top of page

Search Results

Znaleziono 84 wyniki za pomocą pustego wyszukiwania

  • PD - HV Lab | KPM Engineering Sol.|PD - HV Lab

    Expert high voltage testing and partial discharge (PD) analysis. KPM advanced HV lab provides precise diagnostic services to ensure insulation integrity and equipment reliability. Detektor wyładowań niezupełnych NON PD Capacitive Voltage Divider_edited Non PD Capacitive Voltage Divider KPM Non PD Transformer Non PD Test Transformer Calibrator PD Calibrator Non PD Coupling Capacitor01 Non PD Coupling Capacitor Motor driven contact type voltage regular Motor driven contact Motor driven contact type voltage regula Motor driven contact type voltage regular Measuring Impedance Measuring Impedance Intermediate Transformer Intermediate transformer KPM PDA-01 Digital PD Monitor KPM PDM-01 Analog PD Monitor KPM Current Input unit High Current Input Unit

  • form page | KPM India |form page

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|form page |https://kpmtek.wixsite.com/website/pl/form-page Customer Information Contact Person: Designation and Dept. Company Name: Phone Number: Email Address: Website (if any): Location (City, Country): Machine Requirements Machine application If application is not mentioned * Make/Brand Model (Please mention "not decided" in case model is not finalised by you) Mention detailed specification and purpose of machine Expected Purchase Timeline (in months) Immediate 1–3 months 3–6 months 6 or more Expected Budget in lakhs Submit

  • Cable Testing Equipment by KPM | Fault Location & Diagnostics|CABLE

    Advanced cable testing equipment by KPM for precise fault location, insulation testing, and condition monitoring of power cables. MONITOROWANIE PD I UZIEMIENIA ONLINE KPM TAN DELTA 40 KPM TD 40 KPM TD 40 capacitance and tan delta tester is designed for condition assessment of high capacitance & high voltage electrical insulation in high voltage apparatus. It is a measurement instrument that is used with an AC power source and a standard capacitor to form a complete measurement setup. KPM TD 40 is a two-piece design. the control module and the test module communicate wirelessly during the test. KPM DC HIPOT KPM DC HIPOT KPM Portable DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM- DC series of HIPOTs is light weight, portable & easy to use. These units are user friendly & its output is stable at even high voltages DC vs AC High-potential Testing Direct current high-potential testing provides several advantages over alternating current. KPM VLF Series KPM VLF Series KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. KPM AC HIPOT KPM AC HIPTO KPM Portable AC/DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM-AC/DC series of HIPOTs is light weight , portable & easy to use. These units are user friendly& its output is stable at even high voltages it is the basic test equipment used by the power station, transmission and distribution companies for testing the insulation strength of all kind of electrical products, electrical equipment and insulated materials. KPM VLF Hipot Tester KPM VLF Hipot Tester KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. Często zadawane pytania ( FAQ ) FAQ about Cable testing : 01 1. What is VLF testing, and why is it used for cable diagnostics? VLF (Very Low Frequency) testing applies a low-frequency AC voltage—typically 0.01 Hz to 0.1 Hz—to power cables to assess their insulation condition. It’s used because VLF testing can apply a high voltage stress similar to normal operating conditions but with less heating and damage risk than standard power frequency tests. This makes it ideal for diagnosing medium- and high-voltage cables, especially in field conditions, to detect weaknesses like insulation degradation, voids, or defects before failure occurs. 02 2. How does VLF testing differ from conventional AC hipot testing? VLF testing uses a very low frequency (typically 0.01 to 0.1 Hz) AC voltage, whereas conventional AC hipot testing applies standard power frequency (50/60 Hz) voltage. The low frequency in VLF reduces the capacitive charging current in long cables, allowing high test voltages without overheating the cable insulation. This makes VLF safer and more practical for field testing of long medium- and high-voltage cables. In contrast, conventional AC hipot tests can cause excessive heating and damage when used on such cables. 03 3. What types of cable defects can VLF testing detect? VLF testing is effective at identifying a wide range of insulation defects and weaknesses within medium- and high-voltage power cables. It can detect partial discharge (PD) activity, which is a common early indicator of insulation deterioration such as microscopic voids or cracks within the cable’s insulation material. These PD sites generate localized electrical discharges that degrade the insulation over time, potentially leading to catastrophic failure if not addressed. Additionally, VLF testing can reveal water ingress problems, where moisture penetrates the insulation and lowers its dielectric strength, as well as contamination or aging effects such as thermal, mechanical, or chemical degradation of the insulation material. It can also uncover manufacturing defects like thin spots, improper curing, or insulation gaps. While VLF testing is excellent for assessing the overall integrity of the cable insulation and detecting areas of weakness, it may not precisely locate the defects. For detailed localization, it is often combined with other techniques such as partial discharge (PD) measurements or time-domain reflectometry (TDR). 04 4. What is Tan Delta (VLD) testing, and how does it assess cable insulation quality? Tan Delta (also called Very Low Dissipation factor or VLD) testing measures the dielectric losses in cable insulation by applying an AC voltage and analyzing the phase difference between the current and voltage. The "tan delta" represents the ratio of resistive (lossy) current to capacitive (ideal) current. A low tan delta value indicates good insulation with minimal energy loss, while higher values suggest deterioration due to moisture, contamination, or aging. By measuring these losses, Tan Delta testing assesses the overall insulation condition and detects early-stage degradation before catastrophic failure. It is highly sensitive to insulation quality changes and is commonly used for condition assessment and preventive maintenance of medium- and high-voltage cables. 05 5. How do Tan Delta results indicate the health or degradation of a cable? Tan Delta results reflect the insulation’s dielectric losses, which increase as the cable ages or deteriorates. A low tan delta value means the insulation is healthy, with minimal leakage current and good dielectric integrity. Conversely, a rising tan delta value indicates increasing insulation defects such as moisture ingress, contamination, cracks, or thermal aging. Trends in tan delta over time are especially important: a gradual increase suggests progressive degradation, allowing maintenance teams to plan repairs before failure occurs. Sudden spikes may point to acute damage or contamination. Thus, monitoring tan delta values helps assess the insulation’s condition, predict remaining service life, and prioritize maintenance actions. 06 6. What is VLF Partial Discharge (PD) testing, and how does it help's identify insulation defects? VLF Partial Discharge (PD) testing uses very low frequency voltage to stress the cable insulation while detecting and measuring partial discharges—tiny electrical sparks that occur within insulation voids or defects. These discharges are often early signs of insulation failure, caused by imperfections like cracks, voids, or contamination. By capturing PD activity, VLF PD testing helps pinpoint insulation defects before they lead to catastrophic cable failure. It provides valuable insight into the type, location, and severity of defects, enabling targeted maintenance and reducing unplanned outages. This makes it a crucial tool for proactive cable condition assessment. 07 7. Can VLF PD testing detect early-stage insulation failures? Yes, VLF Partial Discharge (PD) testing is specifically designed to detect early-stage insulation failures. Partial discharges are small electrical sparks that occur in microscopic voids, cracks, or impurities within the cable insulation—often long before a complete breakdown happens. By applying very low frequency voltage, VLF PD testing stresses the insulation gently but effectively, allowing detection of these early PD activities. Detecting partial discharges early helps identify weak spots or developing defects in the insulation, enabling maintenance teams to address issues proactively, extend cable life, and avoid costly unplanned failures. 08 8. What are the typical test voltages and frequencies used in VLF cable testing for 11 kV and 33 kV cables? For 11 kV cables, the VLF test voltage typically ranges from 15 kV to 33 kV, depending on the test type—diagnostic tests usually use about 1.5 times the rated voltage (around 16.5 kV), while withstand tests may apply up to 2.5 to 3 times the rated voltage (up to ~33 kV). For 33 kV cables, the test voltage typically ranges from 45 kV to 75 kV, with diagnostic tests at around 1.5 times the rated voltage (approximately 49.5 kV), and withstand tests potentially up to 2.5 times rated voltage (about 82.5 kV), though the upper limit depends on cable specifications and standards. In both cases, the frequency used is very low—typically 0.1 Hz—to reduce capacitive currents and minimize heating during testing, making it safe and effective for long cable lengths. 09 9. How do environmental factors affect VLF, Tan Delta, and PD test results? Environmental conditions like temperature, humidity, and soil moisture can significantly impact VLF, Tan Delta, and Partial Discharge (PD) test results. Temperature: Higher temperatures generally reduce insulation resistance and can increase Tan Delta values and PD activity due to increased molecular activity in the insulation. Low temperatures can raise resistance but might mask some defects. Humidity and Moisture: Moisture ingress lowers insulation resistance and increases dielectric losses, causing higher Tan Delta readings and more PD activity. Wet conditions can lead to more apparent insulation degradation during testing. Soil Conditions: For underground cables, soil resistivity and moisture affect grounding and test current paths, influencing VLF and PD measurements. Dry or rocky soils may lead to higher resistance readings. Surface Contamination: Dirt, oil, or salts on cable surfaces can cause surface discharges, impacting PD and Tan Delta results. Because of these factors, it’s important to consider and document environmental conditions during testing and, where possible, perform tests under similar conditions for consistent trending and accurate diagnostics. 10 10. What are the safety precautions and best practices during VLF and PD cable testing? Ensure Proper Training: Only qualified personnel familiar with high-voltage testing and equipment should conduct tests. Use Appropriate PPE: Wear insulated gloves, safety glasses, and flame-resistant clothing. Clear the Test Area: Establish a safe perimeter with warning signs and barriers to prevent unauthorized access during testing. Verify Equipment Condition: Check all test instruments, leads, and connections for damage before use. De-energize and Ground Cables: Ensure the cable is disconnected from the power system and properly grounded before connecting test equipment. Follow Manufacturer Guidelines: Use the recommended test voltages, durations, and procedures specific to the cable type and equipment. Monitor Test Parameters: Continuously observe voltage, current, and PD activity during the test to detect abnormalities early. Avoid Testing in Hazardous Environments: Do not perform tests during storms, wet conditions, or explosive atmospheres. Record Test Data Accurately: Document all parameters, environmental conditions, and observations for traceability and analysis. Emergency Preparedness: Have clear procedures for immediate shutdown and emergency response in case of equipment failure or personnel hazard. Following these precautions ensures safety and reliable test results while protecting both personnel and equipment.

  • Voltage Regulator (ContactType) | KPM India |Voltage Regulator (ContactType)

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Voltage Regulator (ContactType) |https://kpmtek.wixsite.com/website/pl/voltageregulator-contacttype Regulator napięcia (typ styku)

  • Meter Test Kit | KPM Engineering Sol.

    Advanced meter test kits by KPM for precise energy meter testing, calibration, and performance verification. Testowanie licznika energii Referencyjny licznik energii 3-fazowej — MT 3000D MT 3000D MT 3000D to najnowocześniejszy przenośny trójfazowy miernik energii do testowania i kalibracji liczników energii. MT3000D to łatwe w obsłudze i lekkie urządzenie. MT 3000D jest dostępny w dwóch wersjach dokładności (0,05% i 0,1%) MT3000D to wszystko w jednym urządzeniu z poniższymi funkcjami Automatyczne nieprawidłowe połączenie test Test proporcji Próba harmoniczna Test dokładności miernika (klasa 0,05/1) Wydruk raportu MT 3000B Przenośny trójfazowy miernik kWh na miejscu Kalibrator służy do kalibracji trójfazowego, jednofazowego, czynnego lub biernego licznika energii podczas pracy, a także może być używany jako miernik napięcia, prądu i mocy do pomiaru parametrów AC trójfazowej linii energetycznej , może również mierzyć współczynnik zniekształceń fali i falę harmoniczną od 2 do 63 czasu . Ma następujące cechy: • Zastosuj 32-bitowy procesor ARM, wielokanałowy 16-bitowy precyzyjny konwerter A/D, wyświetlacz TFT LCD o wysokiej rozdzielczości. •Wewnętrzny wyposażony w szerokozakresowy przekładnik prądowy 0,01% i może być wyposażony w różnego rodzaju cęgi prądowe, szeroki zakres pomiarowy i wysoką dokładność. • Projekt obwodu o niskim zużyciu energii, zasilanie bateryjne Li o wysokiej energii, oprogramowanie do zarządzania energią intelektualną, które sprawia, że instrument może pracować nieprzerwanie do 10 godzin Test licznika energii 1-fazowej, nr referencyjny Katalog EMR 1 to najnowocześniejszy przenośny jednofazowy licznik energii do testowania i kalibracji liczników energii . EMR 1 to łatwe w użyciu i lekkie urządzenie. EMR 1 ma dokładność 0,3% Specyfikacje 1. Sprawdź błędy miernika bez odłączania zasilania. 2. Opcjonalna atrapa skrzyni ładunkowej 3. Certyfikat: ISO 9001 Features Specjalna obudowa z tworzywa sztucznego, lekka i łatwa do przenoszenia, wyświetlacz LCD Zmierz napięcie, prąd, moc. fazowy współczynnik mocy bez rozłączania obwodu mocy Sprawdź dodatni/ujemny błąd miernika fazy bez odłączania obwodu zasilania Szeroki zakres cęgów prądowych: 0,5-100A Szeroki zakres napięcia roboczego: AC180 - 250V Zasilanie dostarczane bezpośrednio przez przewód testowy napięcia Wyjście impulsowe energii o wysokiej i niskiej częstotliwości. Łatwe do wysłania i przetestowania Pobieranie próbek za pomocą głowicy skanującej, bezpośrednio wprowadzany impuls miernika elektronicznego lub ręczna kalibracja przełącznika Może być podłączony do zewnętrznej skrzyni ładunkowej prądu i obsługiwać symulowane obciążenie Test licznika energii 1-fazowej, nr referencyjny Katalog EMR 1 to najnowocześniejszy przenośny jednofazowy licznik energii do testowania i kalibracji liczników energii . EMR 1 to łatwe w użyciu i lekkie urządzenie. EMR 1 ma dokładność 0,3% Specyfikacje 1. Sprawdź błędy miernika bez odłączania zasilania. 2. Opcjonalna atrapa skrzyni ładunkowej 3. Certyfikat: ISO 9001 Features Specjalna obudowa z tworzywa sztucznego, lekka i łatwa do przenoszenia, wyświetlacz LCD Zmierz napięcie, prąd, moc. fazowy współczynnik mocy bez rozłączania obwodu mocy Sprawdź dodatni/ujemny błąd miernika fazy bez odłączania obwodu zasilania Szeroki zakres cęgów prądowych: 0,5-100A Szeroki zakres napięcia roboczego: AC180 - 250V Zasilanie dostarczane bezpośrednio przez przewód testowy napięcia Wyjście impulsowe energii o wysokiej i niskiej częstotliwości. Łatwe do wysłania i przetestowania Pobieranie próbek za pomocą głowicy skanującej, bezpośrednio wprowadzany impuls miernika elektronicznego lub ręczna kalibracja przełącznika Może być podłączony do zewnętrznej skrzyni ładunkowej prądu i obsługiwać symulowane obciążenie Test licznika energii 1-fazowej, nr referencyjny Katalog EMR 1 to najnowocześniejszy przenośny jednofazowy licznik energii do testowania i kalibracji liczników energii . EMR 1 to łatwe w użyciu i lekkie urządzenie. EMR 1 ma dokładność 0,3% Specyfikacje 1. Sprawdź błędy miernika bez odłączania zasilania. 2. Opcjonalna atrapa skrzyni ładunkowej 3. Certyfikat: ISO 9001 Features Specjalna obudowa z tworzywa sztucznego, lekka i łatwa do przenoszenia, wyświetlacz LCD Zmierz napięcie, prąd, moc. fazowy współczynnik mocy bez rozłączania obwodu mocy Sprawdź dodatni/ujemny błąd miernika fazy bez odłączania obwodu zasilania Szeroki zakres cęgów prądowych: 0,5-100A Szeroki zakres napięcia roboczego: AC180 - 250V Zasilanie dostarczane bezpośrednio przez przewód testowy napięcia Wyjście impulsowe energii o wysokiej i niskiej częstotliwości. Łatwe do wysłania i przetestowania Pobieranie próbek za pomocą głowicy skanującej, bezpośrednio wprowadzany impuls miernika elektronicznego lub ręczna kalibracja przełącznika Może być podłączony do zewnętrznej skrzyni ładunkowej prądu i obsługiwać symulowane obciążenie Często zadawane pytania ( FAQ ) FAQ about Energy meter testing : 01 What is the purpose of reference testing in energy meter calibration? The purpose of reference testing in energy meter calibration is to verify and ensure the accuracy of the energy meter by comparing its measurements against a highly precise and traceable standard—called the reference meter or standard. This process identifies any measurement errors or deviations in the energy meter under test, allowing for correction or adjustment to meet specified accuracy classes. Reference testing helps maintain measurement reliability, billing fairness, and compliance with industry standards. 02 How is the accuracy class of an energy meter determined during calibration? The accuracy class of an energy meter is determined by evaluating its measurement error under a range of standardized test conditions during calibration. This involves comparing the meter’s energy readings against those of a highly accurate reference standard meter over a set period and at various load levels and power factors. The calibration process typically tests the meter at multiple points such as: Light load (e.g., 10% of rated current) Medium load (e.g., 50% of rated current) Full load (100% of rated current) Additionally, measurements are taken at different power factors, including unity (1.0), lagging (inductive), and leading (capacitive) conditions, to simulate real operating scenarios. At each test point, the percentage error is calculated by comparing the meter’s recorded energy to that of the reference meter. The accuracy class is assigned based on whether these errors stay within the maximum allowable limits defined by standards such as IEC 62053 or ANSI C12.20. For example, a Class 1.0 meter must not exceed ±1% error under these conditions. Consistent performance across all test points confirms the meter’s accuracy class, ensuring it meets the required precision for billing or monitoring applications. 03 Do you know the common standards and regulations followed for energy meter calibration? What are the common standards and regulations followed for energy meter calibration? Energy meter calibration is governed by international and regional standards to ensure accuracy, reliability, and uniformity. The most widely followed standards include: IEC 62053 series: International standards specifying performance and accuracy requirements for different classes of electricity meters (e.g., IEC 62053-21 for static meters, IEC 62053-22 for active energy meters, and IEC 62053-23 for reactive energy meters). IEC 60521 and IEC 60522: Standards covering calibration methods and testing procedures for electric meters. ANSI C12 series: North American standards, such as ANSI C12.20, that define accuracy classes and testing protocols for electric meters. OIML R46: International recommendation by the International Organization of Legal Metrology outlining accuracy requirements and test procedures for electricity meters used in billing. National regulations: Many countries have their own legal metrology regulations and certification requirements to ensure meters used for billing comply with local laws. 04 Do you know which equipment is used as a reference standard during energy meter calibration? The reference standard in energy meter calibration is a highly accurate and traceable device known as a calibration standard meter or reference meter. This equipment has a much higher precision than the meter under test, typically with an accuracy class of 0.02% or better. Common types include: Standard reference meters: Precision static energy meters designed specifically for calibration, with traceability to national or international measurement standards. Calibrated instrument transformers: High-accuracy current and voltage transformers to supply accurate test signals. Precision power sources: Devices that can generate stable and controllable voltage and current at various loads and power factors to simulate real operating conditions. Calibration benches or test rigs: Integrated setups that combine the above equipment to perform automated, controlled calibration tests. Using these reference standards ensures that the energy meter calibration is accurate, repeatable, and compliant with metrology requirements. 05 How do environmental conditions affect energy meter calibration results? Environmental factors like temperature, humidity, and atmospheric pressure can influence the accuracy of energy meter calibration. Temperature: Changes in temperature can affect the electrical characteristics of meter components, causing measurement drift or errors. Most calibration standards specify temperature ranges within which tests should be performed to ensure consistency. Humidity: High humidity can cause condensation or moisture ingress, impacting insulation resistance and electronic circuits, leading to inaccurate readings during calibration. Atmospheric pressure: Variations in pressure can subtly affect electrical properties, especially in sensitive equipment, although its impact is generally less significant than temperature or humidity. To minimize these effects, calibrations are ideally conducted in controlled laboratory environments with stable temperature and humidity, or environmental conditions are recorded and accounted for in the calibration report. 06 What is the difference between static and dynamic energy meter calibration? Static calibration tests the energy meter under steady-state conditions by applying fixed voltage and current values at set loads and power factors. It measures the meter’s accuracy when the electrical parameters remain constant, helping to verify basic performance and error under controlled, stable conditions. Dynamic calibration, on the other hand, evaluates the meter’s performance under varying, real-world operating conditions where voltage, current, and load fluctuate over time. It simulates actual usage patterns to assess how accurately the meter records energy during transient events, load changes, and power quality variations. While static calibration is simpler and faster, dynamic calibration provides a more comprehensive assessment of meter accuracy in practical scenarios, especially important for modern smart meters and complex electrical systems. 07 How often should energy meters be recalibrated to ensure accuracy? Energy meters should typically be recalibrated every 3 to 5 years, depending on regulatory requirements, manufacturer recommendations, and the operating environment. Frequent recalibration helps detect any drift in accuracy caused by aging, environmental factors, or mechanical wear. In critical applications or harsh conditions, more frequent recalibration may be necessary. Utilities often follow national standards or legal metrology guidelines that specify maximum intervals to maintain measurement reliability and billing fairness. 08 What is the process for checking the linearity of an energy meter? Checking the linearity of an energy meter involves verifying that the meter’s measurement error remains consistent across a wide range of loads. The process includes: Apply multiple test currents: The meter is tested at different load levels, typically ranging from low (e.g., 10% of rated current) to full load (100%) and sometimes even above. Maintain constant voltage and power factor: During each test point, voltage and power factor are kept steady to isolate the current’s effect. Record meter readings: The energy measured by the meter under test is compared against a reference standard meter at each load level. Calculate percentage error: For each load, the error percentage is calculated based on the difference between the test meter and reference meter readings. Analyze results: A linear meter will show minimal variation in error across all loads. Significant deviations indicate non-linearity, which can affect billing accuracy. This test ensures the meter accurately measures energy consumption regardless of load size, essential for fair billing and reliable performance. 09 How are errors in energy meters identified and corrected during calibration? During calibration, errors in energy meters are identified by comparing the meter’s recorded energy values to those of a highly accurate reference standard under controlled test conditions. The percentage difference between the meter reading and the reference reading reveals the magnitude and direction of the error. If errors exceed acceptable limits defined by standards, corrective actions may include: Adjustment: For mechanical meters, physical adjustments (like repositioning the dial or adjusting the braking magnet) can reduce errors. Reprogramming or firmware updates: For electronic meters, software recalibration or parameter tuning may correct measurement deviations. Component replacement: Faulty parts, such as sensors or electronic modules, may be replaced to restore accuracy. Rejecting the meter: If the errors cannot be corrected within tolerance, the meter may be deemed unfit for use. After correction, the meter is re-tested to confirm that errors now fall within the required accuracy class, ensuring reliable measurement and billing.

  • SF6 Gas Testing Equipment by KPM | Gas Analysis & Detection|SF6 Gas Test Equipment

    KPM SF6 gas test equipment ensures accurate measurement, reliable diagnostics, and efficient monitoring for electrical and industrial applications. GAZ SF6 (GIS) PRZYRZĄDY TESTOWE Analizator gazu SF6 Specyfikacja techniczna -: 1. Czystość SF6: 0 ~ 100% SF6 (stosunek wagowy); 2. Produkty rozkładu SF6: 1.SO2: 0 ~ 200 ppm; 2.H2S: 0 ~ 200ppm; 3.HF: 0 ~ 10 ppm; 4. CO : 0 ~ 1000ppm; 3. Dokładność pomiaru a) Czystość SF6: ± 0,1%, niezależnie od przepływu; b) Produkty rozkładu SF6: 0,1 ppm; 4) Czas reakcji a) czystość SF6: 30s; b) Produkty rozkładu SF6: 10 ~ 15s. Skontaktuj się z nami Miernik punktu rosy SF6 ( KPM DPM-01 ) Szeroko stosowany w warsztatach, biurach, zakładach, stacjach komputerowych, laboratoriach i magazynach. Ręczny miernik punktu rosy KPM-DPM-82H służy do sprawdzania punktowego i kalibracji w terenie. Zapewnia dokładny i szybki pomiar w przemysłowych zastosowaniach punktu rosy, takich jak sprężone powietrze, gaz Sf6, _cc781905 -5cde-3194-bb3b-136bad5cf58d_obróbka metali, produkcja addytywna oraz suszenie żywności i tworzyw sztucznych. Zalety-: Dokładny measurement i szybki czas pomiaru. Cyfrowy wyświetlacz zapewnia dokładny odczyt przy minimalnym błędzie Szeroki zakres pomiarowy i wysoka rozdzielczość. Ostatnie wartości / Maks. Wartości / min. wartości zarówno wilgotność, jak i temperatura zostaną automatycznie zapisane w pamięci i mogą zostać wyświetlone. Zastosowanie trwałych, trwałych komponentów, w tym mocnej, lekkiej obudowy z tworzywa ABS, zapewnia bezobsługową pracę przez wiele lat. Obudowa została starannie wyprofilowana, aby wygodnie leżała w obu dłoniach. Skontaktuj się z nami Miernik punktu rosy SF6 ( KPM DPM-01) Specyfikacja techniczna -: KPM-DPM-01 przyjmuje importowany pojemnościowy czujnik wilgotności z folii i technologię mikrokomputerową. It został opracowany jako inteligentny przyrząd do pomiaru śladów wilgoci o dobrych parametrach. Jego obsługa jest prosta i posiada funkcję konwersji między Td, RH, PPM i aktualizacją oprogramowania. Detektor może być używany do pomiaru wilgotności powietrza, w tym powietrza, azotu, gazu obojętnego i dowolnego powietrza niezawierającego środowiska korozyjnego, w szczególności do pomiaru wilgotności powietrza SF6. Cechy Samoczynna kalibracja punktu zerowego i nachylenia po uruchomieniu, kalibracja punktu rosy metodą pojedynczego punktu dla pełnego zakresu (technologia patentowa) Unikalna konstrukcja obwodu gazowego, dobra gazoszczelność i przepuszczalność, wodoodporność. Duży ekran ciekłokrystaliczny TFT wyświetla wartość punktu rosy i odpowiednią względną wilgotność względną Wartość wilgotności, wartość wilgotności PPM Przechowywanie i kwerenda danych pomiarowych Inteligentny monit o zasilanie, inteligentna ochrona ładowania Bateria litowa zapewnia długi czas czuwania zasilania Skontaktuj się z nami Często zadawane pytania ( FAQ ) FAQ about SF6 GAS testing : 01 Is SF6 Gas Testing: Health, Safety, and Environmental Implications? Sulfur hexafluoride (SF₆) is widely used as an insulating and arc-quenching gas in high-voltage switchgear due to its excellent dielectric properties. However, SF₆ is a potent greenhouse gas, with a global warming potential over 23,000 times that of CO₂. Hence, rigorous testing and handling are essential for environmental compliance and personnel safety. Key SF₆ tests include moisture content, purity, and decomposition products (like SO₂ and HF), which help detect gas leakage, contamination, or insulation failure. Exposure to decomposition byproducts can pose health hazards such as respiratory irritation or chemical burns, necessitating strict handling protocols and personal protective equipment (PPE). KPM offers advanced SF₆ gas analyzers that measure purity, moisture, and decomposition gases in accordance with IEC 60376 and 60480 standards. With portable, user-friendly designs and accurate sensors, KPM’s instruments support safe operation, environmental responsibility, and preventive maintenance of gas-insulated systems. 02 What Is a Dew Point Meter and Why Is It Essential for SF6 Systems? A dew point meter is a device that measures the dew point, the temperature at which air becomes saturated and water vapour condenses into liquid water. In SF6 (sulfur hexafluoride) systems, dew point meters are crucial for monitoring moisture levels, as even small amounts of water can lead to hydrolysis, forming corrosive byproducts like hydrofluoric acid, which damage insulation and metal components. Excess moisture can also reduce the dielectric strength of SF₆, increasing the risk of flashovers and system failures. Regular dew point monitoring ensures that SF₆ gas remains dry and stable, extending the lifespan of high-voltage equipment like GIS (Gas Insulated Switchgear). KPM's Dew Point Meters provide fast, accurate, and reliable measurements, with robust sensors designed for field and laboratory use. These meters help utilities maintain safety, reliability, and regulatory compliance, making them an essential part of preventive maintenance in SF₆ systems. 03 What is PQ analyzer , how it is different than Power recorders ? A Power Quality Analyzer and a Power Recorder may appear similar at first glance, but they serve distinct purposes in electrical diagnostics and monitoring. A Power Quality Analyzer is specifically designed to detect, analyze, and troubleshoot disturbances in the power system such as voltage sags, swells, transients, harmonics, flicker, unbalance, and frequency deviations. These analyzers are equipped with high-speed sampling capabilities, waveform capture, and harmonic spectrum analysis tools, making them ideal for identifying and resolving issues that can affect the performance or lifespan of sensitive electrical equipment. They are also commonly used for compliance monitoring against standards like EN 50160 or IEEE 519. In contrast, a Power Recorder is primarily used for long-term logging of power parameters such as voltage, current, power (kW, kVA, kVAR), and energy consumption. Its focus is more on load studies, energy audits, and identifying usage patterns over time rather than real-time disturbances or quality issues. Power Recorders usually measure and log RMS values at set intervals and are not typically equipped to detect fast transients, harmonics, or waveform-level events. While some overlap exists—many modern Power Quality Analyzers also offer recording functionality—the key difference lies in the depth of analysis. A Power Quality Analyzer is a diagnostic tool used when there’s a suspected problem or for verifying power quality compliance, whereas a Power Recorder is more of a monitoring tool for tracking energy use and system loading trends over time. 04 How Harmonics Affect Transformer Performance? Effects of Harmonics on Transformer Performance Increased Heating (Core and Copper Losses): Harmonics cause additional eddy current and hysteresis losses in the transformer core and I²R losses in the windings due to the skin effect and proximity effect. This leads to excessive heating, even when the transformer is operating within its rated current. This can reduce transformer lifespan or even cause thermal failure. Reduced Efficiency: As harmonic losses increase, the overall efficiency of the transformer drops. It may appear to be operating under normal conditions in terms of RMS values, but real power losses are higher. Derating of Transformer: To compensate for the increased losses due to harmonics, transformers are often derated (i.e., used at less than their nameplate capacity) when supplying non-linear loads. IEEE Std C57.110 provides guidelines for calculating the required derating. Increased Vibration and Noise: Harmonics can cause magnetostriction effects in the transformer core, resulting in audible noise and mechanical vibration, which can be especially problematic in sensitive environments. Insulation Stress and Aging: Repeated thermal cycling due to harmonic-induced heating stresses the insulation system, accelerating insulation degradation and reducing transformer life expectancy. Neutral Overload (in 3-phase systems): In systems with significant triplen harmonics (3rd, 9th, 15th...), these components add arithmetically in the neutral conductor. This can cause the neutral to overheat, even if the phase conductors are within limits. Incorrect Protective Relay Operation: Harmonic distortion can interfere with current and voltage sensing used in protective relays, leading to nuisance tripping or failure to trip during faults. 05 What are Real-World Applications of PQ Recorders? Real-World Applications of Power Quality (PQ) Recorders 1. Load Profiling and Energy Audits PQ recorders are commonly used to monitor energy consumption patterns over time. This helps identify peak demand periods, base loads, and inefficiencies, supporting energy optimization and cost savings. 2. Electrical System Commissioning During commissioning of new installations—such as switchboards, transformers, or generators—PQ recorders verify voltage levels, current balance, and overall system performance to ensure proper operation. 3. Capacity Planning and Expansion Before adding new electrical loads, PQ recorders assess whether existing infrastructure can support the additional demand. This prevents overloading and supports informed upgrade decisions. 4. Renewable Energy Integration In solar and wind power systems, PQ recorders monitor output stability, voltage, and frequency to ensure grid compliance and smooth integration with the main supply. 5. Troubleshooting Intermittent Issues When power issues such as flickering, nuisance tripping, or undervoltage occur, PQ recorders help log and analyze events that may not be immediately visible during spot checks. 6. Utility Billing Verification PQ recorders provide accurate data for verifying utility charges, particularly demand-based billing and power factor penalties, helping avoid disputes or overcharges. 7. Temporary Power Monitoring For construction sites, events, or mobile power setups, PQ recorders ensure temporary supplies are stable, safe, and suitable for operational requirements. 8. Preventive Maintenance and Trend Analysis Long-term monitoring enables early detection of issues like increasing unbalance or loading trends, allowing for proactive maintenance before failures occur. 06 What are the Benefits of 24/7 Power Quality Monitoring? Benefits of 24/7 Power Quality Monitoring : 1. Continuous Visibility Real-time tracking of voltage, current, harmonics, and disturbances ensures you always have a clear picture of system health — without waiting for issues to escalate. 2. Early Fault Detection Continuous monitoring helps detect developing issues like transformer overload, harmonic distortion, or voltage imbalance before they cause damage or downtime. 3. Minimizes Unplanned Downtime By identifying power disturbances early, 24/7 PQ monitoring reduces the risk of equipment failure, production loss, or service interruption. 4. Improves Equipment Lifespan Stable power quality reduces stress on motors, drives, UPS systems, and sensitive electronics — extending their service life and reducing maintenance costs. 5. Supports Root Cause Analysis Historical event logs and waveform captures make it easier to trace the cause of faults, helping engineers respond faster and more accurately. 6. Compliance & Reporting Automated recording helps meet regulatory standards (e.g., EN 50160, IEEE 519) and supports internal audits or external quality reports. 7. Energy Efficiency Optimization By continuously monitoring power factor, load balance, and harmonic content, users can implement corrective actions to reduce losses and improve system efficiency. 8. Informs Investment Decisions Reliable long-term data helps justify infrastructure upgrades, sizing of backup systems, or addition of filters and stabilizers.

  • PD Detector (Analog) | KPM India |PD Detector (Analog)

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Analog) |https://kpmtek.wixsite.com/website/pl/pd-detector-analog Detektor wyładowań niezupełnych (analogowy)

  • CT/PT Testing Kit by KPM | Current & Potential Transformer Testing|CT/PT Testing

    KPM CT/PT testing kits deliver accurate and reliable current and potential transformer testing for industrial and electrical applications. ZESTAWY DO TESTOWANIA CT I PT Analizator CT/PT CT/PT Analyzer C+ KPM-CT/PT Analyzer to kompleksowe rozwiązanie do testowania wszystkich typów CT/PT zgodnie z normami IEC. Jest to sprzęt o wysokim ROI (Return On Investment). Below features make KPM CT/PT analyzer and ideal tool for_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Producent CT/PT, laboratoria badawcze, podstacje (do 765 kV), elektrownie itp. Cechy Low Testing Time _cc781905-5cde -3194-bb3b-136bad5cf58d_ (Completes all test for CT/PT _cc781905-5cde -3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb3b- 136bad5cf58d_ _cc781905-5cde- 3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb 3b-136bad5cf58d_ _cc781905- 5cde-3194-bb3b-136bad5cf58d_ Winding & Cores in few min) Simple connection _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (proste jednorazowe połączenie) Highest Accuracy _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (0.05% for turns ratio & winding resistance ) Przenośny i lekki (<15KG) Wysoka odporność na zakłócenia (może być używana w rozdzielniach pod napięciem 220/400/765 KV ) Zestaw wtrysku prądu pierwotnego KPM APIK 2000 To urządzenie do testowania podstacji jest przeznaczone do zapewniania wysokiego prądu wyjściowego, gdy jest to potrzebne podczas uruchamiania podstacji. Seria urządzeń KPM PIK ma następujące cechy: Wysoki prąd wyjściowy do 8000 A Moc wyjściowa do 35 kVA Indywidualny projekt. Przeznaczony do pierwotnego testowania wtryskowego przekaźników zabezpieczeniowych i wyłączników automatycznych, do uruchamiania i modernizacji podstacji i sieci elektrycznej Modułowa konstrukcja ułatwiająca transport Bieg ciepła. CT/PT Pro CT/PT Pro KPM-CT/PT Pro is an automatic device used for testing of instrument transformatory metodą stosunku napięcia . CT/PT Pro jest w stanie przeprowadzić poniższe testy zarówno na CT, jak i PT 1) Turns Ratio (błąd współczynnika i błędy fazy) 2) Wykreślanie krzywej wzbudzenia 3) Rezystancja uzwojenia 4) Obciążenie wtórne CT 3) polaryzacja Dane techniczne -: Najwyższy zwrot z inwestycji z niespotykaną dotąd propozycją wartości . Łatwy w obsłudze. KPM-CT PT Pror automatycznie kończy test i generuje raport . Maksymalne napięcie wyjściowe 2000V do badania charakterystyki wzbudzenia HVCTR (tester współczynnika WN CT) CTR Tester przekładni przekładników prądowych wysokiego napięcia online (KPM-HVCTR) — Tester przekładni przekładników prądowych wysokiego napięcia Jak sama nazwa wskazuje Online HV CT Ratio Tester (KPM-HVCTR) is innowacyjny_cc781905-5cde-3194-bb3b-136bad5cf50_7 -136bad5cf58d_ parametry linii / CT systemu upto 33KV. Online HV CT Ratio Tester (KPM-HVCTR) służy do określania: Pomiar prądu pierwotnego i wtórnego Aktualny współczynnik transformacji Sekwencja faz Biegunowość Analizator CT/PT CT/PT Analyzer KPM-CT/PT Analyzer to kompleksowe rozwiązanie do testowania wszystkich typów CT/PT zgodnie z normami IEC. Jest to sprzęt o wysokim ROI (Return On Investment). Below features make KPM CT/PT analyzer and ideal tool for_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Producent CT/PT, laboratoria badawcze, podstacje (do 765 kV), elektrownie itp. Cechy Low Testing Time _cc781905-5cde -3194-bb3b-136bad5cf58d_ (Completes all test for CT/PT _cc781905-5cde -3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb3b- 136bad5cf58d_ _cc781905-5cde- 3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb 3b-136bad5cf58d_ _cc781905- 5cde-3194-bb3b-136bad5cf58d_ Winding & Cores in few min) Simple connection _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (proste jednorazowe połączenie) Highest Accuracy _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (0.05% for turns ratio & winding resistance ) Przenośny i lekki (<15KG) Wysoka odporność na zakłócenia (może być używana w rozdzielniach pod napięciem 220/400/765 KV ) Zestaw wtrysku prądu pierwotnego PIK To urządzenie do testowania podstacji jest przeznaczone do zapewniania wysokiego prądu wyjściowego, gdy jest to potrzebne podczas uruchamiania podstacji. Seria urządzeń KPM PIK ma następujące cechy: Wysoki prąd wyjściowy do 8000 A Moc wyjściowa do 35 kVA Indywidualny projekt. Przeznaczony do pierwotnego testowania wtryskowego przekaźników zabezpieczeniowych i wyłączników automatycznych, do uruchamiania i modernizacji podstacji i sieci elektrycznej Modułowa konstrukcja ułatwiająca transport Bieg ciepła. HVCTR (tester współczynnika WN CT) HVCTR Tester przekładni przekładników prądowych wysokiego napięcia online (KPM-HVCTR) — Tester przekładni przekładników prądowych wysokiego napięcia Jak sama nazwa wskazuje Online HV CT Ratio Tester (KPM-HVCTR) is innowacyjny_cc781905-5cde-3194-bb3b-136bad5cf50_7 -136bad5cf58d_ parametry linii / CT systemu upto 33KV. Online HV CT Ratio Tester (KPM-HVCTR) służy do określania: Pomiar prądu pierwotnego i wtórnego Aktualny współczynnik transformacji Sekwencja faz Biegunowość Porównanie — analizator CT PT i CT PT Pro Wideo - Analizator CT/PT CT/PT Videos KPM CT PT Testing Videos KPM CT PT Testing Videos Odtwórz Wideo Udostępnienia Cały kanał Ten film Facebook Twitter Pinterest Tumblr Skopiuj link Link skopiowany Search videos Wyszukaj film... Teraz Odtwarzane Unboxing LA Tester , KPM LA 103+ 03:45 Odtwórz Wideo Teraz Odtwarzane KPM TAN DELTA - 12 KV (https://www.kpmtek.com/tandelta) 01:27 Odtwórz Wideo Teraz Odtwarzane UNBOXING RELAY TEST KIT - KINGSINE K3063I 05:50 Odtwórz Wideo Teraz Odtwarzane Testing Tan Delta in 765kV Live Switchyard 00:43 Odtwórz Wideo Teoria - Testy CT/PT CT PT Theory CT (przekładnik prądowy) – Teoria Jak każdy inny transformator, przekładnik prądowy ma uzwojenie pierwotne, rdzeń magnetyczny i uzwojenie wtórne. Prąd przemienny płynący w uzwojeniu pierwotnym wytwarza zmienne pole magnetyczne w rdzeniu, które następnie indukuje prąd przemienny w obwodzie uzwojenia wtórnego. Podstawowym celem projektowania przekładników prądowych jest zapewnienie wydajnego sprzężenia obwodów pierwotnego i wtórnego, tak aby prąd wtórny miał dokładny związek z prądem pierwotnym. PT (Transformator Potencjalny) – Teoria Teoria transformatora napięcia lub teoria transformatora potencjału jest podobna do teorii transformatora obniżającego napięcie ogólnego przeznaczenia. Pierwotny tego transformatora jest podłączony przez fazy lub uziemienie, w zależności od wymagań. Podobnie jak transformator, służący do obniżania napięcia, transformator potencjału, tj. PT, ma dolne zwoje na uzwojeniu wtórnym. Napięcie systemowe jest przykładane do zacisków uzwojenia pierwotnego tego transformatora, a następnie proporcjonalne napięcie wtórne pojawia się na zaciskach wtórnych PT. Testy CT/PT Poniżej znajduje się lista głównych testów przeprowadzonych na CT i PT Test rezystancji izolacji Test polaryzacji Test rezystancji wtórnej/pętli Test obciążenia (test opcjonalny) Test krzywej magnesowania (test opcjonalny) Test krzywej histerezy Test współczynnika skrętu (test opcjonalny) Podstawowy test wtrysku Próba wysokiego napięcia Często zadawane pytania ( FAQ ) FAQ - CT PT Analyzer FAQ about all our CT/PT products : 01 Jakie typy przekładników prądowych można testować za pomocą analizatora KPM CT PT? Analizator KPM CT PT jest w stanie przetestować prawie wszystkie rodzaje CT i PT, w tym pomiarowe i ochronne CT. Jeśli chodzi o zastosowania, wszystkie typy przekładników prądowych stosowane w dystrybucji, przesyłaniu i wytwarzaniu energii elektrycznej mogą być testowane za pomocą analizatora KPM CT/PT Analyzer. Testerem mogą być również przekładniki prądowe do zastosowań specjalnych, takie jak CT pierścienia szynowego, CT tulei transformatora. KPM CT PT Analyzer może testować PT i CVT również przy użyciu akcesorium wzmacniającego napięcie . 02 Czy KPM CT PT Analyzer może testować przekładniki prądowe kanałów szynowych generatora? Tak Analizator KPM CT PT może perfekcyjnie testować przekładniki prądowe generatora szyny kanałowej. 03 Czy KPM CT PT Analyzer może testować przekładniki prądowe przepustów transformatora mocy ? Tak, KPM CT PT Analyzer testuje przekładniki prądowe przepustowe transformatora mocy z perfekcją . 04 Dlaczego testowanie CT przepustu transformatora mocy jest złożoną sprawą dla każdego sprzętu do testowania CT? Analizator KPM CT PT działa na zasadzie metody stosunku napięć. Podczas testowania przekładnika prądowego transformatora mocy obwód pierwotny jest połączony szeregowo z uzwojeniem transformatora mocy, co sprawia, że testowanie jest skomplikowane. Analizator KPM CT PT za pomocą obwodów redukcji szumów jest w stanie perfekcyjnie przetestować przekładniki prądowe przepustowe transformatora mocy. 05 Jaki jest najwyższy punkt kolana badany przez KPM CT PT Analyzer . KPM CT PT Analyzer nasyca rdzeń CT z wysokim punktem przegięcia, stosując zasadę redukcji częstotliwości. Tak więc praktycznie może testować punkt kolanowy wszystkich typów przekładników prądowych ochrony EHV za pomocą źródła niskiego napięcia. Teoretycznie może przetestować punkt kolanowy nawet 35 kV. 06 Czy analizator KPM CT PT jest przenośny? Analizator KPM CT PT jest bardzo przenośny dzięki rozmiarowi (szer. x wys. x gł.) w mm 485 x 356 x 183 i wadze < 15 kg. To sprawia, że jest to idealny sprzęt do podróżowania. 07 Którzy klienci z sektora energetycznego używają analizatora KPM CT PT KPM CT PT Analyzer jest używany przez wszystkich klientów, którzy zajmują się wytwarzaniem, przesyłem oraz dystrybucją energii. 08 Czy możemy zmierzyć rezystancję pierwotną i wtórną PT za pomocą analizatora KPM CT PT Rezystancja uzwojenia pierwotnego PT jest wyrażona w kohmach. KPM CT PT Analyzer posiada zakres rezystancji w Kohmach, za pomocą którego w łatwy sposób można sprawdzić rezystancję pierwotną PT. Rezystancja wtórna PT jest wyrażona w omach, co można łatwo sprawdzić. 09 Czy możemy uzyskać krzywą histerezy CT za pomocą analizatora KPM CT PT Tak Analizator KPM CT PT ma funkcję krzywej histerezy. Pod koniec testu obliczana jest krzywa histerezy przekładnika prądowego, która wyraźnie pokazuje charakterystykę utraty mocy testowanego przekładnika prądowego. 10 Co to jest krzywa histerezy i jakie jest jej znaczenie Namagnesowanie substancji ferromagnetycznych spowodowane zmiennym polem magnetycznym pozostaje w tyle za polem. Efekt ten nazywa się histerezą, a termin ten jest używany do opisania każdego systemu, którego reakcja zależy nie tylko od jego obecnego stanu, ale także od jego przeszłej historii. W KPM CT PT Analyzer obliczana jest krzywa histerezy przekładnika prądowego. Szerokość krzywej histerezy wyraźnie pokazuje charakterystykę strat mocy badanego przekładnika prądowego. 11 W jaki sposób analizator KPM CT PT może automatycznie znaleźć wartość rezystancji uzwojenia przy 75°C. Analizator KPM CT PT posiada wbudowany czujnik temperatury, za pomocą którego mierzy temperaturę pokojową w czasie pomiaru rezystancji uzwojeń. Po zakończeniu pomiaru pokazuje wartość rezystancji uzwojenia w temperaturze pokojowej oraz skompensowaną temperaturę rezystancji uzwojenia wartość @ 75'C automatycznie. Zmniejsza to ryzyko błędu ludzkiego związanego z ręcznym wprowadzaniem danych o temperaturze . 12 Co to jest test obciążenia wtórnego CT i jakie jest jego znaczenie Wszystkie typy CT i PT są zaprojektowane do stałego obciążenia obciążenia do obsługi. Jeśli podłączone obciążenie przekładnika prądowego jest większe niż wymagane obciążenie, wówczas wyjście przekładnika prądowego nie będzie zgodne ze specyfikacją i zostanie wprowadzony błąd. Analizator KPM CT PT ma funkcję testowania obciążenia, w której analizator KPM CT PT znajduje VA całej pętli przewodnika. 13 Jakie badanie można przeprowadzić za pomocą analizatora KPM CT PT? Poniższy test można przeprowadzić na CT i PT przy użyciu analizatora KPM CT / PT Testy przekładnika prądowego: Test krzywej wzbudzenia i parametrów Test współczynnika obrotów Test współczynnika i błędu fazy Sprawdzanie oznaczenia biegunowości Pomiar rezystancji cewki Pomiar obciążenia pętli wtórnej Test krzywej linii błędu dla przekładnika prądowego ochrony Test parametrów przejściowych CT Zgadnij tabliczkę znamionową CT Pomiar krzywej pętli histerezy nasycenia Testy przekładnika napięciowego: Test przełożenia i błędu kąta fazowego Test polaryzacji Test dodatkowego obciążenia Test rezystancji uzwojenia

  • Demo Registration | KPM India |Demo Registration

    Register today for demonstrations of KPM Electrical Testing Equipment. Formularz zapytania o usługę

  • About Us | KPM Engineering Solutions Pvt. Ltd.|Privacy & Disclaimer

    KPM ENGINEERING SOLUTIONS is electrical test equipment provider with strong support. Our solutions are Relay Test Kit, CT/PT Analyzer, Oil BDV, Tan delta , Circuit Breaker Analyzer, LA Testing,Partial Discharge Test Kit, Thermal Imager Camera, PIK, SIK, AC/DC HIPOT. Visit us @ www.kpmtek.com Polityka Prywatności KPM Witamy w KPM Privacy Center — rozejrzyj się. Dowiesz się, jak KPM traktuje Twoje dane osobowe, a także sposoby kontrolowania Twoich preferencji i ustawień. Jak zawsze, KPM dokłada wszelkich starań, aby zdobyć Twoje zaufanie. Co obejmuje niniejsza Polityka prywatności KPM traktuje poważnie Twoją prywatność. Przeczytaj poniższe informacje, aby dowiedzieć się więcej o naszej polityce prywatności. Jak KPM wykorzystuje Twoje dane osobowe Niniejsza polityka opisuje sposób, w jaki KPM traktuje dane osobowe, które KPM zbiera i otrzymuje, w tym informacje związane z Twoim wcześniejszym korzystaniem z usług KPM _cc781905-5cde-3194-bb3b-158bad5cf . Dane osobowe to informacje o Tobie, które umożliwiają identyfikację, takie jak imię i nazwisko, adres, adres e-mail lub numer telefonu, i które nie są publicznie dostępne w inny sposób. Niniejsza polityka prywatności dotyczy wyłącznie KPM Niniejsza polityka nie ma zastosowania do praktyk firm, których KPM nie posiada ani nie kontroluje, ani do osób, których KPM nie zatrudnia ani którymi nie zarządza. Ponadto niektóre firmy przejęte przez KPM has mają własne, istniejące wcześniej polityki prywatności, z którymi można się zapoznać na naszej stronie firm przejętych. Gromadzenie i wykorzystywanie informacji Ogólny KPM zbiera dane osobowe, gdy rejestrujesz się w KPM, kiedy korzystasz z produktów lub usług KPM , kiedy odwiedzasz strony KPM _cc781905-5cde-3194-bb3b-58d_pages niektórych partnerów KPM partners oraz gdy bierzesz udział w promocjach lub loteriach. KPM może łączyć posiadane przez nas informacje o Tobie z informacjami, które uzyskujemy od partnerów biznesowych lub innych firm. Podczas rejestracji prosimy o podanie takich informacji, jak imię i nazwisko, adres e-mail, data urodzenia, płeć, kod pocztowy, zawód, branża i zainteresowania osobiste. W przypadku niektórych produktów i usług finansowych, jeśli są oferowane, możemy również poprosić o adres i informacje o twoich aktywach. Kiedy rejestrujesz się w KPM i logujesz się do naszych usług, nie jesteś dla nas anonimowy. KPM zbiera informacje o twoich transakcjach z nami i niektórymi naszymi partnerami biznesowymi, w tym informacje o korzystaniu przez ciebie z produktów i usług finansowych, jeśli są oferowane. KPM automatycznie odbiera i zapisuje informacje z Twojego komputera i przeglądarki, w tym Twój adres IP, informacje KPM cookie, atrybuty oprogramowania i sprzętu oraz żądaną stronę. Ponadto, korzystając z usług KPM, możesz zdecydować się na upublicznienie niektórych swoich danych osobowych. Jeśli publikujesz w Internecie publicznie dostępne dane osobowe, możesz otrzymywać w zamian niezamówione wiadomości od innych stron, a KPM nie ponosi odpowiedzialności za wykorzystanie lub niewłaściwe wykorzystanie takich informacji. KPM wykorzystuje informacje do następujących ogólnych celów: dostosowywania wyświetlanych reklam i treści, spełniania próśb o produkty i usługi, ulepszania naszych usług, kontaktowania się z Tobą, prowadzenia badań i dostarczania anonimowych raportów dla wewnętrznych i klientów zewnętrznych. KPM nie ponosi odpowiedzialności za dokładność, kompletność, prawdziwość ani niezawodność jakichkolwiek reklam i treści, produktów lub usług, które mogą być dostępne lub reklamowane, a KPM nie będzie ponosi odpowiedzialności za wszelkie straty lub szkody z tego wynikające. KPM nie wynajmuje, nie sprzedaje ani nie udostępnia danych osobowych o Tobie innym osobom ani niepowiązanym firmom, z wyjątkiem dostarczania produktów lub usług, o które prosiłeś, gdy mamy Twoją zgodę lub na następujących warunkach okoliczności: Udostępniamy te informacje zaufanym partnerom, którzy pracują w imieniu lub z KPM w ramach umów o zachowaniu poufności. Firmy te mogą wykorzystywać Twoje dane osobowe, aby pomóc KPM komunikować się z Tobą w sprawie ofert od KPM i naszych partnerów marketingowych. Firmy te nie mają jednak żadnego niezależnego prawa do udostępniania tych informacji. Reagujemy na wezwania sądowe, nakazy sądowe lub procesy prawne lub w celu ustanowienia lub wykonania naszych praw lub obrony przed roszczeniami prawnymi. Uważamy, że dzielenie się informacjami jest konieczne w celu zbadania, zapobiegania lub podejmowania działań dotyczących nielegalnych działań, podejrzeń o oszustwo, sytuacji związanych z potencjalnym zagrożeniem bezpieczeństwa fizycznego dowolnej osoby, naruszeń warunków użytkowania KPM lub w innych przypadkach przez prawo. Przekazujemy informacje o Tobie, jeśli KPM zostanie przejęty przez inną firmę lub połączony z nią. W takim przypadku KPM powiadomi Cię, zanim informacje o Tobie zostaną przekazane i będą podlegać innej polityce prywatności. KPM displays ukierunkowane reklamy oparte na danych osobowych. Reklamodawcy (w tym firmy wyświetlające reklamy) mogą zakładać, że osoby, które wchodzą w interakcję z reklamami kierowanymi, oglądają je lub klikają, spełniają kryteria kierowania — na przykład kobiety w wieku 18-24 lata z określonego obszaru geograficznego. KPM nie przekazuje reklamodawcom żadnych danych osobowych podczas interakcji z reklamą ukierunkowaną lub przeglądania jej. Jednak wchodząc w interakcję z reklamą lub ją przeglądając, wyrażasz zgodę na to, że reklamodawca przyjmie założenie, że spełniasz kryteria kierowania użyte do wyświetlenia reklamy. KPM może kontaktować się z Tobą za pośrednictwem usług telefonicznych stron trzecich w celu promocji lub dyskusji na dany temat. KPM współpracuje z dostawcami, partnerami, reklamodawcami i innymi dostawcami usług w różnych branżach i kategoriach biznesowych. Aby uzyskać więcej informacji na temat dostawców produktów lub usług, o które prosiłeś, przeczytaj nasze szczegółowe linki referencyjne. Ciasteczka KPM może ustawiać i uzyskiwać dostęp do plików KPM cookies na Twoim komputerze. KPM pozwala innym firmom, które wyświetlają reklamy na niektórych naszych stronach, ustawiać i uzyskiwać dostęp do plików cookie na Twoim komputerze. Korzystanie z plików cookie przez inne firmy podlega ich własnym politykom prywatności, a nie tej. Reklamodawcy lub inne firmy nie mają dostępu do plików cookie KPM. KPM wykorzystuje sygnały nawigacyjne w celu uzyskania dostępu do KPM cookies wewnątrz i na zewnątrz naszej sieci stron internetowych oraz w związku z KPM _cc781905-5cde-3194-bb3b-158d_services and.productsf5 Twoja możliwość edytowania i usuwania informacji o koncie i preferencji Ogólny Możesz edytować swoje informacje KPM Account, w tym preferencje marketingowe, w dowolnym momencie. Od czasu do czasu do strony Preferencje marketingowe mogą być dodawane nowe kategorie komunikacji marketingowej. Użytkownicy odwiedzający tę stronę mogą zrezygnować z otrzymywania w przyszłości komunikatów marketingowych z tych nowych kategorii lub mogą zrezygnować z subskrypcji, postępując zgodnie z instrukcjami zawartymi w otrzymywanych wiadomościach. Zastrzegamy sobie prawo do wysyłania użytkownikowi pewnych komunikatów związanych z usługą KPM , takich jak ogłoszenia o usługach, wiadomości administracyjne i biuletyn KPM Newsletter, które są uważane za część KPM account, bez możliwości rezygnacji z ich otrzymywania. Możesz usunąć swoje konto KPM account, prosząc nas o usunięcie konta. Poufność i bezpieczeństwo Ograniczamy dostęp do Twoich danych osobowych do pracowników, którzy naszym zdaniem zasadnie potrzebują kontaktu z tymi informacjami, aby dostarczać Ci produkty lub usługi lub wykonywać swoją pracę. Posiadamy fizyczne, elektroniczne i proceduralne zabezpieczenia, które są zgodne z przepisami federalnymi w celu ochrony Twoich danych osobowych. Aby dowiedzieć się więcej o bezpieczeństwie, w tym o krokach bezpieczeństwa, które podjęliśmy i krokach bezpieczeństwa, które możesz podjąć, przeczytaj Bezpieczeństwo w KPM . Zmiany w niniejszej Polityce prywatności KPM może zaktualizować tę politykę. Powiadomimy Cię o istotnych zmianach w sposobie, w jaki traktujemy dane osobowe, wysyłając powiadomienie na główny adres e-mail podany na Twoim koncie KPM account lub umieszczając widoczne powiadomienie na naszej stronie. Pytania i sugestie Jeśli masz pytania lub sugestie, wypełnij a formularz zwrotny lub możesz skontaktować się z nami pod adresem: sprzedaż@kpmtek.com Anchor 1

  • PD Detector (Digital) | KPM India |PD Detector (Digital)

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Digital) |https://kpmtek.wixsite.com/website/pl/pd-detector-digital Detektor wyładowań niezupełnych (cyfrowy)

  • Non PD Coupling Capacitor | KPM India |Non PD Coupling Capacitor

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Non PD Coupling Capacitor |https://kpmtek.wixsite.com/website/pl/coupling-capacitor Kondensator sprzęgający bez PD

bottom of page