentes (FAQ) FAQ about Oil testing : 01 How to Perform a Reliable 10kV Insulation Test? A 10kV insulation resistance test is used to evaluate the dielectric strength of high-voltage equipment like transformers, motors, and cables. To perform it reliably, first de-energize and isolate the equipment, ensuring it's properly grounded. Clean terminals to remove surface contamination. Connect the insulation tester leads: One to the conductor and the other to ground. Select the 10kV test voltage on the insulation resistance tester. Begin the test and monitor resistance for 1 to 10 minutes—longer durations help identify moisture or insulation defects. Readings should be in the GΩ (giga ohm) range for healthy insulation. Apply DAR (Dielectric Absorption Ratio) or PI (Polarization Index) analysis to assess insulation aging. Ensure environmental conditions are dry and free of electrical noise for accuracy. KPM provides high-voltage insulation testers with digital displays, timer functions, and built-in safety features, ensuring accurate, safe, and standards-compliant insulation testing across utility and industrial applications. 02 Differences Between 5kV, 10kV, and 15kV Insulation Testers? The main difference between 5kV, 10kV, and 15kV insulation testers lies in their test voltage output, which determines the type of equipment they are suited for and the depth of insulation assessment they provide. 5kV testers are typically used for low to medium voltage equipment like motors, cables, and switchgear up to 25kV. 10kV testers are suitable for higher-voltage systems such as power transformers, HV motors, and cables rated up to 69kV, providing a deeper insulation profile. 15kV testers are used for critical high-voltage assets above 69kV, enabling detection of insulation weaknesses that lower voltages may miss. Higher voltage testers stress insulation more, revealing latent defects and moisture absorption. However, using too high a voltage on low-rated equipment can cause damage. KPM offers 5kV, 10kV, and 15kV insulation testers with digital readings, polarization index (PI), and DAR calculations, ideal for field diagnostics and predictive maintenance. 03 What is Karl Fischer Titration ? Explain Moisture Testing in Oil. Karl Fischer (KF) titration is a precise chemical method used to measure moisture content (water) in substances, including insulating oils, with accuracy down to parts per million (ppm). It's the preferred method for transformer oil and lubricants because even trace moisture can degrade dielectric strength, cause corrosion, or affect equipment performance. How It Works: KF titration is based on a chemical reaction where iodine reacts with water in the presence of sulfur dioxide and alcohol, using a base (often imidazole or pyridine) as a catalyst: This reaction occurs until all water is consumed. The amount of iodine used is directly proportional to the moisture present. Types of KF Titration: Volumetric KF: For water content above 1%. Common in oil testing. Coulometric KF: For ultra-low moisture (<1%), generating iodine electrochemically. Advantages: Highly accurate (1–10 ppm range). Specific to water (no interference from other volatiles). Widely accepted in ASTM D1533 for transformer oil testing. KPM supplies Karl Fischer titrators for both volumetric and coulometric methods, used in power utilities and oil testing labs to ensure insulation oils remain within safe moisture limits. 04 How to Identify Oil Contamination Using BDV Testers? Breakdown Voltage (BDV) testing is a key method to identify contamination in insulating oils used in transformers, circuit breakers, and other high-voltage equipment. A BDV tester applies a gradually increasing AC voltage to a sample of insulating oil placed between two standard electrodes. Clean, dry oil has high dielectric strength and resists electrical breakdown. However, the presence of moisture, dissolved gases, carbon particles, or sludge lowers the breakdown voltage significantly. Typically, good transformer oil should withstand 30 kV or more in a 2.5 mm electrode gap. A low BDV reading (e.g., below 20 kV) suggests contamination. Multiple test cycles (usually 5–6) help eliminate anomalies and confirm consistency. KPM provides automated and manual BDV testers with features like automatic voltage ramping, stirrers for even testing, digital displays, and built-in standards (IEC 60156, ASTM D1816), ensuring accurate detection of oil contamination and timely maintenance planning. 05 What is Viscosity and Pour Point in Transformer Oils? Viscosity is the measure of a fluid's resistance to flow. In transformer oils, optimal viscosity is crucial for: Heat transfer: Low viscosity allows better circulation and cooling. Lubrication: Protects internal parts from wear. Pump efficiency: Thinner oil reduces mechanical stress on pumps. High viscosity at low temperatures can hinder oil movement, reducing cooling and increasing risk of overheating. Transformer oils typically have a viscosity range of 8–12 cSt at 40°C, as per IEC and ASTM standards. Pour Point: Pour point is the lowest temperature at which oil still flows. It indicates how oil behaves in cold environments. A low pour point ensures the oil remains pumpable and circulates properly during cold starts or winter operation. A good transformer oil has a pour point below -30°C, as per ASTM D97 or ISO 3016. KPM provides viscosity and pour point testing kits and services compliant with ASTM D445 and D97, ensuring transformer oil meets safety and performance standards. 06 What is Flash Point Testing? What are its Safety Standards and Applications? Flash point testing determines the lowest temperature at which a liquid emits enough vapor to ignite in the presence of an ignition source. It is a critical parameter for assessing the fire and explosion risk of flammable and combustible liquids such as fuels, lubricants, and transformer oils. This test ensures the safe handling, storage, and transportation of these substances. Globally recognized standards such as ASTM D93 (Pensky-Martens Closed Cup), ISO 2719, and ASTM D56 (Tag Closed Tester) provide standardized methods to ensure consistency and safety. Applications span industries like petrochemicals, energy, pharmaceuticals, and aviation, where accurate flash point data is essential for risk assessments, regulatory compliance, and material classification. KPM ensures strict adherence to international safety standards by offering flash point testers that comply with ASTM D93, ISO 2719, and related norms. KPM’s equipment features precision temperature control, sealed test chambers, and automation to eliminate user error. These instruments are calibrated and validated regularly to maintain measurement integrity. Additionally, KPM provides comprehensive support, including training and servicing, to ensure customers conduct testing safely and accurately. By aligning with global testing protocols, KPM plays a key role in advancing operational safety and regulatory compliance across 07 What is Oil Tan Delta? Also understanding Dielectric Loss. Tan Delta, also known as the dissipation factor, is a key parameter used to evaluate the dielectric loss in insulating oils. It represents the ratio of the resistive current to the capacitive current within the oil when subjected to an alternating electrical field. It measures the inefficiency or energy loss in the insulation system when subjected to an alternating electric field. A low Tan Delta value indicates good insulation quality with minimal dielectric loss, while a high value suggests aging, moisture contamination, or deterioration of the insulating oil. Tan delta testing is a crucial diagnostic tool for assessing the health of insulating oil. By understanding the relationship between tan delta, dielectric loss, and the condition of the oil, maintenance professionals can take steps to ensure the reliable and safe operation of electrical equipment. KPM offers advanced Tan Delta testing instruments that comply with IEC and ASTM standards. These kits provide accurate, real-time results with user-friendly operation and robust design. KPM also offers expert support, calibration, and on-site testing services to help utilities maintain insulation health effectively. 08 What are the Best Practices in Oil Sampling and Analysis? Accurate oil sampling and analysis are vital for assessing the condition of insulating oils used in transformers and other high-voltage equipment. Key best practices include taking samples from the correct location (ideally turbulent flow areas, upstream of filters, and not from drain plugs), at the right time (when the machine is running and under normal load), and with proper techniques (using clean equipment, avoiding contamination, and labeling samples accurately). Best practices include taking samples from live equipment using clean, dry, and airtight glass or metal containers to avoid contamination. Sampling should be done from designated sampling valves, ideally after allowing sufficient oil flow to flush impurities. Samples must be labeled clearly with details like equipment ID, location, date, and temperature. Proper analysis involves tests for moisture content, dielectric strength, acidity, interfacial tension, Tan Delta, and dissolved gas analysis (DGA), offering insights into oil aging, contamination, and equipment health. KPM provides a full range of oil testing instruments, including BDV testers, moisture analyzers (Karl Fischer), and Tan Delta kits, all adhering to IEC/ASTM standards. KPM also offers oil sampling kits, training, and onsite testing services, ensuring reliable diagnostics and extending asset life. 09 How to Interpret Insulation Resistance Test Results? Insulation resistance (IR) testing assesses the quality of insulation in electrical equipment by measuring its resistance to current flow. IR testing helps detect insulation weaknesses before they lead to equipment failure, short circuits, or electrical shocks. The test measures the resistance between conductors (e.g., wires) or between a conductor and ground, indicating how well the insulation is preventing current leakage. Interpreting these results involves understanding the expected values, identifying trends, and recognizing factors that can affect the readings. A high insulation resistance (in the megaohms or higher) generally indicates good insulation, while low readings suggest potential problems like moisture, contamination, or damage.. It is typically conducted using a megohmmeter at voltages like 500V, 1kV, or 5kV. Higher resistance values (in megaohms or gigaohms) indicate good insulation, while lower values suggest moisture ingress, dirt, or insulation deterioration. Acceptable IR values vary by equipment type, but a general rule is 1 MΩ per kV of operating voltage, with time-based readings (1 min, 10 min) used to calculate the polarization index (PI). A PI > 2 indicates good insulation; < 1.5 may signal problems. KPM offers reliable insulation resistance testers with digital displays, automatic PI/ DAR calculation, and high-voltage test capabilities (up to 20kV). Compliant with IEC and IEEE standards, KPM’s instruments ensure precise diagnosis. KPM also provides training and expert support to help customers accurately interpret IR results for preventive maintenance and asset safety. 10 What is Electrical Oil Testing According to ASTM/IEC Standards? Electrical insulating oils play a critical role in cooling and insulating transformers, circuit breakers, and other high-voltage equipment. Electrical oil testing, particularly for transformer oil, is crucial for assessing its performance and detecting potential issues. Various ASTM and IEC standards govern these tests, ensuring consistent and reliable results. These standards cover a range of properties like dielectric breakdown voltage, acidity, moisture content, and more. Key ASTM and IEC Standards for Electrical Oil Testing: 1. Dielectric Breakdown Voltage: IEC 60156: Specifies the method for determining the dielectric breakdown voltage of insulating liquids at power frequency. This test is vital for assessing the oil's ability to withstand electrical stress. ASTM D877: Another standard for determining dielectric breakdown voltage, using disk electrodes. ASTM D1816: Uses VDE electrodes for the same purpose. 2. Moisture Content: IEC 60814: Specifies the method for determining the water content in insulating liquids. 3. Acidity (Neutralization Value): IEC 62021-1: Provides the standard for determining the acidity of insulating liquids. 4. Dissolved Gas Analysis (DGA): While not explicitly mentioned in the provided context, DGA is a crucial test for identifying potential problems like overheating or arcing within a transformer. 5. Other Important Tests: IEC 60422: Covers various aspects of insulating oil, including appearance, color rating, and sludge content. ASTM D1500: Specifies the method for determining the color of petroleum products. Interfacial Tension (ASTM D971): Indicates the presence of soluble contaminants. Resistivity (IEC 60247): Measures the oil's ability to resist electrical current flow. Dissipation Factor (IEC 60247): Indicates the energy loss in the oil due to dielectric losses. Flash Point (ASTM D92, ASTM D93): Determines the temperature at which the oil will ignite. Pour Point (ASTM D97): Indicates the lowest temperature at which the oil will flow. Viscosity (ASTM D445): Measures the oil's resistance to flow. KPM provides a comprehensive range of oil testing instruments aligned with ASTM and IEC standards. These include BDV testers, Tan Delta analyzers, moisture testers. KPM also offers calibration, on-line testing, and training services, ensuring users maintain transformer health and meet regulatory requirements effectively. 11 How to measure oil density and what are its implications? Oil density is the mass per unit volume (typically expressed in kg/m³ or g/cm³) and is a key parameter in evaluating the quality and type of insulating oils used in transformers and electrical equipment. Measuring oil density helps in determining its composition, potential uses, and potential for refining into various products like gasoline, diesel, or asphalt. Changes in oil density can indicate contamination, degradation, or improper formulation, affecting cooling efficiency, dielectric strength, and compatibility with equipment materials. Accurate density measurement is essential during oil processing, quality checks, and routine maintenance. It is often performed at a standard reference temperature (usually 15°C or 20°C) using digital density meters or hydrometers, in line with ASTM D4052 or ISO 12185 standards. KPM offers precise digital density meters and oil analysis kits compliant with international standards. These tools are designed for ease of use, fast operation, and high accuracy. With additional support like calibration services and technical guidance, KPM ensures reliable oil density measurement, aiding customers in maintaining transformer performance and operational safety. 12 What are the Early Warning Signs from Your Oil Particle Counter? An oil particle counter detects and quantifies solid contaminants in insulating oil, providing early warning signs of equipment wear, insulation breakdown, or external contamination. Key indicators include: Rising Particle Counts: A sudden increase in particles, especially >4µm or >6µm, can signal insulation aging, arcing, or mechanical wear. Shift in Particle Size Distribution: A higher concentration of larger particles may indicate internal component failure. Exceeding ISO 4406 Cleanliness Codes: Values outside acceptable limits suggest a decline in oil cleanliness, potentially leading to reduced dielectric strength and accelerated aging. Regular monitoring allows for trend analysis, helping prevent failures before they occur. KPM provides portable and lab-grade oil particle counters aligned with ISO 4406 and NAS 1638 standards. These instruments offer accurate, real-time data for critical decision-making. Combined with expert support and service, KPM enables power utilities and industries to ensure oil cleanliness and extend equipment lifespan. 13 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? Using both TEV and ultrasonic methods together enhances diagnostic accuracy: TEV gives insight into internal discharge severity and location. Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. This dual-method approach is vital for: Preventive maintenance, Avoiding insulation failures, Improving switchgear reliability, and Extending equipment life without needing shutdowns.
- PD Detector (Digital) | KPM India |PD Detector (Digital)
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Digital) |https://kpmtek.wixsite.com/website/es/pd-detector-digital Detector de descargas parciales (digital)
- Intermediate Transformer | KPM India |Intermediate Transformer
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Intermediate Transformer |https://kpmtek.wixsite.com/website/es/intermediate-transformer Transformador intermedio
- PD Calibrator | KPM India |PD Calibrator
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Calibrator |https://kpmtek.wixsite.com/website/es/pdcalibrator Calibrador de DP
- EV Test Equipment Applications | KPM Engineering Sol.
Advanced EV battery testing solutions by KPM for service centers. Ensure precise diagnostics, battery health analysis, and efficient maintenance Centro de servicio de baterías para vehículos eléctricos Soluciones de prueba Prueba y ecualización de celdas Haz clic ahora Mantenimiento de alta potencia Haz clic ahora Pruebas de descarga de alta tensión Haz clic ahora Módulo / Pack Igualdad Haz clic ahora Anchor 1 Pruebas y ecualización de celdas KPM BCD B-4X BCD SERIES KPM BCD B4X integrates discharge, charging and activation functions into one unit with features of multi-channel, independent cell, and large current. View More KPM BCD 0530 BCD SERIES KPM BCD 0530 can quickly and accurately maintain the cells with large voltage drops in the lithium battery module. View More KPM BCD 0550 BCD SERIES KPM BCD 0550 Series is the latest cell discharge-charge device developed by KPM , which adopts advanced battery testing technology and combines the charging and discharging characteristics of lead-acid batteries and lithium-ion batteries. View More Anchor 2 Pruebas y ecualización de celdas KPM LI80L Probador de fugas de aire Probador de fugas de aire para paquetes de baterías Ver más KPM LI80L Probador de fugas de aire Probador de fugas de aire para paquetes de baterías Ver más KPM LI80L Probador de fugas de aire Probador de fugas de aire para paquetes de baterías Ver más KPM LI80L Probador de fugas de aire Probador de fugas de aire para paquetes de baterías Ver más Anchor 3 Medidores y otros KPM CCDB SERIES CCDB SOLUTION CCDB Series Lithium Battery Equalization Tester is developed to solve cell voltage imbalance quickly. View More CM-0524 CCDB SLOUTIONS CM - 05224 can quickly test cells voltage in the lithium battery module and judge the balance of the entire battery pack. View More KPM CCDB + Series CCDB SLOUTIONS Suitable for daily charge, discharge, and equalization maintenance of lithium-ion battery cells, module cells, and pack cells. View More KPM CCDB 5V 15A CCDB SLOUTIONS CCDB 5V 15A Lithium Battery Equalization Tester can quickly perform charge, discharge, and equalization tests on individual cells in lithium battery packs. View More Anchor 4 AIR LEAKAGE SOLUTIONS KPM-24BV Medidor de voltaje de celda de litio AL-80L Battery Leakage Tester is the latest high-accuracy nondestructive testing equipment developed by KPM. KPM-24BV Medidor de voltaje de celda de litio AL-80H is the latest high-accuracy nondestructive testing equipment developed by KPM, with the highest sensitivity and stability in the new energy industry. Preguntas frecuentes (FAQ) FAQ about Battery Testing & EV Systems : 01 How to Test a Li-ion Battery Pack Safely and Efficiently ? Testing a Li-ion battery pack requires a balance of safety, accuracy, and efficiency. Key steps include: Visual Inspection: Check for swelling, leakage, or damaged terminals. Voltage Check: Measure open-circuit voltage to ensure cells are within the safe range. Insulation Resistance Test: Verify electrical isolation between terminals and the battery casing. Capacity & Discharge Testing: Simulate real-world loads to assess actual capacity, energy output, and discharge efficiency. Impedance/IR Testing: Identify aging cells or weak connections. Thermal Monitoring: Monitor temperature rise during charging/discharging to detect potential overheating. Safety tips include using proper PPE, short-circuit protection, and ventilated areas to avoid thermal events. KPM's Battery Pack Tester is designed for safe and efficient testing of EV and industrial Li-ion packs. It offers automated test sequences, multi-channel voltage/current monitoring, and integrated thermal protection. The tester's real-time data logging and analysis software help ensure accurate diagnostics, preventive maintenance, and safer battery operation. 02 What are the Top 5 Mistakes to Avoid While Discharging Lithium-Ion Cells ? Discharging lithium-ion cells must be done with precision to avoid safety risks and performance degradation. Here are the top 5 mistakes to avoid: 1. Over-Discharging Below Safe Voltage Limits: Going below 2.5–3.0V can cause irreversible damage or capacity loss. 2. High Current Discharge Without Monitoring: Excessive current leads to overheating, thermal runaway, or cell swelling. Always follow rated discharge current. 3. Ignoring Cell Balancing: Uneven discharge across cells in a pack can reduce lifespan or cause imbalance-related failures. 4. Lack of Temperature Monitoring: Not monitoring temperature during discharge can hide thermal issues that lead to fires or failure. 5. Discharging Without Load Control or Cut-Off Logic: Manual discharge setups without auto cut-off risk cell damage or safety hazards. KPM’s Battery Tester prevents these issues through programmable discharge profiles, auto cut-off, real-time voltage/current/temperature monitoring, and cell balancing diagnostics. It ensures safe, accurate discharge testing for EVs, storage systems, and R&D applications. 03 Why Cell Balancing is Critical in Battery Pack Design? Cell balancing is essential in lithium-ion battery pack design to ensure uniform voltage levels across all cells, which directly impacts performance, safety, and lifespan. Without balancing, even a single weak or overcharged cell can cause: Reduced usable capacity Premature degradation or failure Overheating or thermal runaway False full/empty readings during charging/discharging There are two types: 1. Passive balancing dissipates extra energy as heat and 2. Active balancing redistributes charge to weaker cells, improving efficiency KPM’s Battery Solution features integrated smart cell balancing technology. It continuously monitors each cell’s voltage and automatically adjusts charge levels to maintain uniformity. Whether in EVs, solar storage, or industrial packs, KPM’s system ensures balanced charging/discharging, enhanced cycle life, and optimal safety. The real-time monitoring interface also provides visual alerts on imbalance conditions—enabling proactive maintenance and higher reliability. 04 How AH Curve Tracers Improve Battery Quality Analysis? Ampere-Hour (AH) Curve Tracers or constant current discharge testers are critical tools for evaluating battery quality. By discharging the battery at a fixed current and recording voltage over time, they generate AH curves that reveal: 1. Actual capacity vs. rated capacity 2. Voltage stability during load 3. Internal resistance and aging behavior 4. Cut-off voltage performance 5. Cell degradation patterns over cycles This data helps manufacturers and maintenance teams identify underperforming cells, confirm batch consistency, and detect early signs of capacity fade—essential for EVs, energy storage, and critical backup systems. KPM’s Constant Current Battery Testing Equipment is designed for precise AH curve analysis. It offers programmable discharge rates, real-time voltage monitoring, and auto cut-off features. With multi-channel support and detailed data logging, it enables accurate grading, performance benchmarking, and lifecycle testing—ensuring battery packs meet safety and performance standards before deployment. 05 What do you mean by Preventing Battery Fires also what are the Role of Air Leakage Testers ? Battery fires often originate from internal short circuits, moisture ingress, or poor sealing during manufacturing. Air leakage testers play a critical role in preventing such incidents by verifying the airtightness of battery cells, modules, and packs. These testers use pressure decay, vacuum decay, or mass flow methods to detect even the smallest leaks. Ensuring proper sealing prevents oxygen or humidity from entering the cell enclosure, which can lead to electrolyte degradation, corrosion, or thermal runaway in lithium-ion batteries. Regular air leakage testing helps: Maintain IP-rated enclosures for harsh environments Detect seal defects before cell assembly Ensure consistency in automated production lines Comply with safety standards like UN38.3 and IEC 62133 KPM offers high-sensitivity air leakage testers tailored for EV and energy storage applications. With fast cycle times, digital pressure control, and data traceability, KPM’s solution enhances quality assurance and plays a vital role in fire prevention and safe battery operation. 06 What is EV Battery Diagnostics ? What are the Tools Every Service Center Must Have? As electric vehicles (EVs) grow rapidly, service centers must be equipped with specialized battery diagnostic tools to ensure safe and effective maintenance. Key tools include: Battery Pack Testers – For measuring voltage, current, capacity, and SOH (State of Health) during charge/discharge cycles. Cell Balancing Analyzers – To detect and correct imbalances between individual cells in the pack. Insulation Resistance Testers – Essential for checking insulation integrity to prevent leakage currents and electrical hazards. Thermal Imaging Devices – For identifying overheating cells or poor thermal management. Communication Interface Tools – To read battery management system (BMS) data via CAN or other protocols. Air Leakage Testers – To ensure sealed packs meet safety standards. KPM provides an integrated suite of EV battery testing equipment, including constant current testers, smart BMS diagnostic tools, cell balancers, and leakage testers. Designed for workshop and field use, KPM’s devices offer fast, accurate, and automated diagnostics, helping service centers improve safety, reduce downtime, and extend battery life. 07 Do you know Charging vs. Discharging Tests: Key Differences Explained, Advantages of each test? Charging and discharging tests are both essential for evaluating battery performance, but they serve different purposes and reveal different insights. Both tests are complementary—charging tests help optimize input energy handling, while discharging tests validate output performance. Together, they provide a comprehensive view of battery health and reliability Key Differences Feature : Charging Test Discharging Test Purpose: Assess charging efficiency & behavior Measure capacity, energy output, Stability Data Collected: Charge time, input current, voltage rise Discharge time, voltage drop, delivered AH Risks : Overcharging, thermal buildup Deep discharge, undervoltage stress Monitoring Focus: Temperature rise, end-of-charge detection Voltage sag, current stability, thermal trend Control : CC/CV (Constant Current/Voltage) Constant Current or Constant Power load Advantages of Charging Test Evaluates charging curve behavior and efficiency Helps in BMS calibration and charger compatibility Detects issues like overvoltage cutoff failure or high IR during charge Monitors thermal response during charging cycles Advantages of Discharging Test Measures real usable capacity of the battery Identifies aging or weak cells through voltage sag Simulates real-world usage conditions Critical for state of health (SOH) estimation and performance grading KPM’s battery testers support both charging and discharging modes with programmable current profiles, real-time monitoring, and data logging, enabling accurate, automated, and safe battery diagnostics across EVs, energy storage, and R&D applications. 08 What is Understanding State of Health (SOH) in Li-ion Batteries? State of Health (SOH) is a key parameter that reflects the overall condition and performance capability of a lithium-ion battery compared to its original, factory-new state. Expressed as a percentage, SOH = 100% means the battery performs at full capacity; lower values indicate degradation. Factors Affecting SOH: Capacity Fade: Reduction in charge-holding ability over cycles. Increased Internal Resistance: Leads to voltage drop and heating. Cycle Life: Number of full charge-discharge cycles completed. Temperature Stress: Accelerates degradation if outside ideal range. Charge/Discharge Rates: High currents can strain cell chemistry. How SoH is Measured: Capacity Test: Compares actual vs. rated capacity (e.g., via constant current discharge). Impedance/Resistance Test: Higher internal resistance suggests aging. Voltage Behavior Analysis: Under load, abnormal voltage drops signal poor SOH. Algorithmic Estimation: Used in BMS for real-time SOH prediction based on usage history. KPM’s battery testing equipment measures SOH using precision discharge testing, impedance analysis, and real-time voltage tracking. Its smart software computes SoH accurately, helping users assess battery viability, schedule replacements, and extend system reliability in EVs and energy storage applications. 09 Do you know Battery Test Protocols According to IEC/UN38.3 Standards ? Battery safety and performance testing follow strict protocols defined by IEC standards (e.g., IEC 62133, IEC 62660) and UN38.3, which governs the safe transport of lithium batteries. These protocols ensure batteries can withstand mechanical, electrical, and environmental stress. Key UN38.3 tests include: Altitude simulation Thermal cycling Vibration and shock resistance External short circuit Overcharge and forced discharge Impact/crush test IEC standards add protocols for electrical performance, insulation resistance, and endurance cycling. Each test is designed to validate battery integrity, prevent fire or explosion risks, and ensure global compliance for transport and use. KPM’s battery testing systems are built to comply with these standards, offering programmable test sequences, automated data logging, and safety cutoffs. This enables manufacturers and labs to efficiently validate battery packs for EVs, consumer electronics, and storage systems before certification and deployment. 10 How to Extend EV Battery Life Through Better Testing? Extending the life of an EV battery begins with smart, proactive testing practices throughout the battery’s lifecycle—from development to daily use. Key strategies include: Accurate SoH & Capacity Testing: Regularly monitor State of Health (SoH) and capacity using controlled charge/discharge cycles to detect early degradation and prevent overuse of weak cells. Cell Balancing Verification: Use testers to identify and correct imbalances, ensuring even load distribution and avoiding stress on individual cells. Thermal Profiling: Monitor temperature behavior under load to detect hotspots or cooling issues that accelerate aging. Internal Resistance Checks: Periodic impedance testing identifies cells with rising resistance—a sign of aging or failure. Simulated Real-World Load Testing: Evaluate performance under actual driving conditions to optimize BMS tuning and charging protocols. KPM’s battery testing solutions support all of the above, offering automated diagnostics, real-time analytics, and precision control. This helps EV manufacturers and service centers maximize battery life, reduce failures, and enhance long-term performance. 11 Do you know the Evolution of Battery Testing Equipment in the EV Era? With the rise of electric vehicles (EVs), battery testing equipment has evolved from basic voltage and capacity checkers to smart, multifunctional diagnostic platforms. Early systems focused on simple charge/discharge cycles, but modern EV batteries demand high-precision testing for complex parameters like State of Health (SoH), internal resistance, cell balancing, and thermal behavior. Today’s equipment supports high-voltage, multi-channel testing, fast data logging, and automated test protocols aligned with IEC and UN38.3 standards. Integration with Battery Management Systems (BMS), cloud connectivity, and AI-driven analytics are now standard, enabling predictive maintenance and lifecycle optimization. KPM’s battery testing solutions reflect this evolution by offering advanced tools for real-time monitoring, constant current testing, leakage detection, and cell balancing verification. Built for R&D, manufacturing, and service centers, KPM's systems ensure safety, accuracy, and performance—essential in the fast-paced EV ecosystem. 12 Why Your Battery Test Bench Might Be Giving False Results? False results from a battery test bench can arise due to calibration errors, inaccurate sensor placement, or improper test conditions. If the voltage or current sensors are not calibrated regularly, readings may drift, leading to incorrect capacity or SoH measurements. Poor contact resistance at terminals or cables can also distort current flow and voltage drop data. Environmental factors like temperature fluctuations or electromagnetic interference can affect sensitive measurements, especially during internal resistance or impedance tests. Additionally, incorrect test profiles—such as setting the wrong cut-off voltage or charge rate—can lead to misleading performance data. Software issues, such as outdated firmware or poor algorithm tuning, may misinterpret real-time data or fail to filter noise properly. KPM’s battery test benches mitigate these issues with auto-calibration, real-time error detection, and intelligent profiling. They ensure accurate, repeatable results that reflect the true performance and safety status of EV and energy storage batteries. 13 What are the Role of Environmental Factors in Battery Pack Testing? Environmental factors play a crucial role in battery pack testing, as they significantly influence battery performance, safety, and lifespan. Temperature, humidity, and altitude conditions can alter a battery’s behavior under both charge and discharge cycles. Temperature affects chemical reactions inside cells. High temperatures accelerate degradation and risk thermal runaway, while low temperatures reduce capacity and increase internal resistance. Humidity can lead to moisture ingress, causing corrosion or insulation breakdown—especially in poorly sealed packs. Altitude (low pressure) impacts thermal dissipation and can increase the risk of electrolyte leakage or expansion in sealed packs. To ensure reliability, batteries are tested in environmental chambers simulating real-world extremes. IEC and UN38.3 standards mandate such conditions for certification. KPM’s battery testing systems integrate seamlessly with environmental chambers, enabling precise control, real-time monitoring, and automated safety checks—ensuring comprehensive evaluation of battery packs under varied environmental stresses. 14 What is Li-ion Cell Grading: How to Do It Right? Li-ion cell grading is the process of evaluating and categorizing cells based on their performance parameters to ensure uniformity in battery pack assembly. Doing it right involves a systematic and precise testing protocol: Key Steps in Proper Cell Grading: Initial Voltage & IR Check: Measure open-circuit voltage and internal resistance to identify defective or aged cells. Capacity Testing (Constant Current Discharge):Discharge cells under a controlled current and record actual capacity (Ah) against rated values. Cycle Performance Evaluation: Charge/discharge cycles help verify stability and consistency across multiple uses. Temperature Monitoring: Track thermal response under load—abnormal heating indicates inefficiency or cell faults. Sorting Criteria: Classify cells based on capacity, IR, voltage behavior, and thermal stability into A, B, C grades. KPM’s cell grading systems offer multi-channel, high-precision testers with automated sorting, real-time data logging, and user-defined grading profiles. This ensures consistent cell performance, longer pack life, and optimal safety for EV and energy storage applications. 15 Difference between Battery Testing for Aerospace and Automotive Applications? Battery testing for aerospace and automotive applications differs significantly due to varying performance, safety, and environmental requirements. Aerospace batteries demand extreme reliability, lightweight design, and operation under harsh conditions like high altitude, vibration, and temperature extremes. Testing includes rigorous altitude simulation, thermal vacuum, and shock/vibration endurance to meet standards like RTCA DO-311 and MIL-STD. In contrast, automotive EV batteries focus on cycle life, thermal management, and high-power performance. Tests involve real-world drive simulation, fast charging analysis, thermal profiling, and compliance with UN38.3, IEC 62660, and ISO 26262. KPM’s testing solutions cater to both sectors with customizable test protocols, environmental chamber integration, and real-time monitoring. For aerospace, KPM offers high-precision, lightweight diagnostics; for automotive, it provides high-throughput, high-current testing systems—ensuring safety, efficiency, and regulatory compliance across industries. 16 End-of-Life Testing for Electric Vehicle Batteries? End-of-life (EOL) testing for electric vehicle (EV) batteries is essential to assess whether a battery can be reused, repurposed, or must be recycled. This testing focuses on determining the State of Health (SoH), remaining capacity, internal resistance, and thermal behavior after prolonged use. Key EOL testing steps include: Capacity Test: Measures actual ampere-hours (Ah) to determine if it meets minimum reuse thresholds (typically ≥70% of original). Impedance Measurement: Identifies internal degradation and cell imbalance. Charge/Discharge Cycle Analysis: Evaluates efficiency and detects abnormal voltage drops or thermal spikes. Thermal Performance Check: Assesses safety risks under load. Leakage and Insulation Tests: Ensures physical and electrical integrity. KPM’s battery EOL testing systems automate these processes with real-time monitoring, trend analysis, and safe discharge protocols. This enables accurate decision-making for second-life applications, such as stationary storage, or safe recycling, aligning with circular economy goals. 17 What do you mean by Understanding the Thermal Runaway Effect? End-of-life (EOL) testing for EV batteries is crucial to determine whether a battery should be reused, repurposed, or recycled. This involves evaluating the battery’s State of Health (SoH), residual capacity, internal resistance, and thermal behavior. Typically, a battery is considered at end-of-life when its usable capacity drops below 70–80% of its original rating. EOL testing includes controlled charge/discharge cycles, impedance analysis, and thermal profiling under simulated real-world loads. It also verifies the integrity of the Battery Management System (BMS) and checks for cell imbalance, swelling, or leakage. This testing helps classify batteries for secondary applications like energy storage or ensures safe recycling of critical materials. KPM’s battery testing systems provide automated, accurate EOL assessment with programmable protocols, multi-parameter monitoring, and safety interlocks, enabling OEMs and recyclers to make informed decisions about battery reuse, life extension, or disposal. 18 Difference between Battery Energy Density and Safety: A Testing Perspective? As energy density increases in lithium-ion batteries to meet the demands of EVs, aerospace, and portable electronics, safety risks also rise. Higher energy density means more power is stored in the same space, which can lead to thermal runaway, fire, or explosions if not properly managed. From a testing perspective, it is critical to balance performance with safety through: Thermal abuse tests to simulate overheating Overcharge/overdischarge tests to detect BMS failure scenarios Short-circuit and impact testing to assess mechanical protection Internal resistance and SoH testing to identify degradation risks early Leakage and enclosure integrity tests to prevent moisture or gas ingress Testing protocols per UN38.3, IEC 62133, and UL 2580 ensure that high-energy cells meet strict safety thresholds. KPM’s battery testing solutions are designed to test both high-capacity and high-safety requirements, providing real-time monitoring, automated safety shutdowns, and environmental stress simulations to ensure safe, high-density battery deployment. 19 What Makes a Good Battery Service Center? A good battery service center combines technical expertise, advanced diagnostic tools, and safety-first practices to ensure efficient and reliable battery maintenance. Key qualities include: Skilled Technicians trained in EV, industrial, and energy storage battery systems. Advanced Testing Equipment for SoH analysis, cell balancing, IR testing, and BMS diagnostics. Safety Protocols including insulation resistance checks, thermal monitoring, and ESD protection. Data-Driven Diagnostics using software tools for real-time monitoring and historical performance tracking. Proper Infrastructure, such as ventilated workspaces, fire suppression systems, and isolation zones for damaged packs. Support for Multiple Battery Chemistries and pack configurations.
- Cable Testing Equipment by KPM | Fault Location & Diagnostics|CABLE
Advanced cable testing equipment by KPM for precise fault location, insulation testing, and condition monitoring of power cables. MONITOREO EN LÍNEA DE PD Y TIERRA KPM TAN DELTA 40 KPM TD 40 KPM TD 40 capacitance and tan delta tester is designed for condition assessment of high capacitance & high voltage electrical insulation in high voltage apparatus. It is a measurement instrument that is used with an AC power source and a standard capacitor to form a complete measurement setup. KPM TD 40 is a two-piece design. the control module and the test module communicate wirelessly during the test. KPM DC HIPOT KPM DC HIPOT KPM Portable DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM- DC series of HIPOTs is light weight, portable & easy to use. These units are user friendly & its output is stable at even high voltages DC vs AC High-potential Testing Direct current high-potential testing provides several advantages over alternating current. KPM VLF Series KPM VLF Series KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. KPM AC HIPOT KPM AC HIPTO KPM Portable AC/DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM-AC/DC series of HIPOTs is light weight , portable & easy to use. These units are user friendly& its output is stable at even high voltages it is the basic test equipment used by the power station, transmission and distribution companies for testing the insulation strength of all kind of electrical products, electrical equipment and insulated materials. KPM VLF Hipot Tester KPM VLF Hipot Tester KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. Preguntas frecuentes (FAQ) FAQ about Cable testing : 01 1. What is VLF testing, and why is it used for cable diagnostics? VLF (Very Low Frequency) testing applies a low-frequency AC voltage—typically 0.01 Hz to 0.1 Hz—to power cables to assess their insulation condition. It’s used because VLF testing can apply a high voltage stress similar to normal operating conditions but with less heating and damage risk than standard power frequency tests. This makes it ideal for diagnosing medium- and high-voltage cables, especially in field conditions, to detect weaknesses like insulation degradation, voids, or defects before failure occurs. 02 2. How does VLF testing differ from conventional AC hipot testing? VLF testing uses a very low frequency (typically 0.01 to 0.1 Hz) AC voltage, whereas conventional AC hipot testing applies standard power frequency (50/60 Hz) voltage. The low frequency in VLF reduces the capacitive charging current in long cables, allowing high test voltages without overheating the cable insulation. This makes VLF safer and more practical for field testing of long medium- and high-voltage cables. In contrast, conventional AC hipot tests can cause excessive heating and damage when used on such cables. 03 3. What types of cable defects can VLF testing detect? VLF testing is effective at identifying a wide range of insulation defects and weaknesses within medium- and high-voltage power cables. It can detect partial discharge (PD) activity, which is a common early indicator of insulation deterioration such as microscopic voids or cracks within the cable’s insulation material. These PD sites generate localized electrical discharges that degrade the insulation over time, potentially leading to catastrophic failure if not addressed. Additionally, VLF testing can reveal water ingress problems, where moisture penetrates the insulation and lowers its dielectric strength, as well as contamination or aging effects such as thermal, mechanical, or chemical degradation of the insulation material. It can also uncover manufacturing defects like thin spots, improper curing, or insulation gaps. While VLF testing is excellent for assessing the overall integrity of the cable insulation and detecting areas of weakness, it may not precisely locate the defects. For detailed localization, it is often combined with other techniques such as partial discharge (PD) measurements or time-domain reflectometry (TDR). 04 4. What is Tan Delta (VLD) testing, and how does it assess cable insulation quality? Tan Delta (also called Very Low Dissipation factor or VLD) testing measures the dielectric losses in cable insulation by applying an AC voltage and analyzing the phase difference between the current and voltage. The "tan delta" represents the ratio of resistive (lossy) current to capacitive (ideal) current. A low tan delta value indicates good insulation with minimal energy loss, while higher values suggest deterioration due to moisture, contamination, or aging. By measuring these losses, Tan Delta testing assesses the overall insulation condition and detects early-stage degradation before catastrophic failure. It is highly sensitive to insulation quality changes and is commonly used for condition assessment and preventive maintenance of medium- and high-voltage cables. 05 5. How do Tan Delta results indicate the health or degradation of a cable? Tan Delta results reflect the insulation’s dielectric losses, which increase as the cable ages or deteriorates. A low tan delta value means the insulation is healthy, with minimal leakage current and good dielectric integrity. Conversely, a rising tan delta value indicates increasing insulation defects such as moisture ingress, contamination, cracks, or thermal aging. Trends in tan delta over time are especially important: a gradual increase suggests progressive degradation, allowing maintenance teams to plan repairs before failure occurs. Sudden spikes may point to acute damage or contamination. Thus, monitoring tan delta values helps assess the insulation’s condition, predict remaining service life, and prioritize maintenance actions. 06 6. What is VLF Partial Discharge (PD) testing, and how does it help's identify insulation defects? VLF Partial Discharge (PD) testing uses very low frequency voltage to stress the cable insulation while detecting and measuring partial discharges—tiny electrical sparks that occur within insulation voids or defects. These discharges are often early signs of insulation failure, caused by imperfections like cracks, voids, or contamination. By capturing PD activity, VLF PD testing helps pinpoint insulation defects before they lead to catastrophic cable failure. It provides valuable insight into the type, location, and severity of defects, enabling targeted maintenance and reducing unplanned outages. This makes it a crucial tool for proactive cable condition assessment. 07 7. Can VLF PD testing detect early-stage insulation failures? Yes, VLF Partial Discharge (PD) testing is specifically designed to detect early-stage insulation failures. Partial discharges are small electrical sparks that occur in microscopic voids, cracks, or impurities within the cable insulation—often long before a complete breakdown happens. By applying very low frequency voltage, VLF PD testing stresses the insulation gently but effectively, allowing detection of these early PD activities. Detecting partial discharges early helps identify weak spots or developing defects in the insulation, enabling maintenance teams to address issues proactively, extend cable life, and avoid costly unplanned failures. 08 8. What are the typical test voltages and frequencies used in VLF cable testing for 11 kV and 33 kV cables? For 11 kV cables, the VLF test voltage typically ranges from 15 kV to 33 kV, depending on the test type—diagnostic tests usually use about 1.5 times the rated voltage (around 16.5 kV), while withstand tests may apply up to 2.5 to 3 times the rated voltage (up to ~33 kV). For 33 kV cables, the test voltage typically ranges from 45 kV to 75 kV, with diagnostic tests at around 1.5 times the rated voltage (approximately 49.5 kV), and withstand tests potentially up to 2.5 times rated voltage (about 82.5 kV), though the upper limit depends on cable specifications and standards. In both cases, the frequency used is very low—typically 0.1 Hz—to reduce capacitive currents and minimize heating during testing, making it safe and effective for long cable lengths. 09 9. How do environmental factors affect VLF, Tan Delta, and PD test results? Environmental conditions like temperature, humidity, and soil moisture can significantly impact VLF, Tan Delta, and Partial Discharge (PD) test results. Temperature: Higher temperatures generally reduce insulation resistance and can increase Tan Delta values and PD activity due to increased molecular activity in the insulation. Low temperatures can raise resistance but might mask some defects. Humidity and Moisture: Moisture ingress lowers insulation resistance and increases dielectric losses, causing higher Tan Delta readings and more PD activity. Wet conditions can lead to more apparent insulation degradation during testing. Soil Conditions: For underground cables, soil resistivity and moisture affect grounding and test current paths, influencing VLF and PD measurements. Dry or rocky soils may lead to higher resistance readings. Surface Contamination: Dirt, oil, or salts on cable surfaces can cause surface discharges, impacting PD and Tan Delta results. Because of these factors, it’s important to consider and document environmental conditions during testing and, where possible, perform tests under similar conditions for consistent trending and accurate diagnostics. 10 10. What are the safety precautions and best practices during VLF and PD cable testing? Ensure Proper Training: Only qualified personnel familiar with high-voltage testing and equipment should conduct tests. Use Appropriate PPE: Wear insulated gloves, safety glasses, and flame-resistant clothing. Clear the Test Area: Establish a safe perimeter with warning signs and barriers to prevent unauthorized access during testing. Verify Equipment Condition: Check all test instruments, leads, and connections for damage before use. De-energize and Ground Cables: Ensure the cable is disconnected from the power system and properly grounded before connecting test equipment. Follow Manufacturer Guidelines: Use the recommended test voltages, durations, and procedures specific to the cable type and equipment. Monitor Test Parameters: Continuously observe voltage, current, and PD activity during the test to detect abnormalities early. Avoid Testing in Hazardous Environments: Do not perform tests during storms, wet conditions, or explosive atmospheres. Record Test Data Accurately: Document all parameters, environmental conditions, and observations for traceability and analysis. Emergency Preparedness: Have clear procedures for immediate shutdown and emergency response in case of equipment failure or personnel hazard. Following these precautions ensures safety and reliable test results while protecting both personnel and equipment.
- Battery Testing Applications .| Technical Form
Kindly fill this form as per your technical requirements , We have complete range of Battery Testing Solutions for Utility , EV Industry & Portable Li Ion batteries Applications . Li Ion Battery - Charging ,Discharging and Equalisation Lead Acid Battery - Discharging Solutions Battery Monitoring Solutions Used German Machines – Proven Reliability, Delivered by KPM At KPM, we bring these machines directly to international buyers with a unique advantage: We have a permanent electrical consultant stationed in Germany, enabling us to source the best used machines from trusted sellers across Germany and the EU. Our approach ensures: Direct procurement from authentic sources Initial inspection as per international industry standards Live video inspection for transparency and buyer confidence Final inspection at the seller’s site before dispatch to India Maximum reliability and value in every machine delivered Whether you're in metalworking, plastics, power sector testing, or process automation, our team ensures that you receive tried, tested, and trusted machinery—not just equipment, but a solution. Get in touch with KPM to know what’s available in the European market right now. Why buy new when you can buy proven? A used machine, if purchased judiciously, is not just a cost-effective choice—it’s a proven performer. Across industries, German-made machines are globally recognized for their rugged construction, precision engineering, and long-term reliability. Request form KPM Assurance Framework Preguntas frecuentes 01 Metalworking & Fabrication Machinery :- Top German/European Brands: DMG MORI (Germany/Japan) – CNC turning/milling centers . TRUMPF (Germany) – Laser cutting, bending machines . EMAG, INDEX, GILDEMEISTER – Lathes, turn-mill centers . Bystronic (Switzerland) – Sheet metal and laser cutting. Amada (Europe) – Press brakes, punching systems 02 Plastic & Rubber Processing Machines :- Top Brands: ARBURG (Germany) – Injection moulding. ENGEL (Austria) – Injection moulding. KRAUSSMAFFEI (Germany) – Plastic & rubber machines DEMAG Plastics Group – Injection moulding. BOY (Germany) – Compact moulding machines. 03 Printing & Packaging Machinery :- Top Brands: HEIDELBERG (Germany) – Offset printing KBA (Koenig & Bauer) – Sheetfed & web printing BOBST (Switzerland) – Die cutting, folder-gluers Windmöller & Hölscher (W&H) – Flexographic printing MAN Roland – Newspaper and offset printing 04 Pharmaceutical, Chemical & Process Equipment :- Top Brands: Glatt (Germany) – Fluid bed systems, granulators GEA (Germany) – Process engineering, mixers FETTE (Germany) – Tablet presses IMA (Italy) – Packaging & pharma lines Hosokawa Alpine (Germany) – Powder & particle processing 05 Woodworking Machines :- Top Brands: HOMAG Group (Germany) – CNC routers, edgebanders BIESSE (Italy) – CNC machining centers SCM Group (Italy) – Panel saws, joinery machines Altendorf (Germany) – Panel saws 06 Construction & Heavy Machinery :- Top Brands: LIEBHERR (Germany) – Cranes, earthmovers WIRTGEN Group (Germany) – Road construction machines BOMAG (Germany) – Rollers, pavers MAN (Germany) – Trucks, concrete mixers 07 Food & Beverage Machinery:- Top Brands: Krones AG (Germany) – Bottling, filling lines GEA (Germany) – Dairy, juice, beer lines ALFA LAVAL (Sweden) – Heat exchangers, separators Tetra Pak (Sweden) – Packaging and UHT Multivac (Germany) – Vacuum packaging 08 Industrial Automation & Robotics:- Top Brands: KUKA (Germany) – Industrial robots ABB Robotics (Switzerland) – Welding, pick & place FANUC Europe (Japan with EU operations) – CNC/robotics STÄUBLI (Switzerland) – High-speed robotics YASKAWA Europe – Motion control and robotics 09 Generators, Power & Electrical Plants:- Top Brands: Siemens Energy (Germany) – Turbines, generators MAN Energy Solutions – Large engines and gensets MTU (Rolls-Royce Power Systems) – Diesel generators AEG Power Solutions (Germany) – Power electronics HITZINGER (Austria) – Rotary UPS, alternators 10 Key Categories of Used Printing Machines: 1. Offset Printing Machines Used for high-volume, high-quality printing (books, magazines, brochures, packaging).Sheet-fed Offset. Brands: Heidelberg (e.g., SM 74, CD 102 series) KBA (Koenig & Bauer) MAN Roland Features: 2 to 8 color units, high-speed (up to 18,000 sheets/hr) Use: Commercial printing, packaging, brochures Web-fed Offset Used for newspapers and long-run publications Brands: Goss, Manroland Web Systems. 2. Flexographic Printing Machines: Used for packaging materials: labels, bags, pouches, corrugated cartons. Brands: Windmöller & Hölscher (W&H) Bobst Comexi (Spain) Printing Substrates: Plastic film, paper, foil, etc. Feature: Roll-to-roll printing, quick-drying inks 3. Gravure Printing Machines: Used for high-quality, long-run packaging printing (magazines, foils). Brands: Rotomec (Italy) Cerutti (Italy) KBA (Germany) 4. Label Printing Machines Ideal for self-adhesive labels, shrink sleeves, and narrow web printing. Brands: Gallus (Switzerland) Mark Andy Nilpeter OMET (Italy) Technologies: Flexo, UV flexo, digital hybrid 5. Digital Printing Machines: For short-run, fast-turnaround jobs (variable data, photos, small runs). Brand: HP Indigo Digital Printing Machines Konica Minolta Xerox Canon Applications: Book-on-demand, labels, business cards 6. Screen Printing Machines Used for textiles, labels, circuit boards, and special surfaces. Brands: Sakurai ATMA Thierry (Germany) 7. Other Auxiliary Machines Cutting Machines: Polar (Germany), Wohlenberg Cutting Machines: Polar (Germany), Wohlenberg Die-Cutting / Folder-Gluers: Bobst, Heidelberg UV Coaters, Embossers








