- Demo Registration | KPM India |Demo Registration
Register today for demonstrations of KPM Electrical Testing Equipment. Formulario de consulta de servicio
- PD Detector (Analog) | KPM India |PD Detector (Analog)
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Analog) |https://kpmtek.wixsite.com/website/es/pd-detector-analog Detector de DP (analógico)
- PD Detector (Digital) | KPM India |PD Detector (Digital)
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Digital) |https://kpmtek.wixsite.com/website/es/pd-detector-digital Detector de descargas parciales (digital)
- Battery Testing Utility by KPM |Accurate Battery Diagnostics|Battery Testing ( Utility )
Advanced battery testing utility by KPM for precise battery diagnostics, performance testing, and maintenance across industrial and commercial systems. PRUEBA DE BATERÍA ( UTILIDAD ) Probador de resistencia y conductancia de batería Catálogo Analizador de batería KPM BA-02 El BA-02 Battery Anlayzer es un probador avanzado que es un dispositivo de administración de batería muy efectivo y económico para probar la resistencia interna de la batería, la conductancia y el voltaje. Le ayuda a eliminar las baterías débiles para garantizar el rendimiento de sus sistemas de baterías. Es capaz de realizar mediciones precisas y consistentes de la resistencia interna (o conductancia) de la batería, baterías de plomo-ácido reguladas por válvula (VRLA), baterías de plomo-ácido ventiladas (VLA) y baterías de Ni-cd, que son la composición principal de los sistemas de energía críticos en espera. Este comprobador de baterías se aplica ampliamente a proveedores de servicios, equipos de operaciones y mantenimiento para la gestión y medición de baterías a fin de garantizar la integridad de la energía en diversas industrias. Registrador de datos de batería Catálogo KPM BDL (Registrador de datos de batería) La serie KPM BDL es un registrador de datos de batería actualizado para cumplir con los estándares de medición IEEE para voltaje de batería, voltaje de cadena, corriente y temperatura ambiente. Se personaliza de 12 V a 700 V para diferentes sistemas de baterías. Y tiene fácil expansión para todos los sistemas de batería. Con la comunicación wifi, puede ver fácilmente los datos completos y generar un informe de prueba en el software de la PC. Para una prueba rápida de la conductancia/resistencia interna de la batería, consulte también Analizador de estado de batería KPM BA 01 . Banco de carga de batería Catálogo Banco de carga de batería KPM Ofrecemos una serie de bancos de carga de batería personalizados con muchos modelos diferentes para la prueba de descarga de corriente constante y la prueba de capacidad de la batería. Cubren un amplio rango de tensión desde 12V hasta 480V de tensión nominal con corriente de hasta 600A. Se aplican ampliamente en diversas industrias. Con su Estuche de Adquisición de Datos (DAC) de batería opcional, los valores de descarga de CADA celda pueden monitorearse en el banco de carga de batería y el software de PC simultáneamente usando el software de visualización de datos de Kongter. El mismo banco de carga de batería DAC en también puede funcionar de forma independiente con "String DAC" para hacer otro producto, Registrador de datos de batería . Para una prueba rápida del estado de la batería, consulte Analizador de estado de batería BA-01 que prueba la conductancia/resistencia interna de la batería en segundos. Preguntas frecuentes FAQ about all our battery utility : 01 What is the purpose of battery utility testing in backup power systems? Battery utility testing ensures the reliability, health, and performance of backup power systems used in utilities, substations, data centers, and critical infrastructure. Over time, batteries degrade due to factors like temperature, charge-discharge cycles, and age. Testing helps detect early signs of failure such as increased internal resistance, reduced capacity, or imbalance among cells. This enables timely maintenance or replacement, preventing unexpected power loss during outages. Utility testing validates whether batteries meet required discharge durations and ensures compliance with standards like IEEE 450 or IEC 60896. Regular testing minimizes downtime, enhances operational safety, and protects expensive downstream equipment. KPM provides advanced battery analyzers and constant current discharge kits designed for utility-scale battery banks. These instruments measure internal resistance, voltage, and capacity under load conditions. KPM’s systems are aligned with international testing standards and are used by utilities to perform periodic health checks, identify weak cells, and ensure uninterrupted power backup readiness. 02 What safety precautions must be taken during battery testing? Battery testing involves handling high voltages, currents, and hazardous chemicals, so strict safety precautions are essential. Always wear appropriate personal protective equipment (PPE) such as insulated gloves, eye protection, and flame-resistant clothing. Ensure proper ventilation, especially for lead-acid batteries that emit hydrogen gas during charging or discharging. Isolate the battery bank from the load before testing, and use insulated tools to prevent short circuits. Verify polarity before connecting test equipment to avoid damage or sparking. Never allow metal objects near open battery terminals. Maintain safe distances and use warning signs during high-current discharge tests. Monitor temperature rise and terminate testing if overheating or voltage instability is observed. Follow the manufacturer’s guidelines and applicable standards (IEEE, IEC) during every procedure. KPM’s battery analyzers and discharge testers are equipped with multiple safety features such as overcurrent protection, reverse polarity alarms, thermal cutoffs, and auto-shutdown. KPM also provides user training and safety documentation to ensure proper and secure operation. 03 How does internal resistance measurement indicate battery health? Internal resistance (IR) is the opposition a battery offers to current flow within its own structure. As batteries age or degrade, their internal resistance increases due to chemical wear, sulfation (in lead-acid), or electrode deterioration. Here's how it reflects battery health: Low IR = Healthy battery: Indicates good electrolyte condition, intact electrodes, and low energy loss during discharge. High IR = Degraded battery: Results in voltage drops under load, reduced capacity, and heat generation during operation. Rising IR over time signals aging or developing faults, even if voltage appears normal. Sudden spikes in IR may indicate failing cells or poor interconnections. Thus, internal resistance is a quick, non-invasive diagnostic metric used to identify weak or failing batteries before they cause critical power failures. KPM’s battery analyzers measure IR accurately across large battery banks, providing real-time indicators of cell health and enabling predictive maintenance. 04 What are the key parameters measured by a battery analyzer? A battery analyzer is used to assess the condition and performance of individual cells and complete battery banks. The key parameters it typically measures include: Internal Resistance (IR):Indicates the battery’s ability to deliver current. Higher resistance means deterioration or aging. Voltage (V): Measures the open-circuit voltage of each cell or unit to check state-of-charge and overall health. Conductance (optional): Used as an alternative to resistance in some analyzers to determine battery condition. Temperature (°C): Affects performance and safety. Monitoring ensures accurate readings and helps prevent overheating. State of Health (SoH): Some analyzers estimate the health of the battery based on historical and real-time data. Cell Imbalance: Detects inconsistencies among cells in a battery bank, which can lead to system failure. Ripple Voltage (if applicable): Monitors AC noise on DC lines, often in UPS and telecom systems. KPM’s battery analyzers measure all key parameters—internal resistance, voltage, temperature, and cell imbalance—with high accuracy. Features include: High-precision sensors and rugged design for utility environments, Built-in safety features (reverse polarity, overvoltage alerts), PC software for data logging, trending, and report generation. Widely used in substations, power plants, and telecom towers for preventive maintenance and health diagnostics. 05 Can battery conductivity testing detect early-stage cell degradation ? Conductivity is a measure of a battery’s ability to pass electrical current. In healthy batteries, conductivity is high because the internal chemical pathways are clean and efficient. As a cell begins to degrade (due to sulfation, corrosion, electrolyte breakdown, or plate shedding), these pathways become obstructed, causing conductivity to decrease—even before voltage or capacity noticeably drops. Early Detection: Changes in conductivity often occur before performance failures, allowing for early intervention. Identifies Weak Cells: It helps isolate underperforming cells within a battery bank. Prevents Failures: Enables predictive maintenance and avoids costly downtime. Monitors Aging: Tracks gradual degradation over time for lifecycle management. KPM’s advanced battery analyzers can perform conductivity or internal resistance-based diagnostics, depending on battery type. These tools help utility and industrial users identify subtle degradation trends early, plan timely maintenance, and ensure long-term battery reliability. 06 Why is constant current discharge testing crucial in critical power applications? Constant current discharge testing is essential because it directly evaluates a battery’s actual capacity and performance under load, simulating real-world power demands. In critical power applications—such as substations, hospitals, data centers, and telecom systems—batteries must supply reliable power during outages or switching events. If a battery cannot sustain the required current for the expected duration, it risks system failure, data loss, or equipment damage. Key reasons it’s crucial: Confirms True Capacity: Validates if the battery can deliver its rated ampere-hours (Ah) under specified load. Identifies Weak Batteries: Detects hidden degradation not revealed by voltage or internal resistance alone. Reveals Runtime Performance: Simulates backup duration under real conditions. Supports Preventive Maintenance: Enables data-driven decisions for battery replacement and servicing. KPM’s constant current discharge kits are designed for high-reliability environments. They offer programmable loads, auto cut-off, data logging, and safety features, ensuring accurate, safe, and standards-compliant capacity testing for critical backup systems. 07 How is the battery's capacity (Ah) validated through a discharge test? Battery capacity, measured in ampere-hours (Ah), is validated by discharging the battery at a constant current until it reaches its specified cut-off voltage. The total time it takes to reach that voltage determines the actual capacity using the formula: Capacity (Ah)=Discharge Current (A) × Discharge Time (hours) Example: If a battery is discharged at 10 A and it takes 5 hours to reach the end voltage, the delivered capacity is: 10 A × 5 hrs = 50 Ah This result is then compared to the battery’s rated capacity (e.g., 100 Ah). If it delivers significantly less, it indicates degradation or failure. KPM’s constant current discharge kits precisely control and monitor the discharge current and voltage. They record time-stamped data, auto-calculate Ah, and generate test reports. These tools comply with standards like IEEE 450, ensuring reliable capacity validation for utility and industrial batteries. 08 What role does ambient temperature play in discharge test accuracy? Ambient temperature has a significant impact on the accuracy and outcome of battery discharge tests. Battery performance is highly temperature-sensitive, particularly for lead-acid, lithium-ion, and Ni-Cd chemistries. At High Temperatures: Battery capacity appears higher because chemical reactions speed up. Can lead to overestimation of real-world performance. Increases the risk of thermal runaway or cell damage. At Low Temperatures: Capacity drops due to slower electrochemical activity. May result in underestimated performance and early cut-off in tests. Internal resistance rises, leading to voltage drops under load. Deviations from this temperature should be noted and corrected using manufacturer-specified compensation factors or software. KPM’s battery discharge testers and analyzers include temperature monitoring sensors. The system records ambient and cell temperatures during testing and can apply correction factors to ensure accurate capacity evaluation under varying environmental conditions. 09 How do we determine end-voltage for discharge cut-off? The end-voltage, or cut-off voltage, is the minimum voltage at which a battery should be discharged to avoid deep discharge damage and to ensure reliable capacity measurement. It is determined based on the battery type, rated capacity, discharge rate (C-rate), and manufacturer specifications. For example, a 12V lead-acid battery typically has an end-voltage of 10.5V (1.75V per cell) at standard rates. Discharging below this threshold can lead to irreversible sulfation, reduced life, or failure. In lithium-ion batteries, cut-off is often set higher (e.g., 2.5V–3.0V per cell) to protect cell chemistry and safety. The correct end-voltage ensures consistent and safe testing across different test cycles. It must also be adjusted for ambient temperature and load current, as higher loads can cause greater voltage sag. KPM’s discharge kits allow users to program end-voltage settings per battery specs. The system automatically halts testing at the preset voltage to prevent over-discharge and protect battery health. 10 How can test data be used to predict battery end-of-life? Battery test data—such as internal resistance, voltage, capacity, and temperature trends—can be analyzed over time to accurately predict end-of-life (EOL). A consistent increase in internal resistance and decline in capacity (Ah) are key indicators of aging. When a battery can no longer deliver at least 80% of its rated capacity, it is generally considered at the end of its useful life. Regular discharge tests and impedance measurements create a performance history that reveals degradation rates, enabling predictive analytics. By identifying abnormal changes, such as faster resistance rise in one cell compared to others, maintenance teams can isolate failing units early. Trend-based monitoring allows scheduling replacements before failures occur, ensuring reliability in critical applications. KPM’s analyzers and discharge kits offer data logging, graphing, and reporting features that help utilities and industries track battery health over time, enabling data-driven EOL prediction and proactive asset management.
- Software Solutions MIIT | KPM India |Software Solutions
We are a team of professionals with a collective experience of 120+ years experience with domain experience in industry sectors that include, Telecom, Media and Entertainment, BFSI, Automotive, Healthcare and Manufacturing. In terms of the industry horizontal, we have experience in: ●Embedded systems – Hardware, Firmware, Bootloaders, BSP, etc. ●Software development – Client-Server internet apps for mobiles as well as desktops. MIIT Initiative MIIT ( Make In India Technology ) - The Full Story We are a team of professionals with a collective experience of 120+ years experience. Each one of us has an extensive domain experience in industry sectors that include, Telecom, Media and Entertainment, BFSI, Automotive, Healthcare and Manufacturing. In terms of the industry horizontal, we have experience in: Embedded systems – Hardware, Firmware, Bootloaders, BSP, etc. Operating Systems and related tools – Compilers, IDE, Debuggers, Frameworks and libraries, Device Drivers, etc. Networking – Protocol stacks, LAN/WAN, Internet, both wireless and wireline. Wireless – 4G/5G networking. Software development – Client-Server internet apps for mobiles as well as desktops. Power Sector Applications of Electrical Testing & Measuring Equipment . Our Services Software Engineering ●Systems software ●Internet applications software ●GUI – Desktop and Mobile ●Software testing services – Manual and Automated. Electronics Engineering ●Consulting services ●Product engineering and dev. ●Hardware design and engineering ●Embedded systems solution engineering Technical Staffing We are fully equipped to expand and mobilize our specialized team at short notice to meet your tight deadlines efficiently. Team Dedication. Expertise. Passion. We are a grounded team, close enough to deeply understand your requirements and large enough to deliver with precision. We are fully equipped to expand and mobilise our specialised team at short notice to meet your tight deadlines efficiently. Portfolio CoFounder & Chairman Dr. Harish Chouhan Ph.D - Signal Processing and Comm. Sys. ( 1984 - 1989 ) Indian Institute Of Sciences, Bangalore Dr. Harish Chouhan is a high-tech visionary and an early pioneer in multiple cutting-edge industries. With a Ph.D. in Signal Processing and Communication Systems from the prestigious Indian Institute of Science (IISc, 1984–1989), he has made significant contributions to advancing technology across various sectors. With 43 years of expertise in hardware and software engineering, he has incubated and grown major businesses for Tatas ($20M+) and Tech Mahindra ($460M), leading teams of 500 to 3,500 people. Dr. Chouhan has worked globally, consulting for multinational companies like Lufthansa, Motorola, Cisco, Nokia, Ericsson, Verizon, AT&T Wireless, and more. His work has extended to diverse sectors, including telecom, defense, and finance, working with entities such as the Defense Ministries of India and Turkey and the Finance Ministry of Sri Lanka. He has also published extensively in national and international journals and participated in numerous ICT and telecom conferences. A few key roles handled by Dr. Harish Chouhan were : Co-Founder, CoHan Consulting Vice President, Tech Mahindra Head of Object Technology Group, TATA Infotech Ltd (now TCS Limited) Head of Applied Technology Group, TATA Infotech Ltd (now TCS Limited) Consultant, Cranes Software Cofounder & Tech Head Krishna Bala B.SC., BANGALORE UNIVERSITY • BANGALORE, KARNATAKA ( 1983 - 1986) Seasoned RF Engineer and Project Manager with over 35+ years of diverse experience in the fields of Embedded systems, Wi-Fi, Telematics, and Cellular system design, Manufacturing, and Deployment. He is highly motivated professional with a proven track record of achievement and understanding of RF systems including but not limited to project management, aligning with customer program management & related teams of the product. Conversant with risk assessment & conformance testing of RF products to harmonized standards, liaising with certification labs for regulatory certifications and progress reporting to senior management. Experience in communicating complex technical topics to a wide variety of audience across the globe. Skills & Expertise: Extensive experience in end-to-end hardware design, validation, and manufacturing of Telematics control units, V2x platforms, and automotive connectivity systems. Expertise in regulatory compliance testing, risk assessment, and technical support for large-scale intelligent transport and telematics projects across multiple geographies. A few key responsibilities handled by Krishna Bala were: Country manager | LEAR INDIA ENGINEERING LLP - PUNE Deputy General Manager| LEAR AUTOMOTIVE INDIA PVT. LTD., (ARADA SYSTEMS INC., was acquired by LEAR CORPORATION in Nov 2015) - Bangalore, Karnataka Principal Hardware Architect & Engineering Head | INNOAIR TECHNOLOGIES (subsidiary of ARADA SYSTEMS INC., USA) - New Taipei City , Zhonghe Dist. - Taiwan Principal Hardware Architect | ARADA SYSTEMS PVT LTD., (subsidiary of ARADA SYSTEMS INC., USA) - Bangalore, Karnataka Independent Hardware Design Consultant | DAQPRO- Bangalore, Karnataka Cofounder & Business Head Raghavendra Saraf MDBA, Marketing 2003 - 2006, Symbiosis Gulbarga University, BE E & CE, 1993 - 1997 Raghavendra is an entrepreneur and business leader with strong start-up, wireless /Telecommunications, Power and Automotive domain experience. Have a strong engineering and Management background and have successfully been part of and founded startups in various disruptive industries from early basic telephony / cellular deployments(2G to 5G) to Bluetooth, Wi-Fi and Connected Vehicles (DSRC-CV2X))/VANET. More than 2 decades of experience in sales ,Marketing/Business Development, project management & Delivery, worked with Fortune 500 companies like Lear Corporation, TechM etc. he worked with leading OEM’s & IT solution providers with Senior leadership positions with Lear Corporation, Michigan, Arada Systems Inc, California, Benning, Germany (Jt. Venture with BSMC,India),Tech M etc..Stellapps Technologies (Digital IoT for Dairy firm) & start-up companies –Eagle AI Consulting/ Blueberry semiconductors. Built India business for Arada Systems Inc. California as Director –India Connectivity, for Wireless & Automotive Wireless business (Arada's Wi-Fi Enterprise (V2X) , that later on was acquired by NETGEAR (NASDAQ: NTGR), Arada's Automotive Business was acquired by LEAR CORPORATION (NYSE: LEA) in 2015, Lear Corporation). Built new IoT business with Dairy Industries, to offer digitization of the dairy supply chain solutions using AI | ML technology. Cofounder & Int. Business Head Kunal Sharma MSc. Electrical - Warsaw University Of Tech. , Poland ( 2022 - 2024 ) EMBA - UPES India Kunal is a seasoned techno sales professional driven by a relentless zeal for life long learning. He is having 17+ years of experience in sales, application and technical support to power utility customers all across the globe. He was recently granted his M.Sc. with final research thesis on "partial discharge measurement techniques" . Kunal is responsible for International sales and marketing of MIIT Initiative. He is also responsible for MIIT's technology tie-ups all across the globe. Skills & Expertise: 15+ years in international sales, marketing, brand building, company compliances, application & technical support etc. Expertise in being a bridge between the end customer and the design / R & D team leading to maximum customer satisfaction. A few key responsibilities handled by Kunal Sharma were: Founder & Tech Head | KPM Engineering Sol., India Founder & Director Technical| Green-Watt Techo Sol., India ASM-HV | Motwane, India Sales & Application Er. | Omicron Energy Sol., India (subsidiary of Omicron Electronics, Austria) Let’s Work Together Get in touch so we can start working together. First Name Last Name Email Message Send Thanks for submitting!
- KPM MDH 8006|PCDH SERIES LI
KPM MDH 8006 , High-Voltage Lithium Battery Discharger is designed for the rapid discharge requirements of high-voltage lithium battery packs, the discharge voltage can reach 800V. It is equipped with a CAN data bus, which can read battery cell data during discharge. It is an ideal device for battery manufacturers and automobile assembly plants to quickly discharge battery packs during storage, transportation, repair and battery recycling. Kit de descarga de batería de 800 V (serie MDH) Descripción general El descargador de batería de litio de alto voltaje KPM MDH 8006 , está diseñado para los requisitos de descarga rápida de los paquetes de baterías de litio de alto voltaje, el voltaje de descarga puede alcanzar los 800V. Está equipado con un bus de datos CAN, que puede leer los datos de las celdas de la batería durante la descarga. Es un dispositivo ideal para que los fabricantes de baterías y las plantas de ensamblaje de automóviles descarguen rápidamente los paquetes de baterías durante el almacenamiento, el transporte, la reparación y el reciclaje de baterías. Solicitud Fabricantes de baterías y plantas de ensamblaje de automóviles: almacenamiento, transporte, reparación y reciclaje de baterías Características funcionales Característica Descarga de alto voltaje: el voltaje máximo de descarga puede alcanzar los 800 V, cumpliendo con los requisitos de descarga de varios paquetes de baterías de litio de alto voltaje Recopilación de datos de celdas: con bus de datos CAN, los datos de celdas se pueden leer durante la descarga Múltiples protecciones: admite protección contra sobredescarga, sobretemperatura, sobrecorriente, inversión de polaridad Nota de voz Catálogo
- LA/MOA Tester/SURGE ARRESTER TESTER/LCM | KPM ENGINEERING SOL. PVT. LTD|LA / MOA Tester
KPM LA100+ is used for testing health of lightning arresters. It is also known as MOA Tester , Surge Arrester Tester/leakage current monitor/LCM etc. KPM LA100+ provides user key parameters such as Resistive Leakage Current ,3rd harmonic leakage current, Watt loss , watt loss angle etc PROBADOR DE PARARRAYOS (LA/MOA) Probador de pararrayos monofásico de KPM(KPM LA-100) es el instrumento especial que se utilizará para detectar las propiedades eléctricas de los pararrayos (LA/MOSA). KPM LA-100 is capable of testing LA en línea utilizando tres métodos principales según IEC: Medición de la corriente de fuga LA directamente Medición directa de la corriente de fuga LA y la tensión del PT de línea para obtener los resultados más fiables según IEC. Medición de corriente de fuga LA y voltaje de PT de línea usando Field Probe según IEC requirements más reciente Características del producto of Lightning Arrester Tester (KPM LA-100+) Pantalla LCD de pantalla grande, menú de usuario en inglés, fácil de usar. Utilice técnicas de muestreo de precisión y análisis armónico de Fourier para obtener datos fiables. Mide la corriente resistiva del tercer armónico, Corriente resistiva total, Corriente de fuga total,_cc781905-5cde-3194-bb3b-136_bad5cf58d en ángulo Batería recargable, reloj de calendario, microimpresora incorporada, puede almacenar 120 datos de medición de grupo Nota de voz Catalogar Nota de voz Catalogar KPM's Probador trifásico de pararrayos(KPM LA-103+) es el instrumento especial que se utilizará para detectar las propiedades eléctricas de los pararrayos (LA/MOSA). KPM LA-103+ is capable of testing LA en línea utilizando seis métodos principales según IEC: 1. Pantalla LCD de pantalla grande, operación de menú en inglés completo, fácil de usar. 2 Usando circuitos de muestreo y procesamiento de alta precisión, técnicas avanzadas de análisis armónico de Fourier para hacer que los datos sean confiables. 3. El instrumento utiliza señales de voltaje y corriente capturadas e ingresadas directamente por un sensor digital de aislamiento magnético de alta velocidad único para garantizar la confiabilidad y seguridad de los datos. 4. Este equipo puede usar un campo eléctrico inducido o un método de transmisión inalámbrica en lugar del cableado secundario PT. 5. El instrumento no necesita conectar PT secundario y puede medir la corriente resistiva directamente. 6. Hay seis métodos de prueba, que brindan muchas opciones para la persona en el sitio. ( PT método secundario, método de inducción, método de transmisión inalámbrica, un método de sincronización de corriente única, método de sincronización secundaria pt) Anchor 1
- Hipot ( Ac/dc/vlf) | KPM Engineering Solutions Pvt. Ltd.|HIPOT ( AC/DC/VLF)
KPM Solutions|We are electrical Test Equipment provider for high quality |HIPOT ( AC/DC/VLF) |https://www.kpmtek.com/hipot HIPOT (CA/CC/VLF) CA HIPOT La serie KPM-AC de HIPOT consta de un solo transformador HV y una caja de control principal. Hay tres tipos de transformadores HV basados en material de aislamiento. Transformador HV seco (aislamiento de resina epoxi) Transformador HV de aceite (aceite de aislamiento) Transformador HV de gas SF6 (aislamiento de gas SF6) Especificaciones del modelo KPM-AC50/30 50kV @ 30mA – 22kg KPM-AC50/60 50kV @ 60mA – 33kg KPM-AC50/120 50kV @ 120mA – 53kg KPM-AC50/200 50kV @ 200mA – 79kg KPM-PIK/50/100 100kV @ 100mA – 98kg Catalogar Catalogar HIPOT DC Consta de una unidad de control y una unidad rectificadora doble. La serie KPM-DC de HIPOT es liviana, portátil y fácil de usar. Estas unidades son fáciles de usar y su salida es estable incluso a altos voltajes Especificaciones del modelo KPM-DC60/10 60kV @ 10mA – 16kg KPM-DC120/10 120kV @ 10mA – 20kg KPM-DC200/10 200kV @ 10mA – 26kg KPM-DC300/10 300kV @ 10mA – 31kg Probador de alto potencial VLF El avance de la tecnología ha traído a nuestra puerta un equipo único que nos permite utilizar una frecuencia extremadamente baja, es decir, 0,1 Hz. Por lo tanto, la única forma de probar en campo cargas de alta capacitancia, como cables y motores/generadores, con voltaje de CA, es usar un probador de voltaje alto VLF. Cuanto más baja sea la frecuencia, menos corriente y potencia se necesitarán para probar cargas de alta capacitancia. El hipoting VLF no es destructivo para un buen aislamiento y no conduce a fallas prematuras como con las pruebas de voltaje de CC. El uso de VLF tampoco provoca la degradación del aislamiento. Por lo tanto, KPM le ofrece el VLF Hipot Tester que brinda protección contra sobrevoltaje y sobrecorriente junto con un cuerpo de aumento de voltaje en el diseño y esto elimina la necesidad de una resistencia de protección adicional conectada al exterior. Catalogar
- Clamp Earth & Spike Tester | KPM Engineering Solutions Pvt. Ltd.|Clamp Earth & Spike Tester
KPM Solutions |Clamp Earth & Tester ,Clamp Earth Tester (KPM-CEST1800) is widely applied in ground resistance measurement, loop resistance measurement, 3 point & 4 point measurement, voltage measurement & leakage current measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industries . PROBADOR DE PINZA DE TIERRA Probador de tierra de abrazadera (KPM-CET1200) is ampliamente aplicado en la medición de resistencia de tierra, loop medición de resistencia en campos como electricidad_cc781905-5cde-3194-bb3b-536badcf5, comunicaciones telecomunicaciones, energía, meteorología , campo petrolero, arquitectura y equipos eléctricos industriales, etc. Al medir el sistema de tierra con bucle, no hay necesidad de desconectar la tierra cable sin auxiliar electrode, lo que significa más seguro y más rápido. Probador de tierra de abrazadera (KPM-CET1200) puede medir la falla a tierra que no se puede medir por el método tradicional, se puede aplicar en la ocasión donde_cc781905-5cde-3194-bbba3b5tradicional los métodos son impracticables; Clamp Earth Tester (KPM-CET1200) mide el integrado_cc781905-5cde-3194-bb3b-136bad5cf_valor de resistencia a tierra y resistencia58d. Probador de tierra de abrazadera (KPM-CET1200) is otra actualización perfecta en modelos antiguos. Especificaciones clave de Clamp Earth Tester (KPM-CET1200) Mide la resistencia de tierra/resistencia de bucle Tamaño de mordaza grande (65 mm x 32 mm) Amplio rango de medición de resistencia (0,01 Ω a 1200 Ω) Amplio rango de medición de corriente (0.01A a 20A) Ideal para probar circuitos de toma de tierra mutuamente conectados como Grid earthing, Mesh earthing,Transmission tower earthing Nota de voz Catálogo
- Relaytestkit ( KF86 ) | KPM Engineering Sol.|RTK ( KF 86 )
KPM brings you advance & powerful automatic relay test kits ideal for all type of relay testing applications. Relay Tester ,Relay Test Set, Portable relay tester, Secondary Current Injection Test set, Current Injection Tester, Relay test Kit, Secondary Current Injection Kit, Secondary Injection Kit JUEGO DE PRUEBA DE RELÉS (KF86) Proposición única: Clasificación de alta potencia y clasificación de alta corriente Ideal para probar relés numéricos y estáticos Peso ligero y diseño de vanguardia (solo <10 kg) Software de última generación (con todas las funciones avanzadas) para probar relés numéricos Características de hardware del kit de prueba de relé universal (KF86): Six fuentes de voltaje de CA independientes de 0-130 V a 65 VA cada una. Seis fuentes de corriente independientes de 0-20 A a 90 VA cada una. Una fuente de CC auxiliar independiente de 0 ~ 300 V/0,6 A. Salidas analógicas de alta precisión de >0,05 %. Adecuado para pruebas de relés numéricos y estáticos LCD de color verdadero de 9,7 pulgadas, pantalla táctil con teclado simple Características del software del kit de prueba de relé universal (KF86): Software altamente avanzado con módulos especializados para probar funciones de Distancia, Diferencial, Sobrecorriente, Autorecierre, Sincronizador, Power Swing, df/dt, etc. Módulos gráficos de prueba y plantillas con función de edición. Pruebas de apuntar y hacer clic Opción de prueba de disparo, búsqueda y verificación Instalación de importación y exportación RIO/XRIO Pruebas de sincronización GPS de extremo a extremo Pruebas de medidores de energía, calibración de transductores, V/I Measurement y registrador de transitorios (opcional). Nota de voz Catálogo - KF86 Certificaciones de calidad Marcado CE LVD 2014/35/UE EN 61010-1-2010 CEM 2014/30/UE EN 61326-1: 2013 EN 61000-3-2:2014 EN 61000-3-3: 2013 Kit de prueba de teoría de relés El relé de protección es un dispositivo que mantiene los equipos del sistema de potencia y proporciona una salida en condiciones anormales para garantizar la protección del sistema. El objetivo básico del relé de protección es aislar la sección defectuosa en un sistema de potencia lo más rápido posible para que el resto del sistema funcione normalmente. Es necesario comprobar la seguridad, fiabilidad, calidad, sensibilidad y velocidad de los relés. Se recomiendan varias pruebas en las normas nacionales e internacionales para verificar la capacidad de resistencia de un relé durante condiciones de falla. Durante la prueba, el relé de protección se somete a condiciones de campo simuladas para comprobar su rendimiento. Los estándares nacionales e internacionales relevantes recomiendan muchas pruebas para determinar la efectividad de los relés para realizar su función prevista. El equipo de protección cuenta con la ayuda de transformadores de instrumentos que detectan las condiciones de energía y los interruptores automáticos que son capaces de desconectar el elemento defectuoso cuando lo solicita el equipo de protección. Debido a su función crítica en el sistema de energía, los relés de protección deben someterse a pruebas de aceptación antes de ponerlos en servicio y periódicamente a partir de entonces para garantizar un rendimiento confiable. En una aplicación industrial normal, se deben realizar pruebas periódicas al menos cada 2 años de acuerdo con el estándar IEC/IS . Kit de prueba de relés: teoría El relé es un dispositivo de conmutación que emite un comando de disparo al disyuntor durante condiciones de falla anormales. Un relé recibe las señales de entrada de los CT/PT y su programa calcula las condiciones de falla según la aplicación. Emite un comando de disparo al disyuntor al detectar una condición defectuosa. Paso 1: El kit de prueba de relés inyecta fallas en forma de I y V en los respectivos puntos CT y PT del relé bajo prueba. El temporizador del kit de prueba de relés comienza iniciando la inyección fault. Paso 2: El relé detecta la falla y emite el comando de disparo, su tiempo de disparo debe depender de las características de tiempo de los ajustes del relé. Paso 3: El kit de prueba de relés recibe el comando de disparo del relé y detiene el temporizador. Etapa 4: Las características de disparo medidas se comparan con respecto al disparo esperado según la configuración del ingeniero. Pruebas de relés electromecánicos El secundario del transformador de corriente está conectado a la bobina de corriente del relé. El secundario del transformador de tensión está conectado a la bobina de tensión del relé. Siempre que ocurra una falla en el circuito del alimentador, la corriente secundaria proporcional del TC fluirá a través de la bobina de corriente del relé debido a que aumenta la mmf de esa bobina. Este aumento de mmf es suficiente para cerrar mecánicamente el contacto normalmente abierto del relé. Este contacto de relé en realidad cierra y completa el circuito de la bobina de disparo de CC y, por lo tanto, la bobina de disparo se energiza. La mmf de la bobina de disparo inicia el movimiento mecánico del mecanismo de disparo del interruptor automático y, en última instancia, el interruptor automático se dispara para aislar la falla.
- CTTC | KPM Engineering Solutions Pvt. Ltd |CT Heat Run - CTTC
KPM Solutions|We are electrical Test Equipment & Epidemic Control solution, provider |CTTC |https://www.kpmtek.com/ctthermalcurrenttestdevice DISPOSITIVO DE PRUEBA DE FUNCIONAMIENTO CON CALOR CT Catalogar Nota de voz El dispositivo de prueba de funcionamiento en caliente del transformador de corriente primero mide el valor de impedancia del bucle de muestra del transformador de corriente conectado y luego controla automáticamente la corriente de salida del dispositivo al valor de corriente de prueba objetivo de acuerdo con el valor de impedancia y el valor de corriente de prueba establecido. Bajo la condición de tiempo de prueba de reloj de 1 s, cuando la corriente de salida calculada y la carga excedan la salida máxima del dispositivo, la corriente de prueba se reducirá de acuerdo con el método de prueba equivalente I2t proporcionado por el estándar y la duración de la prueba se extenderá. El tiempo de prueba más largo se controla en 5 s. Para garantizar que el proceso de prueba se agregue al circuito primario de la muestra I2t y 1s en la prueba de impacto de corriente térmica es numéricamente equivalente Características Mida la impedancia del bucle primario del transformador de corriente de muestra conectado y ajuste el regulador de voltaje eléctrico del dispositivo al valor objetivo de acuerdo con el valor de impedancia medido, y luego genere la corriente de prueba objetivo requerida en el bucle de salida del amplificador. Registre la curva de amplitud-tiempo de la muestra de corriente de bucle primario, voltaje de bucle primario, voltaje de salida del regulador del dispositivo, corriente de salida del regulador del dispositivo, etc. durante la prueba. Controle y supervise automáticamente todo el proceso de prueba para protegerse contra operaciones anormales y erróneas durante la prueba. Genere un informe de prueba de la especificación de formato. Detalles técnicos Corriente de salida máxima 0 ~ 10000 A (se puede personalizar una corriente de salida más grande), el error de corriente de salida es inferior al 10% del valor establecido Capacidad de salida del dispositivo 250KVA Muestra de medición de corriente de bucle primario 0 ~ 10000A, error de medición 0.1% FS Muestra de medición de voltaje de bucle primario 0 ~ 30 V, error de medición 0.1% FS Voltaje del proceso de prueba y tasa de muestreo de forma de onda de corriente 25 KHz, error de medición de tiempo 0,04 ms Fuente de alimentación AC380V45Hz~65Hz Temperatura ambiente de trabajo 0~50 grados, humedad inferior al 90%
- Contact Resistace Tester | KPM Engineering Solutions Pvt. Ltd.|Contact Resistace Tester
KPM CRT Series are robust & accurate range of contact resistance testers used for checking healthiness of bonding resistance , circuit breaker contacts etc. |Contact Resistace Tester |https://www.kpmtek.com/crt MEDIDOR DE RESISTENCIA DE CONTACTO Probador de resistencia de contacto (KPM CRT) outputs DC corrientes para probar la resistencia de contacto de los contactos del cable de alta corriente. Está diseñado según IEC62271. Mide principalmente la resistencia de contacto del interruptor automático. Todos los test results del probador se pueden imprimir con la microimpresora, que está integrada en the tester. Además, todos los resultados de las pruebas guardados en el probador se pueden cargar en la computadora y luego guardarse como documento de MS WORD. Características del producto: Medición de resistencia de contacto Impresión de resultados Cargar los datos a la PC Puntos clave de Probador de resistencia de contacto (KPM CRT) Alta corriente DC hasta 600A Voltaje de milivoltios drop medición. Operación simple Rechazo de interferencia de ruido Resultados rápidos y estables gracias a las fuentes de alta potencia Impresora incorporada con memoria de 100 resultados Conectividad de PC Modo de prueba automático La serie KPM-CRT está disponible en las siguientes variantes: 100A 200A 400A 600A Nota de voz Catálogo