  • PD Solutions| KPM Engineering Sol.|Partial Discharge

    KPM's Partial discharge range of equipment are as below -: 1) Hand Held PD monitoring units used by electrical maintenance & repair professionals. 2) HV laboratory PD Monitoring Systems used by manufacturers 3) Online PD monitoring facilities used for PD monitoring of critical PD Resources MONITOROWANIE PD I UZIEMIENIA ONLINE KPM PENTA PD (HAND HELD) View more Partial Discharge Detector Penta-PD is an ideal partner for condition-based maintenance programs. Partial Discharge Detector Penta-PD incorporates all 5 types of online PD sensor technology. Information from multiple sensors gives Partial Discharge Detector Penta-PD the versatility to detect various type PD in variety of substation apparatus. KPM PDM-01,Partial Discharge Monitor View more The KPM PDM-01 partial discharge detector stands out as a versatile digital tool within KPM's product range. Featuring a 10.1-inch touch screen, it replaces the traditional oscilloscope tube and physical knob operation, enhancing user convenience. The instrument employs a full touch screen interface, contributing to extended product longevity and incorporates useful features such as automatic correction, high voltage divider ratio settings, and serial communication for uploading test data. KPM PDTI Cable Termination Monitor View more The KPM PDTI system is deployed on primary switching equipment such as ring network switch cabinets, cable termination boxes, and transformer output cables etc. within the power distribution network. Its primary function is to conduct online monitoring of partial discharge, indicating potential short circuits and ground faults in corresponding cable sections, along with real-time temperature monitoring. KPM Corona Pointer View more KPM Corona Pointer is an ideal equipment for condition-based maintenance programs. Online partial discharge testing is a method of inspecting the insulation of electric power systems while equipment remains energized and in service. Corona Pointer is based on online Ultrasonic PD sensor technology. KPM Duo PD - Handheld PD monitoring system View more KPM Duo PD is a handheld partial discharge tester which uses the ultrasonic signal generated by partial discharge to determine the existence and location of partial discharge and combines the real-time displayed images and data to quickly diagnose partial discharge conditions. KPM PDA-01, Partial Discharge Monitor View more The KPM PDA-01 features a split, modular design, with the local discharge signal conditioning module, digital acquisition module, and test voltage acquisition module integrated into the instrument. The powerful local discharge test and analysis system software is installed on the host computer, which connects to the instrument via USB and RS232 serial ports. KPM PD Pulse-8, Online Partial Discharge Monitor View more KPM PD Pulse-8 partial discharge online monitoring device includes a modularly designed partial discharge sensor and a partial discharge data processing terminal. The partial discharge sensor can effectively monitor ultrasonic and transient earth voltage signals. Its sensors are a two-in-one integrated assembly that can be installed on the HV equipment. Często zadawane pytania ( FAQ ) FAQ about Partial discharge : 01 What are the Top 5 PD Testing Techniques – A Quick Comparison? 1) Ultrasonic PD Detection - Detects sound waves from PD events - Portable, good for on-site inspections - Limited sensitivity in noisy environments 2) High-Frequency Current Transformer (HFCT) - Measures high-frequency currents on cables - Effective for early PD detection - Requires access to grounding points 3) Transient Earth Voltage (TEV) - Detects electromagnetic signals from PD inside metal enclosures - Non-intrusive and widely used in switchgear - Limited for external PD sources 4) Oscilloscopic PD Measurement - Directly captures PD pulses using specialized sensors - Very detailed and accurate - Requires expert analysis and controlled environment 5) Acoustic Emission (AE) Sensors - Captures elastic waves from PD activity - Useful for localizing PD sources - Can be affected by external noise - KPM offers advanced PD measurement systems combining multiple techniques for comprehensive, reliable diagnostics. 02 What do you understanding AE, HFCT, TEV, and UHF – Which PD Kit Do You Need? Choosing the right Partial Discharge (PD) testing kit depends on your equipment type, accessibility, and testing goals. Here’s a quick comparison: 1. AE – Acoustic Emission How it works: Detects sound waves from PD using piezoelectric sensors. Best for: Transformers, bushings, and GIS (localizing PD points). Pros: Non-invasive, good for pinpointing PD. Limitations: Sensitive to external noise. 2. HFCT – High-Frequency Current Transformer How it works: Clamped around the grounding conductor to detect PD pulses. Best for: Cables, terminations, rotating machines. Pros: Early detection, non-intrusive. Limitations: Needs grounding access; less effective in noisy ground systems. 3. TEV – Transient Earth Voltage How it works: Senses electromagnetic emissions on metal-clad switchgear. Best for: MV switchgear (metal-enclosed). Pros: Easy to use, fast screening. Limitations: Doesn’t work well on non-metallic enclosures. 4. UHF – Ultra High Frequency How it works: Captures high-frequency EM waves from PD (300 MHz+). Best for: GIS, gas-insulated transformers, sealed systems. Pros: Very sensitive and noise-immune. Limitations: Needs access to UHF sensors or couplers. Which Kit Do You Need? For switchgear: TEV + AE For cables and rotating machines: HFCT For GIS or sealed systems: UHF + AE For transformers and bushings: AE + HFCT KPM offers hybrid PD testing kits combining AE, TEV, HFCT, and UHF sensors for complete diagnostics across all asset types—helping you localize, classify, and trend PD activity efficiently. 03 What is principle of detecting PD in Switchgear Using TEV Method ? The Transient Earth Voltage (TEV) method detects partial discharge activity in metal-clad switchgear by capturing fast, high-frequency voltage transients that appear on the internal metal surfaces of the switchgear enclosure. How It Works: When partial discharge occurs inside the insulation of live parts (e.g., busbars, bushings), it emits electromagnetic pulses. These pulses induce high-frequency voltage transients on the inner surface of the switchgear's metal enclosure. These transients propagate through the metal, eventually reaching the outer surface. A TEV sensor, placed magnetically or capacitively on the metal surface, detects these transient voltages—typically in the range of MHz frequencies. Why It Works Well for Switchgear: Switchgear panels are metal-enclosed, which acts as a waveguide for the transient signals. TEV signals indicate internal insulation defects like surface tracking, void discharges, or corona inside the equipment. TEV detection is non-invasive, requires no shutdown, and is widely used for condition-based maintenance. What TEV Tells You: Presence of internal PD Severity of the discharge (by amplitude and repetition rate) Useful for early detection before insulation failure KPM’s PD testing kits integrate TEV sensors with digital displays and trending software, making it easy to perform on-site diagnostics of medium-voltage switchgear for early PD detection and risk assessment. 04 What are the Diagnosing Cable Defects With HFCT-Based PD Testing ? High-Frequency Current Transformer (HFCT) sensors are widely used for detecting and diagnosing partial discharge (PD) activity in power cables. They are clamped around the earth (ground) conductor to sense high-frequency current pulses generated by insulation defects. How HFCT PD Testing Works: PD Activity Inside Cable Insulation: Voids, cracks, or deteriorated insulation cause small electrical discharges. Pulse Propagation: These discharges generate high-frequency current pulses (MHz range) that flow along the grounding system. HFCT Sensor Detection: The HFCT sensor detects these pulses non-invasively by clamping it around the cable’s earth conductor without disconnecting the system. Signal Analysis: The captured pulses are analyzed for: Pulse shape and repetition rate Time-of-flight (for PD location) Amplitude and phase-resolved patterns (PRPD) What It Diagnoses: Defects in cable joints, terminations, insulation Water trees or aging in XLPE cables Internal corona or tracking activity Advantages of HFCT PD Testing: Online or offline testing possible Non-intrusive and safe Early detection prevents costly cable failures Can be used with multiple sensors for PD location (triangulation) KPM’s HFCT-based PD testing solutions are designed for rapid setup, high sensitivity, and advanced diagnostics—enabling utilities and industries to monitor cable health with confidence. 05 What is UHF PD Testing in GIS – High Sensitivity Explained? Ultra High Frequency (UHF) PD testing in Gas-Insulated Switchgear (GIS) is a highly sensitive method that detects partial discharge by capturing electromagnetic signals in the 300 MHz to 1.5 GHz range. GIS enclosures, being metallic and sealed, confine PD signals and create a low-noise environment—making UHF detection extremely effective. UHF sensors, typically built into or attached to the GIS via couplers or antennae, pick up these fast transients without interfering with system operation. This method offers excellent immunity to external noise and allows early detection of insulation defects such as voids, surface discharges, or corona, enabling preventive maintenance and reducing outage risk. KPM’s UHF PD solutions are optimized for GIS testing, offering precise, real-time diagnostics with minimal intrusion. 06 How PD Can Cause Catastrophic Failures If Left Undetected ? Partial Discharge (PD) is a small electrical spark that occurs within insulation systems due to defects like voids, cracks, or contamination. While each discharge releases only a small amount of energy, repeated activity degrades insulation over time, leading to progressive damage. If left undetected, PD can cause tracking, erosion, thermal breakdown, and eventually a complete insulation failure. This can result in catastrophic equipment breakdowns, fires, arc flash events, or prolonged outages. Early PD detection helps identify developing faults before they escalate, allowing timely intervention. KPM’s PD monitoring solutions provide accurate diagnostics to prevent such costly and dangerous failures. 07 How Often Should You Perform Partial Discharge Tests? The frequency of Partial Discharge (PD) testing depends on equipment type, criticality, age, and operating environment: New Installations: Test during commissioning to detect manufacturing or installation defects. Routine Maintenance: For critical assets (e.g., GIS, transformers, cables): annually or semi-annually For less critical systems: every 2–3 years Condition-Based Monitoring: For aging or high-risk equipment, use continuous or periodic online PD monitoring. After Major Events: Test after faults, repairs, or overloading. KPM offers both portable and continuous PD monitoring solutions tailored to asset condition and reliability goals. 08 What is Acoustic Emission for PD Detection – Emerging Trends? Acoustic Emission (AE) is an emerging technique in Partial Discharge (PD) detection, leveraging sound waves generated by PD activity within high-voltage equipment. AE sensors capture ultrasonic emissions, allowing non-intrusive, real-time monitoring of insulation health. Recent trends include the integration of AI algorithms for noise discrimination, wireless AE sensor networks for wide-area monitoring, and hybrid systems combining AE with UHF or HFCT methods for higher accuracy. KPM’s PD monitoring device incorporates these advancements by using sensitive AE sensors to detect PD in transformers, switchgear, and cable terminations. The system filters external noise and correlates AE signals with discharge activity, ensuring precise fault localization. Its compact design, cloud integration, and user-friendly interface make it suitable for continuous condition monitoring. This enables utilities to predict insulation failure early, plan timely maintenance, and improve grid reliability while aligning with modern digital substation standards. 09 What to Watch Out For while working on PD Testing in Motors and Generators ? Partial Discharge (PD) testing in motors and generators is critical for identifying early insulation deterioration, especially in high-voltage rotating machines. Key factors to watch out for include surface discharge near end windings, slot discharges, and internal PD caused by insulation voids. External noise interference, poor sensor placement, and incorrect test settings can lead to false readings or missed defects. It’s essential to differentiate between actual PD signals and electrical noise, especially in operational (online) testing. KPM’s PD tester addresses these challenges with high-frequency current transformer (HFCT) sensors, advanced noise separation algorithms. The device enables clear PD signal capture even in electrically noisy environments. It provides real-time analysis, waveform capture, and trend data, helping maintenance teams make informed decisions. KPM’s compact, rugged design and intuitive interface make it ideal for field diagnostics in motors and generators across power plants and industrial sites. 10 How to Interpret PD Signals? Interpreting Partial Discharge (PD) signals is crucial for diagnosing insulation issues accurately. Real-world case studies reveal that many failures arise not from PD presence, but from misinterpretation. In one case, a generator end-winding PD signal was mistaken for noise due to poor sensor grounding. Another involved a cable joint where increasing PD magnitude over time indicated a void-related breakdown—early intervention prevented a costly outage. Key learnings include the importance of phase-resolved PD (PRPD) pattern analysis, baseline signal comparison, and monitoring PD trends over time. Environmental noise, load conditions, and sensor placement significantly impact data quality. KPM’s PD tester simplifies interpretation with built-in PRPD pattern recognition, automated classification, and trend analytics. Its intelligent algorithms filter out noise and identify critical PD types—internal, surface, or corona—with high accuracy. By offering both real-time insights and historical tracking, KPM's tester empowers engineers to make confident maintenance decisions and extend asset life. FAQ about Monitoring testing : 01 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? • Using both TEV and ultrasonic methods together enhances diagnostic accuracy: • • TEV gives insight into internal discharge severity and location. • • Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. • • This dual-method approach is vital for: • • Preventive maintenance, • • Avoiding insulation failures, • • Improving switchgear reliability, and • • Extending equipment life without needing shutdowns.

  • LA Test Kit | KPM Engineering

    KPM LA100+ & KPM LA 103+ is used for testing health of lightning arresters. It is also known as MOA Tester , Surge Arrester Tester/leakage current monitor/LCM etc. https://www.kpmtek.com/lightningarrestertestkit ZESTAW TESTOWY ODGROMOWNIKA (LCM) Teoria Tester odgromników 1-fazowych online (z pomiarem napięcia i prądu) Katalog Tester odgromników firmy KPM (KPM LA-100+) to specjalny przyrząd służący do wykrywania właściwości elektrycznych odgromników (LA/MOSA). KPM LA-100+ is zdolność do testowania LA online przy użyciu pomiaru prądu upływowego LA i napięcia PT bezpośrednio dla najbardziej wiarygodnych wyników IEC . Cechy produktu of Test odgromnika (KPM LA-100+) Duży ekran LCD, menu użytkownika w języku angielskim, łatwy w użyciu. Korzystaj z technik precyzyjnego próbkowania i analizy harmonicznej Fouriera, aby uzyskać wiarygodne dane. Mierzy prąd rezystancyjny trzeciej harmonicznej , Całkowity prąd rezystancyjny , Całkowity prąd upływu ,_cc781905-5cde-3194-bb3b-136bad5cf58 Akumulator, zegar z kalendarzem, wbudowana mikrodrukarka, może przechowywać 120 grupowych danych pomiarowych Online 3 Ph LA Tester (z bezprzewodowym czujnikiem E i pomiarem prądu) Katalog KPM's 3-fazowy tester odgromników(KPM LA-103+) to specjalny przyrząd do wykrywania właściwości elektrycznych odgromników (LA/MOSA). KPM LA-103+ is zdolny do testowania LA online przy użyciu sześciu głównych metod zgodnie z IEC -: 1. Duży ekran LCD, pełna obsługa menu w języku angielskim, łatwy w użyciu. 2 Korzystanie z precyzyjnych obwodów próbkowania i przetwarzania, zaawansowane techniki analizy harmonicznej Fouriera w celu zapewnienia wiarygodności danych. 3. Instrument wykorzystuje sygnały napięcia i prądu bezpośrednio przechwytywane i wprowadzane przez unikalny szybki cyfrowy czujnik izolacji magnetycznej, aby zapewnić niezawodność i bezpieczeństwo danych 4. To urządzenie może wykorzystywać indukowane pole elektryczne lub metodę transmisji bezprzewodowej zamiast wtórnego okablowania PT. 5. Przyrząd nie musi łączyć wtórnego PT i może bezpośrednio mierzyć prąd rezystancyjny. 6. Istnieje sześć metod testowania, zapewniających wiele możliwości wyboru dla osoby na miejscu. ( PT metoda wtórna, metoda indukcyjna, metoda transmisji bezprzewodowej, metoda synchronizacji pojedynczego prądu, metoda synchronizacji wtórnej pt) Online 3 Ph LA Tester (z bezprzewodowym czujnikiem E i pomiarem prądu) Katalog KPM's 3-fazowy tester odgromników(KPM LA-103+) to specjalny przyrząd do wykrywania właściwości elektrycznych odgromników (LA/MOSA). KPM LA-103+ is zdolny do testowania LA online przy użyciu sześciu głównych metod zgodnie z IEC -: 1. Duży ekran LCD, pełna obsługa menu w języku angielskim, łatwy w użyciu. 2 Korzystanie z precyzyjnych obwodów próbkowania i przetwarzania, zaawansowane techniki analizy harmonicznej Fouriera w celu zapewnienia wiarygodności danych. 3. Instrument wykorzystuje sygnały napięcia i prądu bezpośrednio przechwytywane i wprowadzane przez unikalny szybki cyfrowy czujnik izolacji magnetycznej, aby zapewnić niezawodność i bezpieczeństwo danych 4. To urządzenie może wykorzystywać indukowane pole elektryczne lub metodę transmisji bezprzewodowej zamiast wtórnego okablowania PT. 5. Przyrząd nie musi łączyć wtórnego PT i może bezpośrednio mierzyć prąd rezystancyjny. 6. Istnieje sześć metod testowania, zapewniających wiele możliwości wyboru dla osoby na miejscu. ( PT metoda wtórna, metoda indukcyjna, metoda transmisji bezprzewodowej, metoda synchronizacji pojedynczego prądu, metoda synchronizacji wtórnej pt) Theory - LA Tester Test teoretyczny piorunochronu Piorunochron – Teoria Odgromnik to urządzenie stosowane w systemach elektroenergetycznych i systemach telekomunikacyjnych w celu ochrony izolacji. i przewodniki instalacji przed szkodliwym działaniem wyładowań atmosferycznych. Typowy odgromnik ma zacisk wysokiego napięcia i zacisk uziemienia. Gdy wyładowanie atmosferyczne (lub przepięcie przełączające) przemieszcza się wzdłuż linii energetycznej do ogranicznika, prąd z przepięcia jest kierowany przez ogranicznik, w większości przypadków do ziemi. Jeśli ochrona zawiedzie lub jej nie ma, piorun, który uderza w instalację elektryczną, wprowadza tysiące kilowoltów, które mogą uszkodzić linie przesyłowe, a także mogą spowodować poważne uszkodzenie transformatorów i innych urządzeń elektrycznych lub elektronicznych. Wytwarzane przez wyładowania atmosferyczne ekstremalne skoki napięcia w przychodzących liniach energetycznych mogą również uszkodzić elektryczne urządzenia domowe, dlatego jest to cholernie ważne dla integralności odgromnika. Obecnie monitorowanie całkowitego prądu upływu (prądów pojemnościowych i rezystancyjnych) jest wykorzystywane przez wiele zakładów energetycznych. Monitory prądu upływu służą do pomiaru prądu upływu ochronników przepięciowych, aw przypadku wysokiego prądu upływu ochronniki przepięciowe są wymieniane. Jednak uważa się, że ta metoda nie jest metodą niezawodną, ponieważ całkowity prąd upływowy, który jest czysto pojemnościowy, nie oznacza dokładnie stanu ograniczników przepięć. Zdarzały się przypadki, gdy ograniczniki przepięć wybuchały, mimo że całkowita wartość prądu upływu była poniżej limitu określonego przez producentów. Prąd rezystancyjny stanowi 15-30% prądu całkowitego, a ponieważ prądy pojemnościowe i rezystancyjne są przesunięte o 90 stopni, nawet znaczna zmiana prądu rezystancyjnego powoduje bardzo mały wzrost prądu całkowitego. Dlatego monitorowanie całkowitego prądu upływu może nie wskazywać na degradację krążka ZnO. Degradacja długiego liniowego krążka ZnO generalnie prowadzi do powstawania harmonicznych w prądzie upływu, gdy przyłożone jest napięcie systemowe o częstotliwości podstawowej. Pomiar rezystancji trzeciej harmonicznej polega na odfiltrowaniu składowej trzeciej harmonicznej z całkowitego prądu upływu. Prąd upływu rzędu około 500 mikroamperów jest ogólnie uważany za bezpieczny. Część rezystancyjną prądu upływu lub stratę mocy można określić kilkoma metodami podanymi poniżej: Używanie sygnału napięciowego jako odniesienia Kompensacja składowej pojemnościowej za pomocą sygnału napięciowego Kompensacja pojemnościowa poprzez połączenie prądu upływu trzech faz Analiza harmoniczna trzeciego rzędu Bezpośrednie wyznaczanie strat mocy Analiza harmonicznych trzeciego rzędu z kompensacją harmonicznych w napięciu Zaawansowany system monitorowania z obliczeniami składowych „prądu rezystancyjnego”. Zastosowanie zaawansowanych metod diagnostycznych znacznie zmniejsza ryzyko awarii, a tym samym pozwala uniknąć strat ludzkich i finansowych. Dlatego pożądane jest sprawdzanie stanu ograniczników przepięć w regularnych odstępach czasu, poprzez pomiar składowej rezystancyjnej ciągłego prądu upływu podczas pracy bez odłączania ogranicznika od napięcia. Wiarygodne pomiary są osiągane przez przyrządy oparte na zasadzie „sygnału napięcia” jako odniesienia. Regularne monitorowanie LA zapobiegło wielu awariom w stacjach od 66 kV do 765 kV. Wartości tego prądu zwykle wahają się od ułamków miliamperów do kilku miliamperów i charakteryzują się wahaniami prądu rezystancyjnego, których wartość jest wskaźnikiem zużycia ogranicznika przepięć. Składowa rezystancyjna tego prądu upływowego może wzrosnąć z powodu różnych naprężeń powodujących starzenie się i ostatecznie powodujących awarie ograniczników. Często zadawane pytania ( FAQ ) FAQ about lightning arrester testing : 01 What is the purpose of online testing for lightning arresters? The purpose of online testing for HV lightning arresters is to evaluate their health and operational condition while they remain energized and connected to the high-voltage system. This non-intrusive testing monitors critical parameters—especially leakage current—to detect early signs of insulation degradation, moisture ingress, or internal damage. By performing these tests without disconnecting the arrester, utilities can ensure continuous protection against transient over voltages, prevent unexpected failures, and schedule maintenance proactively, thereby enhancing system reliability and safety. 02 How does online testing differ from offline testing of lightning arresters? Online testing of lightning arresters is performed while the arrester is energized and connected to the live high-voltage system. It monitors parameters like leakage current and voltage in real time to assess the arrester’s condition without interrupting power supply or removing the arrester from service. Offline testing, on the other hand, requires disconnecting the arrester from the system and applying controlled test voltages or impulses in a laboratory or test environment. This allows detailed diagnostic tests, such as insulation resistance, dielectric withstand, and energy absorption capability, but causes downtime and power disruption. In summary, online testing enables continuous condition monitoring without service interruption, while offline testing offers more comprehensive diagnostics but requires taking the arrester out of operation. 03 What parameters are measured during online testing of lightning arresters? During online testing of lightning arresters, the key parameters measured include: Leakage current: Both resistive and capacitive components are monitored to detect insulation deterioration or moisture ingress. Discharge current: Measures the arrester’s response to transient overvoltages. Voltage across the arrester: To correlate leakage current with operating voltage. Power factor (dissipation factor): Indicates the level of insulation losses and ageing. Harmonic content of leakage current: Helps identify partial discharges or defects. Continuous monitoring of these parameters helps identify early signs of failure and evaluate arrester condition in real time. 04 What types of leakage current patterns indicate a failing arrester? In surge arresters (typically metal oxide varistor or MOV-based), leakage current patterns can offer early warning signs of deterioration or failure. Here are the key types of leakage current patterns that indicate a failing arrester: 1. Increasing Total Leakage Current Over Time What it means: The arrester is gradually losing its insulation resistance. Cause: Ageing of the zinc oxide blocks or moisture ingress. Warning: A consistent upward trend is a red flag — especially under normal system voltage. 2. High Resistive Leakage Current What it means: An increase in resistive (non-linear) current indicates internal degradation. Why it's critical: Unlike capacitive leakage (which is normal), resistive leakage is a sign of arrester deterioration. How it shows up: Measured using third-harmonic analysis or waveform separation techniques. 3. Sudden Jumps or Spikes in Leakage Current What it means: Possible internal flashover, moisture ingress, or external contamination. Typical sign: A sharp increase without a gradual trend. Next step: Immediate inspection or replacement is usually advised. 4. Leakage Current with Strong Daily Variation What it means: Leakage current rises during daytime due to heating and falls at night — abnormal if variation is large. Potential cause: Moisture or contamination interacting with thermal cycles. 5. Phase Shift Changes in Leakage Current What it means: The phase angle between voltage and leakage current shifts — especially the third harmonic. Used in: Online monitoring systems. Why it matters: Indicates the balance between capacitive and resistive components is shifting unfavourably. 6. Leakage Current under Wet Conditions What it means: If leakage current increases dramatically during rain or fog, it may indicate surface tracking or contamination. Action: Cleaning or replacing the arrester may be required. 05 Which standard is most widely accepted worldwide? The IEC 60099-4 standard (from the International Electrotechnical Commission) is the most widely accepted global standard for metal-oxide lightning arresters. It defines performance criteria, testing procedures—including online monitoring methods—and requirements for high-voltage arresters used in power systems. The B2 method for assessing leakage current in metal-oxide surge arresters is detailed in the IEC 60099-4 standard — specifically in IEC 60099-4:2013, titled "Surge arresters — Part 4: Metal-oxide surge arresters without gaps for AC systems — Methods of test". This standard outlines how to measure and analyze leakage current components, including the resistive part used in the B2 method, for condition assessment and online monitoring of high-voltage lightning arresters. 06 Do you know Which parameter are measured in IEC 60099-4 B2 Method ? In the B2 method, leakage current measurement is used to evaluate the condition of a metal-oxide lightning arrester by analyzing its resistive (non-capacitive) leakage current component while the arrester is energized at operating voltage. Here’s how it works: Measurement: The total leakage current flowing through the arrester is measured using sensitive instruments. This current consists of a capacitive component (normal and stable) and a resistive component (indicative of arrester aging or damage). Resistive component isolation: The B2 method focuses on isolating the resistive part of the leakage current, as an increase in resistive current usually signals degradation, moisture ingress, or damage to the arrester’s internal varistors. Analysis: By comparing the measured resistive leakage current to baseline or manufacturer’s reference values, the condition of the arrester can be assessed. A rising resistive leakage current over time indicates deteriorating insulation and the potential for failure. Trend monitoring: Periodic measurements allow trend analysis, helping predict the arrester’s remaining life and plan maintenance before catastrophic failure occurs. This method is widely used because it is sensitive, non-invasive, and can be performed online without disconnecting the arrester. 07 Which compensations are taken care in B2 method typically In the B2 method, leakage current measurement is used to evaluate the condition of a metal-oxide lightning arrester by analyzing its resistive (non-capacitive) leakage current component while the arrester is energized at operating voltage. Here’s how it works: Measurement: The total leakage current flowing through the arrester is measured using sensitive instruments. This current consists of a capacitive component (normal and stable) and a resistive component (indicative of arrester aging or damage). Resistive component isolation: The B2 method focuses on isolating the resistive part of the leakage current, as an increase in resistive current usually signals degradation, moisture ingress, or damage to the arrester’s internal varistors. Analysis: By comparing the measured resistive leakage current to baseline or manufacturer’s reference values, the condition of the arrester can be assessed. A rising resistive leakage current over time indicates deteriorating insulation and the potential for failure. Trend monitoring: Periodic measurements allow trend analysis, helping predict the arrester’s remaining life and plan maintenance before catastrophic failure occurs. This method is widely used because it is sensitive, non-invasive, and can be performed online without disconnecting the arrester.

  • Cable testing Solutions| KPM Engineering Sol.|CABLE

    KPM's cable testing kits equpments are as follow:- - KPM TAN DELTA 40 - KPM AC HIPOT - KPM DC HIPOT - KPM VLF Hipot Tester - KPM VLF Series KPM TD 40 MONITOROWANIE PD I UZIEMIENIA ONLINE KPM TAN DELTA 40 KPM TD 40 KPM TD 40 capacitance and tan delta tester is designed for condition assessment of high capacitance & high voltage electrical insulation in high voltage apparatus. It is a measurement instrument that is used with an AC power source and a standard capacitor to form a complete measurement setup. KPM TD 40 is a two-piece design. the control module and the test module communicate wirelessly during the test. KPM DC HIPOT KPM DC HIPOT KPM Portable DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM- DC series of HIPOTs is light weight, portable & easy to use. These units are user friendly & its output is stable at even high voltages DC vs AC High-potential Testing Direct current high-potential testing provides several advantages over alternating current. KPM VLF Series KPM VLF Series KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. KPM AC HIPOT KPM AC HIPTO KPM Portable AC/DC Hipot Test Set consists of a control unit & a double rectifier unit. The KPM-AC/DC series of HIPOTs is light weight , portable & easy to use. These units are user friendly& its output is stable at even high voltages it is the basic test equipment used by the power station, transmission and distribution companies for testing the insulation strength of all kind of electrical products, electrical equipment and insulated materials. KPM VLF Hipot Tester KPM VLF Hipot Tester KPM offers the most portable and easy to use VLF hipots available in market. A VLF hipotis just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 0.1 Hz. Although the frequency is very low, it is still an alternating current with polarity reverses after every half cycle. At 0.1 Hz output, rather than 50Hz, it takes 500 times less current and power to apply an AC voltage to a capacitive load, like a long cable. Często zadawane pytania ( FAQ ) FAQ about Cable testing : 01 1. What is VLF testing, and why is it used for cable diagnostics? VLF (Very Low Frequency) testing applies a low-frequency AC voltage—typically 0.01 Hz to 0.1 Hz—to power cables to assess their insulation condition. It’s used because VLF testing can apply a high voltage stress similar to normal operating conditions but with less heating and damage risk than standard power frequency tests. This makes it ideal for diagnosing medium- and high-voltage cables, especially in field conditions, to detect weaknesses like insulation degradation, voids, or defects before failure occurs. 02 2. How does VLF testing differ from conventional AC hipot testing? VLF testing uses a very low frequency (typically 0.01 to 0.1 Hz) AC voltage, whereas conventional AC hipot testing applies standard power frequency (50/60 Hz) voltage. The low frequency in VLF reduces the capacitive charging current in long cables, allowing high test voltages without overheating the cable insulation. This makes VLF safer and more practical for field testing of long medium- and high-voltage cables. In contrast, conventional AC hipot tests can cause excessive heating and damage when used on such cables. 03 3. What types of cable defects can VLF testing detect? VLF testing is effective at identifying a wide range of insulation defects and weaknesses within medium- and high-voltage power cables. It can detect partial discharge (PD) activity, which is a common early indicator of insulation deterioration such as microscopic voids or cracks within the cable’s insulation material. These PD sites generate localized electrical discharges that degrade the insulation over time, potentially leading to catastrophic failure if not addressed. Additionally, VLF testing can reveal water ingress problems, where moisture penetrates the insulation and lowers its dielectric strength, as well as contamination or aging effects such as thermal, mechanical, or chemical degradation of the insulation material. It can also uncover manufacturing defects like thin spots, improper curing, or insulation gaps. While VLF testing is excellent for assessing the overall integrity of the cable insulation and detecting areas of weakness, it may not precisely locate the defects. For detailed localization, it is often combined with other techniques such as partial discharge (PD) measurements or time-domain reflectometry (TDR). 04 4. What is Tan Delta (VLD) testing, and how does it assess cable insulation quality? Tan Delta (also called Very Low Dissipation factor or VLD) testing measures the dielectric losses in cable insulation by applying an AC voltage and analyzing the phase difference between the current and voltage. The "tan delta" represents the ratio of resistive (lossy) current to capacitive (ideal) current. A low tan delta value indicates good insulation with minimal energy loss, while higher values suggest deterioration due to moisture, contamination, or aging. By measuring these losses, Tan Delta testing assesses the overall insulation condition and detects early-stage degradation before catastrophic failure. It is highly sensitive to insulation quality changes and is commonly used for condition assessment and preventive maintenance of medium- and high-voltage cables. 05 5. How do Tan Delta results indicate the health or degradation of a cable? Tan Delta results reflect the insulation’s dielectric losses, which increase as the cable ages or deteriorates. A low tan delta value means the insulation is healthy, with minimal leakage current and good dielectric integrity. Conversely, a rising tan delta value indicates increasing insulation defects such as moisture ingress, contamination, cracks, or thermal aging. Trends in tan delta over time are especially important: a gradual increase suggests progressive degradation, allowing maintenance teams to plan repairs before failure occurs. Sudden spikes may point to acute damage or contamination. Thus, monitoring tan delta values helps assess the insulation’s condition, predict remaining service life, and prioritize maintenance actions. 06 6. What is VLF Partial Discharge (PD) testing, and how does it help's identify insulation defects? VLF Partial Discharge (PD) testing uses very low frequency voltage to stress the cable insulation while detecting and measuring partial discharges—tiny electrical sparks that occur within insulation voids or defects. These discharges are often early signs of insulation failure, caused by imperfections like cracks, voids, or contamination. By capturing PD activity, VLF PD testing helps pinpoint insulation defects before they lead to catastrophic cable failure. It provides valuable insight into the type, location, and severity of defects, enabling targeted maintenance and reducing unplanned outages. This makes it a crucial tool for proactive cable condition assessment. 07 7. Can VLF PD testing detect early-stage insulation failures? Yes, VLF Partial Discharge (PD) testing is specifically designed to detect early-stage insulation failures. Partial discharges are small electrical sparks that occur in microscopic voids, cracks, or impurities within the cable insulation—often long before a complete breakdown happens. By applying very low frequency voltage, VLF PD testing stresses the insulation gently but effectively, allowing detection of these early PD activities. Detecting partial discharges early helps identify weak spots or developing defects in the insulation, enabling maintenance teams to address issues proactively, extend cable life, and avoid costly unplanned failures. 08 8. What are the typical test voltages and frequencies used in VLF cable testing for 11 kV and 33 kV cables? For 11 kV cables, the VLF test voltage typically ranges from 15 kV to 33 kV, depending on the test type—diagnostic tests usually use about 1.5 times the rated voltage (around 16.5 kV), while withstand tests may apply up to 2.5 to 3 times the rated voltage (up to ~33 kV). For 33 kV cables, the test voltage typically ranges from 45 kV to 75 kV, with diagnostic tests at around 1.5 times the rated voltage (approximately 49.5 kV), and withstand tests potentially up to 2.5 times rated voltage (about 82.5 kV), though the upper limit depends on cable specifications and standards. In both cases, the frequency used is very low—typically 0.1 Hz—to reduce capacitive currents and minimize heating during testing, making it safe and effective for long cable lengths. 09 9. How do environmental factors affect VLF, Tan Delta, and PD test results? Environmental conditions like temperature, humidity, and soil moisture can significantly impact VLF, Tan Delta, and Partial Discharge (PD) test results. Temperature: Higher temperatures generally reduce insulation resistance and can increase Tan Delta values and PD activity due to increased molecular activity in the insulation. Low temperatures can raise resistance but might mask some defects. Humidity and Moisture: Moisture ingress lowers insulation resistance and increases dielectric losses, causing higher Tan Delta readings and more PD activity. Wet conditions can lead to more apparent insulation degradation during testing. Soil Conditions: For underground cables, soil resistivity and moisture affect grounding and test current paths, influencing VLF and PD measurements. Dry or rocky soils may lead to higher resistance readings. Surface Contamination: Dirt, oil, or salts on cable surfaces can cause surface discharges, impacting PD and Tan Delta results. Because of these factors, it’s important to consider and document environmental conditions during testing and, where possible, perform tests under similar conditions for consistent trending and accurate diagnostics. 10 10. What are the safety precautions and best practices during VLF and PD cable testing? • Ensure Proper Training: Only qualified personnel familiar with high-voltage testing and equipment should conduct tests. • Use Appropriate PPE: Wear insulated gloves, safety glasses, and flame-resistant clothing. • Clear the Test Area: Establish a safe perimeter with warning signs and barriers to prevent unauthorized access during testing. • Verify Equipment Condition: Check all test instruments, leads, and connections for damage before use. • De-energize and Ground Cables: Ensure the cable is disconnected from the power system and properly grounded before connecting test equipment. • Follow Manufacturer Guidelines: Use the recommended test voltages, durations, and procedures specific to the cable type and equipment. • Monitor Test Parameters: Continuously observe voltage, current, and PD activity during the test to detect abnormalities early. • Avoid Testing in Hazardous Environments: Do not perform tests during storms, wet conditions, or explosive atmospheres. • Record Test Data Accurately: Document all parameters, environmental conditions, and observations for traceability and analysis. • Emergency Preparedness: Have clear procedures for immediate shutdown and emergency response in case of equipment failure or personnel hazard. • Following these precautions ensures safety and reliable test results while protecting both personnel and equipment.

  • Meter Test Kit | KPM Engineering Sol.

    Energy meter testing equipment 1) Energy meter testing reference ( 1 ph & 3 ph ) 2) Energy meter calibrator ( 3 ph ) 3) Energy meter test bench ( 1 ph & 3 ph ) Testowanie licznika energii Referencyjny licznik energii 3-fazowej — MT 3000D MT 3000D MT 3000D to najnowocześniejszy przenośny trójfazowy miernik energii do testowania i kalibracji liczników energii. MT3000D to łatwe w obsłudze i lekkie urządzenie. MT 3000D jest dostępny w dwóch wersjach dokładności (0,05% i 0,1%) MT3000D to wszystko w jednym urządzeniu z poniższymi funkcjami Automatyczne nieprawidłowe połączenie test Test proporcji Próba harmoniczna Test dokładności miernika (klasa 0,05/1) Wydruk raportu MT 3000B Przenośny trójfazowy miernik kWh na miejscu Kalibrator służy do kalibracji trójfazowego, jednofazowego, czynnego lub biernego licznika energii podczas pracy, a także może być używany jako miernik napięcia, prądu i mocy do pomiaru parametrów AC trójfazowej linii energetycznej , może również mierzyć współczynnik zniekształceń fali i falę harmoniczną od 2 do 63 czasu . Ma następujące cechy: • Zastosuj 32-bitowy procesor ARM, wielokanałowy 16-bitowy precyzyjny konwerter A/D, wyświetlacz TFT LCD o wysokiej rozdzielczości. •Wewnętrzny wyposażony w szerokozakresowy przekładnik prądowy 0,01% i może być wyposażony w różnego rodzaju cęgi prądowe, szeroki zakres pomiarowy i wysoką dokładność. • Projekt obwodu o niskim zużyciu energii, zasilanie bateryjne Li o wysokiej energii, oprogramowanie do zarządzania energią intelektualną, które sprawia, że instrument może pracować nieprzerwanie do 10 godzin Test licznika energii 1-fazowej, nr referencyjny Katalog EMR 1 to najnowocześniejszy przenośny jednofazowy licznik energii do testowania i kalibracji liczników energii . EMR 1 to łatwe w użyciu i lekkie urządzenie. EMR 1 ma dokładność 0,3% Specyfikacje 1. Sprawdź błędy miernika bez odłączania zasilania. 2. Opcjonalna atrapa skrzyni ładunkowej 3. Certyfikat: ISO 9001 Features Specjalna obudowa z tworzywa sztucznego, lekka i łatwa do przenoszenia, wyświetlacz LCD Zmierz napięcie, prąd, moc. fazowy współczynnik mocy bez rozłączania obwodu mocy Sprawdź dodatni/ujemny błąd miernika fazy bez odłączania obwodu zasilania Szeroki zakres cęgów prądowych: 0,5-100A Szeroki zakres napięcia roboczego: AC180 - 250V Zasilanie dostarczane bezpośrednio przez przewód testowy napięcia Wyjście impulsowe energii o wysokiej i niskiej częstotliwości. Łatwe do wysłania i przetestowania Pobieranie próbek za pomocą głowicy skanującej, bezpośrednio wprowadzany impuls miernika elektronicznego lub ręczna kalibracja przełącznika Może być podłączony do zewnętrznej skrzyni ładunkowej prądu i obsługiwać symulowane obciążenie Test licznika energii 1-fazowej, nr referencyjny Katalog EMR 1 to najnowocześniejszy przenośny jednofazowy licznik energii do testowania i kalibracji liczników energii . EMR 1 to łatwe w użyciu i lekkie urządzenie. EMR 1 ma dokładność 0,3% Specyfikacje 1. Sprawdź błędy miernika bez odłączania zasilania. 2. Opcjonalna atrapa skrzyni ładunkowej 3. Certyfikat: ISO 9001 Features Specjalna obudowa z tworzywa sztucznego, lekka i łatwa do przenoszenia, wyświetlacz LCD Zmierz napięcie, prąd, moc. fazowy współczynnik mocy bez rozłączania obwodu mocy Sprawdź dodatni/ujemny błąd miernika fazy bez odłączania obwodu zasilania Szeroki zakres cęgów prądowych: 0,5-100A Szeroki zakres napięcia roboczego: AC180 - 250V Zasilanie dostarczane bezpośrednio przez przewód testowy napięcia Wyjście impulsowe energii o wysokiej i niskiej częstotliwości. Łatwe do wysłania i przetestowania Pobieranie próbek za pomocą głowicy skanującej, bezpośrednio wprowadzany impuls miernika elektronicznego lub ręczna kalibracja przełącznika Może być podłączony do zewnętrznej skrzyni ładunkowej prądu i obsługiwać symulowane obciążenie Test licznika energii 1-fazowej, nr referencyjny Katalog EMR 1 to najnowocześniejszy przenośny jednofazowy licznik energii do testowania i kalibracji liczników energii . EMR 1 to łatwe w użyciu i lekkie urządzenie. EMR 1 ma dokładność 0,3% Specyfikacje 1. Sprawdź błędy miernika bez odłączania zasilania. 2. Opcjonalna atrapa skrzyni ładunkowej 3. Certyfikat: ISO 9001 Features Specjalna obudowa z tworzywa sztucznego, lekka i łatwa do przenoszenia, wyświetlacz LCD Zmierz napięcie, prąd, moc. fazowy współczynnik mocy bez rozłączania obwodu mocy Sprawdź dodatni/ujemny błąd miernika fazy bez odłączania obwodu zasilania Szeroki zakres cęgów prądowych: 0,5-100A Szeroki zakres napięcia roboczego: AC180 - 250V Zasilanie dostarczane bezpośrednio przez przewód testowy napięcia Wyjście impulsowe energii o wysokiej i niskiej częstotliwości. Łatwe do wysłania i przetestowania Pobieranie próbek za pomocą głowicy skanującej, bezpośrednio wprowadzany impuls miernika elektronicznego lub ręczna kalibracja przełącznika Może być podłączony do zewnętrznej skrzyni ładunkowej prądu i obsługiwać symulowane obciążenie Często zadawane pytania ( FAQ ) FAQ about Energy meter testing : 01 What is the purpose of reference testing in energy meter calibration? The purpose of reference testing in energy meter calibration is to verify and ensure the accuracy of the energy meter by comparing its measurements against a highly precise and traceable standard—called the reference meter or standard. This process identifies any measurement errors or deviations in the energy meter under test, allowing for correction or adjustment to meet specified accuracy classes. Reference testing helps maintain measurement reliability, billing fairness, and compliance with industry standards. 02 How is the accuracy class of an energy meter determined during calibration? The accuracy class of an energy meter is determined by evaluating its measurement error under a range of standardized test conditions during calibration. This involves comparing the meter’s energy readings against those of a highly accurate reference standard meter over a set period and at various load levels and power factors. The calibration process typically tests the meter at multiple points such as: Light load (e.g., 10% of rated current) Medium load (e.g., 50% of rated current) Full load (100% of rated current) Additionally, measurements are taken at different power factors, including unity (1.0), lagging (inductive), and leading (capacitive) conditions, to simulate real operating scenarios. At each test point, the percentage error is calculated by comparing the meter’s recorded energy to that of the reference meter. The accuracy class is assigned based on whether these errors stay within the maximum allowable limits defined by standards such as IEC 62053 or ANSI C12.20. For example, a Class 1.0 meter must not exceed ±1% error under these conditions. Consistent performance across all test points confirms the meter’s accuracy class, ensuring it meets the required precision for billing or monitoring applications. 03 Do you know the common standards and regulations followed for energy meter calibration? What are the common standards and regulations followed for energy meter calibration? Energy meter calibration is governed by international and regional standards to ensure accuracy, reliability, and uniformity. The most widely followed standards include: IEC 62053 series: International standards specifying performance and accuracy requirements for different classes of electricity meters (e.g., IEC 62053-21 for static meters, IEC 62053-22 for active energy meters, and IEC 62053-23 for reactive energy meters). IEC 60521 and IEC 60522: Standards covering calibration methods and testing procedures for electric meters. ANSI C12 series: North American standards, such as ANSI C12.20, that define accuracy classes and testing protocols for electric meters. OIML R46: International recommendation by the International Organization of Legal Metrology outlining accuracy requirements and test procedures for electricity meters used in billing. National regulations: Many countries have their own legal metrology regulations and certification requirements to ensure meters used for billing comply with local laws. 04 Do you know which equipment is used as a reference standard during energy meter calibration? The reference standard in energy meter calibration is a highly accurate and traceable device known as a calibration standard meter or reference meter. This equipment has a much higher precision than the meter under test, typically with an accuracy class of 0.02% or better. Common types include: Standard reference meters: Precision static energy meters designed specifically for calibration, with traceability to national or international measurement standards. Calibrated instrument transformers: High-accuracy current and voltage transformers to supply accurate test signals. Precision power sources: Devices that can generate stable and controllable voltage and current at various loads and power factors to simulate real operating conditions. Calibration benches or test rigs: Integrated setups that combine the above equipment to perform automated, controlled calibration tests. Using these reference standards ensures that the energy meter calibration is accurate, repeatable, and compliant with metrology requirements. 05 How do environmental conditions affect energy meter calibration results? Environmental factors like temperature, humidity, and atmospheric pressure can influence the accuracy of energy meter calibration. Temperature: Changes in temperature can affect the electrical characteristics of meter components, causing measurement drift or errors. Most calibration standards specify temperature ranges within which tests should be performed to ensure consistency. Humidity: High humidity can cause condensation or moisture ingress, impacting insulation resistance and electronic circuits, leading to inaccurate readings during calibration. Atmospheric pressure: Variations in pressure can subtly affect electrical properties, especially in sensitive equipment, although its impact is generally less significant than temperature or humidity. To minimize these effects, calibrations are ideally conducted in controlled laboratory environments with stable temperature and humidity, or environmental conditions are recorded and accounted for in the calibration report. 06 What is the difference between static and dynamic energy meter calibration? Static calibration tests the energy meter under steady-state conditions by applying fixed voltage and current values at set loads and power factors. It measures the meter’s accuracy when the electrical parameters remain constant, helping to verify basic performance and error under controlled, stable conditions. Dynamic calibration, on the other hand, evaluates the meter’s performance under varying, real-world operating conditions where voltage, current, and load fluctuate over time. It simulates actual usage patterns to assess how accurately the meter records energy during transient events, load changes, and power quality variations. While static calibration is simpler and faster, dynamic calibration provides a more comprehensive assessment of meter accuracy in practical scenarios, especially important for modern smart meters and complex electrical systems. 07 How often should energy meters be recalibrated to ensure accuracy? Energy meters should typically be recalibrated every 3 to 5 years, depending on regulatory requirements, manufacturer recommendations, and the operating environment. Frequent recalibration helps detect any drift in accuracy caused by aging, environmental factors, or mechanical wear. In critical applications or harsh conditions, more frequent recalibration may be necessary. Utilities often follow national standards or legal metrology guidelines that specify maximum intervals to maintain measurement reliability and billing fairness. 08 What is the process for checking the linearity of an energy meter? Checking the linearity of an energy meter involves verifying that the meter’s measurement error remains consistent across a wide range of loads. The process includes: Apply multiple test currents: The meter is tested at different load levels, typically ranging from low (e.g., 10% of rated current) to full load (100%) and sometimes even above. Maintain constant voltage and power factor: During each test point, voltage and power factor are kept steady to isolate the current’s effect. Record meter readings: The energy measured by the meter under test is compared against a reference standard meter at each load level. Calculate percentage error: For each load, the error percentage is calculated based on the difference between the test meter and reference meter readings. Analyze results: A linear meter will show minimal variation in error across all loads. Significant deviations indicate non-linearity, which can affect billing accuracy. This test ensures the meter accurately measures energy consumption regardless of load size, essential for fair billing and reliable performance. 09 How are errors in energy meters identified and corrected during calibration? During calibration, errors in energy meters are identified by comparing the meter’s recorded energy values to those of a highly accurate reference standard under controlled test conditions. The percentage difference between the meter reading and the reference reading reveals the magnitude and direction of the error. If errors exceed acceptable limits defined by standards, corrective actions may include: • Adjustment: For mechanical meters, physical adjustments (like repositioning the dial or adjusting the braking magnet) can reduce errors. • Reprogramming or firmware updates: For electronic meters, software recalibration or parameter tuning may correct measurement deviations. • Component replacement: Faulty parts, such as sensors or electronic modules, may be replaced to restore accuracy. • Rejecting the meter: If the errors cannot be corrected within tolerance, the meter may be deemed unfit for use. After correction, the meter is re-tested to confirm that errors now fall within the required accuracy class, ensuring reliable measurement and billing.

  • Contact Us | KPM Engineering Solutions|Contact Us

    KPM ENGINEERING SOLUTIONS is an electrical test equipment provider with strong support. Our solutions are Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing, Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing, Thermal Imager Camera, PIK, SIK, AC/DC HIPOT. KONTAKT KPM Gurgaon Office : Numer telefonu : +91 124 4001088, Email : sales@kpmtek.com _cc781905-5cde-3194-bb3b- 136bad5cf58d_ ( Centrum sprzedaży i serwisu ) Bangalore Office : Phone Number : +91 8123950553, Email : blr@kpmtek.com _cc781905-5cde-3194-bb3b -136bad5cf58d_ _cc781905-5cde -3194-bb3b-136bad5cf58d_ ( Centrum sprzedaży i serwisu ) EU Contact _cc781905-5cde-3194 -bb3b-136bad5cf58d_ : Phone Number :+48 539438443 , Email : sales@kpmtek.com _cc781905-5cde-3194 -bb3b-136bad5cf58d_ _cc781905 -5cde-3194-bb3b-136bad5cf58d_ ( Sprzedaż i pomoc techniczna )

  • DCIT | KPM Engineering Solutions Pvt. Ltd.|DCIT ( R & D Initiative )

    KPM Engineering ( A Leading S/S test equipment Company ) and Wellman Power ( A leading CT PT manufacturer ) collaborates to form a Development Center For Instrument Transformers ( DCIT ) with state of art test equipment and standards . It is an initiative to serve power sector @ www.kpmtek.com DCIT - Centrum Rozwoju Transformatorów Instrumentalnych KPM Engineering ( Wiodący sprzęt testowy S/S Company , obsługujący S/S do poziomu 765KV ) _cc781905-5cde-3194-bb3b-136bad5c Producent CT PT do 132KV ) współpracuje, tworząc aCentrum Rozwoju Transformatorów Instrumentalnych ( DCIT ) z najnowocześniejszymi urządzeniami i standardami testowymi. Jest to inicjatywa służąca Power Sector Customers z niezrównaną jakością i precyzją produktów. DCIT koncentruje się na trzech głównych aspektach Instrument Transformers 1) Conductor 2) Insulation_cc781905 -5cde-3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194- bb3b-136bad5cf58d_3) Core Kilka kluczowych obszarów badań i rozwoju w DCIT to -: Charakterystyka napięcia przekładniki przyrządowe w warunkach niesinusoidalnych Zastosowanie instrument transformers in ocena jakości energii Właściwości metrologiczne napięcia i prądu instrument transformers w pomiarach harmonicznych Wykrywanie i korekcja błędów systematycznych w transformatorach instrument Skontaktuj się z nami

  • Earth Testing | KPM Engineering Solutions Pvt. Ltd.|Earth Testing

    In KPM Engineering Solutions we have all type of state of art earth resistance testers such as Spike Method , Clamp On Method , Grid Earth Resistance Monitor Etc. |Earth Testing |https://www.kpmtek.com/earth-testing-app BADANIE UZIEMIENIA / UZIEMIENIA Tester uziemienia - Metoda Spike Wiedzieć więcej Earth Tester (Spike Method) KPM -ET30K Earth Resistance & Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage &_cc781905-5cde-3194-bb3b- 136bad5cf58d_Napięcie AC. ET30K adopts the latest technology for precise 4-pole, 3 -pole and simple 2-pole measurement for earth odporność. importing FFT and AFC technology,_cc781905-5cde- 3194-bb3b-136bad5cf58d_ with a unique function of anti-interference capability and the ability to adapt to the_cc781905-5cde-3194- bb3b-136bad5cf58d_ environment, consistency of repeat testing,_cc781905-5cde-3194-bb3b -136bad5cf58d_ aby zapewnić wysoką precyzję, wysoką stabilność i niezawodność podczas długotrwałych pomiarów Tester uziemienia — metoda cęgowa Wiedzieć więcej Clamp Earth Tester (KPM-CET1200) is szeroko stosowany w pomiarach rezystancji uziemienia, loop pomiar rezystancji w dziedzinach takich jak electric_cc781905-5cde-3194-bb3b-136 , pole naftowe, architektura i przemysłowy sprzęt elektryczny itp. Podczas pomiaru systemu uziemienia za pomocą pętli nie ma potrzeba odłączenia uziemienia Drut bez pomocniczej electrode, co oznacza bezpieczniejsze i szybsze. Najważniejsze dane techniczne testera uziemienia Clamp (KPM-CET1200) Mierzy rezystancję uziemienia/rezystancję pętli Duży rozmiar szczęki (65 mm x 32 mm) Szeroki zakres pomiaru rezystancji (0,01 Ω do 1200 Ω) Szeroki zakres pomiaru prądu (0,01A do 20A) Idealny do testowania wzajemnie połączonych obwodów uziemiających, takich jak Uziemienie siatki, uziemienie siatki, uziemienie wieży transmisyjnej Tester uziemienia - Metoda Spike Wiedzieć więcej Earth Tester (Spike Method) KPM -ET30K Earth Resistance & Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage &_cc781905-5cde-3194-bb3b- 136bad5cf58d_Napięcie AC. ET30K adopts the latest technology for precise 4-pole, 3 -pole and simple 2-pole measurement for earth odporność. importing FFT and AFC technology,_cc781905-5cde- 3194-bb3b-136bad5cf58d_ with a unique function of anti-interference capability and the ability to adapt to the_cc781905-5cde-3194- bb3b-136bad5cf58d_ environment, consistency of repeat testing,_cc781905-5cde-3194-bb3b -136bad5cf58d_ aby zapewnić wysoką precyzję, wysoką stabilność i niezawodność podczas długotrwałych pomiarów Tester uziemienia online (GERM) Wiedzieć więcej Najnowocześniejsze urządzenie do monitorowania online stanu krytycznego systemu uziemienia Monitor rezystancji uziemienia sieci (Germ ) to stan urządzenia art, które Online monitoruje w czasie rzeczywistym wartość rezystancji uziemienia dołów uziemiających i uruchamia alarm, gdy wykryje jakąkolwiek awarię . Wszystkie informacje z witryny są bezpiecznie przesyłane na serwer za pomocą zaawansowanych metod komunikacji. Często zadawane pytania ( FAQ ) FAQ about Earth testing : 01 Difference between Clamp and Spike Method? Earth Resistance Testing: Clamp vs. Spike Method : The Clamp Method and the Spike (Fall-of-Potential) Method are two commonly used techniques for measuring earth resistance, each with distinct use cases. The Spike Method (also known as the three-point or fall-of-potential method) is considered the most accurate and is typically used during installation or scheduled maintenance when it’s feasible to disconnect the grounding system. It requires driving two auxiliary spikes into the ground at set distances from the earth electrode and measuring the voltage drop created by a test current. This method provides a true earth resistance value but is time-consuming, invasive, and requires open ground access. In contrast, the Clamp Method (or Stakeless method) is a quick, non-intrusive test ideal for live systems where disconnecting the earth rod is not possible. Using a special clamp meter, the method induces a test signal and measures current flow through parallel earth paths. It’s convenient and fast but is only applicable when multiple grounding paths exist (e.g., in mesh or grid systems). The Clamp Method does not provide accurate results for isolated earth rods or when there is only a single grounding point. In summary, the Spike Method is best for accurate baseline testing during commissioning, while the Clamp Method is ideal for routine checks on operational systems without disrupting service. 02 How to Ensure Compliance With Earth Testing in Renewable Sites? Ensuring Compliance with Earth Testing in Renewable Sites : To ensure safety and meet regulatory standards in solar, wind, or hybrid renewable energy systems, proper earth resistance testing is essential. Key Steps: Follow Standards: Comply with IEC 60364, IEEE 80, BS 7430, or local codes. Test Soil Early: Conduct soil resistivity surveys during design to select the right grounding method. Use Proper Methods: Apply the Fall-of-Potential method for commissioning and Clamp Method for periodic checks. Keep Records: Log all test data with method, instrument, and environmental details. Test Regularly: Schedule annual or biannual resistance tests to catch degradation early. Use Remote Monitoring (if available): SCADA or sensors can track resistance levels continuously. Train Personnel: Ensure field staff know correct testing procedures and safety protocols. Third-Party Verification: For audits or large projects, use certified inspectors for compliance reporting. 03 What will be seasonal Impact on Ground Resistance Measurements? Seasonal Impact on Ground Resistance Measurements Ground resistance values can vary significantly with seasonal changes due to environmental factors affecting soil conditions: Soil Moisture: During wet seasons (rainy or winter), soil moisture increases, lowering ground resistance by improving conductivity. Conversely, dry seasons cause soil to dry out, increasing resistance. Soil Temperature: Colder temperatures can increase soil resistivity as water in soil may freeze, reducing conductivity. Warmer temperatures generally improve conductivity. Soil Composition Changes: Seasonal changes in organic matter decomposition and salt concentration may also affect soil resistivity. Vegetation and Ground Cover: Plant growth during certain seasons can affect soil moisture retention and contact with grounding electrodes. Implications Testing during different seasons may yield varying results; hence, baseline measurements should be taken in both dry and wet conditions to understand worst-case scenarios. For accurate monitoring and compliance, schedule tests consistently or adjust acceptable resistance thresholds based on seasonal variation.

  • Monitoring Solutions | KPM Engineering Sol.|Monitoring Tester

    Our monitoring solutions consist of Online power cable temperature monitoring using optical sensors, Online cable partial discharge monitoring, Online Earth Resistance Monitoring etc. MONITOROWANIE PD I UZIEMIENIA ONLINE Penta PD - Detektor wyładowań niezupełnych Wiedzieć więcej Detektor wyładowań niezupełnych Penta PD Detektor wyładowań niezupełnych Penta-PD jest idealnym partnerem w programach konserwacji opartych na stanie. Detektor wyładowań niezupełnych Penta-PD łączy w sobie wszystkie 5 typów technologii czujników wyładowań niezupełnych online. Informacje z wielu czujników zapewniają detektorowi wyładowań niezupełnych Penta-PD wszechstronność wykrywania różnych typów wyładowań niezupełnych w różnych urządzeniach podstacji. Szerokość pasma wykrywania 1.TEV — przejściowe napięcie uziemienia, zakres 3~100 MHz 2.UHF-ultra wysoka częstotliwość 300MHz ~ 2000 MHz 3.UA – Ultradźwiękowy 40 ~ 200 KHz Zakres pomiarowy 1. UA: -90 ~ 80dB 2.TEV: -80~10dBm 3. UHF: -80 ~ 10dBm. Czujnik: a) Czujnik ultradźwiękowy: 20~200(kHz); b) czujnik EV (przejściowe napięcie uziemienia): 5 ~ 100 MHz; c) Czujnik UHF: 300~2000(MHz), z kierunkową charakterystyką odbioru. Penta PD - Detektor wyładowań niezupełnych Wiedzieć więcej Detektor wyładowań niezupełnych Penta PD Detektor wyładowań niezupełnych Penta-PD jest idealnym partnerem w programach konserwacji opartych na stanie. Detektor wyładowań niezupełnych Penta-PD łączy w sobie wszystkie 5 typów technologii czujników wyładowań niezupełnych online. Informacje z wielu czujników zapewniają detektorowi wyładowań niezupełnych Penta-PD wszechstronność wykrywania różnych typów wyładowań niezupełnych w różnych urządzeniach podstacji. Szerokość pasma wykrywania 1.TEV — przejściowe napięcie uziemienia, zakres 3~100 MHz 2.UHF-ultra wysoka częstotliwość 300MHz ~ 2000 MHz 3.UA – Ultradźwiękowy 40 ~ 200 KHz Zakres pomiarowy 1. UA: -90 ~ 80dB 2.TEV: -80~10dBm 3. UHF: -80 ~ 10dBm. Czujnik: a) Czujnik ultradźwiękowy: 20~200(kHz); b) czujnik EV (przejściowe napięcie uziemienia): 5 ~ 100 MHz; c) Czujnik UHF: 300~2000(MHz), z kierunkową charakterystyką odbioru. Analizator PQ Light Wiedzieć więcej Model KPM PQ Light 1) Typ elementu produktu Ręczny wielofazowy miernik mocy 2) Opis faz 3PH4W (bez In) 3PH3W 1PH2W (LN); 1PH2W(LLN);1PH3W(LLN) 3. Zastosowanie urządzenia • Analiza mocy • Licznik energii 4. Typ wejścia • Zewnętrzna cewka Rogowskiego • Zewnętrzny CT (tylko 333mV) 5. Wyświetl 3,5-calowy ekran TFT 6. Częstotliwość próbkowania 8k próbek na sekundę 7. Harmoniczna 52. Maks 8. Właściwości mechaniczne • Waga 350g • Wymiar dł.*szer.*gł.: 21,5*10*3,5 CM Analizator PQ + Wiedzieć więcej Model KPM PQ Light 1) Typ elementu produktu Ręczny wielofazowy miernik mocy 2) Opis fazy 3PH4W (z In) 3PH3W 1PH2W (LN); 1PH2W(LLN);1PH3W(LLN) 3. Zastosowanie urządzenia • Analiza mocy • Licznik energii 4. Typ wejścia • Zewnętrzna cewka Rogowskiego • Zewnętrzny CT (tylko 333mV) 5. Wyświetl 3,5-calowy ekran TFT 6. Częstotliwość próbkowania 8k próbek na sekundę 7. Harmoniczna 52. Maks 8. Łączność z komputerem 8. Właściwości mechaniczne • Waga 350g • Wymiar dł.*szer.*gł.: 21,5*10*3,5 CM Analizator PQ + Wiedzieć więcej Model KPM PQ Light 1) Typ elementu produktu Ręczny wielofazowy miernik mocy 2) Opis fazy 3PH4W (z In) 3PH3W 1PH2W (LN); 1PH2W(LLN);1PH3W(LLN) 3. Zastosowanie urządzenia • Analiza mocy • Licznik energii 4. Typ wejścia • Zewnętrzna cewka Rogowskiego • Zewnętrzny CT (tylko 333mV) 5. Wyświetl 3,5-calowy ekran TFT 6. Częstotliwość próbkowania 8k próbek na sekundę 7. Harmoniczna 52. Maks 8. Łączność z komputerem 8. Właściwości mechaniczne • Waga 350g • Wymiar dł.*szer.*gł.: 21,5*10*3,5 CM Penta PD - Detektor wyładowań niezupełnych Wiedzieć więcej Detektor wyładowań niezupełnych Penta PD Detektor wyładowań niezupełnych Penta-PD jest idealnym partnerem w programach konserwacji opartych na stanie. Detektor wyładowań niezupełnych Penta-PD łączy w sobie wszystkie 5 typów technologii czujników wyładowań niezupełnych online. Informacje z wielu czujników zapewniają detektorowi wyładowań niezupełnych Penta-PD wszechstronność wykrywania różnych typów wyładowań niezupełnych w różnych urządzeniach podstacji. Szerokość pasma wykrywania 1.TEV — przejściowe napięcie uziemienia, zakres 3~100 MHz 2.UHF-ultra wysoka częstotliwość 300MHz ~ 2000 MHz 3.UA – Ultradźwiękowy 40 ~ 200 KHz Zakres pomiarowy 1. UA: -90 ~ 80dB 2.TEV: -80~10dBm 3. UHF: -80 ~ 10dBm. Czujnik: a) Czujnik ultradźwiękowy: 20~200(kHz); b) czujnik EV (przejściowe napięcie uziemienia): 5 ~ 100 MHz; c) Czujnik UHF: 300~2000(MHz), z kierunkową charakterystyką odbioru. Penta PD - Detektor wyładowań niezupełnych Wiedzieć więcej Detektor wyładowań niezupełnych Penta PD Detektor wyładowań niezupełnych Penta-PD jest idealnym partnerem w programach konserwacji opartych na stanie. Detektor wyładowań niezupełnych Penta-PD łączy w sobie wszystkie 5 typów technologii czujników wyładowań niezupełnych online. Informacje z wielu czujników zapewniają detektorowi wyładowań niezupełnych Penta-PD wszechstronność wykrywania różnych typów wyładowań niezupełnych w różnych urządzeniach podstacji. Szerokość pasma wykrywania 1.TEV — przejściowe napięcie uziemienia, zakres 3~100 MHz 2.UHF-ultra wysoka częstotliwość 300MHz ~ 2000 MHz 3.UA – Ultradźwiękowy 40 ~ 200 KHz Zakres pomiarowy 1. UA: -90 ~ 80dB 2.TEV: -80~10dBm 3. UHF: -80 ~ 10dBm. Czujnik: a) Czujnik ultradźwiękowy: 20~200(kHz); b) czujnik EV (przejściowe napięcie uziemienia): 5 ~ 100 MHz; c) Czujnik UHF: 300~2000(MHz), z kierunkową charakterystyką odbioru. Analizator PQ + Wiedzieć więcej Model KPM PQ Light 1) Typ elementu produktu Ręczny wielofazowy miernik mocy 2) Opis fazy 3PH4W (z In) 3PH3W 1PH2W (LN); 1PH2W(LLN);1PH3W(LLN) 3. Zastosowanie urządzenia • Analiza mocy • Licznik energii 4. Typ wejścia • Zewnętrzna cewka Rogowskiego • Zewnętrzny CT (tylko 333mV) 5. Wyświetl 3,5-calowy ekran TFT 6. Częstotliwość próbkowania 8k próbek na sekundę 7. Harmoniczna 52. Maks 8. Łączność z komputerem 8. Właściwości mechaniczne • Waga 350g • Wymiar dł.*szer.*gł.: 21,5*10*3,5 CM Analizator PQ + Wiedzieć więcej Model KPM PQ Light 1) Typ elementu produktu Ręczny wielofazowy miernik mocy 2) Opis fazy 3PH4W (z In) 3PH3W 1PH2W (LN); 1PH2W(LLN);1PH3W(LLN) 3. Zastosowanie urządzenia • Analiza mocy • Licznik energii 4. Typ wejścia • Zewnętrzna cewka Rogowskiego • Zewnętrzny CT (tylko 333mV) 5. Wyświetl 3,5-calowy ekran TFT 6. Częstotliwość próbkowania 8k próbek na sekundę 7. Harmoniczna 52. Maks 8. Łączność z komputerem 8. Właściwości mechaniczne • Waga 350g • Wymiar dł.*szer.*gł.: 21,5*10*3,5 CM Analizator PQ + Wiedzieć więcej Model KPM PQ Light 1) Typ elementu produktu Ręczny wielofazowy miernik mocy 2) Opis fazy 3PH4W (z In) 3PH3W 1PH2W (LN); 1PH2W(LLN);1PH3W(LLN) 3. Zastosowanie urządzenia • Analiza mocy • Licznik energii 4. Typ wejścia • Zewnętrzna cewka Rogowskiego • Zewnętrzny CT (tylko 333mV) 5. Wyświetl 3,5-calowy ekran TFT 6. Częstotliwość próbkowania 8k próbek na sekundę 7. Harmoniczna 52. Maks 8. Łączność z komputerem 8. Właściwości mechaniczne • Waga 350g • Wymiar dł.*szer.*gł.: 21,5*10*3,5 CM Często zadawane pytania ( FAQ ) FAQ about Monitoring testing : 01 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? • Using both TEV and ultrasonic methods together enhances diagnostic accuracy: • • TEV gives insight into internal discharge severity and location. • • Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. • • This dual-method approach is vital for: • • Preventive maintenance, • • Avoiding insulation failures, • • Improving switchgear reliability, and • • Extending equipment life without needing shutdowns.

  • advertisements | KPM Engineering Solutions Pvt. Ltd.|Gallery

    In KPM Engineering Solution Pvt. Ltd our solutions are Thermal Imager camera, fever monitoring solution, Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing , Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing. Visit www.kpmtek.com for details Galeria wideo Photos Videos Anchor 1 Galeria wideo Load More Galeria wideo All Videos All Videos Odtwórz Wideo Udostępnienia Cały kanał Ten film Facebook Twitter Pinterest Tumblr Skopiuj link Link skopiowany Search videos Wyszukaj film... Teraz Odtwarzane KPM KFA320 00:35 Odtwórz Wideo Teraz Odtwarzane KPM intro (M) 01:16 Odtwórz Wideo Teraz Odtwarzane KPM India - Your Reliable Electrical Test Equipment Solution Provider 01:20 Odtwórz Wideo Anchor 2

  • Automatic Relay Test Kits | KPM solutions|Relay Testing

    KPM relay testing equipment with high current rating, precision & advanced software. Ideal for distance, differential, df/dt & protection relay testing. UNIWERSALNY ZESTAW DO TESTOWANIA PRZEKAŹNIKÓW KF86 P , (6I, 6V i IEC 61850) 10Kg Blog techniczny KF 86P to zaawansowany, wydajny i bardzo dokładny zestaw do automatycznego testowania przekaźników, idealny do wszelkiego rodzaju aplikacji do testowania przekaźników. Wysoka moc znamionowa i wysoki prąd znamionowy Idealny zestaw do testowania przekaźników do testowania przekaźników elektromechanicznych High Buden Lekki i najnowocześniejszy projekt (tylko 10 kg) Najnowocześniejsze oprogramowanie (ze wszystkimi zaawansowanymi funkcjami) do testowania przekaźników numerycznych Zgodne z IEC61850-9-1, IEC61850-9-2, IEC60044-7/8 itp. (opcjonalnie) Cechy sprzętowe uniwersalnego zestawu do testowania przekaźników (KF86P): Six niezależne źródła napięcia AC 0-310V @ 105VA każde. Six niezależne źródła prądowe of 0 - 35A @ 425 VA każde . Jedno niezależne pomocnicze źródło prądu stałego 14~ 300V . Wyjścia analogowe o wysokiej dokładności <0,15%rd + 0,05%rg,Guar. Nadaje się do testowania przekaźników numerycznych i elektromechanicznych Testowanie przetwornika i licznika energii (opcjonalnie w zestawie do testowania przekaźników) KFA 300 , (3I i 3U), 3 Kg Blog techniczny Wyjątkowa propozycja: Najlżejszy zestaw do testowania przekaźników < 3 kg z analogiem o/ps Źródła prądowe: 3 X 10 A Źródła napięcia: 3 X 265 V Wbudowany wyświetlacz i bateria Idealny do testowania przekaźników numerycznych i statycznych Funkcja oprogramowania Funkcja ręcznego/automatycznego testu AC Funkcja testu sekwencera stanów Funkcja testera wyłącznika nadprądowego Funkcja zdalna (sygnał, pomiar, kontrola). Funkcja zdalnego testu sygnału Zestaw do testowania przekaźników — K3063I (6I i 4 U) Blog techniczny K3063i to zaawansowany i wydajny zestaw do automatycznego testowania przekaźników, idealny do testowania uniwersalnych przekaźników Wysoka moc znamionowa i wysoki prąd znamionowy Idealny do testowania przekaźników High Buden Electro-mechanical Lekki i najnowocześniejszy projekt (tylko 17 kg) State of Art Software (ze wszystkimi zaawansowanymi funkcjami) do testowania przekaźników numerycznych Funkcje sprzętowe of Universal Relay Test Kit (K3063i): Cztery niezależne źródła napięcia AC 0-310V @ 124VA każde. Six niezależne źródła prądu of 0-35A @ 480 VA każde . Jedno niezależne pomocnicze źródło prądu stałego o napięciu 14~ 350 V przy 140 VA. Wyjścia analogowe o wysokiej dokładności <0,15%rd + 0,05%rg,Guar. Nadaje się do testowania przekaźników numerycznych i elektromechanicznych Testowanie licznika energii (opcjonalnie) KFA 300 , (3I i 3U), 3 Kg Blog techniczny Wyjątkowa propozycja: Najlżejszy zestaw do testowania przekaźników < 3 kg z analogiem o/ps Źródła prądowe: 3 X 10 A Źródła napięcia: 3 X 265 V Wbudowany wyświetlacz i bateria Idealny do testowania przekaźników numerycznych i statycznych Funkcja oprogramowania Funkcja ręcznego/automatycznego testu AC Funkcja testu sekwencera stanów Funkcja testera wyłącznika nadprądowego Funkcja zdalna (sygnał, pomiar, kontrola). Funkcja zdalnego testu sygnału Zestaw do testowania przekaźników - K3163i (6I i 4U oraz IEC 61850) Blog techniczny K3163i+ to zaawansowany, wydajny i bardzo dokładny zestaw do automatycznego testowania przekaźników Wysoka moc znamionowa i wysoki prąd znamionowy Idealny zestaw do testowania przekaźników do testowania przekaźników High Buden Electro-mechanical Relays Lekki i najnowocześniejszy projekt (tylko 17 kg) State of Art Software (ze wszystkimi zaawansowanymi funkcjami) do testowania przekaźników numerycznych Zgodne z IEC61850-9-1, IEC61850-9-2, IEC60044-7/8 itp. (opcjonalnie) Funkcje sprzętowe of Universal Relay Test Kit (K3163i): Cztery niezależne źródła napięcia AC 0-310V @ 124VA każde. Six niezależne źródła prądowe of 0 - 35A @ 480 VA każde . Jedno niezależne pomocnicze źródło prądu stałego o napięciu 14~ 350 V przy 140 VA. Wyjścia analogowe o wysokiej dokładności <0,15%rd + 0,05%rg,Guar. Nadaje się do testowania przekaźników numerycznych i elektromechanicznych Testowanie przetwornika i licznika energii (opcjonalny zestaw testowy in relay ) Zestaw do testowania przekaźników — K68I (3I i 4 U) Blog techniczny K68i to potężny i solidny zestaw do testowania przekaźników do półautomatycznego i ręcznego testowania przekaźników. Funkcje sprzętowe of Zestaw do testowania przekaźników K68i: Tester przekaźników typu „wszystko w jednym” z wyświetlaczem LCD o przekątnej 6,4 cala. Cztery niezależne źródła napięcia AC 0-300V @ 110VA każde. Three niezależne źródła prądu of 0-35A @ 450 VA każde . Jedno niezależne pomocnicze źródło prądu stałego 0 ~ 300 V/0,6 A. Wyjścia analogowe o wysokiej dokładności <0,15%rd + 0,05%rg,Guar. Port kompatybilny z projektorem dla cel szkolenia i nauki . Wytrzymała konstrukcja z enkoderem obrotowym o bardzo długiej żywotności + funkcjonalna klawiatura. Funkcje oprogramowania of Universal Relay Test Kit K68i: Możliwość testowania większości przekaźników w trybie ręcznym lub półautomatycznym - Przekaźniki napięciowe, przekaźniki prądowe, przekaźniki częstotliwości, przekaźniki mocy, przekaźniki impedancji, przekaźniki harmoniczne, przekaźniki dystansowe itp. Z samodzielną obudową i funkcją wykrywania uziemienia Video Relay Test Kit Filmy — zestawy testowe przekaźników Relay Test Kit Videos Relay Test Kit Videos Odtwórz Wideo Udostępnienia Cały kanał Ten film Facebook Twitter Pinterest Tumblr Skopiuj link Link skopiowany Search videos Wyszukaj film... Teraz Odtwarzane KPM KFA320 00:35 Odtwórz Wideo Teraz Odtwarzane Random check on K3063i universal relay test kit with fluke 6.5 digit multimeter . 01:10 Odtwórz Wideo Teraz Odtwarzane KFA 300 , Lightest Relay Test Kit ( 3.5 KG ) 07:29 Odtwórz Wideo Teoria - Testowanie przekaźników Theory -Relay Test Kit Zestaw do testowania przekaźników – Teoria Przekaźnik ochronny to urządzenie, które utrzymuje urządzenia systemu zasilania i daje wyjście w nienormalnym stanie, aby zapewnić ochronę systemu. Podstawowym celem przekaźnika ochronnego jest jak najszybsze odizolowanie wadliwej sekcji w systemie elektroenergetycznym, aby reszta systemu działała normalnie. Konieczne jest zapewnienie bezpieczeństwa, niezawodności, jakości, czułości i szybkości przekaźników. W normach krajowych i międzynarodowych zalecane są różne testy w celu sprawdzenia wytrzymałości przekaźnika w warunkach awarii. Podczas testowania przekaźnik ochronny jest poddawany symulowanym warunkom polowym w celu sprawdzenia jego działania. Odpowiednie normy krajowe/międzynarodowe zalecają przeprowadzenie wielu testów w celu sprawdzenia skuteczności przekaźników w wykonywaniu ich zamierzonej funkcji. Przekaźnik odbiera sygnały wejściowe z CT/PT, a jego program oblicza warunki błędu zgodnie z aplikacją. Wysyła polecenie wyłączenia do wyłącznika po wykryciu usterki. Na podstawie zastosowania przekaźnik można podzielić na następujące typy: Krok 1: Zestaw do testowania przekaźników wprowadza błąd w postaci I i V do odpowiednich punktów CT i PT przekaźnika under test . Licznik czasu zestawu do testowania przekaźników rozpoczyna się od zainicjowania wstrzyknięcia fault. Krok 2: Przekaźnik wykrywa usterkę i wydaje polecenie wyłączenia, czas jego wyłączenia musi zależeć od charakterystyki czasowej ustawień przekaźnika. Krok 3: Zestaw do testowania przekaźników odbiera polecenie wyłączenia z przekaźnika i zatrzymuje timer. Krok 4: Zmierzone charakterystyki wyzwalania są porównywane z oczekiwanym wyzwalaniem zgodnie z ustawieniami Inżyniera. Podstawowe podłączenie przekaźnika zabezpieczeniowego pokazano na rysunku. Wtórne uzwojenie przekładnika prądowego jest podłączone do cewki prądowej przekaźnika. Uzwojenie wtórne przekładnika napięciowego jest podłączone do cewki napięciowej przekaźnika. Ilekroć wystąpi jakakolwiek usterka w obwodzie zasilającym, proporcjonalny prąd wtórny przekładnika prądowego przepłynie przez cewkę prądową przekaźnika, dzięki czemu mmf tej cewki wzrośnie. To zwiększone mmf jest wystarczające do mechanicznego zamknięcia normalnie otwartego styku przekaźnika. Ten styk przekaźnika faktycznie zamyka i zamyka obwód cewki wyzwalającej DC, a zatem cewka wyzwalająca jest zasilana. Mf cewki wyzwalającej inicjuje ruch mechaniczny mechanizmu wyzwalającego wyłącznika i ostatecznie wyłącznik zostaje wyzwolony w celu odizolowania usterki. Typy przekaźników zgodnie z różnymi wymaganiami: Differential Relay Over Current Relay Aktywowany częstotliwością Relay Nadmierny prąd kierunkowy Relay Ograniczone zwarcie doziemne Relay Over Fluxing Relay Schematy odległości Relay Szyna zbiorcza Protection Relay Odwrotna moc Relay Utrata wzbudzenia Relay Ujemna sekwencja Ph. Relay Liczniki energii Relay Przetworniki Relay Błąd odtwarzania Relay Często zadawane pytania FAQ-RTK FAQ about all our Relay testing products 01 Co to jest zestaw do testowania przekaźników? Zestaw do testowania przekaźników to sprzęt, który służy do testowania różnych typów przekaźników. Zestaw do testowania przekaźników to połączenie programowalnych źródeł prądowych i napięciowych oraz timera. Podczas testowania przekaźnika Zestaw testowy przekaźnika wprowadza błąd do przekaźnika (w postaci CT i PT) i mierzy czas wyzwolenia lub czas reakcji przekaźnika. Jeśli zachowanie przekaźnika jest zgodne z jego ustawieniami, przekaźnik przechodzi test, w przeciwnym razie przekaźnik nie przejdzie testu. 02 Dlaczego automatyczne zestawy do testowania przekaźników są preferowane w porównaniu z tradycyjnymi (opartymi na wariantach) zestawami do testowania przekaźników? Zestawy do testów automatycznych przekaźników mają wiele zalet w porównaniu z tradycyjnymi testami dla dzieci 1. Stabilność sygnału: Wyjście prądu i napięcia wyjściowego zestawu do automatycznego testowania przekaźników nie jest proporcjonalne do jego zasilania wejściowego, co oznacza, że wyjście prądowe i napięciowe zestawu do testowania przekaźników jest zasilane z sygnału analogowego na cyfrowy, a następnie konwersja cyfrowa na analogowa wspierana przez pętla sprzężenia zwrotnego, stąd sygnały wyjściowe z zestawu testowego przekaźnika nie są zależne od jego zasilania wejściowego. Wyjście automatycznego zestawu do testowania przekaźników jest stabilne, nawet jeśli występuje niewielka niestabilność zasilania wejściowego 2. Dokładność, rozdzielczość i funkcjonalność: Za pomocą automatycznych zestawów do testowania przekaźników użytkownik może niezależnie zmieniać częstotliwość faz i wielkość wszystkich sygnałów prądowych i napięciowych z bardzo wysoką rozdzielczością i dokładnością. Nie jest to możliwe w tradycyjnych zestawach do wstrzykiwania wtórnego, które mogą zwiększać lub zmieniać tylko wielkość ( V lub I ) za pomocą ręcznej zmiany. 03 Co to jest zestaw do testowania przekaźników numerycznych? Zestaw do testowania przekaźników numerycznych to inna nazwa automatycznych lub opartych na mikroprocesorach zestawów do testowania przekaźników. Przekaźniki numeryczne generalnie charakteryzują się wysoką dokładnością, którą można przetestować za pomocą bardzo dokładnych automatycznych zestawów do testowania przekaźników 04 Co to jest uniwersalny zestaw do testowania przekaźników? Uniwersalny zestaw do testowania przekaźników to inna nazwa automatycznych zestawów do testowania przekaźników, ponieważ użytkownik może niezależnie zmieniać fazę, częstotliwość i wielkość źródeł prądu i napięcia oraz generować wszelkiego rodzaju usterki. 05 Co to jest zestaw testowy przekaźnika 6-fazowego, gdy w systemie zasilania jest tylko 3-fazowy CT lub PT? Wielu klientów jest zdezorientowanych oznaczeniem zestawu testowego przekaźnika 6-fazowego. Wysokiej klasy zestawy do testowania przekaźników mają sześć źródeł prądu, których częstotliwość fazową i wielkość można zmieniać niezależnie. Te 6 źródeł prądu jest bardzo przydatnych w testowaniu przekaźników różnicowych. 06 Jakie jest zapotrzebowanie na zaawansowane oprogramowanie z automatycznymi zestawami do testowania przekaźników? Ponieważ wiemy, że każda usterka jest generowana w wyniku zmiany fazy, częstotliwości lub wielkości w sygnale CT lub PT, kilka symulacji usterek nie jest bardzo prostych (jak testowanie charakterystyki czworobocznej przekaźników odległościowych). Oprogramowanie Advance jest bardzo przydatne w symulowaniu złożonych usterek. Użytkownik Kingsine otrzymuje wszystko w jednym zaawansowanym oprogramowaniu w ramach standardowego zakupu . 07 Dlaczego wzmacniacze wysokiego napięcia i prądu są pożądane w zestawach do testowania przekaźników Prawdziwie mówi się, że źródła prądu i napięcia są duszą zestawu do testowania przekaźników. Sygnał o wysokim prądzie i napięciu jest przydatny na poniższe sposoby 1. Aby przetestować przekaźniki nadprądowe 5A 10 razy, musimy wstrzyknąć 3X50A, co jest możliwe przy użyciu zestawów testowych przekaźników wysokoprądowych 2. Wyższym prądem możemy przetestować przekaźnik różnicowy w wyższym punkcie krzywej BIAS. 3. Dzięki wyższym prądom możemy symulować wyższe błędy w odtwarzaniu błędów przejściowych. Zestawy testowe Kingsine mają źródła o najwyższym prądzie znamionowym od 0 do 35 A każde (przy 450 VA) i od 0 do 300 V każde (124 VA) 08 Dlaczego wzmacniacze dużej mocy są pożądane w zestawach do testowania przekaźników? Preferowane są zestawy do testowania przekaźników ze wzmacniaczami dużej mocy, ponieważ do testowania przekaźników elektromechanicznych wymagana jest duża moc. Również jeśli zestaw do testowania przekaźników ma wyższą moc znamionową, wówczas jego cykl pracy dla niższej mocy znamionowej jest wysoki, stąd bardziej wytrzymała konstrukcja. Kingsine posiada najpotężniejsze źródła prądowe o mocy 480VA (@35A) każde i najpotężniejsze źródła napięciowe o mocy 124VA (@310V) każde 09 Co jest ważniejsze, oprogramowanie Advance czy wydajny sprzęt przy wyborze zestawu do automatycznego testowania przekaźników? Wydajny sprzęt jest najważniejszy dla długoterminowej niezawodności zestawu do testowania przekaźników. Niewiele aplikacji wymaga również źródeł o dużej mocy. Zaawansowane oprogramowanie to narzędzie, które pomaga użytkownikowi w najprostszy sposób przetestować nawet najbardziej złożone przekaźniki. Dlatego w dzisiejszym scenariuszu zestaw do testowania przekaźników będzie połączeniem wysoko ocenianych źródeł i zaawansowanego oprogramowania. K3063i to dobre połączenie dla obu stron 10 Dlaczego zestawy testowe przekaźników Kingsine mają najwyższą moc znamionową na rynku? W Kingsine każde źródło prądu ma 480 VA przy 35 A, a źródło napięcia 124 VA przy 310 V, a więc jest najwyższe na rynku. 11 Dlaczego Kingsine K3063i to najlepsze połączenie mocy i dokładności? K3063i ma źródło napięcia i prądu o dużej mocy (Źródło prądu wynosi 480VA przy 35A, a Źródło napięcia to 124VA przy 310V), a jednocześnie ma zakres prądowy 3 A, co prowadzi do bardzo wysokiej dokładności przy niższych prądach. 12 Z kim się skontaktować w sprawie sprzętu testowego KPM support ? W razie jakichkolwiek pytań prosimy o kontakt z naszym konsultantem technicznym pod adresem Consultant@kpmtek.com. 13 Gdzie znajduje się centrum serwisowe zestawów testowych przekaźników Kingsine w Indiach? Mamy zaawansowane centrum serwisowe w Gurgaon, Haryana ze 100% dostępnością. 14 Co to jest przekaźnik df/dt, czy mogę go przetestować za pomocą zestawów testowych przekaźników Kingsine? Przekaźnik szybkości zmiany częstotliwości (ROCOF lub df/dt) służy do szybkiego zrzucania obciążenia, przyspieszania czasu pracy w sytuacjach nadmiernej lub zbyt niskiej częstotliwości oraz do wykrywania utraty sieci. Przekaźniki ROCOF lub df/dt są szczególnie skuteczne w zatrzymywaniu spadku częstotliwości sieci w przypadku nagłej utraty głównej generacji. Dzieje się tak dlatego, że mierząc szybkość zaniku częstotliwości, działanie naprawcze można zainicjować znacznie wcześniej, niż czas, w którym częstotliwość połączenia synchronicznego faktycznie spadłaby do punktu, w którym przekaźniki podczęstotliwościowe generatora lub urządzenia pomocnicze jednostki wyzwoliłyby się/zadziałały, prowadząc do całkowite wyłączenie systemu. df/dt służy do zrzucania obciążenia w sytuacjach, gdy nagłej utracie mocy wytwórczej w systemie będzie towarzyszyć spadek częstotliwości systemu. W takiej sytuacji niedopasowania generacji obciążenia częstotliwość systemu ma tendencję do spadania. Przekaźnik df/dt może sterować wyłącznikami i umożliwiać odłączanie linii zasilających od sieci, jeden po drugim. W Kingsine Software dostępny jest wyspecjalizowany moduł do testowania df/dt 15 Co to jest przekaźnik odległości, które zestawy do testowania przekaźników mogą testować te przekaźniki? Przekaźnik odległości / przekaźnik impedancji to przekaźnik nadprądowy z ograniczeniem napięcia. Przekaźnik mierzy impedancję do punktu zwarcia i wydaje polecenie wyłączenia, jeśli impedancja ta jest mniejsza niż nastawa przekaźnika Z. Ustawienie przekaźnika Z jest znane jako impedancja repliki i jest proporcjonalne do ustawionej impedancji tj. impedancja do zasięgu przekaźnika . Przekaźnik stale monitoruje prąd linii I przez CT i napięcie szyny V przez PT i działa, gdy stosunek V/I spadnie poniżej ustawionej wartości. W Kingsine zarówno K68i, jak i K3063i mają wyspecjalizowane moduły do testowania przekaźników odległościowych. 16 Dlaczego do testowania przekaźników elektromechanicznych wymagany jest zestaw do testowania przekaźników dużej mocy Przekaźniki elektromechaniczne mają cewki o wysokiej impedancji, podczas testowania zestaw testowy przekaźnika musi podawać prąd przez cewki o wysokiej impedancji, stąd wymagane jest duże obciążenie. Zestawy Kingsine mają największe obciążenie, dlatego idealnie nadają się do testowania wszystkich typów przekaźników. 17 Co to jest zaawansowana funkcja odtwarzania stanu przejściowego zestawu do automatycznego testowania przekaźników? Obecnie wszystkie zaawansowane przekaźniki są wyposażone w funkcję rejestrowania usterek. W przypadku wystąpienia usterki plik ten zostaje zapisany w przekaźniku w postaci pliku .cfg / comtrade . Zestaw do testowania przekaźników ma funkcję importowania tego pliku do swojego oprogramowania i odtwarzania pliku przy użyciu źródeł prądu i napięcia. Nazywa się to funkcją odtwarzania przejściowego. 18 O jakich środkach ostrożności dotyczących połączeń należy pamiętać podczas obsługi zestawu do testowania przekaźników? Kilka środków ostrożności na stronie to -: 1. Wszystkie zaciski CT i PT, które mają być podłączone do zestawu do testowania przekaźników, nie mogą być pod napięciem. 2. Uziemienie powinno być zawsze podłączone do zestawu. 3. Podczas testowania należy unikać stosowania urządzeń o wysokim natężeniu udarowym, takich jak zestawy spawalnicze, w tym samym obwodzie zasilania zestawu do testowania przekaźników. 4. Zawsze pracuj zgodnie z odpowiednimi lokalnymi lub międzynarodowymi standardami testowania. 19 Jakie rodzaje zabezpieczeń występują w zestawach testowych przekaźników automatycznych Kingsine? Zestawy testowe przekaźników Kingsine mają poniższe zabezpieczenia 1. Zabezpieczenie przed zwarciem ma wzmacniacze napięcia 2. Zabezpieczenie obwodu otwartego dla wzmacniaczy prądowych 3. Ochrona przed przegrzaniem . 4. Oznaczenie Zdrowie Ziemi itp. 20 Chcę przetestować przekaźniki różnicowe, który typ zestawu do testowania przekaźników jest dla mnie bardziej odpowiedni? Do testowania przekaźnika różnicowego w trybie 3-fazowym potrzebujemy zestawu testowego przekaźnika 6 źródła prądu, np. K3063i. Przekaźnik różnicowy możemy przetestować międzyfazowo również za pomocą zestawu testowego przekaźnika źródła prądu, K68i

  • Ultra High Voltage Test Equipment | KPM Solutions|Products

    KPM Solutions supplies precision ultra high voltage test equipment including Relay Test Kits, CT/PT Analyzers, TTR, Winding Resistance & PD Testers. Know more SPRZĘT DO TESTOWANIA SYSTEMÓW ZASILAJĄCYCH KPM VIT-100 KPM Vacuum Interrupter Tester KPM ICAL Pro KPM Instrument Calibrator KPM MT 3000 D+ Three phase Reference Standard Energy Meter specially used for energy meter on-site test KPM PSR12 KPM’s Power Signal Recorder 12 KPM TD12 A+ Automatic 12KV Capacitance & Dissipation Factor Test Set KPM TWRT YY 3 Phase Winding Resistance Tester with automatic change of connections Energy Meter Test Benchs 3 phase energy meter test bench for testing energy meters of 0.5 to 0.02 accuracy levels. KPM-SG_70kV, 70mA Cable Testing Surge Generator / Thumper KPM LBVV 240V 110A Battery Discharge Kit (Constant Current , Constant Power) KPM LB4815+ Battery Load Bank , Constant Current, Constant Power , Constant Resistance Mode KPM AL- 80H Battery Pack Air Leak Tester KPM AL- 80L KPM Battery Pack Air Leak Tester KPM CCDB + Series KPM Li Ion Cell Charge Discharge & Balancer KPM CCDB SERIES KPM Li Ion Cell Charge Discharge & Balancer KPM PDH SERIES KPM Pack Discharging (800V / 1000V) KPM PCD Series KPM li Ion Battery Pack Charge Discharge Test kit PCDH Series KPM li Ion Battery Pack Charge Discharge Test kit ( 800V / 1000V ) KPM MCD 2550 KPM charging , discharging & cyclic charging - discharging of Li Ion modules , Constant Current Discharge KPM CCDB 5V 15A KPM Li-ion Cell Charge Discharge Balancing kit, Constant Current Discharge (5V, 15 A) KPM BCD 0550 KPM Li-ion Battery Charging Discharging kit , Constant Current Discharge (5V, 50 A), Used for high current applications like forklifts, cranes etc. KPM BCD 0530 KPM Li-ion Battery Charging Discharging kit (5V, 30A), Constant Current Discharge , Used for high current applications like forklifts, cranes etc. KPM BCD B-4X KPM Li-ion Battery Charging Discharging kit with 4 independent channels (100A), Constant Current Discharge , Used for high current applications like forklifts, cranes etc. KPM KS30 KPM SF6 Gas Analyzer KPM BA-02 Battery Analyzer for testing battery internal resistance, conductance and voltage. Auto increase in the serial number of results using touch and test function, this also reduces testing time KPM Battery Data Logger To check Battery voltage, current and temperature. These sensors are integrated with battery discharge units KPM LA 103 Pro LA Tester measures and displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current directly with ambient temperature and line harmonic compensation KPM ER1 KPM ER1C is the Three phase Reference Standard Energy Meter specially used to calibrate single phase energy meter on-site . KPM AC HIPOT KPM Cable testing KPM VLF Hipot Tester KPM VLF HIGH VOLTAGE TESTER Hipot Tester KPM DC HIPOT KPM DC Hipot Test Set KPM TD 40 KPM 40kV Tan Delta measurement unit used for cable testing KPM VLF Series KPM VLF series with Tan Delta & PD Measurement Facility KPM Penta Pd pro Hand held Partial Discharge Tester with multichannel PD detection functions which can be integrated with multiple sensors like UHF , TEV, HFCT, AE , Contact Acoustic etc. KPM CEST 1800 KPM’s Clamp Earth & Spike Tester KPM CRT 6002G Contact Resistance Tester with single-end and double-end grounding test technology, It is available in 200A & 600A KPM Onload Tap Changer Analyzer Onload Tap Changer Analyzer is testing key parameters of an OLTC such as ,Transient time, Transition waveform, Transition resistance, Synchronization status of three phase. td12 Automatic 12KV Capacitance & Dissipation Factor Test Set with 4 Nos channels for Bushing testing in one test , Built In 10kV - 5mA Diagnostic Insulation Tester KPM APIK Automatic Primary Injection Kit is used for high voltage switch testing, protection system testing and current transformer testing in power system KPM CTA C+ CT Analyzer ( for factory & field applications ) KPM CT/PT Tester pro An automatic device used for testing of instrument transformers (CTs & PTs) by injection of secondary voltage. This is capable of ratio error , phase error , winding resistance, knee point upto 2kV etc. K3063i 6I & 4U - Automatic Relay Test Kit RTK(KPM KFA 300) The Lightest Relay Test Kit with 3 Current Sources & 4 voltage sources . Builtin software with AC Test , DC Test , Frequency Test , Distance Test , Harmonic Test Modules RTK(K316i) Automatic Relay Test Kit ( 6I,4U) KPM-DPM-01 KPM Dew Point Meter K68i Relay test kit 3I & 4U - Automatic Relay Test Kit RTK KPM KF 86P Automatic Relay Test Kit with 6 current and 6 voltages , with advanced software with RIO / XRIO Import function KPM CT/PT analyzer It tests all type of CT/PT as per IEC standards (deal tool for CT/PT Manufacturers & Utility Customers) KPM CT:PT Tester KPM CT PT Testing , Primary Current Method CT PT PRO KPM CT PT Tester , Voltage Ratio Method KPM CT/PT HVCTR High Voltage Current Transformer Ratio Tester measures Key CT parameters of upto 33KV system KPM CT/PT PIK For testing Current Transformer , Circuit Breakers etc. by injecting current in Primary side of CT. Moduler design for transporting easily KPM TD12 KPM 12kV Tan delta Tester / Dissipation Tester KPM TTR3 On-site measurement of DC resistance of transformer or motors (High Current Source of 20 A) KPM SFRA 01 Sweep Frequency Response Analysis Test Set (SFRA) for checking the core and winding integrity of a power transformer KPM TWRT Series On-site measurement of DC resistance of transformer (High Current Source of 20 A) KPM 5KP 5 KV Diagnostic Insulation Tester KPM 5KP+ IR Tester ( 5KV, 10KV, 15KV, 20KV) TPL-Trans Power Loss Tester KPM Transformer Power Loss Analyzer OLTC Analyzer KPM Online Tap Changer Tester KPM CB Analyzer KPM Circuit Breaker Analyzer KPM CBA 01 KPM Circuit Breaker Tester KPM CRT Contact Resistance Tester CBT-01 KPM Circuit Breaker Timer VILA KPM Vacuum Interrupter Life Analyzer KPM Oil BDV 100+ KPM Oil Breakdown Voltage Test Kit KPM Oil BDV 100 A+ KPM Oil Breakdown Voltage Test Kit with variable rate of rise voltage KPM OT-01 CC KPM Flash Point Tester Close Cup KPM OT-01 OC KPM Flash Point Tester Open cup KPM OT 02 KPM Karl Fischer Tester , Moisture in oil tester KPM OT O3 KPM Viscosity Tester KPM OT-05 KPM Oil Acid Value Tester KPM OT01 KPM Oil Tan Delta Furan Tester KPM FT-01 KPM HPLC , Furan Tester KPM IPT 01 KPM Imputiry Particle Tester KPM PCM 01 KPM Petroleum Colorimeter KPM ODT 01 KPM Oil Density Tester KPM Interfacial Tension Meter KPM Interfacial Tension Meter KPM-OPPT-01 KPM Oil Pour Point Tester KPM PDTI Monitor KPM Online Partial Discharge Monitor with Temperature & Sht. Ckt Current for HV Cable terminations KPM PDM-01 KPM Partial Discharge Monitor KPM Duo PD KPM online Partial Discharge Tester with acoustic and TEV sensors KPM PD Pulse-8 KPM Online PD Tester for PD Monitoring of switchgears and Ring Main Units KPM PDA-01 KPM Partial Discharge Analyzer , electrical method KPM Penta PD KPM Hand Held partial discharge Tester with TEV , HFCT, AE , Contact Acoustic, UHF sensors KPM CORONA POINTER KPM PD Pointer for laboratory corona finding KPM PQA+ KPM Power Quality Analyzer and recorder KPM - PQ Analyzer Light KPM Power Quality Analyzer and recorder KPM LA 100 + , LA TESTER KPM LA Tester / Surge arrester Tester / MOA Tester / 3rd harmonic leakage current tester kpm la 103+ KPM LA Tester / Surge arrester Tester / MOA Tester / 3rd harmonic leakage current tester KPM MT 3000 D 3-Phase energy meter tester KPM SF6 DPM Light KPM SF6 Dew Point Meter KPM CTTC KPM CT Heat Run Test Device KPM CEST KPM Clamp Earth Spike Tester KPM CET 1200 KPM Clamp Earth Tester KPM ET30K KPM Earth Tester with Spikes KPM GERM KPM Online Grid Earth Resistance Monitor KPM CM-0524 KPM Cell Voltage Monitor for Li Ion Batteries KPM battery load bank KPM DC Load Bank , KPM Battery Discharge Kit , KPM Constant Current DC load banks

  • Tap Changer Testing | KPM Engineering Solutions Pvt. Ltd. |Tap Changer Testing

    Transformer on-load tap changer analyzer is a combination of Transition Timer & Winding Resistance Tester. In KPM Engineering Sol. Pvt. Ltd we are one point solution for all type of power system testing need |https://www.kpmtek.com/oltcanalyzer ANALIZATOR PRZEŁĄCZNIKA ZACZEPÓW POD OBCIĄŻENIEM (OLTC). Zobacz więcej Skontaktuj się z nami Analizator przełącznika zaczepów KPM Analizator przełącznika zaczepów pod obciążeniem transformatora to połączenie Timer przejścia & Tester rezystancji uzwojenia. KPM Transformer analizator podobciążeniowych przełączników zaczepów to wszechstronne urządzenie pomiarowe do pomiaru i analizy wskaźników wydajności elektrycznej transformatorów mocy i specjalnych przełączników zaczepów pod obciążeniem w systemy zasilania. Przyjmuje sterowanie mikrokomputerem, a dzięki zaprojektowaniu precyzyjnego obwodu pomiarowego może realizować dokładny pomiar czasu przejścia, kształtu fali przejścia, rezystancji przejścia i synchronizacji trójfazowej włączenia -obciążenie przełącznika zaczepów. Użytkownik może przetestować przełącznik zaczepów z i bez uzwojenia transformatora. Przyrząd posiada funkcje wyświetlania, analizy, przechowywania i drukowania zmierzonych danych. Możliwa jest diagnoza potencjalnej awarii przełącznika zaczepów pod obciążeniem w teście prewencyjnym urządzeń elektroenergetycznych i przeglądzie transformatora, co ma ogromne znaczenie dla poprawy niezawodności pracy systemu elektroenergetycznego. Parametry techniczne 1> prąd wyjściowy: 1,0 a, 0,5 a, 0,3 a 2> Zakres rezystancji: 1,0 A bieg 0,1 ~ 10 Ω, 0,5 A bieg 5 ~ 20 Ω, 0,3 A bieg 10 ~ 40 Ω 3> Dokładność pomiaru rezystancji: 0,1 Ω ~ 1 Ω ± 0,1 Ω, 1 Ω ~ 40 Ω ± 1% (bez 1 Ω) 4> Pomiar czasu przejścia: zakres 1 ~ 250 ms, dokładność: 1 ms ~ 100 ms ± 0,1 ms 100 ms ~ 250 ms ± 1% 5> Częstotliwość próbkowania: 10 ~ 20 KHz 6> synchronizacja trójfazowa: 0,01 ms 7> Temperatura pracy: 0 ~ 40 ° C 8> Wilgotność otoczenia: ≤90% RH, bez kondensacji 9> Wymiary (mm): 420 × 350 × 220, waga: 12 kg (wraz z akcesoriami)