top of page

Search Results

Rechercher sur ce site

91 résultats trouvés avec une recherche vide

  • Members | KPM India |Members

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Members |https://kpmtek.wixsite.com/website/fr/members

  • form page | KPM India |form page

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|form page |https://kpmtek.wixsite.com/website/fr/form-page Customer Information Contact Person: Designation and Dept. Company Name: Phone Number: Email Address: Website (if any): Location (City, Country): Machine Requirements Machine application If application is not mentioned * Make/Brand Model (Please mention "not decided" in case model is not finalised by you) Mention detailed specification and purpose of machine Expected Purchase Timeline (in months) Immediate 1–3 months 3–6 months 6 or more Expected Budget in lakhs Submit

  • Demo Registration | KPM India |Demo Registration

    Register today for demonstrations of KPM Electrical Testing Equipment. Formulaire de demande de service

  • KPM Relay Testing Kits | Advanced Relay Testing Solutions|Relay Testing

    KPM relay testing equipment with high current rating, precision & advanced software. Ideal for distance, differential, df/dt & protection relay testing. KIT DE TEST DE RELAIS UNIVERSEL KF86 P , (6I , 6V & CEI 61850) 10Kg Blog technique Le KF 86P est un kit de test de relais automatique avancé, puissant et très précis, idéal pour tous les types d'applications de test de relais. Puissance nominale élevée et courant nominal élevé Kit de test de relais idéal pour tester les relais électromécaniques High Buden Conception légère et à la pointe de la technologie (10 KG uniquement) Logiciel de pointe (avec toutes les fonctionnalités avancées) pour tester les relais numériques Conforme IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc. (facultatif) Caractéristiques matérielles du kit de test de relais universel (KF86P) : Six sources de tension CA indépendantes de 0 à 310 V à 105 VA chacune. Six sources de courant indépendantes de 0 à 35 A à 425 VA chacune. Une source CC auxiliaire indépendante de 14 ~ 300 V . Sorties analogiques de haute précision de <0,15 % rd + 0,05 % rg, Guar. Convient pour tester les relais numériques et électromécaniques Test de transducteur et de compteur d'énergie (en option dans le kit de test de relais) KFA 300 , (3I & 3U ) , 3Kg Blog technique Proposition unique : Kit de test de relais le plus léger de < 3 kg avec o/ps analogique Sources de courant : 3 X 10 A Sources de tension : 3 X 265 V Écran et batterie intégrés Idéal pour tester les relais numériques et statiques Fonction logicielle Fonction de test AC manuel/auto Fonction de test du séquenceur d'état Fonction de testeur de disjoncteur de surintensité Fonction à distance (signal, mesure, contrôle) Fonction de test de signal à distance KFA 300 , (3I & 3U ) , 3Kg Blog technique Proposition unique : Kit de test de relais le plus léger de < 3 kg avec o/ps analogique Sources de courant : 3 X 10 A Sources de tension : 3 X 265 V Écran et batterie intégrés Idéal pour tester les relais numériques et statiques Fonction logicielle Fonction de test AC manuel/auto Fonction de test du séquenceur d'état Fonction de testeur de disjoncteur de surintensité Fonction à distance (signal, mesure, contrôle) Fonction de test de signal à distance Kit de test de relais - K68I (3I & 4 U ) Blog technique K68i est un kit de test de relais puissant et robuste pour le test semi-automatique et manuel des relais. Caractéristiques matérielles of Relay Test Kit K68i : Testeur de relais design tout-en-un avec écran LCD de 6,4 pouces. Four sources de tension AC indépendantes de 0-300V @ 110VA chacune. Trois sources de courant indépendantes de 0 à 35 A à 450 VA chacune. Une source CC auxiliaire indépendante de 0 ~ 300 V/0,6 A. Sorties analogiques haute précision of <0.15%rd + 0.05%rg,Guar. Port compatible avec le projecteur for objectif de formation et d'étude. Conception robuste avec encodeur rotatif à très longue durée de vie + clavier fonctionnel. Caractéristiques logicielles du Universal Relay Test Kit K68i : Capable de tester la plupart des relais en mode manuel ou semi-automatique - Relais de tension, relais de courant, relais de fréquence, relais de puissance, relais d'impédance, relais harmoniques, relais de distance, etc. Avec fonction d'auto-logement et de détection de mise à la terre Video Relay Test Kit Vidéos - Kits de test de relais Relay Test Kit Videos Relay Test Kit Videos Lire la vidéo Partager Chaîne entière Cette vidéo Facebook Twitter Pinterest Tumblr Copiez le lien Lien copié Search videos Rechercher une vidéo... Lecture en cours KPM KFA320 00:35 Lire la vidéo Lecture en cours Random check on K3063i universal relay test kit with fluke 6.5 digit multimeter . 01:10 Lire la vidéo Lecture en cours KFA 300 , Lightest Relay Test Kit ( 3.5 KG ) 07:29 Lire la vidéo Théorie - Test de relais Theory -Relay Test Kit Kit de test de relais - Théorie Le relais de protection est un dispositif qui maintient les équipements du système d'alimentation et donne une sortie dans des conditions anormales pour assurer la protection du système. L'objectif fondamental du relais de protection est d'isoler la section défectueuse dans un système d'alimentation le plus rapidement possible afin que le reste du système fonctionne normalement. Il est nécessaire de vérifier la sécurité, la fiabilité, la qualité, la sensibilité et la rapidité des relais. Divers tests sont recommandés dans les normes nationales et internationales pour vérifier la capacité de tenue d'un relais dans des conditions de défaut. Pendant les tests, le relais de protection est soumis à des conditions de terrain simulées pour vérifier ses performances. Les normes nationales/internationales pertinentes recommandent de nombreux tests pour vérifier l'efficacité du relais à remplir sa fonction prévue. Un relais reçoit les signaux d'entrée des TC/PT et son programme calcule les conditions de défaut selon l'application. Il envoie une commande de déclenchement au disjoncteur lors de la détection d'une condition défectueuse. Sur la base de l'application, le relais peut être classé dans les types ci-dessous : Étape 1: Le kit de test de relais injecte un défaut sous forme d'I & V sur les points CT & PT respectifs de Relay under test. Le kit de test de minuterie de relais démarre en initiant l'injection de fault. Étape 2: Le relais détecte le défaut et émet la commande de déclenchement, sa temporisation de déclenchement doit dépendre des caractéristiques temporelles des réglages du relais. Étape 3: Le kit de test de relais reçoit la commande de déclenchement du relais et arrête la minuterie. Étape 4: Les caractéristiques de déclenchement mesurées sont comparées au déclenchement prévu selon les paramètres définis par l'ingénieur. La connexion de base du relais de protection a été montrée dans l'image. Le secondaire du transformateur de courant est connecté à la bobine de courant du relais. Le secondaire du transformateur de tension est connecté à la bobine de tension du relais. Chaque fois qu'un défaut se produit dans le circuit d'alimentation, le courant secondaire proportionnel du TC circule dans la bobine de courant du relais en raison de laquelle mmf de cette bobine augmente. Cette mmf augmentée est suffisante pour fermer mécaniquement le contact normalement ouvert du relais. Ce contact de relais ferme et complète le circuit de la bobine de déclenchement CC et, par conséquent, la bobine de déclenchement est excitée. Le mmf de la bobine de déclenchement initie le mouvement mécanique du mécanisme de déclenchement du disjoncteur et finalement le disjoncteur est déclenché pour isoler le défaut. Types de relais selon diverses exigences : Différentiel Relais Surintensité Relay Actionné en fréquence relais Surintensité directionnelle Relay Défaut à la terre restreint Relay Sur Fluxing Relay Schémas de distance Relais Protection barre bus Relais Reverse Power Relay Perte d'excitation Relais Séquence Ph. Négative Relay Compteurs d'énergie Relais Transducteurs Relais Lecture de défaut Relais Foire aux questions FAQ-RTK FAQ about all our Relay testing Software 01 What can KPM relay testing software test? Protection relays and IEDs across the common functions, plus two instrument families. The basic modules cover AC/DC injection, ramping, state sequencing, harmonics, frequency and transient playback. The function modules add distance, overcurrent, differential, differential configuration, harmonic restraint, auto-reclose, synchronism check and power swing. On the digital side it tests IEC 61850 protection and IEDs using GOOSE and sampled values, and merging units. Two licensed optional modules extend it to energy meter and transducer calibration. The Test Center then chains any combination of those into a single automated run.Protection relays and IEDs across the common functions, plus two instrument families. The basic modules cover AC/DC injection, ramping, state sequencing, harmonics, frequency and transient playback. The function modules add distance, overcurrent, differential, differential configuration, harmonic restraint, auto-reclose, synchronism check and power swing. On the digital side it tests IEC 61850 protection and IEDs using GOOSE and sampled values, and merging units. Two licensed optional modules extend it to energy meter and transducer calibration. The Test Center then chains any combination of those into a single automated run.The six basic modules on the startup page. Advanced and additional tabs hold the function-specific ones — distance, overcurrent, differential, reclose, synchroniser and power swing. 02 What PC do I need to run KPM relay test kit software? Windows 7 SP1 through to Windows 11. On Windows 7 you also need .NET Framework 4.0, and 8 or 8.1 must be 64-bit. Installation requires administrator privileges — right-click the installer and choose “Run as administrator”, or it will fail part-way. Screen resolution must be at least 1024 × 768, though in practice the impedance and characteristic editors are far easier to work with on a larger display. One recommendation from the manual that is not a hardware requirement but matters more than any of the above: run it on a dedicated machine that is not connected to an external network. 03 How do I connect a KPM relay test kit to my laptop? Over Ethernet, and the only thing to get right is the addressing. The kit leaves the factory on 192.168.1.123. Set the laptop to anything else on that subnet — 192.168.1.x where x is 1 to 254 but not 123 — with subnet mask 255.255.255.0, then connect the cable. The software shows the connection state at the top right of the window, reading either “Connected” with the kit's IP address or “Not connected”.The whole connection procedure in one picture. The kit ships on 192.168.1.123; the laptop goes anywhere on 192.168.1.x except .123, subnet mask 255.255.255.0 04 Why won't my KPM relay test kit connect to the software? Two causes account for almost all of it. First, the laptop and the kit are on different subnets: the software will display the kit's IP address but never complete the connection, and will keep retrying indefinitely — which looks like a fault but is just an addressing mismatch. Check the laptop's IP is on the same segment. Second, the Windows firewall is blocking the connection; confirm it is not filtering the software. If the laptop has more than one network adapter, check you have configured the one the cable is plugged into. 05 Can I use KPM relay testing software offline, without the kit connected? Yes, and it is a genuinely useful way to work. Opening the System Settings dialog with no kit connected lets you import an offline device configuration file, after which you can explore every feature and build complete offline test templates. That means the whole preparation job — importing relay settings, defining the test object, laying out modules, adding test points — can be done at a desk the evening before, so the site visit is spent testing rather than typing. The software is in any case designed to run entirely offline; it needs no internet connection at any point.Relay settings in on the left, reports out on the right. Everything between happens inside the Test Center, and all of it can be built with no kit connected. 06 What are the main parts of the KPM relay test kit software screen? Eight regions. The title bar and the menu and toolbar across the top; the Test Center tree down the left, holding the test object and its modules; the main test view in the centre where parameters and test points are entered; the vector view and the characteristic view on the right; a dock area along the bottom carrying history, binary input and output status, alarms and the auxiliary DC indicator; and the status bar. The two views on the right are the ones worth learning first: they show what is about to be injected and where the test point falls against the relay's own characteristic, both before anything runs.Eight regions, and the two that matter most sit on the right: the vector view shows what is being injected and the characteristic view shows where the test point falls against the relay's own curve. Both update before you run anything. 07 Is the KPM relay testing software safe to use on a secure or isolated network? It is designed for exactly that. The software functions entirely offline and needs no network access of its own, which makes it suitable for isolated substation environments. The manual sets out the practices to go with that: run it on a dedicated PC not connected to any external network, use USB drives that have been scanned for malware before and after use, take software updates only from KPM through verified offline channels, and follow your own organisation's IT and cyber-security policy. Unauthorised modification or unintended network connection is outside what KPM supports. 08 What output types does a KPM relay test kit support? Six, selected in System Config. Power amplifier for conventional analogue voltage and current injection, which is what most work uses. Low-level output when the signal is going into an external amplifier. And four digital modes — IEC 61850-9-1, IEC 61850-9-2, FT3 and collector — where the kit publishes digital sampled values instead of analogue signals. Selecting a digital mode automatically reveals the relevant configuration tabs in the menu bar. Whichever you choose, the configuration is not live until Apply is pressed; if the kit is not connected you will get “Failed to send configuration”.One screen decides what the kit actually emits. Note the Apply button at bottom right — nothing is sent to the kit until it is pressed 09 How do I wire the current outputs of a KPM relay test kit? It depends on how much current you need against how many channels. A six-channel kit can run six currents independently, or parallel group 1 with group 2 for three higher-current channels, or split three plus one, one plus three, or one plus one, or output three DC currents with group 2 shorted to ground. A three-channel kit offers three independent, one paralleled three-phase, or three DC. The trade is always the same: paralleling buys current at the cost of channels. Two of the paralleled arrangements are only effective in the AC test, ramp and state sequence modules.Six independent current channels, arranged as two groups of three. Paralleling the groups trades channel count for current, which is how a single kit covers both a three-phase distance test and a high-current differential test. 10 When does the auxiliary DC output become unavailable on a KPM relay test kit? When you need the voltage channels instead. On a four-voltage-channel kit you get four-phase voltage output plus auxiliary DC. On a seven-channel kit you choose: seven independent phase voltages with no auxiliary DC, or five-phase voltage plus auxiliary DC — and enabling the auxiliary DC in that second arrangement makes the group 2 Ib and Ic voltage channels unavailable. Worth knowing before a job, because discovering it on site means rethinking the test 11 What is the auxiliary DC output on a KPM relay test kit for? Powering the protective device under test, so you do not need a separate station battery supply or bench PSU at the test position. Selectable levels run from 24 V up to 350 V, with an “Other” entry for values in between. It is independent of every test module — nothing any module does affects it — and it can be switched on from the status bar of any module rather than having to leave what you are doing. When it is live, the auxiliary DC indicator on the startup page and in every module's status bar turns green. 12 Can a KPM relay test kit test IEC 61850 IEDs with sampled values? Yes, in either 9-1 or 9-2, selected to match what the IED under test actually uses. The configuration covers sample rate, ASDU count, flip mode and sync mode, then per-IED details — MAC destination and source, APPID, VLAN ID, priority, port and a test flag — and the SVID, nominal delay and version. Channels are then mapped to the fibre. None of this needs typing by hand: import the station's SCD, CID or ICD file, or a previously saved configuration, and use the “configure as group 1 to 6” buttons to finish quickly. Once mapped, the channels apply across every test module.Sampled-value configuration. The tedious part — MAC addresses, APPIDs, SVIDs, channel mapping — is avoided by importing the station's SCD, CID or ICD file. 13 What is GOOSE mode on a KPM relay test kit? It replaces the physical binary wiring with GOOSE messages. Set the binary type to GOOSE and the kit publishes and subscribes instead of using its contact terminals — a binary output becomes a GOOSE publisher, a binary input becomes a GOOSE subscriber. Configuration covers GocbRef, GoID, dataset name, allowed time and the T0 to T3 retransmission times, and again SCL import does most of the work. A message detection function will scan for and identify the GOOSE signals actually present on the network, which saves guessing. The practical point: once mapped, every test module works exactly as it does with wired contacts.GOOSE mapped to binary channels. A publisher takes the place of a binary output and a subscriber takes the place of a binary input, so every test module then works unchanged. 14 What is the difference between relay contact and GOOSE binary types? Where the trip signal travels. Relay contact uses the kit's physical binary input and output ports — banana plugs or a combination connector — to send and receive binary signals, and each input can be configured as potential free (wet or dry contact) or, on some models, to trigger on a voltage threshold with a nominal voltage and a reaction threshold percentage. GOOSE sends and receives the same binary signals over the mapped GOOSE channels instead. Both can be active together, which is how a part-digital substation gets tested in one pass. 15 What is a virtual binary input in KPM relay testing software? A software button that simulates an external binary input signal, letting you trigger a state transition from the keyboard rather than needing a real contact to close. It is useful when developing a test template offline, or when the signal you want to trigger on is not conveniently wired. To use it you first map the software button to a binary input channel in the Binary section of the software settings, then enable it under virtual digital inputs in System Config. 16 What is the deglitch time, and why does it matter for trip-time accuracy? It filters transient spikes on the trip signal so that contact bounce is not recorded as an operation. The setting range is 0 to 25 ms and it is entered on the Device tab of the test object. The rule is simple: a binary input change is only recorded if it lasts longer than the deglitch time. With a deglitch time of 15 ms, a flip shorter than that is ignored. This is worth understanding because it cuts both ways — too short and contact bounce produces spurious operations, too long and a genuinely fast trip is filtered out along with the noise. 17 What is a test object in KPM relay testing software? The software's model of the relay you are testing, holding its settings so every module can work from one source. It is organised by protection function — Device, Distance, Overcurrent, Differential, Synchroniser, Transducer, VI Starting and CB — and every type except Device can hold several data instances, so one test object can carry multiple setting groups for the same relay. The test object does two jobs beyond storage: it calculates the expected result for each fault condition, against which the measured result is compared to give a pass or fail; and it generates a visual representation of the relay's characteristics that you can click to place test points.The Device tab is the top of the test object. Nominal values entered here drive every module's primary-to-secondary conversion, and the deglitch time set here governs trip detection throughout. 18 How do I import KPM relay settings into the KPM relay test kit software? Through the Test Object Converter, reached from the “Edit / Import .krt Template” button inside the test object. The converter uses a filter that mirrors the relay manufacturer's own data structure, so the settings sit where an engineer familiar with that relay expects them. Three steps: open the template for the relay you are testing and go to Test Object → Edit; either type the protection settings in or use Import to read them from the relay setting software; then confirm and save them into the test object. Where a template carries several filters for one relay family, the one reporting more matches is generally the better fit.The converter mirrors the relay manufacturer's own data structure, so settings can be read across rather than retyped. Where several filters exist for one relay family, the one reporting more matches is the better fit. 19 What file formats can a protection KPM relay test set import settings from? RIO, RIO3 and XRIO, plus direct import from relay setting software through the converter filter. RIO is the compatibility format, readable by both version 2.x and 3.x of the software, but it cannot carry everything — more than three elements in an overcurrent element type, for instance, will not export to it. RIO3 is the current format and is version 3.x only. An XRIO file can be imported provided it contains RIO object data; if it does not, the software will tell you the file is invalid rather than importing something incomplete. 20 What is a test template, and why does it save time? A saved .krt file holding the test object, every test module you organised under it, and all your user-defined test points. Once a relay type is set up, the template loads the whole arrangement in one step, so the second and every subsequent unit of that type is tested without rebuilding anything. For a testing contractor working through a substation full of identical feeders, this is the difference between a day and a week. Completed tests can additionally be saved as an XML report, which can be reloaded later to view results and parameters, or used interchangeably with a template. 21 What is the Test Center, and how does automated relay testing work? The Test Center is where modules are organised into a sequence that runs on its own. The structure is hierarchical: a Bay at the top, test objects beneath it, and test modules under each object, optionally collected into groups. Every node has an activation checkbox, and only ticked nodes are used. Then Start All runs from the first active module to the last and stops; Start One runs only the module at the cursor; Continue runs from the cursor to the end. That is what “one-click testing” means in practice — a full commissioning sequence for a relay, started once and left to finish. 22 How does System Config scope work in the Test Center? Each test object must have at least one System Config module, and the software adds a default one in first position automatically. A System Config applies only to modules at the same or a lower level that come after it — never to modules before it or above it. Where two System Configs would both apply, the nearest one to the module wins. One trap worth knowing: if a System Config's own activation checkbox is not ticked, its scope does not take effect at all and the modules that would have used it fall back to the default. 23 Can a relay test template adapt automatically when the protection settings change? Yes, and for anyone maintaining general-purpose templates this is the most useful feature in the Test Center. Using “From Reference” on a module's right-click menu, that module's activation checkbox can be linked to a boolean parameter in the test object. When the relay's settings change — a function enabled or disabled — the corresponding test module activates or deactivates itself to match, with no editing. A linked node shows a blue background and its checkbox is locked until the reference is removed. 24 What is the Test Delay module for in an automated test sequence? Pausing an automated run so a person can do something. Dropped between modules in the Test Center, it displays a prompt — text, an image, or both — and waits, with the wait set as Manual, Time, or Manual plus Time. That covers the real interruptions in a commissioning sequence: change a setting group, move a lead, confirm a link position. It can also invoke an external application, though note the limit — the software calls the external program but does not manage or check its results. 25 How do I test a distance relay with a KPM relay test kit? Define the relay's zones in the Distance tab of the test object first — line length and angle, PT position, CT starpoint, grounding factor and a zone list with trip times — and the software draws the resulting characteristic. Then in the Distance module, place test points in the impedance plane by right-clicking on it or by typing |Z|, Phi, R and X. Points are sorted automatically by fault type and linked to the impedance view. Two settings are worth checking twice: PT position decides whether post-fault voltage is zero or nominal, and CT starpoint direction shifts the injected current by 180° if it is wrong.Zones defined on the left, characteristic drawn on the right. PT position and CT starpoint are the two settings most often left wrong — the starpoint choice alone shifts the injected current by 180°. 26 What is the difference between a shot test and a search test? A shot test checks specific points: you choose impedances, the kit injects each one, and the result is whether the relay tripped and how fast at each. A search test finds the boundary: you define a line through the characteristic and the software fires a series of shots along it, narrowing down until it has located the actual reach, with the number of shots calculated from the zones and the search resolution. One rule governs search lines — one end must be inside the zone and the other outside, because if both ends are on the same side there is no boundary to find. 27 What do the I=Constant, U=Constant and Z=Constant fault models mean? Which quantity the software holds fixed while it calculates the other. I=Constant fixes the test current and calculates the fault voltage. U=Constant fixes the test voltage and calculates the fault current. Z=Constant fixes the source impedance and calculates both from it and the test point. Two automatic protections apply: if the calculated fault voltage would exceed nominal × 0.9 the module reduces the test current, and if the calculated fault current would exceed the kit's maximum output it reduces the test voltage. The model is a global setting and applies to both shot and search tests. 28 How do I test an overcurrent relay with IDMT curves? Define the elements in the Overcurrent tab of the test object — phase, residual, positive, negative or zero sequence — each with its characteristic, pickup as a multiple of nominal current, time multiplier and direction. Standard IDMT, I²T and IAC characteristics are built in with their own constants, and custom curves can be entered as a current-time table. Then add test points on the characteristic view by right-clicking or entering test current and angle. All enabled elements operate in parallel and the combined curve is shown on the resulting characteristic tab — which is what the test is actually judged against, not the individual element curves.Elements on the left, the IDMT equation and its constants below, the resulting curve on the right. Every enabled element operates in parallel, and the combined curve is what the test is judged against. 29 What does “load current too high” mean on an overcurrent test point? That the test point cannot be reached with the load current you have set. The point appears as a red circle on the characteristic and the assessment says so explicitly, which is the software refusing to run a test it knows would be invalid rather than producing a misleading number. The fix is to reduce the load current setting. It is worth knowing this is a module constraint and not a relay problem — the point itself is testable, just not with that much prefault load current on top of it. 30 How do I test a differential relay bias characteristic? Set the protected object up first in the Differential tab — transformer, generator, motor or busbar; winding count and reference winding; per-winding power, voltage, CT ratios, vector group and star-point earthing; zero-sequence elimination; and the Ibias calculation model your relay manufacturer uses. Then define the bias curve as inflection points, entered as bias and differential current pairs, with the slope calculated for you. The module tests it by simulating faults inside and outside the protected zone, as either shot tests at chosen points or search tests that hold Ibias fixed and search for the actual Idiff boundary.The bias curve built from inflection points. The dashed bands either side are the tolerance envelope the test points are judged against, so the curve and the pass criteria are defined in one place. 31 How do I test harmonic inrush restraint on a differential relay? The restraint curve is defined on the Harmonic tab of the differential test object — the harmonic order, the tolerance band, and inflection points entered as ratio and differential current pairs. The dedicated Harmonic Restraint module then tests it, with the same shot and search choice as the main differential test. This matters because inrush restraint is the function most likely to cause a nuisance trip in service and the least likely to have been proved at commissioning; it is a genuine gap in a lot of maintenance routines. 32 How do I test an auto-recloser with a KPM relay test kit? The Reclose module simulates the whole cycle including post-acceleration, using five states in one shot: prefault, fault, post-fault, reclosed and post-acceleration. The Ux channel simulates the line voltage, with settable amplitude, phase angle and reference channel. Binary inputs 1 to 3 take the trip commands, per phase or three-phase, and binary input 4 takes the reclose command. Results come back as three measured times — trip, reclose, and second trip. A permanent-fault option keeps the fault present after reclosing, which is what proves lockout; the module is transient by default.Five states in one shot: prefault, fault, postfault, reclosed, post-acceleration. The trip and reclose binary inputs along the bottom are what turn this into three measured times from a single injection. 33 How do I test a synchronising relay? The Synchroniser module simulates connecting a generator to the grid. One voltage group is the system side, which is the reference at zero degrees; the other is the generator side, which the software varies. Eight test functions cover it: action voltage, action frequency, angle/time, electric zero, pulse width control on frequency and on voltage, slip acceleration latch, and a full auto-synchroniser. That last one is the closed-loop test — binary inputs 5 to 8 receive the relay's own voltage and frequency raise and lower commands and the software responds to them, which is the only way to prove an automatic synchroniser genuinely works.Two voltage groups simulate the two sides of the breaker. The four binary inputs on the right catch the relay's own raise and lower commands, which is what makes a closed-loop auto-synchronizer test possible. 34 How do I test frequency and voltage protection with a KPM relay test kit? The Frequency Test module covers both. Under-frequency testing measures the frequency pickup, the operating time at a given frequency, the df/dt rate-of-change response, and the under-voltage and under-current latch behaviour. Under-voltage testing mirrors it — voltage pickup, operating time, dv/dt response and the under-current latch. The rate-of-change functions matter more than they used to: df/dt and dv/dt elements are increasingly used on networks with high renewable penetration, and they cannot be proved with a static injection. 35 What is a state sequencer, and when should I use it instead of a ramp? A state sequencer defines a series of output states and steps through them, which makes it the right tool for any time measurement — trip time above all. It offers eleven output modes, per-state binary outputs, and triggers on time, binary input, binary-plus-time, key press, or GPS/IRIG-B. It can also apply linear dv/dt, di/dt and df/dt changes within a state, plus closing angle and superimposed non-periodic components. The manual is explicit about the division of labour: the trip time shown in a ramp result is for reference only and not used for evaluation. For a trip time you intend to report, use a state sequence. 36 What is a ramping test used for on a protection KPM relay test set? Finding a threshold rather than timing an operation — pickup, drop-off, and anything derived from the two. It works as a table of ramping states, each holding one or more variables with a from value, a to value, a step and a step time. Results appear as ramp measurements, and you can enter a set value with positive and negative deviation for each so the software assesses pass or fail itself. The calculated condition feature is what makes it powerful: measure pickup in one ramp and drop-off in a second, then define the formula result 2 / result 1 and the reset ratio is evaluated automatically. 37 Can a KPM relay test kit replay a COMTRADE fault record? Yes — that is the Transplay module, and it is the fastest way to settle an argument about why a relay operated. Import the COMTRADE record and it plays back, with manual, binary or GPS triggering. Every voltage and current channel is editable and can be superimposed, channels can be combined arithmetically, outputs are scaled from primary to secondary values, and the original record is interpolated with a selectable algorithm. Sections can be repeated by start time, interval and count. One detail worth knowing: COMTRADE stores peak-to-peak values while the kit always outputs RMS, and the software handles the conversion. 38 Can a KPM relay test kit simulate a power swing? Yes. The Power Swing module models a two-terminal transmission system — generator source, line, system source — and calculates the voltage and current that would appear at the protection's location as the power angle oscillates. The angle can swing between defined start and end angles, or rotate continuously clockwise or counter-clockwise through 360°, for a set number of cycles. A fault can be superimposed on the oscillation. It is used for generator out-of-step protection and out-of-step blocking, and to check whether a system swing will cause distance or zero-sequence line protection to misoperate — which is exactly the scenario that turns a local fault into a wide-area event. 39 Can a KPM relay test kit calibrate energy meters and transducers? Yes, through two licensed optional modules. The energy meter module calibrates function and accuracy for single-phase, three-phase three-wire and three-phase four-wire meters, using the meter constant, CT and PT ratios, pulse type and count, and settling time, and it records ambient temperature and humidity into the report. It needs a photoelectric conversion sampler connected. The transducer module covers active, reactive and apparent power, frequency, AC and DC current and voltage, power factor and phase, with the characteristic defined by minimum, knee, maximum and saturation points. Both evaluate against tolerances you set. 40 How does a KPM relay test kit measure trip time? By timing from fault inception to the trip contact. The kit injects the prefault condition, then applies the fault and starts its timer at the same instant; the relay's own delay logic runs; the trip command arrives at a binary input and the timer stops. The measured time is then compared with the relay's setting to give a pass or fail. Two things govern the accuracy of that number. The binary change must last longer than the deglitch time to be recorded at all. And the prefault state must be long enough for the relay to see healthy conditions and reset — 500 ms minimum is the recommendation for shot tests.Trip time is the interval between fault inception and the trip contact changing state. The prefault state is not optional padding — the relay has to see healthy conditions long enough to reset before the fault arrives, or the measured time is meaningless. 41 How does kpm relay testing software decide whether a test passed or failed? By comparing the measured value with the value it calculated from the test object, against the tolerances you set. Tolerances are entered in two forms — relative as a percentage and absolute as a value — and the rule that matters is that the software takes the larger of the two. That is deliberate and it is the sensible behaviour: a purely relative tolerance becomes absurdly tight near zero, while a purely absolute one becomes meaningless at large values. Both current and time deviations are judged this way. Points that pass are drawn green on the characteristic, points that fail are drawn red. 42 What report formats does kpm relay testing software produce? RTF and PDF for the finished report, following a layout you configure through Report Set, which controls which data blocks appear. There is also an export function for custom report formats to suit a particular customer's requirements. Separately, results save as XML, which is a different thing and more useful than it sounds — see the next answer. Test personnel name and company name are entered once in the software settings and carried into every report, and per-module comments and a modifiable assessment conclusion can be added before the report is generated.The report preview, reachable by clicking the test object in the tree. Parameters, results, verdicts and the characteristic plot all travel into the RTF or PDF output together. 43 Can I reopen and review an old kpm relay test result? Yes, and this is the feature most worth knowing about. Results save as an XML file that can be reloaded later to view both the results and the template parameters that produced them — so a year later you can see not only what the relay did but exactly what was injected and what settings were assumed. The XML can also be used interchangeably with a .krt template, which means last year's test becomes this year's starting point. For anyone who has ever had to defend a commissioning result, this is the answer that matters. 44 What is the difference between primary and secondary value display? Which side of the CT and PT the numbers refer to. The toolbar switches the whole display between primary and secondary values, converting automatically using the ratios set in the test object. Secondary values are what the kit physically injects; primary values are what those represent out on the system. There are two more display toggles alongside it: absolute against relative, where relative values are expressed as multiples of the rated value, and seconds against cycles for the time format. All three are display conventions only — none of them changes the test. 45 What does the event recorder capture during a KPMs relay test? The changing states and the operating times of every binary input and output contact through the test. Where a result view gives you the headline number, the event recorder gives you the sequence — which contact changed, in what order, at what time. That distinction matters when a result is not what you expected: a trip that arrived on the wrong phase, a reclose that came before the trip reset, or a signal that chattered rather than operating cleanly are all visible in the event record and invisible in a single measured time. 46 What do the alarm indicators on a KPM relay test kit mean? Each turns red for a specific condition. V,H voltage amplifier overheating. V,I voltage amplifier wrongly connected to an external high-voltage source. V,S voltage output short circuit. I,H current amplifier overheating. P,B power imbalance. L,I low-level output wrongly connected to an external high-voltage source. And IA through IZ for current output open circuit, per channel. Two of these — V,I and L,I — are telling you a wiring error has connected an output to something it must never see, and warrant stopping rather than retrying. The open-circuit alarms only trigger above the detection threshold set in System Config. 47 The software says “Failed to send configuration”. What does that mean? That Apply was pressed in System Config while the kit was not connected. The configuration exists in the software but has not reached the hardware, so the kit is still running whatever it had before — which is the dangerous part, because the software will show your intended settings while the kit outputs something else. Re-establish the connection, check the status indicator reads Connected with the kit's IP address, then press Apply again and confirm it succeeds before running any test. 48 The relay operated but the test kit recorded no trip. What should I check? Work through it in this order. Is the trip contact wired to the binary input the module is actually watching, and is that input enabled in the trigger logic? Is the trigger logic set to OR when you meant OR — an AND across several inputs will not fire on one contact. Is the binary input's contact type right for the signal, potential free against threshold triggering? Is the deglitch time longer than the pulse the relay produced? And if the trigger mode is set to accept only a rising or only a falling edge, does the contact actually move in that direction? 49 How do I upgrade the firmware on a KPM relay test kit? Power up the kit and establish the connection first. Open the Upgrade window, load the new firmware package, and press Upgrade. Then leave it alone: the manual is emphatic that the power and communication connection must not be disconnected during the process. The software verifies the package against the connected model before it runs, and will refuse an incompatible version rather than attempting it — which is the protection you want, since a mismatched firmware load is the one thing that turns a test kit into a paperweight. It restarts itself when it finishes. 50 How do I add an optional module I have purchased? Through a licence certificate. The licence page shows which feature licences are currently authorised, and importing the new certificate you receive with the purchase activates the additional module. No reinstallation and no return to the factory — which means a kit bought for protection testing can be extended to energy meter or transducer calibration later, without replacing hardware. 51 How often should a KPM relay test kit be calibrated? Annual calibration against a traceable standard is the usual expectation for test and measurement equipment in utility service, and tender specifications frequently require a valid certificate at supply. The software includes a calibration function, but note the manual's restriction — it is for authorised personnel only and is not a user-accessible routine. 52 What safety precautions apply when using a KPM relay test kit? Treat it as a source, not a meter. The relay under test must be isolated from the live CT and PT circuits before anything is injected, or you are back-feeding the substation — and an open-circuited live CT is the single most dangerous thing in a protection panel. Earth the kit. Confirm the auxiliary DC level before energising a relay from it. Check where the trip output actually goes before allowing the relay to operate, because a trip signal reaching a real breaker during a test is not a theoretical risk. Normal permit-to-work and isolation practice applies throughout. 53 What support is provided with KPM relay testing software? KPM provides hands-on training at your site as part of supply, or as a separate chargeable visit, covering the modules your team uses on your own relays. Call 0124 4001088 or email sales@kpmtek.com to arrange it, or to request a demonstration.Reach us on 0124 4001088 or sales@kpmtek.com, 10 AM to 6 PM IST on working days. 54 Will you help me build my first test templates? Yes, we provide support in building templates for the relay types on your system as part of commissioning, and hands-on operator training at your site. State whether this is included in supply or chargeable, and whether it covers one location or several. ] Templates are where the time saving in this software actually lives, so getting the first few right is worth more than any amount of manual reading. 55 What if I get a test result, I do not understand? Save the XML result and send it to sales@kpmtek.com with the relay details. Because the XML carries both the results and the template parameters that produced them, our engineer can see exactly what was injected and what was assumed — which usually settles it without a site visit. This is the support customers use most. Typical response: 10 AM to 6 PM IST on working days. 56 How quickly do you respond to a support request? We support customers by telephone, email and online video meeting whenever they need it. Typical response to a test record sent for review is one to two working days.Reach us on 0124 4001088 or sales@kpmtek.com, 10 AM to 6 PM IST on working days. 57 How do I get software updates for my KPM relay test kit? Directly from us, through verified offline channels. Because the software is designed to run on an isolated PC, it does not update itself over the internet and should not be asked to — updates come as a file we supply, which is also the only route we can vouch for. 58 Do you handle calibration and repair of the KPM relay test kit? Yes. Repairs are carried out at the KPM service centre, and we arrange calibration with a traceable certificate. Contact us with the serial number and the issue, and we will confirm the turnaround before any work starts.Call first: many reported faults turn out to be a connection, a setting or a site supply problem that we can solve over the phone the same day. 59 What warranty applies to the relay test kit and its software? The relay test kit is warranted against defects in materials and workmanship for twelve months from dispatch. Within that period we repair or replace any unit that fails in normal service at no charge.Call us before opening the instrument, because opening the case voids the warranty. The warranty covers failure, not damage: physical damage, water ingress, repair or modification by others, consumables, and connecting high voltage or high current directly to the analyzer are excluded. Application support continues for as long as you own the instrument.

  • test | KPM India |test

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|test |https://kpmtek.wixsite.com/website/fr/about-1 Heading 1 Heading 2 Heading 3 Heading 4 I'm a paragraph. Click here to add your own text and edit me. It's easy. I'm a paragraph. Click here to add your own text and edit me. It's easy. Maximum ROI

  • Earth Testing Kit by KPM | Soil Resistivity & Ground Testing|Earth Testing

    Advanced earth testing kits by KPM for precise ground resistance measurement, soil resistivity testing, and electrical safety compliance. TERRE / ESSAIS AU SOL Testeur de terre - Méthode Spike Savoir plus Earth Tester (Spike Method) KPM -ET30K Earth Resistance & Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage &_cc781905-5cde-3194-bb3b- 136bad5cf58d_Tension CA. ET30K adopts the latest technology for precise 4-pole, 3 -pole and simple 2-pole measurement for earth résistance. importing FFT and AFC technology,_cc781905-5cde- 3194-bb3b-136bad5cf58d_ with a unique function of anti-interference capability and the ability to adapt to the_cc781905-5cde-3194- bb3b-136bad5cf58d_ environment, consistency of repeat testing,_cc781905-5cde-3194-bb3b -136bad5cf58d_ pour assurer une haute précision, une grande stabilité et une grande fiabilité pour des mesures prolongées Testeur de terre - Méthode de serrage Savoir plus Testeur de terre à pince (KPM-CET1200) is largement appliqué dans la mesure de la résistance au sol, boucle mesure de la résistance dans des domaines tels que l'électricité_cc781905-5cde-3194-bb3b-138d_powerelecommunications, cf5 , gisement de pétrole, architecture et équipements électriques industriels, etc. Lors de la mesure d'un système de masse avec boucle, il n'y a pas besoin de déconnecter la masse fil sans auxiliaire electrode, ce qui signifie plus sûr et plus rapide. Spécifications clés of Clamp Earth Tester (KPM-CET1200) Mesure la résistance de terre/résistance de boucle Grande taille de mâchoire (65mmx32mm) Large plage de mesure de résistance (0,01Ω à 1200Ω) Large plage de mesure de courant (0,01 A à 20 A) Idéal pour tester les circuits de fosse de terre mutuellement connectés comme Mise à la terre du réseau, mise à la terre du maillage, mise à la terre de la tour de transmission Testeur de terre - Méthode Spike Savoir plus Earth Tester (Spike Method) KPM -ET30K Earth Resistance & Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage &_cc781905-5cde-3194-bb3b- 136bad5cf58d_Tension CA. ET30K adopts the latest technology for precise 4-pole, 3 -pole and simple 2-pole measurement for earth résistance. importing FFT and AFC technology,_cc781905-5cde- 3194-bb3b-136bad5cf58d_ with a unique function of anti-interference capability and the ability to adapt to the_cc781905-5cde-3194- bb3b-136bad5cf58d_ environment, consistency of repeat testing,_cc781905-5cde-3194-bb3b -136bad5cf58d_ pour assurer une haute précision, une grande stabilité et une grande fiabilité pour des mesures prolongées Testeur de terre en ligne (GERM) Savoir plus Un appareil de pointe pour la surveillance en ligne de la santé de votre système de mise à la terre critique Grid Earth Resistance Monitor (Germ) est un état de l'appareil art qui Online surveille la valeur de résistance de terre en temps réel des puits de terre et déclenche une alarme chaque fois qu'il détecte une panne . Toutes les informations du site sont envoyées en toute sécurité au serveur via des méthodes de communication avancées. Foire aux questions (FAQ) FAQ about Earth testing : 01 Difference between Clamp and Spike Method? Earth Resistance Testing: Clamp vs. Spike Method : The Clamp Method and the Spike (Fall-of-Potential) Method are two commonly used techniques for measuring earth resistance, each with distinct use cases. The Spike Method (also known as the three-point or fall-of-potential method) is considered the most accurate and is typically used during installation or scheduled maintenance when it’s feasible to disconnect the grounding system. It requires driving two auxiliary spikes into the ground at set distances from the earth electrode and measuring the voltage drop created by a test current. This method provides a true earth resistance value but is time-consuming, invasive, and requires open ground access. In contrast, the Clamp Method (or Stakeless method) is a quick, non-intrusive test ideal for live systems where disconnecting the earth rod is not possible. Using a special clamp meter, the method induces a test signal and measures current flow through parallel earth paths. It’s convenient and fast but is only applicable when multiple grounding paths exist (e.g., in mesh or grid systems). The Clamp Method does not provide accurate results for isolated earth rods or when there is only a single grounding point. In summary, the Spike Method is best for accurate baseline testing during commissioning, while the Clamp Method is ideal for routine checks on operational systems without disrupting service. 02 How to Ensure Compliance With Earth Testing in Renewable Sites? Ensuring Compliance with Earth Testing in Renewable Sites : To ensure safety and meet regulatory standards in solar, wind, or hybrid renewable energy systems, proper earth resistance testing is essential. Key Steps: Follow Standards: Comply with IEC 60364, IEEE 80, BS 7430, or local codes. Test Soil Early: Conduct soil resistivity surveys during design to select the right grounding method. Use Proper Methods: Apply the Fall-of-Potential method for commissioning and Clamp Method for periodic checks. Keep Records: Log all test data with method, instrument, and environmental details. Test Regularly: Schedule annual or biannual resistance tests to catch degradation early. Use Remote Monitoring (if available): SCADA or sensors can track resistance levels continuously. Train Personnel: Ensure field staff know correct testing procedures and safety protocols. Third-Party Verification: For audits or large projects, use certified inspectors for compliance reporting. 03 What will be seasonal Impact on Ground Resistance Measurements? Seasonal Impact on Ground Resistance Measurements Ground resistance values can vary significantly with seasonal changes due to environmental factors affecting soil conditions: Soil Moisture: During wet seasons (rainy or winter), soil moisture increases, lowering ground resistance by improving conductivity. Conversely, dry seasons cause soil to dry out, increasing resistance. Soil Temperature: Colder temperatures can increase soil resistivity as water in soil may freeze, reducing conductivity. Warmer temperatures generally improve conductivity. Soil Composition Changes: Seasonal changes in organic matter decomposition and salt concentration may also affect soil resistivity. Vegetation and Ground Cover: Plant growth during certain seasons can affect soil moisture retention and contact with grounding electrodes. Implications Testing during different seasons may yield varying results; hence, baseline measurements should be taken in both dry and wet conditions to understand worst-case scenarios. For accurate monitoring and compliance, schedule tests consistently or adjust acceptable resistance thresholds based on seasonal variation.

  • Transformer Test Equipment by KPM | Power Transformer Testing|Transformer Testing

    KPM transformer test equipment ensures accurate, reliable, and efficient testing for power and distribution transformers in industrial applications. KIT DE TEST DE TRANSFORMATEUR FAQ Vidéo Théorie Tan Delta Testeur Voir plus KPM TD-12 est un équipement simple et robuste pour PF/DF mesures de -: Transformateurs de puissance Machines tournantes Transformateurs de courant Transformateurs de tension Câbles haute tension (HT) Systèmes d'appareillage de commutation à isolation gazeuse (GIS) KPM TD-12 avec l'aide de sa conception spéciale est capable d'effectuer des tests Tan Delta dans un environnement de sous-station hautement chargé jusqu'à 765KV. Quelques points clés Test à 10 KV/12 KV avec incrément de 0,1 KV Freq @45HZ/55HZ , 47.5HZ/52.5HZ, 55HZ/65HZ, 57.5HZ/62.5HZ, Automatic double fréquence Unité puissante de 2000VA L'instrument dispose de nombreuses mesures de protection, telles que les fluctuations de tension d'entrée, les courts-circuits de sortie, les surtensions, les surintensités et les surchauffes. KPM TD 12 avec l'aide d'accessoires optionnels est capable de tester Tan delta de -: Huile de transformateur à l'aide de Oil Test Cell Générateurs à haute capacité . N'hésitez pas à contacter pour plus de détails. Testeur IR Voir plus KPM-5KP is an easy to use 5KV IR Tester with user selectable voltage ranges 500V,1000V,2500V,5000V._cc781905-5cde- 3194-bb3b-136bad5cf58d_ Il est adapté pour mesurer l'isolation de interrupteurs, panneaux,_cc781905-5cde-3194-bb3b-136bad5cf58ct générateurs électriques, haute tension/moteurs pt, haute tension condensateurs, câbles d'alimentation, parafoudres et autres équipements de test de résistance d'isolement idéaux. Principales caractéristiques-: Installation PI/DAR Courant court <1ma Fonction de décharge automatique pour rendre l'opération sûre. Fonction « Guard » avancée pour des mesures précises Symboles d'avertissement de circuit en direct avec sons audio. Convient pour un adaptateur 12V DC (12V/1A) ou une batterie interne Testeur de rapport de tours Voir plus KPM-TTR3 est un testeur de rapport de transformateur triphasé utilisé pour mesurer le rapport de tension de 3 ou 1 transformateur de phase. Toutes les données et les résultats des tests sont affichés sur un écran LCD 320*240. Tous les résultats des tests peuvent être imprimés sur site par la micro-imprimante. KPM-TTR3 dispose d'une mémoire intégrée pour enregistrer les résultats des tests. Le circuit de réduction avancée du bruit fait du KPM-TTR3 un équipement idéal pour les conditions de terrain. Testeur de résistance d'enroulement de transformateur (1 phase) Voir plus KPM propose une gamme complète d'équipements de test de transformateur TWRT-2A (2A, test 1 phase) TWRT-10A (10A, test 1 phase) TWRT-20A (20A, test 1 phase) TWRT-40A (40A, test 1 phase) TWRT-20 ( 40A , 1 Phase Testing & 20A, 3Phase Testing ) . SFRA & Sht. CKt. Impédance Voir plus Le transformateur de puissance est un équipement électrique important, son fonctionnement sûr et fiable est extrêmement important pour les systèmes électriques. KPM SFRA+ est développé pour tester l'intégrité mécanique et électrique des transformateurs de puissance après transport ou exposition à des courants de défaut élevés. Il utilise le Principe SFRA (Sweep Frequency Response Analysis) Merde. Ckt. Méthode d'impédance & mesure la fonction de transfert électrique sur une large gamme de fréquences. Tan Delta Testeur Voir plus KPM TD-12 est un équipement simple et robuste pour PF/DF mesures de -: Transformateurs de puissance Machines tournantes Transformateurs de courant Transformateurs de tension Câbles haute tension (HT) Systèmes d'appareillage de commutation à isolation gazeuse (GIS) KPM TD-12 avec l'aide de sa conception spéciale est capable d'effectuer des tests Tan Delta dans un environnement de sous-station hautement chargé jusqu'à 765KV. Quelques points clés Test à 10 KV/12 KV avec incrément de 0,1 KV Freq @45HZ/55HZ , 47.5HZ/52.5HZ, 55HZ/65HZ, 57.5HZ/62.5HZ, Automatic double fréquence Unité puissante de 2000VA L'instrument dispose de nombreuses mesures de protection, telles que les fluctuations de tension d'entrée, les courts-circuits de sortie, les surtensions, les surintensités et les surchauffes. KPM TD 12 avec l'aide d'accessoires optionnels est capable de tester Tan delta de -: Huile de transformateur à l'aide de Oil Test Cell Générateurs à haute capacité . N'hésitez pas à contacter pour plus de détails. Testeur IR Voir plus KPM-5KP is an easy to use 5KV IR Tester with user selectable voltage ranges 500V,1000V,2500V,5000V._cc781905-5cde- 3194-bb3b-136bad5cf58d_ Il est adapté pour mesurer l'isolation de interrupteurs, panneaux,_cc781905-5cde-3194-bb3b-136bad5cf58ct générateurs électriques, haute tension/moteurs pt, haute tension condensateurs, câbles d'alimentation, parafoudres et autres équipements de test de résistance d'isolement idéaux. Principales caractéristiques-: Installation PI/DAR Courant court <1ma Fonction de décharge automatique pour rendre l'opération sûre. Fonction « Guard » avancée pour des mesures précises Symboles d'avertissement de circuit en direct avec sons audio. Convient pour un adaptateur 12V DC (12V/1A) ou une batterie interne Kit de test HUILE BDV Voir plus Comme son nom l'indique, le kit de test Oil BDV (KPM-OBD80/100+) est utilisé pour mesurer la résistance à la rupture de l'huile isolante. Capable de générer 80/100KV avec une imprimante embarquée. Agitateur motorisé et programmé Poids léger Augmentation de tension de 5 KV/sec avec plans de test automatiques selon CEI et IS 0.5KV/sec to 5KV/sec variable voltage rise as per ASTM Standards 136bad5cf58d_ modèles) SFRA & Sht. CKt. Impédance Voir plus Le transformateur de puissance est un équipement électrique important, son fonctionnement sûr et fiable est extrêmement important pour les systèmes électriques. KPM SFRA+ est développé pour tester l'intégrité mécanique et électrique des transformateurs de puissance après transport ou exposition à des courants de défaut élevés. Il utilise le Principe SFRA (Sweep Frequency Response Analysis) Merde. Ckt. Méthode d'impédance & mesure la fonction de transfert électrique sur une large gamme de fréquences. SFRA & Sht. CKt. Impédance Voir plus Le transformateur de puissance est un équipement électrique important, son fonctionnement sûr et fiable est extrêmement important pour les systèmes électriques. KPM SFRA+ est développé pour tester l'intégrité mécanique et électrique des transformateurs de puissance après transport ou exposition à des courants de défaut élevés. Il utilise le Principe SFRA (Sweep Frequency Response Analysis) Merde. Ckt. Méthode d'impédance & mesure la fonction de transfert électrique sur une large gamme de fréquences. Vidéo - Test de transformateur de puissance Video - Power Transformer Testing 765KV live switchyard ,Tan Delta Testing of Grading Capacitors Lire la vidéo CT PT Analyzer Lire la vidéo Power of 90' Rotational view , thermal imager camera Lire la vidéo 765KV live switchyard ,Tan Delta Testing of Grading Capacitors Lire la vidéo CT PT Analyzer Lire la vidéo Facebook Twitter Pinterest Tumblr Copiez le lien Lien copié Fermer Theory Power Transformer Testing Théorie - Test de transformateur de puissance Les transformateurs haute tension font partie des équipements les plus importants (et les plus coûteux) nécessaires au fonctionnement d'un système électrique. Une multitude de vérifications et de tests sont effectués au fur et à mesure que le transformateur est assemblé à la sous-station. L'ingénieur d'essai ne peut pas effectuer directement tous les tests et inspections suivants, mais doit s'assurer qu'ils sont terminés de manière satisfaisante. préparation de la banque à être dynamisée. Test IR Capacité et Tan Delta Testeur de résistance d'enroulement de transformateur Rapport de tours du transformateur Test d'équilibre magnétique du transformateur Test de courant magnétisant du transformateur Test de groupe vectoriel du transformateur Élévation de température du transformateur Test du changeur de prises SFRA - Analyseur de réponse en fréquence de balayage Test CT de douille de transformateur . Foire aux questions (FAQ) FAQ - TDK Tan delta fundamentals 01 What is tan delta testing? Insulation is never a perfect capacitor. Electrically it behaves as a capacitance with a resistance in parallel across it, and tan delta measures the ratio between the currents those two elements draw. Apply AC voltage to ideal insulation and it draws only capacitive current, leading the voltage by exactly 90°. Real insulation has a finite parallel resistance as well, so it also draws a small resistive current in phase with the voltage. The total current therefore falls short of 90° by an angle δ — the loss angle — and tan delta is simply the ratio of those two components: tanδ = IR / IC.A reading of 0.3% means the resistive current is three parts in a thousand of the capacitive current. What makes this the right quantity to measure is that it describes the material rather than the specimen: tanδ = 1/(ωRC), and for a given dielectric the product RC depends only on resistivity and permittivity, so the specimen's size and shape cancel out. As insulation absorbs moisture, becomes contaminated or ages, its parallel resistance falls while its capacitance changes very little — so the ratio rises. 02 What is the difference between tan delta, dissipation factor and power factor? They are closely related but not identical. tanδ is the tangent of the dielectric loss angle δ. Power factor is cos θ, where θ is the phase angle between voltage and current, and δ + θ = 90°. Dissipation factor is simply another name for tan delta. At the low loss values typical of healthy high-voltage insulation the two are numerically almost identical, which is why the terms get used interchangeably in the field and why most instruments display both rather than arguing the point. 03 Why measure tan delta if insulation resistance has already been tested? They answer different questions. An insulation resistance test applies DC and reports surface leakage and gross contamination, and its value depends on the size and shape of the specimen, which makes readings awkward to compare between different assets — where tan delta, being a ratio, does not. A tan delta test applies AC at or near service stress and reports on the bulk condition of the dielectric — moisture ingress, ageing of the oil-paper system, voids. A bushing or current transformer can pass an IR test comfortably and still show a tan delta trend that says it is deteriorating. In practice the two are sequential rather than alternative: an insulation test is normally carried out first, both as a condition check and as a precaution before AC test voltage is applied. 04 What does a rising tan delta value indicate? A rising value means the insulation is dissipating more energy due to resistive path than it previously did — typically from moisture ingress, contamination, ageing, or voids developing within the dielectric. Because the absolute figure depends on equipment type, design, insulation system and temperature, the useful signal is normally the trend against that asset's own history and the comparison between the three phases of the same unit, rather than the reading in isolation. A step change in capacitance measured at the same time is a stronger indicator still. 05 What does the capacitance reading tell me alongside tan delta? Capacitance is measured at the same time and reflects the geometry of the insulation rather than its quality. In a condenser-graded bushing, a step increase in capacitance indicates that one or more capacitive layers have punctured and shorted out — a failure mode tan delta alone may not flag dramatically. Catching it depends on capacitance accuracy rather than on tan delta accuracy, which is why a kit intended for bushing work needs a credible figure for both. 06 Which equipment is routinely tan delta tested? Power transformers (winding-to-winding and winding-to-earth), condenser-graded bushings, current transformers, potential transformers, capacitor voltage transformers, surge arresters, capacitors and rotating machine insulation. In a typical substation maintenance schedule, transformer bushings and instrument transformers account for most of the work, because they are the assets where a developing dielectric fault gives little other warning before it fails. 07 Is tan delta testing destructive? No. It is a diagnostic test performed at or below the equipment's normal operating stress, not a withstand test, so it does not deliberately stress insulation towards failure the way a hipot or applied-voltage test does. That is precisely what makes it suitable for routine condition monitoring — the test can be repeated on the same asset year after year to build a trend without consuming insulation life each time. 08 How does tan delta testing compare with partial discharge testing? They find different things. Tan delta reports a bulk, averaged property of the whole dielectric, so it is good at diffuse deterioration — moisture, ageing, general contamination — and poor at pinpointing a single localised defect. Partial discharge testing detects discrete discharge activity and is far better at finding a specific void or defect, but says little about overall condition. Most maintenance programmes use tan delta as the routine screening test because it is quick and repeatable, and reach for PD when a result needs investigating. 09 What test voltage does a tan delta kit need to produce? Routine testing on instrument transformers, bushings and transformer windings is commonly performed at 10 kV, with equipment rated below that tested at its own rated line-to-earth voltage. That sets the practical requirement: at least 10 kV with some headroom above it, and genuinely fine adjustment (500V min ) at the low end for lower-rated apparatus — a kit that steps in coarse increments cannot sit neatly on the rated voltage of a small CT. 10 Why does the maximum testable capacitance fall as test voltage rises in a tan delta kit? Because the current the kit must supply rises with both capacitance and voltage. The charging current of a capacitive specimen is I = 2πfCV, so doubling the test voltage doubles the current demand for the same specimen, and a portable source has a finite output. This is a power limit, not a measurement limit. It has a practical consequence when reading datasheets: a capacitance range quoted as a single headline figure tells you almost nothing, because that figure is only achievable at the lowest test voltage. The useful form is a ceiling stated at each voltage — and a large specimen is then tested at a lower voltage rather than refused. 11 What accuracy should I expect from a tan delta kit? Accuracy is normally quoted in two terms — a percentage of reading plus a fixed floor, written as ±(reading × a% + b) — and which term dominates depends entirely on what you are measuring. On healthy insulation reading a few tenths of a percent, the percentage term is tiny and the fixed floor is essentially the whole error. That makes the fixed term the number to compare between kits, and it is the one most often buried. Resolution is a separate thing and frequently confused with it: resolution is how many digits the display shows, which can easily be more digits than the instrument can justify. 12 Should the standard capacitor be built in or external of a tan delta kit? A built-in high-stability standard capacitor means routine testing needs no external reference — one less precision item to transport, calibrate and damage on site, which matters on a testing round that moves between substations. An external standard capacitor input is still worth having, because it is what allows a field accuracy check against a traceable reference and supports high-voltage measurement against an external standard. The practical answer for most field kits is built in, with the external input available when required. 13 What is a variable-frequency of a tan delta kit, and does it matter in a live substation? It is the most consequential difference between kits used in energised switchyards. Electric field from adjacent live bays couples into the test leads at power frequency and corrupts the measurement, and the higher the surrounding voltage class the worse it gets. A variable-frequency instrument measures at frequencies deliberately offset either side of mains and filters out the power-frequency component, typically measuring at both offsets and combining the results. Because the interference sits at 50 Hz and the measurement does not, the two are separable. A fixed 50 Hz kit has no mechanism to tell them apart — the interference simply becomes part of the reading, which is worse than a noisy result because it looks plausible. 14 Can one tan delta kit test transformers, bushings, CTs, PTs and CVTs? Yes. A kit with GST, UST and GSTg modes and both polarity options covers power and instrument transformers, condenser bushings, CTs, PTs and CVTs, and with an oil test cell it extends to the dielectric loss of insulating oil. The usual exception is power cable: a cable run of any length presents capacitance far beyond what a power-frequency kit can drive at test voltage, and cable dielectric loss testing is normally done with a dedicated very-low-frequency set at 0.1 Hz instead. 15 What supply does a tan delta kit need on site, and can it run from a generator? Single-phase mains, and most field instruments tolerate a stated window either side of nominal because site supply is rarely clean. Two things are worth checking before plugging in on an unfamiliar site. First, the absolute maximum input — exceeding it typically causes damage that no warranty covers, so an unstable or unregulated supply should be measured rather than assumed. Second, if the site is running on a generator, the generator's output neutral normally has to be earthed; an unearthed neutral is a common cause of an instrument refusing to start and reporting an earthing fault. 16 How portable is a tan delta kit? It depends mostly on one design decision: whether the dielectric loss bridge, the test source, the step-up transformer and the standard capacitor are integrated into a single case, or split across two or more units. An integrated kit is heavier as one item but is a single lift and a single set-up; a split design has lighter components but means a second case to carry up a gantry and additional connections to make at every test point. Ask for mass and dimensions of every item that has to reach the test position, not just the main unit. The KPM TD12 has a compact design, with an overall size comparable to a 13-inch MacBook, while weighing only approximately 24 kg.The KPM TD12 Pro is larger in size and offers a higher current capacity. It also comes with a built-in 10 kV insulation resistance (IR) tester, providing additional testing functionality in a single unit. 17 What should be supplied with a tan delta kit? As a minimum: the instrument, the matched high-voltage and low-voltage test leads, an earthing lead, a mains lead, operating instructions and a certificate of conformity, with a carrying case for the accessories. The test leads deserve more attention than they usually get — an instrument of this class is calibrated together with its supplied leads, and substituting a general-purpose cable can shift the measured result, because the cable's own characteristics become part of the measurement. Replacements should be ordered from the supplier rather than made up locally. 18 What should I ask a supplier before buying a tan delta kit? Eight questions that separate datasheets quickly.What is the capacitance ceiling at each test voltage, not just the headline range?What is the fixed term in the accuracy expression, as distinct from the resolution?Is interference rejection by variable frequency or is the kit fixed at power frequency?Are all three of GST, UST and GSTg available, and can both polarities be used?Can a CVT be tested without breaking its high-voltage connection?Is the standard capacitor internal, and can an external one be used for verification?What does the instrument refuse to do when earthing is missing or a specimen is faulty?And who answers the phone when a reading looks wrong at seven in the evening during a shutdown? 19 What is the difference between UST, GST and GSTg test modes in a tan delta kit? They differ in what the measurement includes. UST — ungrounded specimen test — measures only the insulation between two ungrounded terminals and ignores everything connected to earth. 1. Internal voltage - internal standard (CX) - straight polarity method2. Internal voltage - external standard ( CN ) - straight polarity method (must firstly set up the capacity of external standard)External voltage - internal standard (CX) - straight polarity method4. External voltage - external standard - straight polarity method (must firstly set up thecapacity of external standard CN ) GST — grounded specimen test — measures everything from the energised terminal to earth. Internal voltage - internal standard - reverse polarity methodInternal voltage - external standard - reverse polarity method (must firstly set up the capacity of external standard)External voltage - internal standard - reverse polarity methodGSTg — grounded specimen test with guard — measures to earth but diverts one current path into a guard circuit so it is excluded from the result. Running them in combination is what lets you resolve individual capacitances rather than only their sums, which is the whole reason a diagnostic set offers more than one mode.GSTg 20 What is the difference between straight and reverse polarity connection in a tan delta kit? Straight polarity — also called normal or positive — is used when the specimen’s low-voltage end is free and can be lifted from earth. Test voltage is applied at the high end, and the current is collected from the isolated low end and returned to the instrument’s measuring input. The measuring circuit therefore sits at earth potential, which is both safer and more accurate, and it is the arrangement to use wherever the specimen allows it.Internal voltage - internal standard - straight polarity methodReverse polarity is used when the low end is permanently bonded to earth and cannot be lifted — a great deal of installed apparatus is built that way. The return path then runs through earth, and the measurement has to be taken at the high-voltage end instead. Two consequences follow. The measuring connection sits at test potential, so the work demands more care. And the measurement now sees stray capacitance from the high-voltage lead to earth, which adds into the result — which is why a reverse-polarity test wants the HV lead suspended and clear of ground, and why reverse-polarity readings are generally held to be the less accurate of the two.Internal voltage - internal standard - reverse polarity methodBoth arrangements then divide again, according to where the test voltage comes from and where the reference comes from.A tan delta bridge does not measure the specimen on its own. It compares the current through the specimen against the current through a standard capacitor at the same voltage, and the result is the difference between them. With the instrument’s own source and its own built-in standard that equality is automatic, and it covers the great majority of field work. An external standard is needed in three situations:when an external high-voltage source is being used,when a traceable reference is wanted for an accuracy checkwhen the test voltage is above what the built-in standard is rated for.wo conditions attach to it. Its capacitance value must be entered into the instrument before the test, or every reading is wrong in proportion to the difference. And it must be a genuinely low-loss reference, because the standard’s own dielectric loss enters the result as an error..An external high-voltage source is needed when the test calls for more voltage than the internal source produces, or more current than it can drive into a large capacitive specimen. In that arrangement the instrument stops being the source and works purely as a bridge, and one rule governs the wiring: the external source must energise the specimen and the standard capacitor from the same point. If the two branches see different voltages the comparison is meaningless — and the reading will still look entirely plausible (Straight Polarity Method — internal or external source, against internal or external standard)(Reverse Polarity Method- internal or external source, against internal or external standard) 21 Why is the standard capacitor in tan delta kit gas-filled? Because the reference’s own loss lands directly in your answer. A tan delta bridge compares the current through the specimen against the current through a standard capacitor, and reports the difference between them. Whatever dielectric loss the standard has therefore appears in the result as an offset on every reading it is ever used for. That sets a hard requirement. Healthy insulation is being measured at a few tenths of one per cent, so the reference has to sit two or three orders of magnitude below that — loss low enough to be treated as zero. No solid dielectric can do this. Every solid insulating material has measurable loss of its own, and that loss shifts with temperature and humidity and creeps upward as the material ages — the very behaviour the instrument exists to detect. A reference built from solid dielectric would be a specimen pretending to be a standard.A gas dielectric has effectively none of it. Compressed nitrogen or SF6 has no polar structure to dissipate energy, so the loss is set by the electrode geometry rather than by a material property. Two further benefits come with it. The capacitance is fixed by the mechanical spacing of rigid electrodes rather than by a material constant, so it is stable over years rather than drifting. And compressing the gas raises its breakdown strength, which lets the electrodes be spaced for high voltage without the capacitor becoming unmanageably large.The practical consequence matters more than the physics. If you ever connect an external reference, it must be a purpose-built gas-filled standard. A power-factor-correction capacitor, a film capacitor or whatever high-voltage unit happens to be on the shelf has loss comparable to or greater than the value you are trying to measure. It will give you readings — plausible ones — that are mostly a measurement of the capacitor you substituted. KPM’s Tan Delta Kits have high quality gas filled capacitors. 22 When is an external high-voltage source or external standard capacitor needed ? An external high-voltage source is used when the test calls for a voltage above what the instrument's internal source produces. An external standard capacitor is used when measuring against a traceable external reference — for an accuracy verification, or for high-voltage measurement against an external standard. One prerequisite applies whenever an external standard is used and is a common source of wrong results: its capacitance value has to be entered into the instrument before the test is run, or every reading is out by whatever the difference happens to be. 23 How is a two-winding transformer tested by tan delta kit? With two guarded measurements that between them separate the insulation paths.GSTg ( Chg+Chl)GSTg ( Clg+Clh) For CHG + CHL, the guard is applied to the LV winding and the measurement is taken from the HV winding. For CLG + CLH, the guard is applied to the HV winding and the measurement taken from the LV winding. Adding an ungrounded measurement of the winding-to-winding capacitance lets the individual values be resolved rather than left as sums. The principle to hold on to is simple: whichever winding the guard is applied to is the winding excluded from that measurement. 24 How is a three-winding transformer tested by tan delta kit? Three-winding transformer CHG+CHL(shield of high voltage line connected to T winding)Three-winding transformer CTG+CHTLV (shield of high voltage line connected to winding)Three guarded measurements, each excluding a different winding — CHG + CHL guarding the tertiary, CLG + CLT guarding the HV winding, and CTG + CHT guarding the LV winding. The pattern is the same one as for a two-winding unit, applied three times: the guarded winding is the one taken out of the measurement. Getting the guard onto the wrong winding is the most common error in this test and produces a result that looks entirely reasonable, which is what makes it dangerous. 25 Can CVT ratio & phase be measured using the Tan delta kit instrument? On instruments that include the function, yes — dielectric loss, capacitance, ratio and phase angle can be measured in one visit with one set of connections. For CVT work this is worth more than it first appears, because it removes a separate ratio set from the kit and, more to the point, removes a second round of connecting and disconnecting at height on an asset that is awkward to reach. 26 Can the dielectric loss of insulating oil be measured with the same instrument? With an oil test cell accessory, yes. The cell holds a sample of known geometry and the instrument measures its dielectric loss directly, so oil condition and apparatus condition can be assessed with the same instrument on the same visit rather than sending samples away and waiting. 27 What record keeping does tan delta testing require? More than the test itself, because the technique is only as good as the baseline it is compared against. Each result needs the test voltage, the frequency, the mode and connection used, the specimen temperature, and the date — a reading recorded without its temperature cannot be meaningfully compared with anything measured later. On-board storage and an export route both matter for this reason: storage keeps the record at the point of test where it cannot be mislaid, and export is what gets it into a trend that survives a change of personnel. 28 Why are my tan delta readings fluctuating? Start with the connections, because that is where most cases end. The measuring lead has to land on a genuinely zero-resistance point on the specimen at both ends — a painted terminal, a loose clamp or a corroded stud is enough to make a reading wander, and the fault is invisible at a glance. Next, check that the supplied test leads are being used: an instrument of this class is calibrated with its own leads, and a substituted cable brings its own characteristics into the measurement. After that, look at shielding and earthing, then at whether interference from nearby energised equipment is reaching the test loop. 29 The Tan Delta instrument will not raise voltage and reports an earthing fault. What should be checked? Treat it as a protection working rather than a fault. Instruments of this class detect the earth connection and deliberately refuse to raise voltage without a reliable one, which is the behaviour you want. Check the earthing lead back to station earth first, and check it at both ends rather than at the instrument only. If the site is running on a generator, check the generator: an unearthed output neutral is a frequent cause of an earthing prompt and is the one operators rarely think of, because the instrument was working perfectly on mains an hour earlier. 30 Does nearby energised equipment affect the reading of Tan Delta kit? Yes, and in a working substation it is usually the dominant error source. Electric field from adjacent live bays couples into the test loop at power frequency. A variable-frequency instrument handles this by measuring away from power frequency and filtering out the coupled component, which is what makes testing practical with the rest of the yard energised. Good practice helps regardless of instrument: keep test leads off the ground and clear of live conductors, keep the high-voltage lead suspended, terminate shields properly, and keep the loop area as small as the job allows. 31 Why does the reading differ between test frequencies in a Tan delta kit? A small difference is not unusual, because dielectric loss in some insulation systems is genuinely frequency-dependent. A large divergence is a different signal: it usually means interference rejection is incomplete, and it is a prompt to check connections, shielding and earthing before the result is trusted at all. Treat a wide spread between frequencies as information about the test set-up rather than about the insulation. 32 Does tan delta need temperature correction? Tan delta is strongly temperature-dependent, so results are normally corrected to a common reference temperature before being compared against history or against an acceptance limit. Correction factors are specific to the insulation system and come from the governing standard or the equipment manufacturer — there is no single universal table, and applying the wrong one is worse than applying none. The discipline that matters is recording winding or oil temperature with every result, because an uncorrected reading with no temperature against it cannot be compared with anything measured later. 33 What tan delta value is acceptable? There is no single universal figure, and any source offering one without qualification is worth distrusting. Acceptance depends on equipment type, insulation system, voltage class, temperature, and the standard or manufacturer's test certificate governing the asset. What engineers use in practice is comparison rather than absolutes: the reading against that unit's own commissioning value, against its own trend across successive tests, and against the other two phases of the same unit. A value that has doubled from its baseline is significant even while it remains numerically small — and a value that looks high but has not moved in ten years usually is not. 34 Why would tan delta be measured at more than one voltage? Comparing results across a range of test voltages — often called a tip-up or voltage-dependence check — can reveal defects a single-voltage test does not, because some conditions only begin to dissipate significantly as electrical stress rises. A specimen that reads acceptably at low voltage and climbs steeply as voltage increases is telling you something a single reading would have hidden. Whether it forms part of a given routine depends on the asset and the maintenance standard being followed. 35 Why is my tan delta reading negative? A genuinely negative dielectric loss is not physically possible in passive insulation, so a negative reading is telling you about the measurement rather than about the specimen. The usual causes are a connection or guard error that has put a current path where the instrument does not expect one, interference from nearby energised equipment large enough to swamp a very low loss reading, or a stray path to earth on a specimen that should be isolated. Re-check the guard arrangement and the earthing before doing anything else; a negative value is one of the more useful warnings an instrument gives, because it is unambiguous. 36 Can tan delta testing be done while adjacent equipment is energised? The apparatus under test must itself be de-energised, isolated, earthed and discharged before connection — that is not negotiable. Surrounding equipment may remain energised, and in practice that is the normal condition rather than the exception, which is what makes interference rejection a practical requirement rather than a specification nicety. Normal high-voltage working practice applies throughout: permit to work, proved isolation, earthing applied and removed under control. 37 What checks are required before applying test voltage in a Tan Delta kit? Earth the instrument reliably. Confirm the specimen is isolated, earthed and discharged, then remove the earth from the specimen before testing. Carry out an insulation test on the equipment before applying AC test voltage. Establish the equipment's withstand level and choose a test voltage below it, so the test cannot spark through the specimen and damage the instrument. Confirm the site supply is inside the instrument's stated window. Keep high-voltage leads clear of personnel and check them for damage before every job — a lead that was sound last month is not evidence about today. 38 What must never be done during a Tan Delta Test? Never disconnect a test lead while voltage is applied - the discharge path may be through whoever is holding it. Never touch the high-voltage terminal or connected equipment while the instrument is raising voltage. Never exceed the stated maximum supply input. Never let a suspended high-voltage lead contact ground during a test where it is meant to be clear. And never leave a tested specimen un-earthed at the end of a test: a capacitive specimen holds charge after the source is removed, and discharging and earthing before touching anything is the last step of the test, not an afterthought. 39 How often should a tan delta kit be calibrated? Annual calibration against a traceable standard is the usual expectation for test and measurement equipment in utility service, and tender specifications frequently require a valid certificate at the point of supply. An instrument with an external standard capacitor input also allows a field accuracy check between calibrations where a traceable reference is available. 40 What protections should a tan delta kit have? Below protections are expected from a reputed Tan Delta KitEarth detection that prevents voltage being raised without a reliable earth.Over-current and short-circuit protection on the output, since a specimen can break down during a test.Over-voltage and supply-fluctuation protection on the input.Thermal protection.An emergency stop that removes the high-voltage output internally rather than merely disconnecting at a terminal, with an indicator showing whenever high voltage is live.These are what separate an instrument intended for substation work from one intended for a laboratory bench. 41 What support is provided after purchasing tan delta kit? Every instrument we supply comes with application support from the engineers who specified it, not from a call-centre script. That covers help interpreting a reading you are unsure about, guidance on the right test mode and connection for an asset you have not tested before, and support on site where the job needs it. Reach us on 0124 4001088 or support@kpmtek.com, 10 to 6PM 42 Do you help with the first test on site of tan delta kit? Yes, Online commissioning and training at the customer's site as part of supply. Each equipment supplied by KPM is backed by KPM’s support 43 What if I get a reading I do not understand on tan delta kit? Send the record to support@kpmtek.com with the asset details and the test conditions, and one of our engineers will go through it with you. This is the support customers use most — a result that looks wrong at six in the evening during a shutdown is not something to work through alone. Typical response: 1day 44 How quickly do you respond to a service request? Telephone / Whatsapp Support (Instantly / Depends on availability ), Email response within 24 working hours 45 Are spares and consumables available in tan delta kit? Yes — test leads, earthing leads, mains leads, printer consumables and fuses are generally stocked. Using the correct matched test leads affects measurement accuracy, so replacements should be ordered rather than substituted locally. 46 What warranty applies on tan delta kit? Every instrument we supply is warranted against defects in materials and workmanship for twelve months from the date of despatch. Within that period we repair or replace any unit that fails in normal service, at no charge to you. If something does go wrong, call us before opening the instrument. A good share of reported faults turn out to be a connection, a setting or a site supply problem that we can resolve over the phone the same day — and an instrument opened outside our works is no longer covered, so that call is worth making first. Where a unit genuinely needs to come in, we arrange the return and keep you posted on progress. Warranty covers failure, not damage. Physical damage, water ingress, repair or modification by anyone other than us, and consumables such as printer paper and fuses all fall outside it. One exclusion is worth knowing in advance because it is both common and entirely avoidable: supply voltage above the instrument's stated maximum causes permanent damage that no warranty covers. On a site with unstable or unregulated supply, measure before you connect.Calibration is a separate matter from warranty. A calibration certificate confirms the instrument reads correctly; the warranty covers it against failing. An instrument can be inside warranty and outside calibration, and it needs both to be worth anything on site.Support is not limited to the warranty period. Help with a connection, a test mode or a reading you are unsure about continues for as long as you own the instrument.

  • KPM EU Operations | KPM India |KPM EU Operations

    Benefiting world with INDO-EU partnerships, We are working in 1) Electrical t & m equipment 2) OEM services for Made In India electrical equipment 3) Sales & Purchase of Used / New M/Cs ( EU Origin ) all across the world . for detail visit us on http://www.kpmtek.eu MADE IN INDIA - OEM SERVICES CT , PT , Metering Cubicle , Isolators etc. TECH TIEUPS - POWER SECTOR Electrical Testing & Monitoring Solutions NEW / USED MACHINES - EU Printing M/C, Paper Converting M/C. etc. BENEFITING WORLD WITH INDO-EU_cc781905-5cde-3194-bb_SHIPNER SERVICES OEM POUR TRANSFORMATEURS D'INSTRUMENTS ( JUSQU'À 33KV ) Nous fournissons des services OEM pour les clients de la région de l'UE for transformateurs d'instruments (huile et résine coulée, jusqu'à 33 KV), isolateurs, cellules de mesure et accessoires de ligne de transmission. Tous nos produits sont fabriqués dans des installations de pointe en INDE en maintenant la qualité au plus haut niveau. Chaque équipement expédié par l'équipe KPM est testé conformément aux exigences de test d'usine CEI . Transformateur d'instrument et équipement. Mfg. - WELLMAN INDE +48 539438443 sales@kpmtek.eu CT PT OEM MACHINES D'OCCASION DE LA RÉGION UE Êtes-vous une entreprise désireuse d'acheter des machines européennes fiables d'occasion de la région de l'UE ? C'est la raison pour laquelle nous sommes le premier choix des clients comme vous ! Notre division industrielle deals dans une vaste gamme de Machines d'impression flexo et offset Machines de transformation du papier, gabarits et accessoires Machines à usage spécial. Nos consultants techniques sont stationnés en permanence dans la région de l'UE et fournissent des services de contrôle de qualité à partir de zéro pour les machines d'occasion. Nos experts surveillent le processus de démontage jusqu'à l'étape de chargement . En Inde, nous avons une équipe expérimentée pour une mise en service et un dépannage efficaces des machines fournies. Chaque machine que nous fournissons est couverte par une garantie d'un an dans la RÉGION DU SOUS-CONTINENT INDIEN Contactez-nous aujourd'hui et discutez des machines que vous recherchez ! INDIA SUPPORT PARTNER - WEBTECH, Un fabricant de haute qualité d'impression, de conversion de papier et de SPM. +48 539438443 sales@kpmtek.eu formulaire Solutions pour le secteur de l'énergie Technologie et liens d'entreprise KPM possède une vaste expérience de vente et d'application dans les équipements de test et de mesure électriques haute et basse tension. Chaque équipement fourni par KPM Engineering a fait ses preuves sur le terrain. Nos équipements de test de sous-station sont testés dans des conditions bruyantes de LIVE EHV - UHV Switchyards (Upto 765KV) Nous sommes activement ouverts aux discussions et recherchons des liens d'entreprise et techniques sur les lignes ci-dessous - : Une société de recherche et de conception avec une solution pour le secteur de l'énergie, à la recherche de liens techniques. Un utilisateur/distributeur souhaitant vendre/acheter les solutions de test et de surveillance de KPM existantes dans la région de l'UE . Investisseurs et collaborateurs +48 539438443 sales@kpmtek.eu USED MACHINES POWER SECTOR TIEUPS

  • Ultra High Voltage Test Equipment | KPM Solutions|Products

    KPM Solutions supplies precision ultra high voltage test equipment including Relay Test Kits, CT/PT Analyzers, TTR, Winding Resistance & PD Testers. Know more ÉQUIPEMENT D'ESSAI DU SYSTÈME ÉLECTRIQUE KPM VIT-100 KPM Vacuum Interrupter Tester KPM ICAL Pro KPM Instrument Calibrator KPM MT 3000 D+ Three phase Reference Standard Energy Meter specially used for energy meter on-site test KPM PSR12 KPM’s Power Signal Recorder 12 KPM TD12 A+ Automatic 12KV Capacitance & Dissipation Factor Test Set KPM TWRT YY 3 Phase Winding Resistance Tester with automatic change of connections Energy Meter Test Benchs 3 phase energy meter test bench for testing energy meters of 0.5 to 0.02 accuracy levels. KPM-SG_70kV, 70mA Cable Testing Surge Generator / Thumper KPM LBVV 240V 110A Battery Discharge Kit (Constant Current , Constant Power) KPM LB4815+ Battery Load Bank , Constant Current, Constant Power , Constant Resistance Mode KPM AL- 80H Battery Pack Air Leak Tester KPM AL- 80L KPM Battery Pack Air Leak Tester KPM CCDB + Series KPM Li Ion Cell Charge Discharge & Balancer KPM CCDB SERIES KPM Li Ion Cell Charge Discharge & Balancer KPM PDH SERIES KPM Pack Discharging (800V / 1000V) KPM PCD Series KPM li Ion Battery Pack Charge Discharge Test kit PCDH Series KPM li Ion Battery Pack Charge Discharge Test kit ( 800V / 1000V ) KPM MCD 2550 KPM charging , discharging & cyclic charging - discharging of Li Ion modules , Constant Current Discharge KPM CCDB 5V 15A KPM Li-ion Cell Charge Discharge Balancing kit, Constant Current Discharge (5V, 15 A) KPM BCD 0550 KPM Li-ion Battery Charging Discharging kit , Constant Current Discharge (5V, 50 A), Used for high current applications like forklifts, cranes etc. KPM BCD 0530 KPM Li-ion Battery Charging Discharging kit (5V, 30A), Constant Current Discharge , Used for high current applications like forklifts, cranes etc. KPM BCD B-4X KPM Li-ion Battery Charging Discharging kit with 4 independent channels (100A), Constant Current Discharge , Used for high current applications like forklifts, cranes etc. KPM KS30 KPM SF6 Gas Analyzer KPM VLF Series KPM VLF series with Tan Delta & PD Measurement Facility KPM BA-02 Battery Analyzer for testing battery internal resistance, conductance and voltage. Auto increase in the serial number of results using touch and test function, this also reduces testing time KPM Battery Data Logger To check Battery voltage, current and temperature. These sensors are integrated with battery discharge units KPM LA 103 Pro LA Tester measures and displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current directly with ambient temperature and line harmonic compensation KPM ER1 KPM ER1C is the Three phase Reference Standard Energy Meter specially used to calibrate single phase energy meter on-site . KPM AC HIPOT KPM Cable testing KPM VLF Hipot Tester KPM VLF HIGH VOLTAGE TESTER Hipot Tester KPM DC HIPOT KPM DC Hipot Test Set KPM TD 40 KPM 40kV Tan Delta measurement unit used for cable testing KPM Penta Pd pro Hand held Partial Discharge Tester with multichannel PD detection functions which can be integrated with multiple sensors like UHF , TEV, HFCT, AE , Contact Acoustic etc. KPM CEST 1800 KPM’s Clamp Earth & Spike Tester KPM CRT 6002G Contact Resistance Tester with single-end and double-end grounding test technology, It is available in 200A & 600A KPM Onload Tap Changer Analyzer Onload Tap Changer Analyzer is testing key parameters of an OLTC such as ,Transient time, Transition waveform, Transition resistance, Synchronization status of three phase. td12 Automatic 12KV Capacitance & Dissipation Factor Test Set with 4 Nos channels for Bushing testing in one test , Built In 10kV - 5mA Diagnostic Insulation Tester KPM APIK Automatic Primary Injection Kit is used for high voltage switch testing, protection system testing and current transformer testing in power system KPM CTA C+ CT Analyzer ( for factory & field applications ) KPM CT/PT Tester pro An automatic device used for testing of instrument transformers (CTs & PTs) by injection of secondary voltage. This is capable of ratio error , phase error , winding resistance, knee point upto 2kV etc. K3063i 6I & 4U - Automatic Relay Test Kit RTK(KPM KFA 300) The Lightest Relay Test Kit with 3 Current Sources & 4 voltage sources . Builtin software with AC Test , DC Test , Frequency Test , Distance Test , Harmonic Test Modules RTK(K316i) Automatic Relay Test Kit ( 6I,4U) KPM-DPM-01 KPM Dew Point Meter K68i Relay test kit 3I & 4U - Automatic Relay Test Kit RTK KPM KF 86P Automatic Relay Test Kit with 6 current and 6 voltages , with advanced software with RIO / XRIO Import function KPM CT/PT analyzer It tests all type of CT/PT as per IEC standards (deal tool for CT/PT Manufacturers & Utility Customers) KPM CT:PT Tester KPM CT PT Testing , Primary Current Method CT PT PRO KPM CT PT Tester , Voltage Ratio Method KPM CT/PT HVCTR High Voltage Current Transformer Ratio Tester measures Key CT parameters of upto 33KV system KPM CT/PT PIK For testing Current Transformer , Circuit Breakers etc. by injecting current in Primary side of CT. Moduler design for transporting easily KPM TD12 KPM 12kV Tan delta Tester / Dissipation Tester KPM TTR3 On-site measurement of DC resistance of transformer or motors (High Current Source of 20 A) KPM SFRA 01 Sweep Frequency Response Analysis Test Set (SFRA) for checking the core and winding integrity of a power transformer KPM TWRT Series On-site measurement of DC resistance of transformer (High Current Source of 20 A) KPM 5KP 5 KV Diagnostic Insulation Tester KPM 5KP+ IR Tester ( 5KV, 10KV, 15KV, 20KV) TPL-Trans Power Loss Tester KPM Transformer Power Loss Analyzer OLTC Analyzer KPM Online Tap Changer Tester KPM CB Analyzer KPM Circuit Breaker Analyzer KPM CBA 01 KPM Circuit Breaker Tester KPM CRT Contact Resistance Tester CBT-01 KPM Circuit Breaker Timer VILA KPM Vacuum Interrupter Life Analyzer KPM Oil BDV 100+ KPM Oil Breakdown Voltage Test Kit KPM Oil BDV 100 A+ KPM Oil Breakdown Voltage Test Kit with variable rate of rise voltage KPM OT-01 CC KPM Flash Point Tester Close Cup KPM OT-01 OC KPM Flash Point Tester Open cup KPM OT 02 KPM Karl Fischer Tester , Moisture in oil tester KPM OT O3 KPM Viscosity Tester KPM OT-05 KPM Oil Acid Value Tester KPM OT01 KPM Oil Tan Delta Furan Tester KPM FT-01 KPM HPLC , Furan Tester KPM IPT 01 KPM Imputiry Particle Tester KPM PCM 01 KPM Petroleum Colorimeter KPM ODT 01 KPM Oil Density Tester KPM Interfacial Tension Meter KPM Interfacial Tension Meter KPM-OPPT-01 KPM Oil Pour Point Tester KPM PDTI Monitor KPM Online Partial Discharge Monitor with Temperature & Sht. Ckt Current for HV Cable terminations KPM PDM-01 KPM Partial Discharge Monitor KPM Duo PD KPM online Partial Discharge Tester with acoustic and TEV sensors KPM PD Pulse-8 KPM Online PD Tester for PD Monitoring of switchgears and Ring Main Units KPM PDA-01 KPM Partial Discharge Analyzer , electrical method KPM Penta PD KPM Hand Held partial discharge Tester with TEV , HFCT, AE , Contact Acoustic, UHF sensors KPM CORONA POINTER KPM PD Pointer for laboratory corona finding KPM PQA+ KPM Power Quality Analyzer and recorder KPM - PQ Analyzer Light KPM Power Quality Analyzer and recorder KPM LA 100 + , LA TESTER KPM LA Tester / Surge arrester Tester / MOA Tester / 3rd harmonic leakage current tester kpm la 103+ KPM LA Tester / Surge arrester Tester / MOA Tester / 3rd harmonic leakage current tester KPM MT 3000 D 3-Phase energy meter tester KPM SF6 DPM Light KPM SF6 Dew Point Meter KPM CTTC KPM CT Heat Run Test Device KPM CEST KPM Clamp Earth Spike Tester KPM CET 1200 KPM Clamp Earth Tester KPM ET30K KPM Earth Tester with Spikes KPM GERM KPM Online Grid Earth Resistance Monitor KPM CM-0524 KPM Cell Voltage Monitor for Li Ion Batteries KPM battery load bank KPM DC Load Bank , KPM Battery Discharge Kit , KPM Constant Current DC load banks

  • EV Test Equipment Applications | KPM Engineering Sol.

    Advanced EV battery testing solutions by KPM for service centers. Ensure precise diagnostics, battery health analysis, and efficient maintenance Solutions de test du centre de service de batterie EV Test de cellule et égalisation Cliquez maintenant Maintenance haute puissance Cliquez maintenant Test de décharge HT Cliquez maintenant Module/Pack Égalisation Cliquez maintenant Anchor 1 Test de cellule et égalisation KPM BCD B-4X BCD SERIES KPM BCD B4X integrates discharge, charging and activation functions into one unit with features of multi-channel, independent cell, and large current. View More KPM BCD 0530 BCD SERIES KPM BCD 0530 can quickly and accurately maintain the cells with large voltage drops in the lithium battery module. View More KPM BCD 0550 BCD SERIES KPM BCD 0550 Series is the latest cell discharge-charge device developed by KPM , which adopts advanced battery testing technology and combines the charging and discharging characteristics of lead-acid batteries and lithium-ion batteries. View More Anchor 2 Test de cellule et égalisation KPM LI80L Testeur de fuite d'air Testeur de fuite d'air pour batteries Voir plus KPM LI80L Testeur de fuite d'air Testeur de fuite d'air pour batteries Voir plus KPM LI80L Testeur de fuite d'air Testeur de fuite d'air pour batteries Voir plus KPM LI80L Testeur de fuite d'air Testeur de fuite d'air pour batteries Voir plus Anchor 3 Mètres et autres KPM CCDB SERIES CCDB SOLUTION CCDB Series Lithium Battery Equalization Tester is developed to solve cell voltage imbalance quickly. View More CM-0524 CCDB SLOUTIONS CM - 05224 can quickly test cells voltage in the lithium battery module and judge the balance of the entire battery pack. View More KPM CCDB + Series CCDB SLOUTIONS Suitable for daily charge, discharge, and equalization maintenance of lithium-ion battery cells, module cells, and pack cells. View More KPM CCDB 5V 15A CCDB SLOUTIONS CCDB 5V 15A Lithium Battery Equalization Tester can quickly perform charge, discharge, and equalization tests on individual cells in lithium battery packs. View More Anchor 4 AIR LEAKAGE SOLUTIONS KPM-24BV Compteur de tension de cellule Li AL-80L Battery Leakage Tester is the latest high-accuracy nondestructive testing equipment developed by KPM. KPM-24BV Compteur de tension de cellule Li AL-80H is the latest high-accuracy nondestructive testing equipment developed by KPM, with the highest sensitivity and stability in the new energy industry. Foire aux questions (FAQ) FAQ about Battery Testing & EV Systems : 01 How to Test a Li-ion Battery Pack Safely and Efficiently ? Testing a Li-ion battery pack requires a balance of safety, accuracy, and efficiency. Key steps include: Visual Inspection: Check for swelling, leakage, or damaged terminals. Voltage Check: Measure open-circuit voltage to ensure cells are within the safe range. Insulation Resistance Test: Verify electrical isolation between terminals and the battery casing. Capacity & Discharge Testing: Simulate real-world loads to assess actual capacity, energy output, and discharge efficiency. Impedance/IR Testing: Identify aging cells or weak connections. Thermal Monitoring: Monitor temperature rise during charging/discharging to detect potential overheating. Safety tips include using proper PPE, short-circuit protection, and ventilated areas to avoid thermal events. KPM's Battery Pack Tester is designed for safe and efficient testing of EV and industrial Li-ion packs. It offers automated test sequences, multi-channel voltage/current monitoring, and integrated thermal protection. The tester's real-time data logging and analysis software help ensure accurate diagnostics, preventive maintenance, and safer battery operation. 02 What are the Top 5 Mistakes to Avoid While Discharging Lithium-Ion Cells ? Discharging lithium-ion cells must be done with precision to avoid safety risks and performance degradation. Here are the top 5 mistakes to avoid: 1. Over-Discharging Below Safe Voltage Limits: Going below 2.5–3.0V can cause irreversible damage or capacity loss. 2. High Current Discharge Without Monitoring: Excessive current leads to overheating, thermal runaway, or cell swelling. Always follow rated discharge current. 3. Ignoring Cell Balancing: Uneven discharge across cells in a pack can reduce lifespan or cause imbalance-related failures. 4. Lack of Temperature Monitoring: Not monitoring temperature during discharge can hide thermal issues that lead to fires or failure. 5. Discharging Without Load Control or Cut-Off Logic: Manual discharge setups without auto cut-off risk cell damage or safety hazards. KPM’s Battery Tester prevents these issues through programmable discharge profiles, auto cut-off, real-time voltage/current/temperature monitoring, and cell balancing diagnostics. It ensures safe, accurate discharge testing for EVs, storage systems, and R&D applications. 03 Why Cell Balancing is Critical in Battery Pack Design? Cell balancing is essential in lithium-ion battery pack design to ensure uniform voltage levels across all cells, which directly impacts performance, safety, and lifespan. Without balancing, even a single weak or overcharged cell can cause: Reduced usable capacity Premature degradation or failure Overheating or thermal runaway False full/empty readings during charging/discharging There are two types: 1. Passive balancing dissipates extra energy as heat and 2. Active balancing redistributes charge to weaker cells, improving efficiency KPM’s Battery Solution features integrated smart cell balancing technology. It continuously monitors each cell’s voltage and automatically adjusts charge levels to maintain uniformity. Whether in EVs, solar storage, or industrial packs, KPM’s system ensures balanced charging/discharging, enhanced cycle life, and optimal safety. The real-time monitoring interface also provides visual alerts on imbalance conditions—enabling proactive maintenance and higher reliability. 04 How AH Curve Tracers Improve Battery Quality Analysis? Ampere-Hour (AH) Curve Tracers or constant current discharge testers are critical tools for evaluating battery quality. By discharging the battery at a fixed current and recording voltage over time, they generate AH curves that reveal: 1. Actual capacity vs. rated capacity 2. Voltage stability during load 3. Internal resistance and aging behavior 4. Cut-off voltage performance 5. Cell degradation patterns over cycles This data helps manufacturers and maintenance teams identify underperforming cells, confirm batch consistency, and detect early signs of capacity fade—essential for EVs, energy storage, and critical backup systems. KPM’s Constant Current Battery Testing Equipment is designed for precise AH curve analysis. It offers programmable discharge rates, real-time voltage monitoring, and auto cut-off features. With multi-channel support and detailed data logging, it enables accurate grading, performance benchmarking, and lifecycle testing—ensuring battery packs meet safety and performance standards before deployment. 05 What do you mean by Preventing Battery Fires also what are the Role of Air Leakage Testers ? Battery fires often originate from internal short circuits, moisture ingress, or poor sealing during manufacturing. Air leakage testers play a critical role in preventing such incidents by verifying the airtightness of battery cells, modules, and packs. These testers use pressure decay, vacuum decay, or mass flow methods to detect even the smallest leaks. Ensuring proper sealing prevents oxygen or humidity from entering the cell enclosure, which can lead to electrolyte degradation, corrosion, or thermal runaway in lithium-ion batteries. Regular air leakage testing helps: Maintain IP-rated enclosures for harsh environments Detect seal defects before cell assembly Ensure consistency in automated production lines Comply with safety standards like UN38.3 and IEC 62133 KPM offers high-sensitivity air leakage testers tailored for EV and energy storage applications. With fast cycle times, digital pressure control, and data traceability, KPM’s solution enhances quality assurance and plays a vital role in fire prevention and safe battery operation. 06 What is EV Battery Diagnostics ? What are the Tools Every Service Center Must Have? As electric vehicles (EVs) grow rapidly, service centers must be equipped with specialized battery diagnostic tools to ensure safe and effective maintenance. Key tools include: Battery Pack Testers – For measuring voltage, current, capacity, and SOH (State of Health) during charge/discharge cycles. Cell Balancing Analyzers – To detect and correct imbalances between individual cells in the pack. Insulation Resistance Testers – Essential for checking insulation integrity to prevent leakage currents and electrical hazards. Thermal Imaging Devices – For identifying overheating cells or poor thermal management. Communication Interface Tools – To read battery management system (BMS) data via CAN or other protocols. Air Leakage Testers – To ensure sealed packs meet safety standards. KPM provides an integrated suite of EV battery testing equipment, including constant current testers, smart BMS diagnostic tools, cell balancers, and leakage testers. Designed for workshop and field use, KPM’s devices offer fast, accurate, and automated diagnostics, helping service centers improve safety, reduce downtime, and extend battery life. 07 Do you know Charging vs. Discharging Tests: Key Differences Explained, Advantages of each test? Charging and discharging tests are both essential for evaluating battery performance, but they serve different purposes and reveal different insights. Both tests are complementary—charging tests help optimize input energy handling, while discharging tests validate output performance. Together, they provide a comprehensive view of battery health and reliability Key Differences Feature : Charging Test Discharging Test Purpose: Assess charging efficiency & behavior Measure capacity, energy output, Stability Data Collected: Charge time, input current, voltage rise Discharge time, voltage drop, delivered AH Risks : Overcharging, thermal buildup Deep discharge, undervoltage stress Monitoring Focus: Temperature rise, end-of-charge detection Voltage sag, current stability, thermal trend Control : CC/CV (Constant Current/Voltage) Constant Current or Constant Power load Advantages of Charging Test Evaluates charging curve behavior and efficiency Helps in BMS calibration and charger compatibility Detects issues like overvoltage cutoff failure or high IR during charge Monitors thermal response during charging cycles Advantages of Discharging Test Measures real usable capacity of the battery Identifies aging or weak cells through voltage sag Simulates real-world usage conditions Critical for state of health (SOH) estimation and performance grading KPM’s battery testers support both charging and discharging modes with programmable current profiles, real-time monitoring, and data logging, enabling accurate, automated, and safe battery diagnostics across EVs, energy storage, and R&D applications. 08 What is Understanding State of Health (SOH) in Li-ion Batteries? State of Health (SOH) is a key parameter that reflects the overall condition and performance capability of a lithium-ion battery compared to its original, factory-new state. Expressed as a percentage, SOH = 100% means the battery performs at full capacity; lower values indicate degradation. Factors Affecting SOH: Capacity Fade: Reduction in charge-holding ability over cycles. Increased Internal Resistance: Leads to voltage drop and heating. Cycle Life: Number of full charge-discharge cycles completed. Temperature Stress: Accelerates degradation if outside ideal range. Charge/Discharge Rates: High currents can strain cell chemistry. How SoH is Measured: Capacity Test: Compares actual vs. rated capacity (e.g., via constant current discharge). Impedance/Resistance Test: Higher internal resistance suggests aging. Voltage Behavior Analysis: Under load, abnormal voltage drops signal poor SOH. Algorithmic Estimation: Used in BMS for real-time SOH prediction based on usage history. KPM’s battery testing equipment measures SOH using precision discharge testing, impedance analysis, and real-time voltage tracking. Its smart software computes SoH accurately, helping users assess battery viability, schedule replacements, and extend system reliability in EVs and energy storage applications. 09 Do you know Battery Test Protocols According to IEC/UN38.3 Standards ? Battery safety and performance testing follow strict protocols defined by IEC standards (e.g., IEC 62133, IEC 62660) and UN38.3, which governs the safe transport of lithium batteries. These protocols ensure batteries can withstand mechanical, electrical, and environmental stress. Key UN38.3 tests include: Altitude simulation Thermal cycling Vibration and shock resistance External short circuit Overcharge and forced discharge Impact/crush test IEC standards add protocols for electrical performance, insulation resistance, and endurance cycling. Each test is designed to validate battery integrity, prevent fire or explosion risks, and ensure global compliance for transport and use. KPM’s battery testing systems are built to comply with these standards, offering programmable test sequences, automated data logging, and safety cutoffs. This enables manufacturers and labs to efficiently validate battery packs for EVs, consumer electronics, and storage systems before certification and deployment. 10 How to Extend EV Battery Life Through Better Testing? Extending the life of an EV battery begins with smart, proactive testing practices throughout the battery’s lifecycle—from development to daily use. Key strategies include: Accurate SoH & Capacity Testing: Regularly monitor State of Health (SoH) and capacity using controlled charge/discharge cycles to detect early degradation and prevent overuse of weak cells. Cell Balancing Verification: Use testers to identify and correct imbalances, ensuring even load distribution and avoiding stress on individual cells. Thermal Profiling: Monitor temperature behavior under load to detect hotspots or cooling issues that accelerate aging. Internal Resistance Checks: Periodic impedance testing identifies cells with rising resistance—a sign of aging or failure. Simulated Real-World Load Testing: Evaluate performance under actual driving conditions to optimize BMS tuning and charging protocols. KPM’s battery testing solutions support all of the above, offering automated diagnostics, real-time analytics, and precision control. This helps EV manufacturers and service centers maximize battery life, reduce failures, and enhance long-term performance. 11 Do you know the Evolution of Battery Testing Equipment in the EV Era? With the rise of electric vehicles (EVs), battery testing equipment has evolved from basic voltage and capacity checkers to smart, multifunctional diagnostic platforms. Early systems focused on simple charge/discharge cycles, but modern EV batteries demand high-precision testing for complex parameters like State of Health (SoH), internal resistance, cell balancing, and thermal behavior. Today’s equipment supports high-voltage, multi-channel testing, fast data logging, and automated test protocols aligned with IEC and UN38.3 standards. Integration with Battery Management Systems (BMS), cloud connectivity, and AI-driven analytics are now standard, enabling predictive maintenance and lifecycle optimization. KPM’s battery testing solutions reflect this evolution by offering advanced tools for real-time monitoring, constant current testing, leakage detection, and cell balancing verification. Built for R&D, manufacturing, and service centers, KPM's systems ensure safety, accuracy, and performance—essential in the fast-paced EV ecosystem. 12 Why Your Battery Test Bench Might Be Giving False Results? False results from a battery test bench can arise due to calibration errors, inaccurate sensor placement, or improper test conditions. If the voltage or current sensors are not calibrated regularly, readings may drift, leading to incorrect capacity or SoH measurements. Poor contact resistance at terminals or cables can also distort current flow and voltage drop data. Environmental factors like temperature fluctuations or electromagnetic interference can affect sensitive measurements, especially during internal resistance or impedance tests. Additionally, incorrect test profiles—such as setting the wrong cut-off voltage or charge rate—can lead to misleading performance data. Software issues, such as outdated firmware or poor algorithm tuning, may misinterpret real-time data or fail to filter noise properly. KPM’s battery test benches mitigate these issues with auto-calibration, real-time error detection, and intelligent profiling. They ensure accurate, repeatable results that reflect the true performance and safety status of EV and energy storage batteries. 13 What are the Role of Environmental Factors in Battery Pack Testing? Environmental factors play a crucial role in battery pack testing, as they significantly influence battery performance, safety, and lifespan. Temperature, humidity, and altitude conditions can alter a battery’s behavior under both charge and discharge cycles. Temperature affects chemical reactions inside cells. High temperatures accelerate degradation and risk thermal runaway, while low temperatures reduce capacity and increase internal resistance. Humidity can lead to moisture ingress, causing corrosion or insulation breakdown—especially in poorly sealed packs. Altitude (low pressure) impacts thermal dissipation and can increase the risk of electrolyte leakage or expansion in sealed packs. To ensure reliability, batteries are tested in environmental chambers simulating real-world extremes. IEC and UN38.3 standards mandate such conditions for certification. KPM’s battery testing systems integrate seamlessly with environmental chambers, enabling precise control, real-time monitoring, and automated safety checks—ensuring comprehensive evaluation of battery packs under varied environmental stresses. 14 What is Li-ion Cell Grading: How to Do It Right? Li-ion cell grading is the process of evaluating and categorizing cells based on their performance parameters to ensure uniformity in battery pack assembly. Doing it right involves a systematic and precise testing protocol: Key Steps in Proper Cell Grading: Initial Voltage & IR Check: Measure open-circuit voltage and internal resistance to identify defective or aged cells. Capacity Testing (Constant Current Discharge):Discharge cells under a controlled current and record actual capacity (Ah) against rated values. Cycle Performance Evaluation: Charge/discharge cycles help verify stability and consistency across multiple uses. Temperature Monitoring: Track thermal response under load—abnormal heating indicates inefficiency or cell faults. Sorting Criteria: Classify cells based on capacity, IR, voltage behavior, and thermal stability into A, B, C grades. KPM’s cell grading systems offer multi-channel, high-precision testers with automated sorting, real-time data logging, and user-defined grading profiles. This ensures consistent cell performance, longer pack life, and optimal safety for EV and energy storage applications. 15 Difference between Battery Testing for Aerospace and Automotive Applications? Battery testing for aerospace and automotive applications differs significantly due to varying performance, safety, and environmental requirements. Aerospace batteries demand extreme reliability, lightweight design, and operation under harsh conditions like high altitude, vibration, and temperature extremes. Testing includes rigorous altitude simulation, thermal vacuum, and shock/vibration endurance to meet standards like RTCA DO-311 and MIL-STD. In contrast, automotive EV batteries focus on cycle life, thermal management, and high-power performance. Tests involve real-world drive simulation, fast charging analysis, thermal profiling, and compliance with UN38.3, IEC 62660, and ISO 26262. KPM’s testing solutions cater to both sectors with customizable test protocols, environmental chamber integration, and real-time monitoring. For aerospace, KPM offers high-precision, lightweight diagnostics; for automotive, it provides high-throughput, high-current testing systems—ensuring safety, efficiency, and regulatory compliance across industries. 16 End-of-Life Testing for Electric Vehicle Batteries? End-of-life (EOL) testing for electric vehicle (EV) batteries is essential to assess whether a battery can be reused, repurposed, or must be recycled. This testing focuses on determining the State of Health (SoH), remaining capacity, internal resistance, and thermal behavior after prolonged use. Key EOL testing steps include: Capacity Test: Measures actual ampere-hours (Ah) to determine if it meets minimum reuse thresholds (typically ≥70% of original). Impedance Measurement: Identifies internal degradation and cell imbalance. Charge/Discharge Cycle Analysis: Evaluates efficiency and detects abnormal voltage drops or thermal spikes. Thermal Performance Check: Assesses safety risks under load. Leakage and Insulation Tests: Ensures physical and electrical integrity. KPM’s battery EOL testing systems automate these processes with real-time monitoring, trend analysis, and safe discharge protocols. This enables accurate decision-making for second-life applications, such as stationary storage, or safe recycling, aligning with circular economy goals. 17 What do you mean by Understanding the Thermal Runaway Effect? End-of-life (EOL) testing for EV batteries is crucial to determine whether a battery should be reused, repurposed, or recycled. This involves evaluating the battery’s State of Health (SoH), residual capacity, internal resistance, and thermal behavior. Typically, a battery is considered at end-of-life when its usable capacity drops below 70–80% of its original rating. EOL testing includes controlled charge/discharge cycles, impedance analysis, and thermal profiling under simulated real-world loads. It also verifies the integrity of the Battery Management System (BMS) and checks for cell imbalance, swelling, or leakage. This testing helps classify batteries for secondary applications like energy storage or ensures safe recycling of critical materials. KPM’s battery testing systems provide automated, accurate EOL assessment with programmable protocols, multi-parameter monitoring, and safety interlocks, enabling OEMs and recyclers to make informed decisions about battery reuse, life extension, or disposal. 18 Difference between Battery Energy Density and Safety: A Testing Perspective? As energy density increases in lithium-ion batteries to meet the demands of EVs, aerospace, and portable electronics, safety risks also rise. Higher energy density means more power is stored in the same space, which can lead to thermal runaway, fire, or explosions if not properly managed. From a testing perspective, it is critical to balance performance with safety through: Thermal abuse tests to simulate overheating Overcharge/overdischarge tests to detect BMS failure scenarios Short-circuit and impact testing to assess mechanical protection Internal resistance and SoH testing to identify degradation risks early Leakage and enclosure integrity tests to prevent moisture or gas ingress Testing protocols per UN38.3, IEC 62133, and UL 2580 ensure that high-energy cells meet strict safety thresholds. KPM’s battery testing solutions are designed to test both high-capacity and high-safety requirements, providing real-time monitoring, automated safety shutdowns, and environmental stress simulations to ensure safe, high-density battery deployment. 19 What Makes a Good Battery Service Center? A good battery service center combines technical expertise, advanced diagnostic tools, and safety-first practices to ensure efficient and reliable battery maintenance. Key qualities include: Skilled Technicians trained in EV, industrial, and energy storage battery systems. Advanced Testing Equipment for SoH analysis, cell balancing, IR testing, and BMS diagnostics. Safety Protocols including insulation resistance checks, thermal monitoring, and ESD protection. Data-Driven Diagnostics using software tools for real-time monitoring and historical performance tracking. Proper Infrastructure, such as ventilated workspaces, fire suppression systems, and isolation zones for damaged packs. Support for Multiple Battery Chemistries and pack configurations.

  • Measuring Impedance | KPM India |Measuring Impedance

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Measuring Impedance |https://kpmtek.wixsite.com/website/fr/measuring-impedance Mesurer l'impédance

  • Circuit Breaker Test Kit by KPM | Electrical Testing Equipment|Circuit Breaker Testing

    Advanced circuit breaker test kits by KPM for precise timing analysis, condition monitoring, and electrical system diagnostics. KITS DE TEST DE DISJONCTEURS Vidéo Théorie Analyseur de disjoncteur Voir plus Les fonctions de Circuit Breaker Analyzer couvrent tous les éléments de test des disjoncteurs haute tension. Comparé au testeur de disjoncteur traditionnel KPM Circuit Breaker Analyzer (KPM-CBA) a les avantages uniques suivants : Analyse vibratoire des caractéristiques mécaniques Analyse de distance et de vitesse des contacts mobiles Mesure de résistance de contact statique de 100A Mesure dynamique de la résistance de contact de 100A Test de démarrage basse tension sur bobines de 16V à 300 V Testeur de résistance de contact Voir plus Testeur de résistance de contact (KPM CRT) sorties DC 600A courants pour tester la résistance de contact du disjoncteur ou des contacts de câble à courant élevé. Il est conçu selon per IEC62271. Il mesure principalement la résistance de contact du disjoncteur. Tous les test results du testeur peuvent être imprimés par la micro-imprimante intégrée dans the tester. De plus, tous les résultats de test enregistrés dans le testeur peuvent être téléchargés sur the computer puis enregistrés en tant que document MS WORD. La série KPM-CRT est disponible dans les variantes ci-dessous : 100A 200A 400A 600A KPM ABC-01 Voir plus Analyseur de disjoncteur KPM (KPM-CBA 01) est utilisé pour tester, analyser et évaluer les disjoncteurs du système d'alimentation, les caractéristiques mécaniques des commutateurs de charge et des commutateurs isolés et d'autres commutateurs haute tension CA, Contacts d'arc et caractéristiques de vibration, etc. L'analyseur de disjoncteur couvre tous exigences de test des disjoncteurs haute tension. Comparé au testeur de disjoncteurs traditionnel, l'analyseur de disjoncteurs KPM (KPM - CBA 01) présente les avantages uniques suivants : CARACTÉRISTIQUES L'ensemble de test de disjoncteur KPM CBA-01 est utilisé pour effectuer les caractéristiques électriques et mécaniques des disjoncteurs, interrupteurs et contacteurs haute tension et moyenne tension. Mesure les paramètres de temps du disjoncteur (fermé, ouvert, asynchrone, rebond) de 12 contacts principaux. Ensemble de 12 voyants d'état des contacts sur panneau. Il est facile de juger de l'état fermé et de l'état ouvert. Mesurez la course, la surcourse, le rebond, le dépassement et la vitesse du disjoncteur à l'aide d'un transducteur de résistance ou d'un transducteur numérique. Utilisez un transducteur rotatif numérique pour mesurer l'angle. Actionner les séquences de contrôle Fermer, Ouvrir, OCO, OC, CO. Testez manuellement la caractéristique mécanique actionnée par le disjoncteur. Sortie de contrôle CC intégrée, peut être utilisée pour les tests de tension d'action. Mesurez la courbe de courant du moteur pendant la conduite du moteur, mesure du courant de bobine Vacuum Interruptor Life Analyzer ( VILA )_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Voir plus KPM-VILA (analyseur de durée de vie des interrupteurs à vide) , l'ensemble de test de troisième génération utilisant sa technologie avancée pour déterminer l'état des interrupteurs à vide sur le terrain, en atelier ou en laboratoire. Si vous recherchez un test d'interrupteur à vide significatif, jetez un coup d'œil aux capacités exceptionnelles de notre nouveau VILA (analyseur de durée de vie de l'interrupteur à vide) (aka bouteille à vide testeur) qui peut être utilisé sur le terrain, en atelier ou en laboratoire. En utilisant le Penning Discharge Principal, notre VILA (analyseur de durée de vie de l'interrupteur sous vide) peut facilement identifier La pression à l'intérieur d'une ampoule à vide La durée de vie utile des ampoules à vide Jusqu'à présent, ce type de test ne pouvait être effectué qu'à l'usine d'assemblage. KPM CBT-01 (minuterie de disjoncteur) Voir plus Caractéristiques : 1. Testez les caractéristiques électriques de divers disjoncteurs haute tension. 2. Testez les paramètres de fermeture, d'ouverture, différentes périodes et le temps de rebond de 6 contacts. 3. Il y a 6 indicateurs d'état de contact sur le panneau, ce qui est pratique pour juger si l'état de fermeture ou d'ouverture ou le câblage est correct. 4. Effectuer la commande de fermeture, d'ouverture, d'ouverture et de fermeture, de fermeture, d'ouverture et de fermeture. 5. Alimentation CC réglable haute puissance intégrée, avec bouton de réglage manuel de la tension, bouton de fermeture, bouton d'ouverture, qui peut rapidement s'allumer et s'éteindre et activer le test de tension. 6. L'alimentation CC intégrée peut être utilisée pour le stockage de l'énergie du moteur. 7. Le contrôle de sortie utilise des commutateurs électroniques, avec une précision de contrôle élevée et une longue durée de vie. KPM CBT-01 (minuterie de disjoncteur) Voir plus Caractéristiques : 1. Testez les caractéristiques électriques de divers disjoncteurs haute tension. 2. Testez les paramètres de fermeture, d'ouverture, différentes périodes et le temps de rebond de 6 contacts. 3. Il y a 6 indicateurs d'état de contact sur le panneau, ce qui est pratique pour juger si l'état de fermeture ou d'ouverture ou le câblage est correct. 4. Effectuer la commande de fermeture, d'ouverture, d'ouverture et de fermeture, de fermeture, d'ouverture et de fermeture. 5. Alimentation CC réglable haute puissance intégrée, avec bouton de réglage manuel de la tension, bouton de fermeture, bouton d'ouverture, qui peut rapidement s'allumer et s'éteindre et activer le test de tension. 6. L'alimentation CC intégrée peut être utilisée pour le stockage de l'énergie du moteur. 7. Le contrôle de sortie utilise des commutateurs électroniques, avec une précision de contrôle élevée et une longue durée de vie. KPM CBT-01 (minuterie de disjoncteur) Voir plus Caractéristiques : 1. Testez les caractéristiques électriques de divers disjoncteurs haute tension. 2. Testez les paramètres de fermeture, d'ouverture, différentes périodes et le temps de rebond de 6 contacts. 3. Il y a 6 indicateurs d'état de contact sur le panneau, ce qui est pratique pour juger si l'état de fermeture ou d'ouverture ou le câblage est correct. 4. Effectuer la commande de fermeture, d'ouverture, d'ouverture et de fermeture, de fermeture, d'ouverture et de fermeture. 5. Alimentation CC réglable haute puissance intégrée, avec bouton de réglage manuel de la tension, bouton de fermeture, bouton d'ouverture, qui peut rapidement s'allumer et s'éteindre et activer le test de tension. 6. L'alimentation CC intégrée peut être utilisée pour le stockage de l'énergie du moteur. 7. Le contrôle de sortie utilise des commutateurs électroniques, avec une précision de contrôle élevée et une longue durée de vie. Comparaison - Testeurs de disjoncteurs Théorie - Test de disjoncteur Theory CB Testing Un disjoncteur est un interrupteur électrique à commande automatique conçu pour protéger un circuit électrique contre les dommages causés par une surcharge ou un court-circuit. Sa fonction de base est de détecter une condition de défaut et d'interrompre le flux de courant. Le disjoncteur reçoit la commande « Déclenchement » des relais respectifs pendant les conditions de défaut. Les paramètres suivants sont souvent testés sur un disjoncteur. Tests communs sur les disjoncteurs Heure de fermeture et heure d'ouverture Tests de mouvement (comme recommandé dans la CEI 1208) Amortissement Courants de bobine Tension de déclenchement Résistance de contact statique des contacts principaux Nouvelles méthodes de diagnostic des disjoncteurs Résistance de contact dynamique Essais de vibrations. Forme de la courbe de courant de la bobine Intégrité de la bouteille sous vide Capacité et Tan Delta du condensateur de classement Mesure du point de rosée du gaz/air SF6 Les valeurs mesurées sont comparées aux valeurs limites spécifiées par le fabricant ou aux valeurs auxquelles l'organisme de maintenance est parvenu par expérience. Dans de nombreux cas, une « empreinte digitale », consistant en différentes mesures prises lorsqu'un disjoncteur est neuf, est compilée. Cette empreinte peut ensuite être utilisée comme référence pour les mesures ultérieures. Tout changement trouvé indique clairement un changement dans l'état du disjoncteur. Théorie - Test de disjoncteur Circuit Breaker Test Kits : 01 What is a KPM's Circuit Breaker Analyzer? A KPM's circuit breaker analyzer is a portable instrument that operates a breaker on command and records exactly when and how its contacts move. It times the opening and closing of each contact, measures how the contacts travel and how fast, and records the current drawn by the trip and close coils.Together these show whether the breaker will clear a fault as fast as it was designed to. The instrument is also called a breaker timing test kit or KPM's CB analyzer. 02 Why test a circuit breaker if it already trips on command? Because tripping is not enough: a breaker must trip fast enough. Protection is designed around a total fault-clearing time, and the breaker's opening time is part of it. A breaker that opens a few milliseconds late, or with one pole lagging the others, can let a fault damage equipment that the protection scheme assumed was safe.Mechanisms wear, grease hardens and springs weaken slowly, so a breaker can look healthy for years while getting slower. A timing test catches that before a real fault does. 03 What does a KPMs circuit breaker timing test measure? The core results are opening time, closing time, the time difference between poles, and contact bounce. With a travel transducer fitted, it also measures contact travel, overtravel, rebound, and contact speed.Most circuit breaker analyzers also record trip and close coil current, and can time combined operations such as open-close and close-open, which reclosing breakers must perform.A timing test records when each pole opens after the trip command; the spread between poles is the pole discrepancy. 04 What is the difference between opening time and closing time? Opening time runs from the moment the trip coil is energised to the moment the arcing contacts separate. Closing time runs from the moment the close coil is energised to the moment the contacts touch in every pole.Both include the time the mechanism takes to release and move. Opening time matters most for fault clearing; closing time matters for reclosing and for synchronised switching. 05 What is pole discrepancy in a circuit breaker test? Pole discrepancy (also called pole spread or synchronism) is the time difference between the fastest and slowest pole in the same operation. Ideally all three poles open or close at the same instant.A large spread means one pole is lagging, which stresses the system and the breaker itself. IEC 62271-100 limits it to a fraction of a power-frequency cycle, and manufacturers usually specify a tighter value for each breaker type. 06 What is contact bounce in a circuit breaker? Contact bounce is when the contacts touch, spring apart and touch again during closing, before settling closed. A timing test shows it as a short burst of open-close transitions after the first contact.Some bounce is normal, especially in vacuum breakers. Bounce that grows over time points to mechanism wear, weak contact springs or a damping problem, and it can cause contact welding or erosion. 07 What are contact travel, overtravel and rebound? Travel is how far the moving contact moves during an operation, measured from its rest position. Overtravel is the extra distance it moves past its final position before the damper stops it. Rebound is how far it springs back after that.Comparing these with the manufacturer's values shows whether the mechanism, linkages and dampers are working correctly. A circuit breaker analyzer records them as a travel-versus-time curve.Travel curve of an opening: total travel, overtravel, rebound, and the speed zone defined by the breaker manufacturer. 08 How is circuit breaker contact speed defined? Contact speed is the average speed of the moving contact over a defined zone of its travel, usually around the point where the contacts touch or separate. Each manufacturer defines that zone for their breaker, as a distance, a time window or a pair of points on the travel curve.That is why a speed figure means little without its definition. Always set up the speed calculation exactly as the breaker manufacturer specifies before comparing results. 09 What changes when testing vacuum, SF6 and oil circuit breakers? The timing test itself is the same, but what you look for changes. Vacuum breakers have short travel, so travel and bounce measurements need care. SF6 breakers often have longer travel and higher speeds, and EHV designs may have several breaks per pole and pre-insertion resistors.Older oil breakers are slower and mechanically heavier, and their results drift more with temperature and lubrication. In every case, compare results with that breaker type's own reference values. 10 What do O, C, O-C, C-O and O-CO-CO mean in breaker testing? They are operating sequences: O is open, C is close, and CO is a close followed immediately by an open. O-C tests a reclose; C-O tests a breaker closing onto a fault and tripping straight away.O-CO-CO, with defined dead times between operations, is the rated operating sequence that IEC 62271-100 uses for auto-reclosing breakers. Testing these sequences shows whether the mechanism has enough stored energy to perform them. 11 How do you connect a KPM circuit breaker analyzer to a breaker? Timing leads connect across the main contacts of each pole, so the analyzer can see each contact open and close. Control leads connect to the trip and close coil circuits, so the analyzer can operate the breaker and record coil current. A travel transducer, if used, is fixed to the mechanism or the moving contact linkage.The breaker must be isolated and earthed according to site safety rules before any lead is connected.Concept: timing leads across each main contact, control leads to the coils, and a travel transducer on the mechanism. 12 What is a travel transducer in breaker testing? It is a sensor that converts the movement of the breaker mechanism into an electrical signal the analyzer can record. Linear transducers measure straight-line movement; rotary transducers measure the rotation of a shaft in the mechanism.With a rotary transducer, the analyzer needs a conversion factor from the manufacturer (or measured from the known total travel) to turn degrees into millimetres of contact travel. 13 What is trip coil current analysis? When the trip or close coil is energised, its current rises, dips as the armature (plunger) moves, then rises again as the armature stops, before the auxiliary contact cuts it off. The shape of this curve shows how freely the armature moves and how quickly the latch releases.A slower or distorted curve points to a sticking armature, a dry latch or low control voltage, often before the opening time itself changes. It is one of the cheapest and most useful diagnostics in breaker testing.Trip coil current signature: the dip shows the armature moving; changes in its shape reveal mechanical problems early. 14 What is the minimum operating voltage test for breaker coils? It checks that the trip and close coils still operate the breaker reliably when the station battery voltage is low. The voltage applied to the coil is reduced step by step until the breaker no longer operates, and the lowest working voltage is recorded.IEC 62271-1 sets the range of supply voltage over which releases must operate, expressed as a percentage of rated voltage. A coil that needs more voltage than before is an early warning of mechanical friction or coil trouble. 15 What is a first trip test on a circuit breaker? It is a timing test on the very first operation after a long period of service, before the breaker has been exercised. Breakers that have sat closed for months can be slow on that first trip because lubricant has stiffened.Later operations loosen the mechanism and hide the problem, so the first trip is the most honest measure of how the breaker would behave in a real fault. It needs an analyzer that can be connected with the breaker in service conditions. 16 What is dynamic contact resistance measurement? Dynamic contact resistance measurement (DCRM) injects a DC current through the breaker while it operates and records how the contact resistance changes as the contacts move. It can show wear of the arcing contacts in SF6 breakers without opening the interrupter.It is a separate measurement from timing and needs a suitable current source and fast recording. Interpreting it takes experience and good reference curves for that breaker type. 17 How is contact resistance different from a timing test? Static contact resistance is measured with the breaker closed, using a micro-ohmmeter that passes a high DC current (often 100 A or more) through the main contacts. It shows the condition of the current-carrying path.A timing test shows how the mechanism moves. The two are complementary: a breaker can time perfectly and still have high contact resistance, or the other way round. Most maintenance programmes do both. 18 Can a kpm circuit breaker analyzer test with both sides of the breaker earthed? Some analyzers can, using measurement methods that do not rely on seeing voltage across an open contact. Testing with both sides earthed is safer, because it removes the risk of induced voltage from nearby live lines.Where the analyzer cannot do this, site procedures usually allow one earth to be lifted temporarily under a permit. Always follow the site's safety rules. 19 Can a breaker timing test kit also test relays and contactors? Yes. Any device with a coil and contacts can be timed the same way: operate the coil and record when each contact changes state. Contactors, auxiliary relays and motor starters are commonly tested this way.A breaker analyzer can also time auxiliary contacts on the breaker, which interlocks and protection schemes depend on. 20 What is a normal opening time for a circuit breaker? There is no single normal figure. Opening times are typically a few tens of milliseconds, but they differ widely between voltage classes, mechanism types and manufacturers.The reference is the manufacturer's specification and the breaker's own commissioning test. A result inside the manufacturer's tolerance, and close to the breaker's own earlier results, is what you are looking for. 21 What does a slow opening or closing time indicate? Common causes are stiff or dried lubricant, worn or misadjusted linkages, a sticking coil armature or latch, weak operating springs, low control voltage, or low hydraulic or pneumatic pressure in those mechanism types.Coil current and travel curves usually point to which one. A first-trip result much slower than later operations strongly suggests lubrication. 22 What pole discrepancy is acceptable? Use the manufacturer's figure for that breaker. IEC 62271-100 sets an upper limit as a fraction of a power-frequency cycle, and manufacturers usually specify a tighter value.Breakers designed for controlled (point-on-wave) switching may operate poles at deliberately different times, so check the design before treating a spread as a fault. 23 Why do results change between tests on the same breaker? Temperature, control voltage, how long the breaker had been idle, and the number of operations just before the test all affect timing. The first operation after a long rest is often slower.For trending, test under similar conditions each time, record temperature and control voltage, and note whether the result is a first operation. 24 How do you trend circuit breaker test results over time? Keep a baseline from commissioning, then compare each test against it: opening and closing times, pole spread, bounce, travel and coil current. A steady drift is more meaningful than one reading just inside tolerance.Overlaying travel and coil current curves from successive tests is the quickest way to see what has changed. 25 How often should KPM circuit breakers be tested? At commissioning, then at intervals set by the utility's maintenance policy, the manufacturer's recommendations and the breaker's importance. Many utilities also test after a set number of operations or after interrupting heavy fault currents.Condition-based programmes test critical breakers more often and lightly loaded ones less, using the trend of earlier results to decide. 26 What safety precautions apply to KPM circuit breaker testing? Isolate the breaker, prove it dead and apply earths under the site's permit system before connecting anything. Keep everyone clear of the mechanism during operations, because it moves with great force and stored spring energy can release unexpectedly.Make sure remote and protection trip and close commands cannot reach the breaker during the test, and discharge stored energy before working on the mechanism. 27 Why must the test instrument be earthed during breaker tests? Substations have strong electric and magnetic fields, and induced voltages can appear on test leads and on the breaker itself. Earthing the instrument and following the site's earthing practice keeps those voltages from reaching the operator or damaging the instrument.Connect the instrument's earth first and remove it last. 28 What should you look for in a KPM circuit breaker analyzer? Enough timing channels for the breakers you test; travel inputs for linear and rotary transducers; coil current recording; a built-in coil supply or the ability to use station DC; and support for combined sequences such as O-CO-CO.Also check portability, how results are stored and compared over time, whether it can do first-trip testing in service conditions, and the supplier's application support in your region. 29 How many timing channels does a KPM circuit breaker analyzer need? Three channels cover a simple three-pole breaker with one break per pole. EHV breakers often have two or more breaks per pole, plus pre-insertion resistor contacts, so they need several channels per phase.Auxiliary contacts need their own channels too. Count the contacts on the largest breaker you test, then add a margin. 30 Should the analyzer supply the coil voltage or use station DC? Either works. A built-in coil supply lets you test a breaker in a workshop or with the station battery out of service, and makes minimum operating voltage tests easy. Using station DC tests the breaker exactly as it operates in service.Many engineers prefer an analyzer that can do both. 31 Who uses circuit breaker analyzers? Testing and commissioning companies use them to commission new substations. Utilities and transmission companies use them for routine maintenance. Breaker and switchgear manufacturers use them for routine tests, and large industrial plants use them to maintain their own switchyards. 32 What does a KPMs circuit breaker analyzer cost in India? The price depends on the number of channels, travel and coil current inputs, built-in coil supply and accessories. KPM quotes after a short discussion of the breakers you test.Call 0124 4001088 or email sales@kpmtek.com for a quotation. 33 Does KPM supply circuit breaker analyzers? Yes. KPM Engineering Solutions in Gurugram supplies circuit breaker analyzers across India, alongside relay test kits, CT/PT analyzers, tan delta kits and other substation test equipment.See the KPM circuit breaker analyzer or call 0124 4001088. 34 What support does KPM give with circuit breaker testing? Application support from engineers who test breakers themselves: help choosing the right configuration, on-site training, and help reading results when a breaker behaves unexpectedly.Send your results to sales@kpmtek.com or call 0124 4001088.

bottom of page