top of page

Search Results

Rechercher sur ce site

91 résultats trouvés avec une recherche vide

  • advertisements | KPM Engineering Solutions Pvt. Ltd.|Gallery

    In KPM Engineering Solution Pvt. Ltd our solutions are Thermal Imager camera, fever monitoring solution, Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing , Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing. Visit www.kpmtek.com for details Galerie vidéo Photos Videos Anchor 1 Galerie vidéo Load More Galerie vidéo All Videos All Videos Lire la vidéo Partager Chaîne entière Cette vidéo Facebook Twitter Pinterest Tumblr Copiez le lien Lien copié Search videos Rechercher une vidéo... Lecture en cours KPM KFA320 00:35 Lire la vidéo Lecture en cours KPM intro (M) 01:16 Lire la vidéo Lecture en cours KPM India - Your Reliable Electrical Test Equipment Solution Provider 01:20 Lire la vidéo Anchor 2

  • LA Test Kit | KPM Engineering

    Advanced lightning arrester test kits by KPM for precise leakage current measurement, condition monitoring, and surge protection testing. TROUSSE D'ESSAI DE PARE-FOUDRE ( LCM ) Testeur de parafoudre 1 Ph en ligne (avec mesure de tension et de courant) Catalogue Le testeur de parafoudres de KPM (KPM LA-100+) est l'instrument spécial à utiliser pour détecter les propriétés électriques des parafoudres (LA/MOSA). KPM LA-100+ is capable of testing LA en ligne en utilisant la mesure du courant de fuite LA et de la tension de ligne PT directement pour la plupart des résultats fiables CEI . Caractéristiques du produit of Testeur de parafoudre (KPM LA-100+) Écran LCD grand écran, menu utilisateur en anglais, facile à utiliser. Utilisez les techniques d'échantillonnage de précision et d'analyse harmonique de Fourier pour obtenir des données fiables. Mesure le courant résistif 3ème harmonique, Courant résistif total, Courant de fuite total,_cc781905-5cde-3194-bb3b-136bad5cfI58d_Angle V-I58d Batterie rechargeable, horloge calendrier, micro-imprimante intégrée, peut stocker 120 données de mesure de groupe Testeur LA triphasé en ligne (avec capteur E sans fil et mesure du courant) Catalogue KPM's Testeur de parafoudre triphasé(KPM LA-103+) est l'instrument spécial à utiliser pour détecter les propriétés électriques des parafoudres (LA/MOSA). KPM LA-103+ is capable of testing LA en ligne en utilisant six méthodes principales selon CEI - : 1. Grand écran LCD, fonctionnement complet du menu en anglais, facile à utiliser. 2 En utilisant des circuits d'échantillonnage et de traitement de haute précision, des techniques avancées d'analyse harmonique de Fourier pour fiabiliser les données. 3. L'instrument utilise des signaux de tension et de courant directement capturés et entrés par un capteur numérique unique à isolation magnétique à grande vitesse pour assurer la fiabilité et la sécurité des données 4. Cet équipement peut utiliser un champ électrique induit ou une méthode de transmission sans fil au lieu d'un câblage secondaire PT. 5. L'instrument n'a pas besoin de connecter le secondaire PT et peut mesurer directement le courant résistif. 6. Il existe six méthodes de test, offrant de nombreux choix pour la personne sur site. ( PT méthode secondaire, méthode d'induction, méthode de transmission sans fil, méthode de synchronisation à courant unique, méthode de synchronisation secondaire pt) Testeur LA triphasé en ligne (avec capteur E sans fil et mesure du courant) Catalogue KPM's Testeur de parafoudre triphasé(KPM LA-103+) est l'instrument spécial à utiliser pour détecter les propriétés électriques des parafoudres (LA/MOSA). KPM LA-103+ is capable of testing LA en ligne en utilisant six méthodes principales selon CEI - : 1. Grand écran LCD, fonctionnement complet du menu en anglais, facile à utiliser. 2 En utilisant des circuits d'échantillonnage et de traitement de haute précision, des techniques avancées d'analyse harmonique de Fourier pour fiabiliser les données. 3. L'instrument utilise des signaux de tension et de courant directement capturés et entrés par un capteur numérique unique à isolation magnétique à grande vitesse pour assurer la fiabilité et la sécurité des données 4. Cet équipement peut utiliser un champ électrique induit ou une méthode de transmission sans fil au lieu d'un câblage secondaire PT. 5. L'instrument n'a pas besoin de connecter le secondaire PT et peut mesurer directement le courant résistif. 6. Il existe six méthodes de test, offrant de nombreux choix pour la personne sur site. ( PT méthode secondaire, méthode d'induction, méthode de transmission sans fil, méthode de synchronisation à courant unique, méthode de synchronisation secondaire pt) Test de parafoudre théorique Theory - LA Tester Parafoudre – Théorie Un parafoudre est un dispositif utilisé sur les systèmes d'alimentation électrique et les systèmes de télécommunications pour protéger l'isolation. et les conducteurs du système contre les effets néfastes de la foudre. Le parafoudre typique a une borne haute tension et une borne de terre. Lorsqu'une surtension de foudre (ou une surtension de commutation) se déplace le long de la ligne électrique jusqu'au parafoudre, le courant de la surtension est dévié à travers le parafoudre, dans la plupart des cas vers la terre. Si la protection échoue ou est absente, la foudre qui frappe le système électrique introduit des milliers de kilovolts qui peuvent endommager les lignes de transmission et peuvent également causer de graves dommages aux transformateurs et autres appareils électriques ou électroniques. Les pics de tension extrêmes produits par la foudre dans les lignes électriques entrantes peuvent également endommager les appareils électroménagers, c'est pourquoi il est sacrément crucial pour l'intégrité du parafoudre. Actuellement, la surveillance du courant de fuite total (courants capacitifs et résistifs) est utilisée par de nombreux services publics. Les moniteurs de courant de fuite sont utilisés pour mesurer le courant de fuite des parafoudres et, en cas de courant de fuite élevé, les parafoudres sont remplacés. Cependant, on estime que cette méthode n'est pas la méthode infaillible car le courant de fuite total, qui est purement capacitif, ne signifie pas précisément la santé des parafoudres. Il y a eu des cas où les parafoudres ont explosé même si la valeur totale du courant de fuite était inférieure à la limite prescrite par les fabricants. Le courant résistif est de 15 à 30 % du courant total et, comme les courants capacitifs et résistifs sont décalés de 90 degrés, même un changement considérable du courant résistif entraîne une très faible augmentation du courant total. Par conséquent, la surveillance du courant de fuite total peut ne pas vraiment indiquer la dégradation du disque ZnO. La dégradation d'un long disque de ZnO linéaire conduit généralement à des harmoniques dans le courant de fuite lorsque la tension du système de fréquence fondamentale est appliquée. La mesure du courant résistif de troisième harmonique est basée sur le filtrage de la composante de troisième harmonique du courant de fuite total. Un courant de fuite de l'ordre d'environ 500 microampères est généralement considéré comme sûr. La partie résistive du courant de fuite ou la perte de puissance peut être déterminée par plusieurs méthodes indiquées ci-dessous : Utilisation d'un signal de tension comme référence Compenser la composante capacitive en utilisant un signal de tension Compensation capacitive en combinant le courant de fuite des trois phases Analyse des harmoniques du troisième ordre Détermination directe des pertes de puissance Analyse des harmoniques de rang 3 avec compensation des harmoniques de la tension Système de surveillance avancé avec calculs de composants "courant résistif". L'utilisation de méthodes de diagnostic avancées réduit considérablement les risques d'échec et évite ainsi les pertes humaines et financières. Il est donc souhaitable de vérifier l'état des parafoudres à intervalles de temps réguliers, en mesurant la composante résistive du courant de fuite continu en service sans mettre le parafoudre hors tension. Des mesures fiables sont réalisées par les instruments basés sur le principe du « signal de tension » comme référence. La surveillance régulière de LA a permis d'éviter de nombreuses défaillances dans les sous-stations de 66 kV à 765 kV. Les valeurs de ce courant varient normalement de fractions de milliampères à quelques milliampères, et sont caractérisées par des variations de courant résistif dont la valeur est un indicateur de la détérioration du Surge Arrester. La composante résistive de ce courant de fuite peut augmenter en raison de différentes contraintes provoquant le vieillissement et provoquant finalement des défaillances du parafoudre. Foire aux questions (FAQ) FAQ about lightning arrester testing : 01 What is a lightning arrester, and why does it need testing? A lightning arrester (LA), also called a surge arrester, protects transformers, switchgear and lines from overvoltages caused by lightning and switching. It sits between the line and earth and, at normal voltage, passes only a tiny leakage current. When a surge arrives it conducts heavily for a moment, sends the surge to earth, then returns to its blocking state.An arrester can deteriorate for years without any visible sign. If it degrades far enough it can overheat and fail, sometimes violently, and it can take the equipment it was protecting with it. Testing finds a deteriorating arrester while there is still time to replace it at a planned outage. 02 Is there a difference between a lightning arrester and a surge arrester? In practice, no. "Lightning arrester" or "LA" is the everyday name in Indian substations, and "surge arrester" is the term used in IEC standards and by manufacturers. Both refer to the same device.Almost all arresters installed today are metal oxide surge arresters (MOSAs), built from a stack of zinc oxide (ZnO) blocks without spark gaps. Older gapped silicon carbide arresters still exist on some networks, but leakage current testing as described here is mainly used on metal oxide arresters. 03 What is thermal runaway in a surge arrester? Zinc oxide conducts more current as it gets hotter. In a healthy arrester the small heat produced at normal voltage escapes easily and the temperature stays stable.In a degraded arrester, more current flows, so more heat is produced. That heat raises the current further, which produces still more heat. If the heat produced outruns the heat the arrester can shed, the temperature climbs until the arrester fails. Rising resistive leakage current is the early sign that an arrester is moving towards this condition. 04 What is an LA tester? An LA tester, or lightning arrester tester, is an instrument for checking the condition of surge arresters. The most useful type for metal oxide arresters is the leakage current analyser: it measures the small current that flows through the arrester to earth at normal service voltage, and works out the resistive part of that current, which is the part that reveals deterioration.Because it works while the arrester stays energised, a leakage current analyser lets a utility check every arrester in a substation without any outage. 05 Why does a healthy lightning arrester leak current at all? A metal oxide arrester is connected between line and earth all the time. At normal operating voltage its zinc oxide blocks behave much like a capacitor, so a small current, usually of the order of a milliamp depending on the arrester's size, always flows to earth.That current has two parts:• A capacitive part, which leads the voltage by close to 90°. It is the larger part and does no harm.• A resistive part, in phase with the voltage. It is small in a healthy arrester and produces the heat.The two together make up the total leakage current.Picture filela-leakage-current-phasor-healthy-vs-aged.pngAlt textPhasor diagram of lightning arrester leakage current showing capacitive and resistive components for a healthy and an aged arresterCaptionTotal leakage current is the sum of a large capacitive part and a small resistive part. As the arrester ages, the resistive part grows. 06 Why is resistive leakage current more important than total leakage current? Because deterioration shows up in the resistive part. When an arrester ages or takes in moisture, its resistive current rises noticeably, while the capacitive current barely changes.The capacitive current is much larger, so it dominates the total. The total current can therefore look almost normal even when the resistive part has risen sharply. A test that reports only total current, like the milliamp meter on many surge counters, can miss a deteriorating arrester. A good LA tester separates out the resistive current. 07 What is the third harmonic method of lightning arrester testing? Zinc oxide is non-linear: its resistive current rises steeply near the peaks of the voltage. That makes the resistive current distorted rather than a clean sine wave, and the distortion appears mainly as a third harmonic (150 Hz on a 50 Hz system).The third harmonic method measures the third harmonic in the arrester's leakage current and uses it as an indicator of the resistive current. It is popular because it needs only a current measurement on the arrester's earth lead, with no voltage connection.Its weaknesses: the system voltage can contain third harmonic of its own, which also drives third harmonic current through the arrester and can push the reading too high or too low; and the relationship between third harmonic and resistive current depends on the arrester's design, so converting one to the other needs the manufacturer's data.Picture filela-leakage-current-waveforms.pngAlt textWaveforms of lightning arrester total leakage current and the distorted resistive current over one power cycleCaptionThe resistive current is small and distorted, peaking near the voltage peaks. That distortion produces third harmonic. 08 What is harmonic compensation in a surge arrester test, and why does it matter? Harmonic compensation corrects the measurement for harmonics present in the system voltage. To do it, the tester also measures a voltage reference, usually from the secondary of a nearby potential transformer (PT/VT). Knowing the actual voltage waveform, it can separate the resistive current caused by the arrester from current caused by distortion in the supply.Compensated measurements are more accurate and more repeatable than current-only measurements, especially in substations with significant harmonic distortion. They are the better choice for baseline readings and wherever the supply voltage carries significant harmonic distortion. 09 Can lightning arresters be tested without a shutdown? Yes. Leakage current testing is designed for energised arresters in normal service. The tester's current lead clips onto the arrester's earth lead or surge counter connection, at earth potential, using a hot stick. Any voltage reference comes from the low-voltage PT secondary or a field probe. Nothing connects to the high-voltage side.That is the main advantage of online testing: a whole substation can be checked in a day without any outage. 10 What is the difference between a surge counter and an KPM LA tester? A surge counter is fitted permanently in the arrester's earth lead and counts how many surges the arrester has discharged. Many also carry a milliamp meter showing total leakage current.An LA tester is a portable instrument that analyses the leakage current in detail, separating the resistive part, compensating for system harmonics and storing results.The surge counter's meter can warn of a large change, but because it shows total current it is not sensitive to early deterioration. Record the surge count with every LA test, so you can relate the arrester's condition to how many surges it has seen. 11 What conditions must an arrester meet for an online leakage current test? The arrester's leakage current has to flow to earth through one path you can measure. In practice:• The arrester stands on an insulated base (insulating feet or pedestal).• It is earthed through a single earth lead, often via a surge counter.An arrester bolted directly to an earthed structure, with no separate earth lead, leaks current to earth through the structure, and its leakage current cannot be measured this way.Picture filela-online-leakage-current-test-concept.pngAlt textConcept diagram of an online lightning arrester leakage current test with the arrester on an insulated base and a clamp on the earth leadCaptionOnline test concept: the arrester stands on an insulated base and its leakage current flows to earth through one lead, where the tester measures it. 12 What does the phase angle in a lightning arrester test tell you? The angle by which the leakage current leads the voltage shows how capacitive the current is. In a healthy arrester the current is almost entirely capacitive, so the angle is close to 90°. As the resistive part grows, the current moves towards being in phase with the voltage, and the angle falls.A falling angle on the same arrester over successive tests is another sign of rising resistive current. Read it alongside the resistive current itself. 13 Which standard applies to lightning arrester leakage current testing? IEC 60099-5, Surge arresters – Selection and application recommendations, gives guidance on monitoring and diagnosing metal oxide arresters in service, including leakage current measurement methods such as the third harmonic method and methods with harmonic compensation. Arrester design and type testing are covered by IEC 60099-4.When buying an LA tester, check that it uses the measurement methods described in IEC 60099-5.

  • Capacitive voltage divider | KPM ENGINEERING SOL. PVT. LTD|Capacitive Voltage Divider

    KPM capacitive voltage divider is used for HV measurement in Partial Discharge Testing and High Voltage Testing| KPM's Capacitive Voltage Dividers are rugged , accurate and of high quality . |https://www.kpmtek.com/capacitive-voltage-divider Diviseur de tension capacitif (non PD)

  • PD Calibrator | KPM India |PD Calibrator

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Calibrator |https://kpmtek.wixsite.com/website/fr/pdcalibrator Calibrateur DP

  • Partial Discharge Testing Equipment by KPM | PD Diagnostics|Partial Discharge

    Advanced partial discharge testing equipment by KPM for precise detection, insulation analysis, and condition monitoring of electrical assets. SURVEILLANCE DE DP ET DE TERRE EN LIGNE KPM PENTA PD (HAND HELD) View more Partial Discharge Detector Penta-PD is an ideal partner for condition-based maintenance programs. Partial Discharge Detector Penta-PD incorporates all 5 types of online PD sensor technology. Information from multiple sensors gives Partial Discharge Detector Penta-PD the versatility to detect various type PD in variety of substation apparatus. KPM PDM-01,Partial Discharge Monitor View more The KPM PDM-01 partial discharge detector stands out as a versatile digital tool within KPM's product range. Featuring a 10.1-inch touch screen, it replaces the traditional oscilloscope tube and physical knob operation, enhancing user convenience. The instrument employs a full touch screen interface, contributing to extended product longevity and incorporates useful features such as automatic correction, high voltage divider ratio settings, and serial communication for uploading test data. KPM PDTI Cable Termination Monitor View more The KPM PDTI system is deployed on primary switching equipment such as ring network switch cabinets, cable termination boxes, and transformer output cables etc. within the power distribution network. Its primary function is to conduct online monitoring of partial discharge, indicating potential short circuits and ground faults in corresponding cable sections, along with real-time temperature monitoring. KPM Corona Pointer View more KPM Corona Pointer is an ideal equipment for condition-based maintenance programs. Online partial discharge testing is a method of inspecting the insulation of electric power systems while equipment remains energized and in service. Corona Pointer is based on online Ultrasonic PD sensor technology. KPM Duo PD - Handheld PD monitoring system View more KPM Duo PD is a handheld partial discharge tester which uses the ultrasonic signal generated by partial discharge to determine the existence and location of partial discharge and combines the real-time displayed images and data to quickly diagnose partial discharge conditions. KPM PDA-01, Partial Discharge Monitor View more The KPM PDA-01 features a split, modular design, with the local discharge signal conditioning module, digital acquisition module, and test voltage acquisition module integrated into the instrument. The powerful local discharge test and analysis system software is installed on the host computer, which connects to the instrument via USB and RS232 serial ports. KPM PD Pulse-8, Online Partial Discharge Monitor View more KPM PD Pulse-8 partial discharge online monitoring device includes a modularly designed partial discharge sensor and a partial discharge data processing terminal. The partial discharge sensor can effectively monitor ultrasonic and transient earth voltage signals. Its sensors are a two-in-one integrated assembly that can be installed on the HV equipment. Foire aux questions (FAQ) FAQ about Partial discharge : 01 What is partial discharge? Partial discharge (PD) is a small electrical spark that bridges only part of the insulation between two conductors at different voltages. The insulation as a whole still holds, but at one weak spot the local electric field is high enough to break down a tiny gap, a gas bubble or a surface path.Each discharge lasts a fraction of a microsecond and carries a minute charge. It repeats every power cycle, though, often thousands of times a second, and over months or years that repeated attack erodes the insulation around it. 02 Why is partial discharge dangerous for high-voltage equipment? Partial discharge is both a symptom and a cause. It shows that the insulation has a defect, and it makes that defect worse. Each discharge damages the material by heat, chemical attack and erosion, and the damaged region grows.In solid insulation, that can lead to electrical treeing and eventually a full breakdown: a flashover or fault that can destroy switchgear, a cable joint or a transformer and cause an unplanned outage. Partial discharge is one of the most common forms of deterioration in medium- and high-voltage insulation, so finding it early is one of the most effective ways to prevent failures. 03 Where does partial discharge occur in electrical equipment? • Internal discharge: in voids, cracks or delaminations inside solid insulation such as cast resin, cable insulation or bushings.• Surface discharge: along an insulating surface that is contaminated, damp or overstressed, for example on bushings, terminations and insulator surfaces inside switchgear.• Corona: in air or gas around sharp edges and points at high voltage.• Floating potential: from a metal part that has lost its connection and charges up to an intermediate voltage.• Free particles: loose metal particles moving in gas-insulated equipment.Each type produces a characteristic pattern relative to the power-frequency voltage, which is how an experienced analyst tells them apart. 04 What is the difference between partial discharge and corona? Corona is one type of partial discharge: discharge in air or gas around a sharp conductor at high voltage, with no solid insulation involved. On overhead lines and in outdoor substations some corona is normal and often harmless, apart from radio interference and power loss.Partial discharge is the wider term. It also covers discharge inside solid insulation and along insulating surfaces, which is much more damaging. Telling corona apart from internal or surface discharge is an important part of interpreting any PD test. 05 What is the difference between online and offline partial discharge testing? Online testing is done with the equipment energised and in normal service. Sensors pick up the signals that partial discharge sends out, with no outage and no extra high-voltage supply. It is ideal for surveys and condition monitoring.Offline testing is done with the equipment disconnected and energised from a separate test source. It allows the voltage to be controlled and the discharge to be measured in calibrated units, which is why it is used for factory acceptance tests and detailed diagnostics. It needs an outage and more equipment. 06 What is IEC 60270 partial discharge measurement? IEC 60270 is the international standard for the conventional, electrical measurement of partial discharge. It uses a coupling capacitor and a measuring circuit, calibrated by injecting a known charge, and reports the apparent charge of the discharges in picocoulombs (pC).It is the method used in factory acceptance tests and in equipment standards that set a pC limit. Most portable online PD testers use non-conventional methods instead (electromagnetic and acoustic sensors, covered in IEC TS 62478), which do not give a pC value but can test equipment in service. 07 How is partial discharge detected? A partial discharge releases energy in several forms, and each can be detected:• An electromagnetic pulse, picked up as transient earth voltage (TEV) on metal enclosures, or as UHF radio waves.• Sound, mostly ultrasonic, picked up through the air or through the enclosure wall.• A current pulse flowing to earth, picked up with a high-frequency current transformer (HFCT) on an earth connection.• Light, heat and chemical by-products, used in some specialised methods.The best method depends on the equipment and on which of these signals can reach the outside of it.Picture filepd-signals-and-detection-methods.pngAlt textDiagram of the signals a partial discharge gives off and the sensor that detects each: TEV, ultrasonic, UHF and HFCTCaptionOne discharge, four kinds of signal, four ways to detect it. 08 What is KPMs TEV (transient earth voltage) partial discharge testing? When partial discharge occurs inside metal-clad switchgear, it sends out a fast electromagnetic pulse. Most of it stays inside the metal enclosure, but some escapes through joints, gaskets and openings and induces a very short voltage pulse on the outer surface of the enclosure. That pulse is the transient earth voltage.A TEV sensor is a capacitive probe held against the outside of the panel. TEV testing is quick, needs no outage and is one of the main methods for surveying medium-voltage switchgear and ring main units. 09 What is KPMs UHF partial discharge detection? Partial discharge in gas or solid insulation produces extremely fast current pulses, with rise times of around a nanosecond, which radiate electromagnetic waves up into the ultra-high-frequency range, from hundreds of megahertz to a few gigahertz.UHF sensors pick up these signals. The method is widely used for gas-insulated switchgear (GIS), where sensors are placed at insulating spacers or inspection windows, and for transformers fitted with UHF sensor ports. Working at these frequencies avoids most corona in air and low-frequency noise, although radio sources in the same band, such as mobile phones and Wi-Fi, can still interfere. 10 How is partial discharge detected in power cables? Along most of a cable's length, metal screens, armour and burial stop electromagnetic and acoustic signals from being picked up outside. A discharge does, however, send current pulses along the cable screen to earth. (At terminations inside switchgear and at exposed cable boxes, TEV, ultrasonic and UHF sensors can also help.)A high-frequency current transformer (HFCT), a clamp-on sensor, placed around the earth connection of a cable termination or joint picks up those pulses. Online cable PD testing with HFCTs is common at terminations, in substations and at link boxes. 11 Is a handheld partial discharge tester the same as continuous PD monitoring? No. A handheld PD tester gives a snapshot: an engineer visits, measures and records. It is ideal for surveying many assets quickly and checking equipment periodically.Continuous monitoring uses permanently installed sensors and records partial discharge all the time. It is used on critical or known-suspect assets where activity may come and go with load, temperature or humidity.Many asset owners combine them: periodic handheld surveys across the network, and continuous monitoring where a survey finds something worth watching closely. 12 Why measure background levels before a KPM partial discharge test? Every PD reading has to be judged against the background: the signal level present even where there is no discharge. A high background can hide real discharge, or make a healthy panel look suspect.Electromagnetic interference affects TEV and UHF readings, and other noise sources affect ultrasonic readings. Measuring the background first tells you how much of each reading is genuine, and whether conditions are good enough to test at all. 13 Does humidity or temperature affect partial discharge readings? Yes. Surface discharge in particular is strongly affected by humidity and condensation: it can be active on a damp morning and quiet in the afternoon. Load and temperature also change discharge activity in cables and transformers.Always record the ambient conditions with every test, and compare surveys taken in similar conditions where possible. Discharge that appears only in damp weather still points to a real problem, often surface contamination or poor sealing. 14 What is a PRPD pattern? A PRPD (phase-resolved partial discharge) pattern plots each detected discharge pulse by its amplitude and by the point in the power-frequency cycle (0° to 360°) at which it occurred, accumulated over many cycles.Different defects discharge at characteristic points in the voltage cycle, so the shape of the pattern is a fingerprint. Internal discharge, surface discharge, corona and floating parts each tend to produce a recognisable pattern, while most random noise does not line up with the voltage cycle. Interference from power electronics is an exception: it is locked to the supply and appears at fixed points in the cycle, so it has to be recognised and excluded. PRPD analysis is the standard way of identifying what kind of discharge is present.Picture filepd-idealised-prpd-patterns.pngAlt textIdealised textbook sketches of phase-resolved partial discharge (PRPD) patterns for internal discharge, corona and noiseCaptionSimplified textbook sketches, not instrument screens. Real patterns vary with the equipment and the measurement. 15 What do dB, dBmV and dBµV mean in KPM partial discharge testing? Partial discharge signals vary over a very wide range, so many instruments show them on a logarithmic decibel (dB) scale.• dBmV is relative to 1 millivolt, often used for TEV readings. UHF readings are often given in dBm, relative to 1 milliwatt.• dBµV is relative to 1 microvolt, often used for ultrasonic readings.Every 20 dB is a tenfold increase in signal amplitude, so a reading 20 dB higher than another is ten times larger, and 40 dB higher is a hundred times larger. FAQ about Monitoring testing : 01 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? Using both TEV and ultrasonic methods together enhances diagnostic accuracy: TEV gives insight into internal discharge severity and location. Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. This dual-method approach is vital for: Preventive maintenance, Avoiding insulation failures, Improving switchgear reliability, and Extending equipment life without needing shutdowns.

  • DCIT | KPM Engineering Solutions Pvt. Ltd.|DCIT ( R & D Initiative )

    KPM Engineering ( A Leading S/S test equipment Company ) and Wellman Power ( A leading CT PT manufacturer ) collaborates to form a Development Center For Instrument Transformers ( DCIT ) with state of art test equipment and standards . It is an initiative to serve power sector @ www.kpmtek.com DCIT - Centre de développement des transformateurs de mesure KPM Engineering (Un équipement de test S/S de premier plan Company, desservant S/S jusqu'au niveau 765KV ) _cc781905-5cde-3194-bb3b-136bad5cf58d Le fabricant CT PT jusqu'à 132KV ) collabore pour former aCentre de développement des transformateurs de mesure ( DCIT ) avec un équipement de test et des normes de pointe. Il s'agit d'une initiative visant à servir Power Sector Customers avec des produits de qualité et de précision inégalés. DCIT se concentre sur trois aspects majeurs des transformateurs d'instruments 1) Conductor 2) Insulation_cc781905 -5cde-3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194- bb3b-136bad5cf58d_3) Core Quelques domaines clés de la R&D en DCIT sont -: Caractérisation de la tension transformateurs de mesure dans des conditions non sinusoïdales Application des transformateurs de mesure dans l'évaluation de la qualité de l'alimentation Performances métrologiques de la tension et du courant transformateurs de mesure en mesures d'harmoniques Détection et correction des erreurs systématiques in transformateurs de mesure Entrer en contact

  • PD DEMO | KPM India |PD DEMO

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD DEMO |https://kpmtek.wixsite.com/website/fr/pd-demo Live PD Dashboard

  • Contact Us | KPM Engineering Solutions|Contact Us

    KPM ENGINEERING SOLUTIONS is an electrical test equipment provider with strong support. Our solutions are Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing, Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing, Thermal Imager Camera, PIK, SIK, AC/DC HIPOT. CONTACTER KPM Bureau de Gurgaon : Numéro de téléphone : +91 124 4001088, Email : sales@kpmtek.com _cc781905-5cde-3194-bb3b- 136bad5cf58d_ (Centre de vente et de service) Bangalore Office : Phone Number : +91 8123950553, Email : blr@kpmtek.com _cc781905-5cde-3194-bb3b -136bad5cf58d_ _cc781905-5cde -3194-bb3b-136bad5cf58d_ (Centre de vente et de service) EU Contact _cc781905-5cde-3194 -bb3b-136bad5cf58d_ : Phone Number :+48 539438443 , Email : sales@kpmtek.com _cc781905-5cde-3194 -bb3b-136bad5cf58d_ _cc781905 -5cde-3194-bb3b-136bad5cf58d_ ( Ventes et assistance technique )

  • Voltage Regulator (Column Type) | KPM India |Voltage Regulator (Column Type)

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Voltage Regulator (Column Type) |https://kpmtek.wixsite.com/website/fr/voltageregulator Régulateur de tension (type colonne)

  • PD - HV Lab | KPM Engineering Sol.|PD - HV Lab

    Expert high voltage testing and partial discharge (PD) analysis. KPM advanced HV lab provides precise diagnostic services to ensure insulation integrity and equipment reliability. Détecteur de décharge partielle NON PD Capacitive Voltage Divider_edited Non PD Capacitive Voltage Divider KPM Non PD Transformer Non PD Test Transformer Calibrator PD Calibrator Non PD Coupling Capacitor01 Non PD Coupling Capacitor Motor driven contact type voltage regular Motor driven contact Motor driven contact type voltage regula Motor driven contact type voltage regular Measuring Impedance Measuring Impedance Intermediate Transformer Intermediate transformer KPM PDA-01 Digital PD Monitor KPM PDM-01 Analog PD Monitor KPM Current Input unit High Current Input Unit

  • PD Detector (Digital) | KPM India |PD Detector (Digital)

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Digital) |https://kpmtek.wixsite.com/website/fr/pd-detector-digital Détecteur PD (Numérique)

  • Cable Testing Equipment by KPM | Fault Location & Diagnostics|CABLE

    Advanced cable testing equipment by KPM for precise fault location, insulation testing, and condition monitoring of power cables. SURVEILLANCE DE DP ET DE TERRE EN LIGNE KPM TAN DELTA 40 KPM TD 40 KPM TD 40 capacitance and tan delta tester is designed for condition assessment of high capacitance & high voltage electrical insulation in high voltage apparatus. It is a measurement instrument that is used with an AC power source and a standard capacitor to form a complete measurement setup. KPM TD 40 is a two-piece design. the control module and the test module communicate wirelessly during the test. KPM DC HIPOT KPM DC HIPOT KPM Portable DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM- DC series of HIPOTs is light weight, portable & easy to use. These units are user friendly & its output is stable at even high voltages DC vs AC High-potential Testing Direct current high-potential testing provides several advantages over alternating current. KPM VLF Series KPM VLF Series KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. KPM AC HIPOT KPM AC HIPTO KPM Portable AC/DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM-AC/DC series of HIPOTs is light weight , portable & easy to use. These units are user friendly& its output is stable at even high voltages it is the basic test equipment used by the power station, transmission and distribution companies for testing the insulation strength of all kind of electrical products, electrical equipment and insulated materials. KPM VLF Hipot Tester KPM VLF Hipot Tester KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. Foire aux questions (FAQ) FAQ about Cable testing : 01 1. What is VLF testing, and why is it used for cable diagnostics? VLF (Very Low Frequency) testing applies a low-frequency AC voltage—typically 0.01 Hz to 0.1 Hz—to power cables to assess their insulation condition. It’s used because VLF testing can apply a high voltage stress similar to normal operating conditions but with less heating and damage risk than standard power frequency tests. This makes it ideal for diagnosing medium- and high-voltage cables, especially in field conditions, to detect weaknesses like insulation degradation, voids, or defects before failure occurs. 02 2. How does VLF testing differ from conventional AC hipot testing? VLF testing uses a very low frequency (typically 0.01 to 0.1 Hz) AC voltage, whereas conventional AC hipot testing applies standard power frequency (50/60 Hz) voltage. The low frequency in VLF reduces the capacitive charging current in long cables, allowing high test voltages without overheating the cable insulation. This makes VLF safer and more practical for field testing of long medium- and high-voltage cables. In contrast, conventional AC hipot tests can cause excessive heating and damage when used on such cables. 03 3. What types of cable defects can VLF testing detect? VLF testing is effective at identifying a wide range of insulation defects and weaknesses within medium- and high-voltage power cables. It can detect partial discharge (PD) activity, which is a common early indicator of insulation deterioration such as microscopic voids or cracks within the cable’s insulation material. These PD sites generate localized electrical discharges that degrade the insulation over time, potentially leading to catastrophic failure if not addressed. Additionally, VLF testing can reveal water ingress problems, where moisture penetrates the insulation and lowers its dielectric strength, as well as contamination or aging effects such as thermal, mechanical, or chemical degradation of the insulation material. It can also uncover manufacturing defects like thin spots, improper curing, or insulation gaps. While VLF testing is excellent for assessing the overall integrity of the cable insulation and detecting areas of weakness, it may not precisely locate the defects. For detailed localization, it is often combined with other techniques such as partial discharge (PD) measurements or time-domain reflectometry (TDR). 04 4. What is Tan Delta (VLD) testing, and how does it assess cable insulation quality? Tan Delta (also called Very Low Dissipation factor or VLD) testing measures the dielectric losses in cable insulation by applying an AC voltage and analyzing the phase difference between the current and voltage. The "tan delta" represents the ratio of resistive (lossy) current to capacitive (ideal) current. A low tan delta value indicates good insulation with minimal energy loss, while higher values suggest deterioration due to moisture, contamination, or aging. By measuring these losses, Tan Delta testing assesses the overall insulation condition and detects early-stage degradation before catastrophic failure. It is highly sensitive to insulation quality changes and is commonly used for condition assessment and preventive maintenance of medium- and high-voltage cables. 05 5. How do Tan Delta results indicate the health or degradation of a cable? Tan Delta results reflect the insulation’s dielectric losses, which increase as the cable ages or deteriorates. A low tan delta value means the insulation is healthy, with minimal leakage current and good dielectric integrity. Conversely, a rising tan delta value indicates increasing insulation defects such as moisture ingress, contamination, cracks, or thermal aging. Trends in tan delta over time are especially important: a gradual increase suggests progressive degradation, allowing maintenance teams to plan repairs before failure occurs. Sudden spikes may point to acute damage or contamination. Thus, monitoring tan delta values helps assess the insulation’s condition, predict remaining service life, and prioritize maintenance actions. 06 6. What is VLF Partial Discharge (PD) testing, and how does it help's identify insulation defects? VLF Partial Discharge (PD) testing uses very low frequency voltage to stress the cable insulation while detecting and measuring partial discharges—tiny electrical sparks that occur within insulation voids or defects. These discharges are often early signs of insulation failure, caused by imperfections like cracks, voids, or contamination. By capturing PD activity, VLF PD testing helps pinpoint insulation defects before they lead to catastrophic cable failure. It provides valuable insight into the type, location, and severity of defects, enabling targeted maintenance and reducing unplanned outages. This makes it a crucial tool for proactive cable condition assessment. 07 7. Can VLF PD testing detect early-stage insulation failures? Yes, VLF Partial Discharge (PD) testing is specifically designed to detect early-stage insulation failures. Partial discharges are small electrical sparks that occur in microscopic voids, cracks, or impurities within the cable insulation—often long before a complete breakdown happens. By applying very low frequency voltage, VLF PD testing stresses the insulation gently but effectively, allowing detection of these early PD activities. Detecting partial discharges early helps identify weak spots or developing defects in the insulation, enabling maintenance teams to address issues proactively, extend cable life, and avoid costly unplanned failures. 08 8. What are the typical test voltages and frequencies used in VLF cable testing for 11 kV and 33 kV cables? For 11 kV cables, the VLF test voltage typically ranges from 15 kV to 33 kV, depending on the test type—diagnostic tests usually use about 1.5 times the rated voltage (around 16.5 kV), while withstand tests may apply up to 2.5 to 3 times the rated voltage (up to ~33 kV). For 33 kV cables, the test voltage typically ranges from 45 kV to 75 kV, with diagnostic tests at around 1.5 times the rated voltage (approximately 49.5 kV), and withstand tests potentially up to 2.5 times rated voltage (about 82.5 kV), though the upper limit depends on cable specifications and standards. In both cases, the frequency used is very low—typically 0.1 Hz—to reduce capacitive currents and minimize heating during testing, making it safe and effective for long cable lengths. 09 9. How do environmental factors affect VLF, Tan Delta, and PD test results? Environmental conditions like temperature, humidity, and soil moisture can significantly impact VLF, Tan Delta, and Partial Discharge (PD) test results. Temperature: Higher temperatures generally reduce insulation resistance and can increase Tan Delta values and PD activity due to increased molecular activity in the insulation. Low temperatures can raise resistance but might mask some defects. Humidity and Moisture: Moisture ingress lowers insulation resistance and increases dielectric losses, causing higher Tan Delta readings and more PD activity. Wet conditions can lead to more apparent insulation degradation during testing. Soil Conditions: For underground cables, soil resistivity and moisture affect grounding and test current paths, influencing VLF and PD measurements. Dry or rocky soils may lead to higher resistance readings. Surface Contamination: Dirt, oil, or salts on cable surfaces can cause surface discharges, impacting PD and Tan Delta results. Because of these factors, it’s important to consider and document environmental conditions during testing and, where possible, perform tests under similar conditions for consistent trending and accurate diagnostics. 10 10. What are the safety precautions and best practices during VLF and PD cable testing? Ensure Proper Training: Only qualified personnel familiar with high-voltage testing and equipment should conduct tests. Use Appropriate PPE: Wear insulated gloves, safety glasses, and flame-resistant clothing. Clear the Test Area: Establish a safe perimeter with warning signs and barriers to prevent unauthorized access during testing. Verify Equipment Condition: Check all test instruments, leads, and connections for damage before use. De-energize and Ground Cables: Ensure the cable is disconnected from the power system and properly grounded before connecting test equipment. Follow Manufacturer Guidelines: Use the recommended test voltages, durations, and procedures specific to the cable type and equipment. Monitor Test Parameters: Continuously observe voltage, current, and PD activity during the test to detect abnormalities early. Avoid Testing in Hazardous Environments: Do not perform tests during storms, wet conditions, or explosive atmospheres. Record Test Data Accurately: Document all parameters, environmental conditions, and observations for traceability and analysis. Emergency Preparedness: Have clear procedures for immediate shutdown and emergency response in case of equipment failure or personnel hazard. Following these precautions ensures safety and reliable test results while protecting both personnel and equipment.

bottom of page