top of page

Search Results

Search this site

Znaleziono 85 wyników za pomocą pustego wyszukiwania

  • KPM EU Operations | KPM India |KPM EU Operations

    Benefiting world with INDO-EU partnerships, We are working in 1) Electrical t & m equipment 2) OEM services for Made In India electrical equipment 3) Sales & Purchase of Used / New M/Cs ( EU Origin ) all across the world . for detail visit us on http://www.kpmtek.eu MADE IN INDIA - OEM SERVICES CT , PT , Metering Cubicle , Isolators etc. TECH TIEUPS - POWER SECTOR Electrical Testing & Monitoring Solutions NEW / USED MACHINES - EU Printing M/C, Paper Converting M/C. etc. Korzyści_cc781905-5cde-3194-BB3B-136BAD5CF58D_ WORD_CC781905-5CDE-3194-BB3B-136BAD5CF58D_ with Ind USŁUGI OEM DO TRANSFORMATORÓW INSTRUMENTÓW ( DO 33KV ) Świadczymy usługi OEM dla klientów z regionu UE for Transformatory przyrządów (odlew olejowy i żywiczny, do 33 KV), izolatory, szafki pomiarowe i akcesoria do linii przesyłowych. Wszystkie nasze produkty są wytwarzane w najnowocześniejszych zakładach w Indiach z zachowaniem jakości na najwyższym poziomie. Każdy sprzęt wysyłany przez zespół KPM jest testowany zgodnie z wymaganiami testów fabrycznych IEC . Transformator instrumentu i wyposażenie. Mfg. - WELLMAN INDIE +48 539438443 sprzedaż@kpmtek.eu CT PT OEM MASZYNY UŻYWANE Z REGIONU UE Czy jesteś firmą chętną do zakupu używanych, niezawodnych europejskich maszyn technologicznych z regionu UE? Nie bez powodu jesteśmy pierwszym wyborem klientów takich jak ty ! Jesteśmy indyjską firmą zajmującą się dostawą wysokiej jakości starych maszyn z regionu UE do subkontynentu indyjskiego oferty w szerokiej gamie Maszyny fleksograficzne i offsetowe Maszyny do przetwarzania papieru, przyrządy i osprzęt Maszyny specjalnego przeznaczenia. Nasi konsultanci techniczni na stałe stacjonują w regionie UE, którzy świadczą usługi kontroli jakości używanych maszyn od zera. Nasi eksperci monitorują proces demontażu aż do etapu załadunku . W Indiach mamy doświadczony zespół do sprawnego uruchamiania i rozwiązywania problemów z dostarczonymi maszynami. Każda dostarczona przez nas maszyna jest objęta roczną gwarancją w REGIONIE SUBKONTYNENTU INDYJSKIEGO Skontaktuj się z nami już dziś i omów maszyny, których szukasz! INDIE WSPARCIE PARTNER - WEBTECH , producent wysokiej jakości drukowanie , przetwarzanie papieru i SPM . +48 539438443 sprzedaż@kpmtek.eu formularz zapytania Rozwiązania dla sektora energetycznego Powiązania technologiczne i korporacyjne KPM ma ogromne doświadczenie w sprzedaży i stosowaniu elektrycznych urządzeń testujących i pomiarowych zarówno wysokiego, jak i niskiego napięcia. Każde urządzenie dostarczone przez KPM Engineering jest sprawdzone w warunkach polowych. Nasze urządzenia do testowania podstacji są testowane w hałaśliwych warunkach LIVE EHV - UHV Switchyards (do 765KV) Jesteśmy aktywnie otwarci na dyskusje i poszukujemy rozwiązań korporacyjnych i technicznych Firma badawczo-projektowa z pewnym rozwiązaniem dla sektora energetycznego, szukająca powiązań technicznych. Użytkownik / dystrybutor chętny do sprzedaży / zakupu istniejących rozwiązań firmy KPM Testowanie i monitorowanie rozwiązań w regionie UE . Inwestorzy i współpracownicy +48 539438443 sprzedaż@kpmtek.eu USED MACHINES POWER SECTOR TIEUPS

  • KPM Transformer Oil Testing | Oil Analysis & Diagnostics|Transformer Oil Testing

    Advanced transformer oil testing by KPM for precise oil analysis, insulation assessment, and efficient transformer maintenance. WYPOSAŻENIE LABORATORIUM TESTOWEGO OLEJU TESTER TEMPERATURY ZAPŁONU (KPM OT 01) Zobacz więcej Tester temperatury zapłonu oleju transformatorowego KPM OT 01 z zamkniętym kubkiem to automatyczny zamknięty tester temperatury zapłonu. Służy do pomiaru otwartej, zamkniętej temperatury zapłonu produktów ropopochodnych. Parametry techniczne-: 1. Pomiar temperatury Zakres pomiaru temperatury: -59,9°C ~ 299,9°C Zakres regulacji temperatury: Temperatura pokojowa ~ 300°C Powtarzalność: 0,025X (x = dwukrotna średnia wartość testu z rzędu) Rozdzielczość: 0,1°C Precyzja: 0,5% Czujnik temperatury: rezystor platynowy (PT100) Flash Fire Sensor: Pierścień wykrywania jonów 2. Temperatura otoczenia: 0 ~ 40°C 3. Wilgotność względna: ≤ 85% RH 4. Zasilanie: AC220V ± 20% ; 50 Hz ± 10% 5. Pobór mocy: około 400 W TESTER TEMPERATURY ZAPŁONU (KPM OT 01) Zobacz więcej Tester temperatury zapłonu oleju transformatorowego KPM OT 01 z zamkniętym kubkiem to automatyczny zamknięty tester temperatury zapłonu. Służy do pomiaru otwartej, zamkniętej temperatury zapłonu produktów ropopochodnych. Parametry techniczne-: 1. Pomiar temperatury Zakres pomiaru temperatury: -59,9°C ~ 299,9°C Zakres regulacji temperatury: Temperatura pokojowa ~ 300°C Powtarzalność: 0,025X (x = dwukrotna średnia wartość testu z rzędu) Rozdzielczość: 0,1°C Precyzja: 0,5% Czujnik temperatury: rezystor platynowy (PT100) Flash Fire Sensor: Pierścień wykrywania jonów 2. Temperatura otoczenia: 0 ~ 40°C 3. Wilgotność względna: ≤ 85% RH 4. Zasilanie: AC220V ± 20% ; 50 Hz ± 10% 5. Pobór mocy: około 400 W TESTER LEPKOŚCI (KPM OT O3) Zobacz więcej Lepkość kinematyczna jest miarą siły tarcia wewnętrznego, gdy ciecz przepływa pod działaniem grawitacji, a jej wartość jest stosunkiem lepkości dynamicznej do gęstości w tej samej temperaturze, co jest jedną z ważnych właściwości fizycznych i chemicznych cieczy. oznaczenie gatunku i jakości oleju. W praktyce odpowiedni dobór lepkości oleju smarowego może zapewnić normalną i niezawodną pracę urządzeń mechanicznych. KPM OT 03 to specjalny sprzęt testowy zaprojektowany i wyprodukowany w oparciu o normy krajowe / standardy międzynarodowe. KPM OT 03 nadaje się do oznaczania lepkości kinematycznej ciekłych produktów naftowych. Przyrząd posiada funkcję timera czasu ruchu próbki oraz funkcję automatycznego obliczania końcowych wyników lepkości kinematycznej. Właściwości przyrządu do pomiaru lepkości kinematycznej ◆ Stała wiskozymetru, wartość kontroli temperatury, temperatura dostrajania, liczba testów i inne parametry można ustawić za pomocą klawiatury, instrument ma funkcję pamięci, aby automatycznie zapisać zestaw danych po raz pierwszy ◆Zastosuj importowany czujnik i zupełnie nową cyfrową samodostrajalną technologię kontroli temperatury PID, która ma szeroki zakres regulacji temperatury i wysoką precyzję kontroli temperatury ◆Zegar kalendarza nie wyłącza się i automatycznie wyświetla aktualny czas po uruchomieniu ◆Alternatywna funkcja komunikacji sieciowej, zdalne sterowanie, tabulacja ◆ Przycisk bez znaczników, obsługa jest intuicyjna i prosta. ◆Liczba czasu eksperymentu wynosi od 1 do 6 razy/czasów, co jest regulowane i wygodne ◆Eksperymentalny zapis można zapisać do późniejszego wglądu. Lepkościomierz kinematyczny Parametry techniczne ◆ Otwór do kąpieli w płynie: 4 otwory ◆Zakres regulacji temperatury: temperatura pokojowa —120℃ ◆Dokładność regulacji temperatury: ≤ ± 0,01℃ ◆Moc grzewcza: 1000W ◆Czasy testu: od 1 do 6 razy/czasów, regulowane OLEJ TAN DELTA ( KPM OTD 01 ) Zobacz więcej KPM OTD01 is used for measuring dielectric dissipation_cc781905 -5cde-3194-bb3b-136bad5cf58d_factor and DC resistivity of insulating oil_cc781905 -5cde-3194-bb3b-136bad5cf58d_and other płyny izolujące._cc781905-5cde-3194-bb3b-136cf58bad5 KPM OTD01 w automatycznym czyszczącym testerze strat dielektrycznych i rezystywności oleju izolacyjnego 1.Oil cup is cleaned automatically and_cc781905-5cde-3194-bb3b- 136bad5cf58d_has electrode calibration function._cc781905-5cde-3194-bb3 2. Internal standard capacitor electrode type_cc781905-5cde-3194-bb3b- 136bad5cf58d_capacitor, with electrode spacing 2mm. 3.Large-screen LCD,backlight, display is clear._cc781905-5cde-3194-bb3b- 136zły5cf58d_ 4.More accurate. Testing AC power supply_cc781905-5cde-3194- bb3b-136bad5cf58d_adopts AC - DC -_cc781905-5cde-3194 -bb3b-136bad5cf58d_AC conversion method. 5.Equipped with overvoltage, overcurrent and limit_cc781905-5cde-3194- bb3b-136bad5cf58d_ zabezpieczenia. 6.Measured temperature and system clock. _cc781905-5cde-3194- bb3b-136bad5cf58d_ Technical Parameters Power Voltage : AC 220V ± 10% Moc częstotliwość: 50Hz/60Hz ± 1% Measurement Rangecapacitance: 5pF ~ 200pF względna permittivity : 1.000~30.000 dielectric dissipation factor : 0.00001~100 DC Rezystywność: 2.5 MΩm~20 TΩm Pomiar Dokładność pojemności: ±(1% odczytu + 0,5pF) względna przepuszczalność: ±1% odczyt dielectric dissipation factor : ±(1% reading +0.0001) DC rezystywność: ±10% reading Rozdzielczość Ratio pojemność: 0,01pF względna przepuszczalność : 0,001 dielectric dissipation factor : 0,00001 Temperatura Range: 0~125℃ Thermometric Błąd: ±0,5℃ AC testing voltage : 500 ~ 2200V adjustable,_cc781905-5cde- 3194-bb3b-136bad5cf58d_frequency 50 HZ DC testing voltage : 0 ~ 500V adjustable Power Dissipation: 100w Boundary wymiar: 500mm*360mm*420mm Waga: 22 kg TESTER KWASOWOŚCI ( KPM OT 05 ) Zobacz więcej Kwasowość oleju transformatorowego jest właściwością szkodliwą. Jeśli olej staje się kwaśny, zawartość wody w oleju staje się bardziej rozpuszczalna w oleju. Kwasowość oleju pogarsza właściwości izolacyjne papierowej izolacji uzwojeń. Kwasowość przyspiesza proces utleniania w oleju. Kwas obejmuje również rdzewienie żelaza w obecności wilgoci. The kwasowość oleju transformatorowego jest miarą kwaśnych składników zanieczyszczeń. Kwasowość oleju wyraża się w mg KOH potrzebnej do zneutralizowania kwasu obecnego w gramie oleju. Jest to również znane jako liczba neutralizacji. KPM OT 05 to automatyczny tester liczby kwasowej z następującymi funkcjami: Wielofunkcyjne narzędzie-może test kwasowa wartość oleju transformatorowego, oleju turbinowego i oleju opałowego. wyposażone w standardowe procedury kwasowania i kalibracji Całkowicie automatyczny Mikrodrukarka wyświetlacz LCD Wysoka dokładność Łatwa operacja Technical Parameter: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 olej Testing Range 0,001~1mg KOH/g Error ≤±0,001mg KOH/g Powtarzalność ≤0,002mg KOH/g Temperatura 10°C~45°C Humidity ≤85%RH Power Supply AC220V/50HZ Power 500W TESTER KWASOWOŚCI ( KPM OT 05 ) Zobacz więcej Kwasowość oleju transformatorowego jest właściwością szkodliwą. Jeśli olej staje się kwaśny, zawartość wody w oleju staje się bardziej rozpuszczalna w oleju. Kwasowość oleju pogarsza właściwości izolacyjne papierowej izolacji uzwojeń. Kwasowość przyspiesza proces utleniania w oleju. Kwas obejmuje również rdzewienie żelaza w obecności wilgoci. The kwasowość oleju transformatorowego jest miarą kwaśnych składników zanieczyszczeń. Kwasowość oleju wyraża się w mg KOH potrzebnej do zneutralizowania kwasu obecnego w gramie oleju. Jest to również znane jako liczba neutralizacji. KPM OT 05 to automatyczny tester liczby kwasowej z następującymi funkcjami: Wielofunkcyjne narzędzie-może test kwasowa wartość oleju transformatorowego, oleju turbinowego i oleju opałowego. wyposażone w standardowe procedury kwasowania i kalibracji Całkowicie automatyczny Mikrodrukarka wyświetlacz LCD Wysoka dokładność Łatwa operacja Technical Parameter: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 olej Testing Range 0,001~1mg KOH/g Error ≤±0,001mg KOH/g Powtarzalność ≤0,002mg KOH/g Temperatura 10°C~45°C Humidity ≤85%RH Power Supply AC220V/50HZ Power 500W TESTER KWASOWOŚCI ( KPM OT 05 ) Zobacz więcej Kwasowość oleju transformatorowego jest właściwością szkodliwą. Jeśli olej staje się kwaśny, zawartość wody w oleju staje się bardziej rozpuszczalna w oleju. Kwasowość oleju pogarsza właściwości izolacyjne papierowej izolacji uzwojeń. Kwasowość przyspiesza proces utleniania w oleju. Kwas obejmuje również rdzewienie żelaza w obecności wilgoci. The kwasowość oleju transformatorowego jest miarą kwaśnych składników zanieczyszczeń. Kwasowość oleju wyraża się w mg KOH potrzebnej do zneutralizowania kwasu obecnego w gramie oleju. Jest to również znane jako liczba neutralizacji. KPM OT 05 to automatyczny tester liczby kwasowej z następującymi funkcjami: Wielofunkcyjne narzędzie-może test kwasowa wartość oleju transformatorowego, oleju turbinowego i oleju opałowego. wyposażone w standardowe procedury kwasowania i kalibracji Całkowicie automatyczny Mikrodrukarka wyświetlacz LCD Wysoka dokładność Łatwa operacja Technical Parameter: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 olej Testing Range 0,001~1mg KOH/g Error ≤±0,001mg KOH/g Powtarzalność ≤0,002mg KOH/g Temperatura 10°C~45°C Humidity ≤85%RH Power Supply AC220V/50HZ Power 500W TESTER TEMPERATURY ZAPŁONU (KPM OT 01) Zobacz więcej Tester temperatury zapłonu oleju transformatorowego KPM OT 01 z zamkniętym kubkiem to automatyczny zamknięty tester temperatury zapłonu. Służy do pomiaru otwartej, zamkniętej temperatury zapłonu produktów ropopochodnych. Parametry techniczne-: 1. Pomiar temperatury Zakres pomiaru temperatury: -59,9°C ~ 299,9°C Zakres regulacji temperatury: Temperatura pokojowa ~ 300°C Powtarzalność: 0,025X (x = dwukrotna średnia wartość testu z rzędu) Rozdzielczość: 0,1°C Precyzja: 0,5% Czujnik temperatury: rezystor platynowy (PT100) Flash Fire Sensor: Pierścień wykrywania jonów 2. Temperatura otoczenia: 0 ~ 40°C 3. Wilgotność względna: ≤ 85% RH 4. Zasilanie: AC220V ± 20% ; 50 Hz ± 10% 5. Pobór mocy: około 400 W KARL FISCHER ( KPM OT 02) Zobacz więcej Titrator Karla Fischera KPM OT 02 is suitable in determining water content in_cc781905-5cde-3194- bb3b-136bad5cf58d_the liquid petroleum products by titration using_cc781905- 5cde-3194-bb3b-136bad5cf58d_Karl Fischer reagent. It adopts a microprocessor for control, so_cc781905-5cde- 3194-bb3b-136bad5cf58d_it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It_cc781905-5cde-3194- bb3b-136bad5cf58d_also has function of self-diagnostics, menu_cc781905-5cde- 3194-bb3b-136bad5cf58d_selection. It is a multifunctional, convenient, and automatic analysis_cc781905-5cde-3194-f5b1bstrument Wolumetryczny miernik wilgotności Karla Fischera Technical parameters: 1 Method Karl Fischer Coulometric Titrator_cc781905-5cde-3194-bb3b- 136bad5cf58d_Zasada 2 Typ Przenośny 3 Pomiar Range 0ug-100mg 4 Resolution 0.1ug 5 the Largest Electrolytic Speed 40_cc781905-5cde-3194-bb3b- 136bad5cf58d_ug/s 6 Power Supply Voltage AC220V ±20%(_cc781905-5cde -3194-bb3b-136bad5cf58d_customization) 7 Największy power 30w 8 Work Temperature 10~35℃ 9 Work Humidity ≤85% 10 Wymiary 320*240*150mm 11 Waga 5kg OLEJ TAN DELTA ( KPM OTD 01 ) Zobacz więcej KPM OTD01 is used for measuring dielectric dissipation_cc781905 -5cde-3194-bb3b-136bad5cf58d_factor and DC resistivity of insulating oil_cc781905 -5cde-3194-bb3b-136bad5cf58d_and other płyny izolujące._cc781905-5cde-3194-bb3b-136cf58bad5 KPM OTD01 w automatycznym czyszczącym testerze strat dielektrycznych i rezystywności oleju izolacyjnego 1.Oil cup is cleaned automatically and_cc781905-5cde-3194-bb3b- 136bad5cf58d_has electrode calibration function._cc781905-5cde-3194-bb3 2. Internal standard capacitor electrode type_cc781905-5cde-3194-bb3b- 136bad5cf58d_capacitor, with electrode spacing 2mm. 3.Large-screen LCD,backlight, display is clear._cc781905-5cde-3194-bb3b- 136zły5cf58d_ 4.More accurate. Testing AC power supply_cc781905-5cde-3194- bb3b-136bad5cf58d_adopts AC - DC -_cc781905-5cde-3194 -bb3b-136bad5cf58d_AC conversion method. 5.Equipped with overvoltage, overcurrent and limit_cc781905-5cde-3194- bb3b-136bad5cf58d_ zabezpieczenia. 6.Measured temperature and system clock. _cc781905-5cde-3194- bb3b-136bad5cf58d_ Technical Parameters Power Voltage : AC 220V ± 10% Moc częstotliwość: 50Hz/60Hz ± 1% Measurement Rangecapacitance: 5pF ~ 200pF względna permittivity : 1.000~30.000 dielectric dissipation factor : 0.00001~100 DC Rezystywność: 2.5 MΩm~20 TΩm Pomiar Dokładność pojemności: ±(1% odczytu + 0,5pF) względna przepuszczalność: ±1% odczyt dielectric dissipation factor : ±(1% reading +0.0001) DC rezystywność: ±10% reading Rozdzielczość Ratio pojemność: 0,01pF względna przepuszczalność : 0,001 dielectric dissipation factor : 0,00001 Temperatura Range: 0~125℃ Thermometric Błąd: ±0,5℃ AC testing voltage : 500 ~ 2200V adjustable,_cc781905-5cde- 3194-bb3b-136bad5cf58d_frequency 50 HZ DC testing voltage : 0 ~ 500V adjustable Power Dissipation: 100w Boundary wymiar: 500mm*360mm*420mm Waga: 22 kg TESTER KWASOWOŚCI ( KPM OT 05 ) Zobacz więcej Kwasowość oleju transformatorowego jest właściwością szkodliwą. Jeśli olej staje się kwaśny, zawartość wody w oleju staje się bardziej rozpuszczalna w oleju. Kwasowość oleju pogarsza właściwości izolacyjne papierowej izolacji uzwojeń. Kwasowość przyspiesza proces utleniania w oleju. Kwas obejmuje również rdzewienie żelaza w obecności wilgoci. The kwasowość oleju transformatorowego jest miarą kwaśnych składników zanieczyszczeń. Kwasowość oleju wyraża się w mg KOH potrzebnej do zneutralizowania kwasu obecnego w gramie oleju. Jest to również znane jako liczba neutralizacji. KPM OT 05 to automatyczny tester liczby kwasowej z następującymi funkcjami: Wielofunkcyjne narzędzie-może test kwasowa wartość oleju transformatorowego, oleju turbinowego i oleju opałowego. wyposażone w standardowe procedury kwasowania i kalibracji Całkowicie automatyczny Mikrodrukarka wyświetlacz LCD Wysoka dokładność Łatwa operacja Technical Parameter: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 olej Testing Range 0,001~1mg KOH/g Error ≤±0,001mg KOH/g Powtarzalność ≤0,002mg KOH/g Temperatura 10°C~45°C Humidity ≤85%RH Power Supply AC220V/50HZ Power 500W TESTER KWASOWOŚCI ( KPM OT 05 ) Zobacz więcej Kwasowość oleju transformatorowego jest właściwością szkodliwą. Jeśli olej staje się kwaśny, zawartość wody w oleju staje się bardziej rozpuszczalna w oleju. Kwasowość oleju pogarsza właściwości izolacyjne papierowej izolacji uzwojeń. Kwasowość przyspiesza proces utleniania w oleju. Kwas obejmuje również rdzewienie żelaza w obecności wilgoci. The kwasowość oleju transformatorowego jest miarą kwaśnych składników zanieczyszczeń. Kwasowość oleju wyraża się w mg KOH potrzebnej do zneutralizowania kwasu obecnego w gramie oleju. Jest to również znane jako liczba neutralizacji. KPM OT 05 to automatyczny tester liczby kwasowej z następującymi funkcjami: Wielofunkcyjne narzędzie-może test kwasowa wartość oleju transformatorowego, oleju turbinowego i oleju opałowego. wyposażone w standardowe procedury kwasowania i kalibracji Całkowicie automatyczny Mikrodrukarka wyświetlacz LCD Wysoka dokładność Łatwa operacja Technical Parameter: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 olej Testing Range 0,001~1mg KOH/g Error ≤±0,001mg KOH/g Powtarzalność ≤0,002mg KOH/g Temperatura 10°C~45°C Humidity ≤85%RH Power Supply AC220V/50HZ Power 500W TESTER KWASOWOŚCI ( KPM OT 05 ) Zobacz więcej Kwasowość oleju transformatorowego jest właściwością szkodliwą. Jeśli olej staje się kwaśny, zawartość wody w oleju staje się bardziej rozpuszczalna w oleju. Kwasowość oleju pogarsza właściwości izolacyjne papierowej izolacji uzwojeń. Kwasowość przyspiesza proces utleniania w oleju. Kwas obejmuje również rdzewienie żelaza w obecności wilgoci. The kwasowość oleju transformatorowego jest miarą kwaśnych składników zanieczyszczeń. Kwasowość oleju wyraża się w mg KOH potrzebnej do zneutralizowania kwasu obecnego w gramie oleju. Jest to również znane jako liczba neutralizacji. KPM OT 05 to automatyczny tester liczby kwasowej z następującymi funkcjami: Wielofunkcyjne narzędzie-może test kwasowa wartość oleju transformatorowego, oleju turbinowego i oleju opałowego. wyposażone w standardowe procedury kwasowania i kalibracji Całkowicie automatyczny Mikrodrukarka wyświetlacz LCD Wysoka dokładność Łatwa operacja Technical Parameter: Item Transformer oil acid value tester _cc781905-5cde-3194 -bb3b-136bad5cf58d_ Acidity_cc781905-5cde-3194 olej Testing Range 0,001~1mg KOH/g Error ≤±0,001mg KOH/g Powtarzalność ≤0,002mg KOH/g Temperatura 10°C~45°C Humidity ≤85%RH Power Supply AC220V/50HZ Power 500W Zestaw testowy BDV OLEJU (OBD 100A+) Zobacz więcej Jak sama nazwa wskazuje, Oil BDV Test Set (KPM-OBD100A+) służy do pomiaru wytrzymałości na przebicie oleju izolacyjnego. Zdolne do generowania 80/100 kV z wbudowaną drukarką. Zmotoryzowane i programowane mieszadło Lekki 0.5KV/sec to 5KV/sec variable voltage rise as per ASTM Standards ( available in "A+"_cc781905-5cde-3194-bb3b- modele 136bad5cf58d_) Zestaw testowy BDV OLEJU (OBD 100+) Zobacz więcej Jak sama nazwa wskazuje, Oil BDV Test Set (KPM-OBD 100+) służy do pomiaru wytrzymałości na przebicie oleju izolacyjnego. Zdolne do generowania 80/100 kV z wbudowaną drukarką. Zmotoryzowane i programowane mieszadło Lekki Wzrost napięcia o 2 KV/s z automatycznymi planami testów zgodnie z IEC i IS Często zadawane pytania ( FAQ ) FAQ about Oil testing : 01 How to Perform a Reliable 10kV Insulation Test? A 10kV insulation resistance test is used to evaluate the dielectric strength of high-voltage equipment like transformers, motors, and cables. To perform it reliably, first de-energize and isolate the equipment, ensuring it's properly grounded. Clean terminals to remove surface contamination. Connect the insulation tester leads: One to the conductor and the other to ground. Select the 10kV test voltage on the insulation resistance tester. Begin the test and monitor resistance for 1 to 10 minutes—longer durations help identify moisture or insulation defects. Readings should be in the GΩ (giga ohm) range for healthy insulation. Apply DAR (Dielectric Absorption Ratio) or PI (Polarization Index) analysis to assess insulation aging. Ensure environmental conditions are dry and free of electrical noise for accuracy. KPM provides high-voltage insulation testers with digital displays, timer functions, and built-in safety features, ensuring accurate, safe, and standards-compliant insulation testing across utility and industrial applications. 02 Differences Between 5kV, 10kV, and 15kV Insulation Testers? The main difference between 5kV, 10kV, and 15kV insulation testers lies in their test voltage output, which determines the type of equipment they are suited for and the depth of insulation assessment they provide. 5kV testers are typically used for low to medium voltage equipment like motors, cables, and switchgear up to 25kV. 10kV testers are suitable for higher-voltage systems such as power transformers, HV motors, and cables rated up to 69kV, providing a deeper insulation profile. 15kV testers are used for critical high-voltage assets above 69kV, enabling detection of insulation weaknesses that lower voltages may miss. Higher voltage testers stress insulation more, revealing latent defects and moisture absorption. However, using too high a voltage on low-rated equipment can cause damage. KPM offers 5kV, 10kV, and 15kV insulation testers with digital readings, polarization index (PI), and DAR calculations, ideal for field diagnostics and predictive maintenance. 03 What is Karl Fischer Titration ? Explain Moisture Testing in Oil. Karl Fischer (KF) titration is a precise chemical method used to measure moisture content (water) in substances, including insulating oils, with accuracy down to parts per million (ppm). It's the preferred method for transformer oil and lubricants because even trace moisture can degrade dielectric strength, cause corrosion, or affect equipment performance. How It Works: KF titration is based on a chemical reaction where iodine reacts with water in the presence of sulfur dioxide and alcohol, using a base (often imidazole or pyridine) as a catalyst: This reaction occurs until all water is consumed. The amount of iodine used is directly proportional to the moisture present. Types of KF Titration: Volumetric KF: For water content above 1%. Common in oil testing. Coulometric KF: For ultra-low moisture (<1%), generating iodine electrochemically. Advantages: Highly accurate (1–10 ppm range). Specific to water (no interference from other volatiles). Widely accepted in ASTM D1533 for transformer oil testing. KPM supplies Karl Fischer titrators for both volumetric and coulometric methods, used in power utilities and oil testing labs to ensure insulation oils remain within safe moisture limits. 04 How to Identify Oil Contamination Using BDV Testers? Breakdown Voltage (BDV) testing is a key method to identify contamination in insulating oils used in transformers, circuit breakers, and other high-voltage equipment. A BDV tester applies a gradually increasing AC voltage to a sample of insulating oil placed between two standard electrodes. Clean, dry oil has high dielectric strength and resists electrical breakdown. However, the presence of moisture, dissolved gases, carbon particles, or sludge lowers the breakdown voltage significantly. Typically, good transformer oil should withstand 30 kV or more in a 2.5 mm electrode gap. A low BDV reading (e.g., below 20 kV) suggests contamination. Multiple test cycles (usually 5–6) help eliminate anomalies and confirm consistency. KPM provides automated and manual BDV testers with features like automatic voltage ramping, stirrers for even testing, digital displays, and built-in standards (IEC 60156, ASTM D1816), ensuring accurate detection of oil contamination and timely maintenance planning. 05 What is Viscosity and Pour Point in Transformer Oils? Viscosity is the measure of a fluid's resistance to flow. In transformer oils, optimal viscosity is crucial for: Heat transfer: Low viscosity allows better circulation and cooling. Lubrication: Protects internal parts from wear. Pump efficiency: Thinner oil reduces mechanical stress on pumps. High viscosity at low temperatures can hinder oil movement, reducing cooling and increasing risk of overheating. Transformer oils typically have a viscosity range of 8–12 cSt at 40°C, as per IEC and ASTM standards. Pour Point: Pour point is the lowest temperature at which oil still flows. It indicates how oil behaves in cold environments. A low pour point ensures the oil remains pumpable and circulates properly during cold starts or winter operation. A good transformer oil has a pour point below -30°C, as per ASTM D97 or ISO 3016. KPM provides viscosity and pour point testing kits and services compliant with ASTM D445 and D97, ensuring transformer oil meets safety and performance standards. 06 What is Flash Point Testing? What are its Safety Standards and Applications? Flash point testing determines the lowest temperature at which a liquid emits enough vapor to ignite in the presence of an ignition source. It is a critical parameter for assessing the fire and explosion risk of flammable and combustible liquids such as fuels, lubricants, and transformer oils. This test ensures the safe handling, storage, and transportation of these substances. Globally recognized standards such as ASTM D93 (Pensky-Martens Closed Cup), ISO 2719, and ASTM D56 (Tag Closed Tester) provide standardized methods to ensure consistency and safety. Applications span industries like petrochemicals, energy, pharmaceuticals, and aviation, where accurate flash point data is essential for risk assessments, regulatory compliance, and material classification. KPM ensures strict adherence to international safety standards by offering flash point testers that comply with ASTM D93, ISO 2719, and related norms. KPM’s equipment features precision temperature control, sealed test chambers, and automation to eliminate user error. These instruments are calibrated and validated regularly to maintain measurement integrity. Additionally, KPM provides comprehensive support, including training and servicing, to ensure customers conduct testing safely and accurately. By aligning with global testing protocols, KPM plays a key role in advancing operational safety and regulatory compliance across 07 What is Oil Tan Delta? Also understanding Dielectric Loss. Tan Delta, also known as the dissipation factor, is a key parameter used to evaluate the dielectric loss in insulating oils. It represents the ratio of the resistive current to the capacitive current within the oil when subjected to an alternating electrical field. It measures the inefficiency or energy loss in the insulation system when subjected to an alternating electric field. A low Tan Delta value indicates good insulation quality with minimal dielectric loss, while a high value suggests aging, moisture contamination, or deterioration of the insulating oil. Tan delta testing is a crucial diagnostic tool for assessing the health of insulating oil. By understanding the relationship between tan delta, dielectric loss, and the condition of the oil, maintenance professionals can take steps to ensure the reliable and safe operation of electrical equipment. KPM offers advanced Tan Delta testing instruments that comply with IEC and ASTM standards. These kits provide accurate, real-time results with user-friendly operation and robust design. KPM also offers expert support, calibration, and on-site testing services to help utilities maintain insulation health effectively. 08 What are the Best Practices in Oil Sampling and Analysis? Accurate oil sampling and analysis are vital for assessing the condition of insulating oils used in transformers and other high-voltage equipment. Key best practices include taking samples from the correct location (ideally turbulent flow areas, upstream of filters, and not from drain plugs), at the right time (when the machine is running and under normal load), and with proper techniques (using clean equipment, avoiding contamination, and labeling samples accurately). Best practices include taking samples from live equipment using clean, dry, and airtight glass or metal containers to avoid contamination. Sampling should be done from designated sampling valves, ideally after allowing sufficient oil flow to flush impurities. Samples must be labeled clearly with details like equipment ID, location, date, and temperature. Proper analysis involves tests for moisture content, dielectric strength, acidity, interfacial tension, Tan Delta, and dissolved gas analysis (DGA), offering insights into oil aging, contamination, and equipment health. KPM provides a full range of oil testing instruments, including BDV testers, moisture analyzers (Karl Fischer), and Tan Delta kits, all adhering to IEC/ASTM standards. KPM also offers oil sampling kits, training, and onsite testing services, ensuring reliable diagnostics and extending asset life. 09 How to Interpret Insulation Resistance Test Results? Insulation resistance (IR) testing assesses the quality of insulation in electrical equipment by measuring its resistance to current flow. IR testing helps detect insulation weaknesses before they lead to equipment failure, short circuits, or electrical shocks. The test measures the resistance between conductors (e.g., wires) or between a conductor and ground, indicating how well the insulation is preventing current leakage. Interpreting these results involves understanding the expected values, identifying trends, and recognizing factors that can affect the readings. A high insulation resistance (in the megaohms or higher) generally indicates good insulation, while low readings suggest potential problems like moisture, contamination, or damage.. It is typically conducted using a megohmmeter at voltages like 500V, 1kV, or 5kV. Higher resistance values (in megaohms or gigaohms) indicate good insulation, while lower values suggest moisture ingress, dirt, or insulation deterioration. Acceptable IR values vary by equipment type, but a general rule is 1 MΩ per kV of operating voltage, with time-based readings (1 min, 10 min) used to calculate the polarization index (PI). A PI > 2 indicates good insulation; < 1.5 may signal problems. KPM offers reliable insulation resistance testers with digital displays, automatic PI/ DAR calculation, and high-voltage test capabilities (up to 20kV). Compliant with IEC and IEEE standards, KPM’s instruments ensure precise diagnosis. KPM also provides training and expert support to help customers accurately interpret IR results for preventive maintenance and asset safety. 10 What is Electrical Oil Testing According to ASTM/IEC Standards? Electrical insulating oils play a critical role in cooling and insulating transformers, circuit breakers, and other high-voltage equipment. Electrical oil testing, particularly for transformer oil, is crucial for assessing its performance and detecting potential issues. Various ASTM and IEC standards govern these tests, ensuring consistent and reliable results. These standards cover a range of properties like dielectric breakdown voltage, acidity, moisture content, and more. Key ASTM and IEC Standards for Electrical Oil Testing: 1. Dielectric Breakdown Voltage: IEC 60156: Specifies the method for determining the dielectric breakdown voltage of insulating liquids at power frequency. This test is vital for assessing the oil's ability to withstand electrical stress. ASTM D877: Another standard for determining dielectric breakdown voltage, using disk electrodes. ASTM D1816: Uses VDE electrodes for the same purpose. 2. Moisture Content: IEC 60814: Specifies the method for determining the water content in insulating liquids. 3. Acidity (Neutralization Value): IEC 62021-1: Provides the standard for determining the acidity of insulating liquids. 4. Dissolved Gas Analysis (DGA): While not explicitly mentioned in the provided context, DGA is a crucial test for identifying potential problems like overheating or arcing within a transformer. 5. Other Important Tests: IEC 60422: Covers various aspects of insulating oil, including appearance, color rating, and sludge content. ASTM D1500: Specifies the method for determining the color of petroleum products. Interfacial Tension (ASTM D971): Indicates the presence of soluble contaminants. Resistivity (IEC 60247): Measures the oil's ability to resist electrical current flow. Dissipation Factor (IEC 60247): Indicates the energy loss in the oil due to dielectric losses. Flash Point (ASTM D92, ASTM D93): Determines the temperature at which the oil will ignite. Pour Point (ASTM D97): Indicates the lowest temperature at which the oil will flow. Viscosity (ASTM D445): Measures the oil's resistance to flow. KPM provides a comprehensive range of oil testing instruments aligned with ASTM and IEC standards. These include BDV testers, Tan Delta analyzers, moisture testers. KPM also offers calibration, on-line testing, and training services, ensuring users maintain transformer health and meet regulatory requirements effectively. 11 How to measure oil density and what are its implications? Oil density is the mass per unit volume (typically expressed in kg/m³ or g/cm³) and is a key parameter in evaluating the quality and type of insulating oils used in transformers and electrical equipment. Measuring oil density helps in determining its composition, potential uses, and potential for refining into various products like gasoline, diesel, or asphalt. Changes in oil density can indicate contamination, degradation, or improper formulation, affecting cooling efficiency, dielectric strength, and compatibility with equipment materials. Accurate density measurement is essential during oil processing, quality checks, and routine maintenance. It is often performed at a standard reference temperature (usually 15°C or 20°C) using digital density meters or hydrometers, in line with ASTM D4052 or ISO 12185 standards. KPM offers precise digital density meters and oil analysis kits compliant with international standards. These tools are designed for ease of use, fast operation, and high accuracy. With additional support like calibration services and technical guidance, KPM ensures reliable oil density measurement, aiding customers in maintaining transformer performance and operational safety. 12 What are the Early Warning Signs from Your Oil Particle Counter? An oil particle counter detects and quantifies solid contaminants in insulating oil, providing early warning signs of equipment wear, insulation breakdown, or external contamination. Key indicators include: Rising Particle Counts: A sudden increase in particles, especially >4µm or >6µm, can signal insulation aging, arcing, or mechanical wear. Shift in Particle Size Distribution: A higher concentration of larger particles may indicate internal component failure. Exceeding ISO 4406 Cleanliness Codes: Values outside acceptable limits suggest a decline in oil cleanliness, potentially leading to reduced dielectric strength and accelerated aging. Regular monitoring allows for trend analysis, helping prevent failures before they occur. KPM provides portable and lab-grade oil particle counters aligned with ISO 4406 and NAS 1638 standards. These instruments offer accurate, real-time data for critical decision-making. Combined with expert support and service, KPM enables power utilities and industries to ensure oil cleanliness and extend equipment lifespan. 13 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? Using both TEV and ultrasonic methods together enhances diagnostic accuracy: TEV gives insight into internal discharge severity and location. Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. This dual-method approach is vital for: Preventive maintenance, Avoiding insulation failures, Improving switchgear reliability, and Extending equipment life without needing shutdowns.

  • Partial Discharge Testing Equipment by KPM | PD Diagnostics|Partial Discharge

    Advanced partial discharge testing equipment by KPM for precise detection, insulation analysis, and condition monitoring of electrical assets. MONITOROWANIE PD I UZIEMIENIA ONLINE KPM PENTA PD (HAND HELD) View more Partial Discharge Detector Penta-PD is an ideal partner for condition-based maintenance programs. Partial Discharge Detector Penta-PD incorporates all 5 types of online PD sensor technology. Information from multiple sensors gives Partial Discharge Detector Penta-PD the versatility to detect various type PD in variety of substation apparatus. KPM PDM-01,Partial Discharge Monitor View more The KPM PDM-01 partial discharge detector stands out as a versatile digital tool within KPM's product range. Featuring a 10.1-inch touch screen, it replaces the traditional oscilloscope tube and physical knob operation, enhancing user convenience. The instrument employs a full touch screen interface, contributing to extended product longevity and incorporates useful features such as automatic correction, high voltage divider ratio settings, and serial communication for uploading test data. KPM PDTI Cable Termination Monitor View more The KPM PDTI system is deployed on primary switching equipment such as ring network switch cabinets, cable termination boxes, and transformer output cables etc. within the power distribution network. Its primary function is to conduct online monitoring of partial discharge, indicating potential short circuits and ground faults in corresponding cable sections, along with real-time temperature monitoring. KPM Corona Pointer View more KPM Corona Pointer is an ideal equipment for condition-based maintenance programs. Online partial discharge testing is a method of inspecting the insulation of electric power systems while equipment remains energized and in service. Corona Pointer is based on online Ultrasonic PD sensor technology. KPM Duo PD - Handheld PD monitoring system View more KPM Duo PD is a handheld partial discharge tester which uses the ultrasonic signal generated by partial discharge to determine the existence and location of partial discharge and combines the real-time displayed images and data to quickly diagnose partial discharge conditions. KPM PDA-01, Partial Discharge Monitor View more The KPM PDA-01 features a split, modular design, with the local discharge signal conditioning module, digital acquisition module, and test voltage acquisition module integrated into the instrument. The powerful local discharge test and analysis system software is installed on the host computer, which connects to the instrument via USB and RS232 serial ports. KPM PD Pulse-8, Online Partial Discharge Monitor View more KPM PD Pulse-8 partial discharge online monitoring device includes a modularly designed partial discharge sensor and a partial discharge data processing terminal. The partial discharge sensor can effectively monitor ultrasonic and transient earth voltage signals. Its sensors are a two-in-one integrated assembly that can be installed on the HV equipment. Często zadawane pytania ( FAQ ) FAQ about Partial discharge : 01 What are the Top 5 PD Testing Techniques – A Quick Comparison? 1) Ultrasonic PD Detection - Detects sound waves from PD events - Portable, good for on-site inspections - Limited sensitivity in noisy environments 2) High-Frequency Current Transformer (HFCT) - Measures high-frequency currents on cables - Effective for early PD detection - Requires access to grounding points 3) Transient Earth Voltage (TEV) - Detects electromagnetic signals from PD inside metal enclosures - Non-intrusive and widely used in switchgear - Limited for external PD sources 4) Oscilloscopic PD Measurement - Directly captures PD pulses using specialized sensors - Very detailed and accurate - Requires expert analysis and controlled environment 5) Acoustic Emission (AE) Sensors - Captures elastic waves from PD activity - Useful for localizing PD sources - Can be affected by external noise - KPM offers advanced PD measurement systems combining multiple techniques for comprehensive, reliable diagnostics. 02 What do you understanding AE, HFCT, TEV, and UHF – Which PD Kit Do You Need? Choosing the right Partial Discharge (PD) testing kit depends on your equipment type, accessibility, and testing goals. Here’s a quick comparison: 1. AE – Acoustic Emission How it works: Detects sound waves from PD using piezoelectric sensors. Best for: Transformers, bushings, and GIS (localizing PD points). Pros: Non-invasive, good for pinpointing PD. Limitations: Sensitive to external noise. 2. HFCT – High-Frequency Current Transformer How it works: Clamped around the grounding conductor to detect PD pulses. Best for: Cables, terminations, rotating machines. Pros: Early detection, non-intrusive. Limitations: Needs grounding access; less effective in noisy ground systems. 3. TEV – Transient Earth Voltage How it works: Senses electromagnetic emissions on metal-clad switchgear. Best for: MV switchgear (metal-enclosed). Pros: Easy to use, fast screening. Limitations: Doesn’t work well on non-metallic enclosures. 4. UHF – Ultra High Frequency How it works: Captures high-frequency EM waves from PD (300 MHz+). Best for: GIS, gas-insulated transformers, sealed systems. Pros: Very sensitive and noise-immune. Limitations: Needs access to UHF sensors or couplers. Which Kit Do You Need? For switchgear: TEV + AE For cables and rotating machines: HFCT For GIS or sealed systems: UHF + AE For transformers and bushings: AE + HFCT KPM offers hybrid PD testing kits combining AE, TEV, HFCT, and UHF sensors for complete diagnostics across all asset types—helping you localize, classify, and trend PD activity efficiently. 03 What is principle of detecting PD in Switchgear Using TEV Method ? The Transient Earth Voltage (TEV) method detects partial discharge activity in metal-clad switchgear by capturing fast, high-frequency voltage transients that appear on the internal metal surfaces of the switchgear enclosure. How It Works: When partial discharge occurs inside the insulation of live parts (e.g., busbars, bushings), it emits electromagnetic pulses. These pulses induce high-frequency voltage transients on the inner surface of the switchgear's metal enclosure. These transients propagate through the metal, eventually reaching the outer surface. A TEV sensor, placed magnetically or capacitively on the metal surface, detects these transient voltages—typically in the range of MHz frequencies. Why It Works Well for Switchgear: Switchgear panels are metal-enclosed, which acts as a waveguide for the transient signals. TEV signals indicate internal insulation defects like surface tracking, void discharges, or corona inside the equipment. TEV detection is non-invasive, requires no shutdown, and is widely used for condition-based maintenance. What TEV Tells You: Presence of internal PD Severity of the discharge (by amplitude and repetition rate) Useful for early detection before insulation failure KPM’s PD testing kits integrate TEV sensors with digital displays and trending software, making it easy to perform on-site diagnostics of medium-voltage switchgear for early PD detection and risk assessment. 04 What are the Diagnosing Cable Defects With HFCT-Based PD Testing ? High-Frequency Current Transformer (HFCT) sensors are widely used for detecting and diagnosing partial discharge (PD) activity in power cables. They are clamped around the earth (ground) conductor to sense high-frequency current pulses generated by insulation defects. How HFCT PD Testing Works: PD Activity Inside Cable Insulation: Voids, cracks, or deteriorated insulation cause small electrical discharges. Pulse Propagation: These discharges generate high-frequency current pulses (MHz range) that flow along the grounding system. HFCT Sensor Detection: The HFCT sensor detects these pulses non-invasively by clamping it around the cable’s earth conductor without disconnecting the system. Signal Analysis: The captured pulses are analyzed for: Pulse shape and repetition rate Time-of-flight (for PD location) Amplitude and phase-resolved patterns (PRPD) What It Diagnoses: Defects in cable joints, terminations, insulation Water trees or aging in XLPE cables Internal corona or tracking activity Advantages of HFCT PD Testing: Online or offline testing possible Non-intrusive and safe Early detection prevents costly cable failures Can be used with multiple sensors for PD location (triangulation) KPM’s HFCT-based PD testing solutions are designed for rapid setup, high sensitivity, and advanced diagnostics—enabling utilities and industries to monitor cable health with confidence. 05 What is UHF PD Testing in GIS – High Sensitivity Explained? Ultra High Frequency (UHF) PD testing in Gas-Insulated Switchgear (GIS) is a highly sensitive method that detects partial discharge by capturing electromagnetic signals in the 300 MHz to 1.5 GHz range. GIS enclosures, being metallic and sealed, confine PD signals and create a low-noise environment—making UHF detection extremely effective. UHF sensors, typically built into or attached to the GIS via couplers or antennae, pick up these fast transients without interfering with system operation. This method offers excellent immunity to external noise and allows early detection of insulation defects such as voids, surface discharges, or corona, enabling preventive maintenance and reducing outage risk. KPM’s UHF PD solutions are optimized for GIS testing, offering precise, real-time diagnostics with minimal intrusion. 06 How PD Can Cause Catastrophic Failures If Left Undetected ? Partial Discharge (PD) is a small electrical spark that occurs within insulation systems due to defects like voids, cracks, or contamination. While each discharge releases only a small amount of energy, repeated activity degrades insulation over time, leading to progressive damage. If left undetected, PD can cause tracking, erosion, thermal breakdown, and eventually a complete insulation failure. This can result in catastrophic equipment breakdowns, fires, arc flash events, or prolonged outages. Early PD detection helps identify developing faults before they escalate, allowing timely intervention. KPM’s PD monitoring solutions provide accurate diagnostics to prevent such costly and dangerous failures. 07 How Often Should You Perform Partial Discharge Tests? The frequency of Partial Discharge (PD) testing depends on equipment type, criticality, age, and operating environment: New Installations: Test during commissioning to detect manufacturing or installation defects. Routine Maintenance: For critical assets (e.g., GIS, transformers, cables): annually or semi-annually For less critical systems: every 2–3 years Condition-Based Monitoring: For aging or high-risk equipment, use continuous or periodic online PD monitoring. After Major Events: Test after faults, repairs, or overloading. KPM offers both portable and continuous PD monitoring solutions tailored to asset condition and reliability goals. 08 What is Acoustic Emission for PD Detection – Emerging Trends? Acoustic Emission (AE) is an emerging technique in Partial Discharge (PD) detection, leveraging sound waves generated by PD activity within high-voltage equipment. AE sensors capture ultrasonic emissions, allowing non-intrusive, real-time monitoring of insulation health. Recent trends include the integration of AI algorithms for noise discrimination, wireless AE sensor networks for wide-area monitoring, and hybrid systems combining AE with UHF or HFCT methods for higher accuracy. KPM’s PD monitoring device incorporates these advancements by using sensitive AE sensors to detect PD in transformers, switchgear, and cable terminations. The system filters external noise and correlates AE signals with discharge activity, ensuring precise fault localization. Its compact design, cloud integration, and user-friendly interface make it suitable for continuous condition monitoring. This enables utilities to predict insulation failure early, plan timely maintenance, and improve grid reliability while aligning with modern digital substation standards. 09 What to Watch Out For while working on PD Testing in Motors and Generators ? Partial Discharge (PD) testing in motors and generators is critical for identifying early insulation deterioration, especially in high-voltage rotating machines. Key factors to watch out for include surface discharge near end windings, slot discharges, and internal PD caused by insulation voids. External noise interference, poor sensor placement, and incorrect test settings can lead to false readings or missed defects. It’s essential to differentiate between actual PD signals and electrical noise, especially in operational (online) testing. KPM’s PD tester addresses these challenges with high-frequency current transformer (HFCT) sensors, advanced noise separation algorithms. The device enables clear PD signal capture even in electrically noisy environments. It provides real-time analysis, waveform capture, and trend data, helping maintenance teams make informed decisions. KPM’s compact, rugged design and intuitive interface make it ideal for field diagnostics in motors and generators across power plants and industrial sites. 10 How to Interpret PD Signals? Interpreting Partial Discharge (PD) signals is crucial for diagnosing insulation issues accurately. Real-world case studies reveal that many failures arise not from PD presence, but from misinterpretation. In one case, a generator end-winding PD signal was mistaken for noise due to poor sensor grounding. Another involved a cable joint where increasing PD magnitude over time indicated a void-related breakdown—early intervention prevented a costly outage. Key learnings include the importance of phase-resolved PD (PRPD) pattern analysis, baseline signal comparison, and monitoring PD trends over time. Environmental noise, load conditions, and sensor placement significantly impact data quality. KPM’s PD tester simplifies interpretation with built-in PRPD pattern recognition, automated classification, and trend analytics. Its intelligent algorithms filter out noise and identify critical PD types—internal, surface, or corona—with high accuracy. By offering both real-time insights and historical tracking, KPM's tester empowers engineers to make confident maintenance decisions and extend asset life. FAQ about Monitoring testing : 01 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? Using both TEV and ultrasonic methods together enhances diagnostic accuracy: TEV gives insight into internal discharge severity and location. Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. This dual-method approach is vital for: Preventive maintenance, Avoiding insulation failures, Improving switchgear reliability, and Extending equipment life without needing shutdowns.

  • SF6 Gas Testing Equipment by KPM | Gas Analysis & Detection|SF6 Gas Test Equipment

    KPM SF6 gas test equipment ensures accurate measurement, reliable diagnostics, and efficient monitoring for electrical and industrial applications. GAZ SF6 (GIS) PRZYRZĄDY TESTOWE Analizator gazu SF6 Specyfikacja techniczna -: 1. Czystość SF6: 0 ~ 100% SF6 (stosunek wagowy); 2. Produkty rozkładu SF6: 1.SO2: 0 ~ 200 ppm; 2.H2S: 0 ~ 200ppm; 3.HF: 0 ~ 10 ppm; 4. CO : 0 ~ 1000ppm; 3. Dokładność pomiaru a) Czystość SF6: ± 0,1%, niezależnie od przepływu; b) Produkty rozkładu SF6: 0,1 ppm; 4) Czas reakcji a) czystość SF6: 30s; b) Produkty rozkładu SF6: 10 ~ 15s. Skontaktuj się z nami Miernik punktu rosy SF6 ( KPM DPM-01 ) Szeroko stosowany w warsztatach, biurach, zakładach, stacjach komputerowych, laboratoriach i magazynach. Ręczny miernik punktu rosy KPM-DPM-82H służy do sprawdzania punktowego i kalibracji w terenie. Zapewnia dokładny i szybki pomiar w przemysłowych zastosowaniach punktu rosy, takich jak sprężone powietrze, gaz Sf6, _cc781905 -5cde-3194-bb3b-136bad5cf58d_obróbka metali, produkcja addytywna oraz suszenie żywności i tworzyw sztucznych. Zalety-: Dokładny measurement i szybki czas pomiaru. Cyfrowy wyświetlacz zapewnia dokładny odczyt przy minimalnym błędzie Szeroki zakres pomiarowy i wysoka rozdzielczość. Ostatnie wartości / Maks. Wartości / min. wartości zarówno wilgotność, jak i temperatura zostaną automatycznie zapisane w pamięci i mogą zostać wyświetlone. Zastosowanie trwałych, trwałych komponentów, w tym mocnej, lekkiej obudowy z tworzywa ABS, zapewnia bezobsługową pracę przez wiele lat. Obudowa została starannie wyprofilowana, aby wygodnie leżała w obu dłoniach. Skontaktuj się z nami Miernik punktu rosy SF6 ( KPM DPM-01) Specyfikacja techniczna -: KPM-DPM-01 przyjmuje importowany pojemnościowy czujnik wilgotności z folii i technologię mikrokomputerową. It został opracowany jako inteligentny przyrząd do pomiaru śladów wilgoci o dobrych parametrach. Jego obsługa jest prosta i posiada funkcję konwersji między Td, RH, PPM i aktualizacją oprogramowania. Detektor może być używany do pomiaru wilgotności powietrza, w tym powietrza, azotu, gazu obojętnego i dowolnego powietrza niezawierającego środowiska korozyjnego, w szczególności do pomiaru wilgotności powietrza SF6. Cechy Samoczynna kalibracja punktu zerowego i nachylenia po uruchomieniu, kalibracja punktu rosy metodą pojedynczego punktu dla pełnego zakresu (technologia patentowa) Unikalna konstrukcja obwodu gazowego, dobra gazoszczelność i przepuszczalność, wodoodporność. Duży ekran ciekłokrystaliczny TFT wyświetla wartość punktu rosy i odpowiednią względną wilgotność względną Wartość wilgotności, wartość wilgotności PPM Przechowywanie i kwerenda danych pomiarowych Inteligentny monit o zasilanie, inteligentna ochrona ładowania Bateria litowa zapewnia długi czas czuwania zasilania Skontaktuj się z nami Często zadawane pytania ( FAQ ) FAQ about SF6 GAS testing : 01 Is SF6 Gas Testing: Health, Safety, and Environmental Implications? Sulfur hexafluoride (SF₆) is widely used as an insulating and arc-quenching gas in high-voltage switchgear due to its excellent dielectric properties. However, SF₆ is a potent greenhouse gas, with a global warming potential over 23,000 times that of CO₂. Hence, rigorous testing and handling are essential for environmental compliance and personnel safety. Key SF₆ tests include moisture content, purity, and decomposition products (like SO₂ and HF), which help detect gas leakage, contamination, or insulation failure. Exposure to decomposition byproducts can pose health hazards such as respiratory irritation or chemical burns, necessitating strict handling protocols and personal protective equipment (PPE). KPM offers advanced SF₆ gas analyzers that measure purity, moisture, and decomposition gases in accordance with IEC 60376 and 60480 standards. With portable, user-friendly designs and accurate sensors, KPM’s instruments support safe operation, environmental responsibility, and preventive maintenance of gas-insulated systems. 02 What Is a Dew Point Meter and Why Is It Essential for SF6 Systems? A dew point meter is a device that measures the dew point, the temperature at which air becomes saturated and water vapour condenses into liquid water. In SF6 (sulfur hexafluoride) systems, dew point meters are crucial for monitoring moisture levels, as even small amounts of water can lead to hydrolysis, forming corrosive byproducts like hydrofluoric acid, which damage insulation and metal components. Excess moisture can also reduce the dielectric strength of SF₆, increasing the risk of flashovers and system failures. Regular dew point monitoring ensures that SF₆ gas remains dry and stable, extending the lifespan of high-voltage equipment like GIS (Gas Insulated Switchgear). KPM's Dew Point Meters provide fast, accurate, and reliable measurements, with robust sensors designed for field and laboratory use. These meters help utilities maintain safety, reliability, and regulatory compliance, making them an essential part of preventive maintenance in SF₆ systems. 03 What is PQ analyzer , how it is different than Power recorders ? A Power Quality Analyzer and a Power Recorder may appear similar at first glance, but they serve distinct purposes in electrical diagnostics and monitoring. A Power Quality Analyzer is specifically designed to detect, analyze, and troubleshoot disturbances in the power system such as voltage sags, swells, transients, harmonics, flicker, unbalance, and frequency deviations. These analyzers are equipped with high-speed sampling capabilities, waveform capture, and harmonic spectrum analysis tools, making them ideal for identifying and resolving issues that can affect the performance or lifespan of sensitive electrical equipment. They are also commonly used for compliance monitoring against standards like EN 50160 or IEEE 519. In contrast, a Power Recorder is primarily used for long-term logging of power parameters such as voltage, current, power (kW, kVA, kVAR), and energy consumption. Its focus is more on load studies, energy audits, and identifying usage patterns over time rather than real-time disturbances or quality issues. Power Recorders usually measure and log RMS values at set intervals and are not typically equipped to detect fast transients, harmonics, or waveform-level events. While some overlap exists—many modern Power Quality Analyzers also offer recording functionality—the key difference lies in the depth of analysis. A Power Quality Analyzer is a diagnostic tool used when there’s a suspected problem or for verifying power quality compliance, whereas a Power Recorder is more of a monitoring tool for tracking energy use and system loading trends over time. 04 How Harmonics Affect Transformer Performance? Effects of Harmonics on Transformer Performance Increased Heating (Core and Copper Losses): Harmonics cause additional eddy current and hysteresis losses in the transformer core and I²R losses in the windings due to the skin effect and proximity effect. This leads to excessive heating, even when the transformer is operating within its rated current. This can reduce transformer lifespan or even cause thermal failure. Reduced Efficiency: As harmonic losses increase, the overall efficiency of the transformer drops. It may appear to be operating under normal conditions in terms of RMS values, but real power losses are higher. Derating of Transformer: To compensate for the increased losses due to harmonics, transformers are often derated (i.e., used at less than their nameplate capacity) when supplying non-linear loads. IEEE Std C57.110 provides guidelines for calculating the required derating. Increased Vibration and Noise: Harmonics can cause magnetostriction effects in the transformer core, resulting in audible noise and mechanical vibration, which can be especially problematic in sensitive environments. Insulation Stress and Aging: Repeated thermal cycling due to harmonic-induced heating stresses the insulation system, accelerating insulation degradation and reducing transformer life expectancy. Neutral Overload (in 3-phase systems): In systems with significant triplen harmonics (3rd, 9th, 15th...), these components add arithmetically in the neutral conductor. This can cause the neutral to overheat, even if the phase conductors are within limits. Incorrect Protective Relay Operation: Harmonic distortion can interfere with current and voltage sensing used in protective relays, leading to nuisance tripping or failure to trip during faults. 05 What are Real-World Applications of PQ Recorders? Real-World Applications of Power Quality (PQ) Recorders 1. Load Profiling and Energy Audits PQ recorders are commonly used to monitor energy consumption patterns over time. This helps identify peak demand periods, base loads, and inefficiencies, supporting energy optimization and cost savings. 2. Electrical System Commissioning During commissioning of new installations—such as switchboards, transformers, or generators—PQ recorders verify voltage levels, current balance, and overall system performance to ensure proper operation. 3. Capacity Planning and Expansion Before adding new electrical loads, PQ recorders assess whether existing infrastructure can support the additional demand. This prevents overloading and supports informed upgrade decisions. 4. Renewable Energy Integration In solar and wind power systems, PQ recorders monitor output stability, voltage, and frequency to ensure grid compliance and smooth integration with the main supply. 5. Troubleshooting Intermittent Issues When power issues such as flickering, nuisance tripping, or undervoltage occur, PQ recorders help log and analyze events that may not be immediately visible during spot checks. 6. Utility Billing Verification PQ recorders provide accurate data for verifying utility charges, particularly demand-based billing and power factor penalties, helping avoid disputes or overcharges. 7. Temporary Power Monitoring For construction sites, events, or mobile power setups, PQ recorders ensure temporary supplies are stable, safe, and suitable for operational requirements. 8. Preventive Maintenance and Trend Analysis Long-term monitoring enables early detection of issues like increasing unbalance or loading trends, allowing for proactive maintenance before failures occur. 06 What are the Benefits of 24/7 Power Quality Monitoring? Benefits of 24/7 Power Quality Monitoring : 1. Continuous Visibility Real-time tracking of voltage, current, harmonics, and disturbances ensures you always have a clear picture of system health — without waiting for issues to escalate. 2. Early Fault Detection Continuous monitoring helps detect developing issues like transformer overload, harmonic distortion, or voltage imbalance before they cause damage or downtime. 3. Minimizes Unplanned Downtime By identifying power disturbances early, 24/7 PQ monitoring reduces the risk of equipment failure, production loss, or service interruption. 4. Improves Equipment Lifespan Stable power quality reduces stress on motors, drives, UPS systems, and sensitive electronics — extending their service life and reducing maintenance costs. 5. Supports Root Cause Analysis Historical event logs and waveform captures make it easier to trace the cause of faults, helping engineers respond faster and more accurately. 6. Compliance & Reporting Automated recording helps meet regulatory standards (e.g., EN 50160, IEEE 519) and supports internal audits or external quality reports. 7. Energy Efficiency Optimization By continuously monitoring power factor, load balance, and harmonic content, users can implement corrective actions to reduce losses and improve system efficiency. 8. Informs Investment Decisions Reliable long-term data helps justify infrastructure upgrades, sizing of backup systems, or addition of filters and stabilizers.

  • advertisements | KPM Engineering Solutions Pvt. Ltd.|Advertisements

    In KPM Engineering Solution Pvt. Ltd our solutions are Thermal Imager camera, fever monitoring solution, Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing , Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing. Visit www.kpmtek.com for details SPRZĘT DO TESTOWANIA PODSTACJI - REKLAMA All Videos All Videos Odtwórz Wideo Udostępnienia Cały kanał Ten film Facebook Twitter Pinterest Tumblr Skopiuj link Link skopiowany Search videos Wyszukaj film... Teraz Odtwarzane KPM KFA320 00:35 Odtwórz Wideo Teraz Odtwarzane KPM intro (M) 01:16 Odtwórz Wideo Teraz Odtwarzane KPM India - Your Reliable Electrical Test Equipment Solution Provider 01:20 Odtwórz Wideo

  • PD Detector (Analog) | KPM India |PD Detector (Analog)

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Detector (Analog) |https://kpmtek.wixsite.com/website/pl/pd-detector-analog Detektor wyładowań niezupełnych (analogowy)

  • CT/PT Testing Kit by KPM | Current & Potential Transformer Testing|CT/PT Testing

    KPM CT/PT testing kits deliver accurate and reliable current and potential transformer testing for industrial and electrical applications. ZESTAWY DO TESTOWANIA CT I PT Analizator CT/PT CT/PT Analyzer C+ KPM-CT/PT Analyzer to kompleksowe rozwiązanie do testowania wszystkich typów CT/PT zgodnie z normami IEC. Jest to sprzęt o wysokim ROI (Return On Investment). Below features make KPM CT/PT analyzer and ideal tool for_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Producent CT/PT, laboratoria badawcze, podstacje (do 765 kV), elektrownie itp. Cechy Low Testing Time _cc781905-5cde -3194-bb3b-136bad5cf58d_ (Completes all test for CT/PT _cc781905-5cde -3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb3b- 136bad5cf58d_ _cc781905-5cde- 3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb 3b-136bad5cf58d_ _cc781905- 5cde-3194-bb3b-136bad5cf58d_ Winding & Cores in few min) Simple connection _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (proste jednorazowe połączenie) Highest Accuracy _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (0.05% for turns ratio & winding resistance ) Przenośny i lekki (<15KG) Wysoka odporność na zakłócenia (może być używana w rozdzielniach pod napięciem 220/400/765 KV ) Zestaw wtrysku prądu pierwotnego KPM APIK 2000 To urządzenie do testowania podstacji jest przeznaczone do zapewniania wysokiego prądu wyjściowego, gdy jest to potrzebne podczas uruchamiania podstacji. Seria urządzeń KPM PIK ma następujące cechy: Wysoki prąd wyjściowy do 8000 A Moc wyjściowa do 35 kVA Indywidualny projekt. Przeznaczony do pierwotnego testowania wtryskowego przekaźników zabezpieczeniowych i wyłączników automatycznych, do uruchamiania i modernizacji podstacji i sieci elektrycznej Modułowa konstrukcja ułatwiająca transport Bieg ciepła. CT/PT Pro CT/PT Pro KPM-CT/PT Pro is an automatic device used for testing of instrument transformatory metodą stosunku napięcia . CT/PT Pro jest w stanie przeprowadzić poniższe testy zarówno na CT, jak i PT 1) Turns Ratio (błąd współczynnika i błędy fazy) 2) Wykreślanie krzywej wzbudzenia 3) Rezystancja uzwojenia 4) Obciążenie wtórne CT 3) polaryzacja Dane techniczne -: Najwyższy zwrot z inwestycji z niespotykaną dotąd propozycją wartości . Łatwy w obsłudze. KPM-CT PT Pror automatycznie kończy test i generuje raport . Maksymalne napięcie wyjściowe 2000V do badania charakterystyki wzbudzenia HVCTR (tester współczynnika WN CT) CTR Tester przekładni przekładników prądowych wysokiego napięcia online (KPM-HVCTR) — Tester przekładni przekładników prądowych wysokiego napięcia Jak sama nazwa wskazuje Online HV CT Ratio Tester (KPM-HVCTR) is innowacyjny_cc781905-5cde-3194-bb3b-136bad5cf50_7 -136bad5cf58d_ parametry linii / CT systemu upto 33KV. Online HV CT Ratio Tester (KPM-HVCTR) służy do określania: Pomiar prądu pierwotnego i wtórnego Aktualny współczynnik transformacji Sekwencja faz Biegunowość Analizator CT/PT CT/PT Analyzer KPM-CT/PT Analyzer to kompleksowe rozwiązanie do testowania wszystkich typów CT/PT zgodnie z normami IEC. Jest to sprzęt o wysokim ROI (Return On Investment). Below features make KPM CT/PT analyzer and ideal tool for_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Producent CT/PT, laboratoria badawcze, podstacje (do 765 kV), elektrownie itp. Cechy Low Testing Time _cc781905-5cde -3194-bb3b-136bad5cf58d_ (Completes all test for CT/PT _cc781905-5cde -3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb3b- 136bad5cf58d_ _cc781905-5cde- 3194-bb3b-136bad5cf58d_ _cc781905-5cde-3194-bb 3b-136bad5cf58d_ _cc781905- 5cde-3194-bb3b-136bad5cf58d_ Winding & Cores in few min) Simple connection _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (proste jednorazowe połączenie) Highest Accuracy _cc781905-5cde-3194 -bb3b-136bad5cf58d_ (0.05% for turns ratio & winding resistance ) Przenośny i lekki (<15KG) Wysoka odporność na zakłócenia (może być używana w rozdzielniach pod napięciem 220/400/765 KV ) Zestaw wtrysku prądu pierwotnego PIK To urządzenie do testowania podstacji jest przeznaczone do zapewniania wysokiego prądu wyjściowego, gdy jest to potrzebne podczas uruchamiania podstacji. Seria urządzeń KPM PIK ma następujące cechy: Wysoki prąd wyjściowy do 8000 A Moc wyjściowa do 35 kVA Indywidualny projekt. Przeznaczony do pierwotnego testowania wtryskowego przekaźników zabezpieczeniowych i wyłączników automatycznych, do uruchamiania i modernizacji podstacji i sieci elektrycznej Modułowa konstrukcja ułatwiająca transport Bieg ciepła. HVCTR (tester współczynnika WN CT) HVCTR Tester przekładni przekładników prądowych wysokiego napięcia online (KPM-HVCTR) — Tester przekładni przekładników prądowych wysokiego napięcia Jak sama nazwa wskazuje Online HV CT Ratio Tester (KPM-HVCTR) is innowacyjny_cc781905-5cde-3194-bb3b-136bad5cf50_7 -136bad5cf58d_ parametry linii / CT systemu upto 33KV. Online HV CT Ratio Tester (KPM-HVCTR) służy do określania: Pomiar prądu pierwotnego i wtórnego Aktualny współczynnik transformacji Sekwencja faz Biegunowość Porównanie — analizator CT PT i CT PT Pro Wideo - Analizator CT/PT CT/PT Videos KPM CT PT Testing Videos KPM CT PT Testing Videos Odtwórz Wideo Udostępnienia Cały kanał Ten film Facebook Twitter Pinterest Tumblr Skopiuj link Link skopiowany Search videos Wyszukaj film... Teraz Odtwarzane Unboxing LA Tester , KPM LA 103+ 03:45 Odtwórz Wideo Teraz Odtwarzane KPM TAN DELTA - 12 KV (https://www.kpmtek.com/tandelta) 01:27 Odtwórz Wideo Teraz Odtwarzane UNBOXING RELAY TEST KIT - KINGSINE K3063I 05:50 Odtwórz Wideo Teraz Odtwarzane Testing Tan Delta in 765kV Live Switchyard 00:43 Odtwórz Wideo Teoria - Testy CT/PT CT PT Theory CT (przekładnik prądowy) – Teoria Jak każdy inny transformator, przekładnik prądowy ma uzwojenie pierwotne, rdzeń magnetyczny i uzwojenie wtórne. Prąd przemienny płynący w uzwojeniu pierwotnym wytwarza zmienne pole magnetyczne w rdzeniu, które następnie indukuje prąd przemienny w obwodzie uzwojenia wtórnego. Podstawowym celem projektowania przekładników prądowych jest zapewnienie wydajnego sprzężenia obwodów pierwotnego i wtórnego, tak aby prąd wtórny miał dokładny związek z prądem pierwotnym. PT (Transformator Potencjalny) – Teoria Teoria transformatora napięcia lub teoria transformatora potencjału jest podobna do teorii transformatora obniżającego napięcie ogólnego przeznaczenia. Pierwotny tego transformatora jest podłączony przez fazy lub uziemienie, w zależności od wymagań. Podobnie jak transformator, służący do obniżania napięcia, transformator potencjału, tj. PT, ma dolne zwoje na uzwojeniu wtórnym. Napięcie systemowe jest przykładane do zacisków uzwojenia pierwotnego tego transformatora, a następnie proporcjonalne napięcie wtórne pojawia się na zaciskach wtórnych PT. Testy CT/PT Poniżej znajduje się lista głównych testów przeprowadzonych na CT i PT Test rezystancji izolacji Test polaryzacji Test rezystancji wtórnej/pętli Test obciążenia (test opcjonalny) Test krzywej magnesowania (test opcjonalny) Test krzywej histerezy Test współczynnika skrętu (test opcjonalny) Podstawowy test wtrysku Próba wysokiego napięcia Często zadawane pytania ( FAQ ) FAQ - CT PT Analyzer FAQ about all our CT/PT products : 01 Jakie typy przekładników prądowych można testować za pomocą analizatora KPM CT PT? Analizator KPM CT PT jest w stanie przetestować prawie wszystkie rodzaje CT i PT, w tym pomiarowe i ochronne CT. Jeśli chodzi o zastosowania, wszystkie typy przekładników prądowych stosowane w dystrybucji, przesyłaniu i wytwarzaniu energii elektrycznej mogą być testowane za pomocą analizatora KPM CT/PT Analyzer. Testerem mogą być również przekładniki prądowe do zastosowań specjalnych, takie jak CT pierścienia szynowego, CT tulei transformatora. KPM CT PT Analyzer może testować PT i CVT również przy użyciu akcesorium wzmacniającego napięcie . 02 Czy KPM CT PT Analyzer może testować przekładniki prądowe kanałów szynowych generatora? Tak Analizator KPM CT PT może perfekcyjnie testować przekładniki prądowe generatora szyny kanałowej. 03 Czy KPM CT PT Analyzer może testować przekładniki prądowe przepustów transformatora mocy ? Tak, KPM CT PT Analyzer testuje przekładniki prądowe przepustowe transformatora mocy z perfekcją . 04 Dlaczego testowanie CT przepustu transformatora mocy jest złożoną sprawą dla każdego sprzętu do testowania CT? Analizator KPM CT PT działa na zasadzie metody stosunku napięć. Podczas testowania przekładnika prądowego transformatora mocy obwód pierwotny jest połączony szeregowo z uzwojeniem transformatora mocy, co sprawia, że testowanie jest skomplikowane. Analizator KPM CT PT za pomocą obwodów redukcji szumów jest w stanie perfekcyjnie przetestować przekładniki prądowe przepustowe transformatora mocy. 05 Jaki jest najwyższy punkt kolana badany przez KPM CT PT Analyzer . KPM CT PT Analyzer nasyca rdzeń CT z wysokim punktem przegięcia, stosując zasadę redukcji częstotliwości. Tak więc praktycznie może testować punkt kolanowy wszystkich typów przekładników prądowych ochrony EHV za pomocą źródła niskiego napięcia. Teoretycznie może przetestować punkt kolanowy nawet 35 kV. 06 Czy analizator KPM CT PT jest przenośny? Analizator KPM CT PT jest bardzo przenośny dzięki rozmiarowi (szer. x wys. x gł.) w mm 485 x 356 x 183 i wadze < 15 kg. To sprawia, że jest to idealny sprzęt do podróżowania. 07 Którzy klienci z sektora energetycznego używają analizatora KPM CT PT KPM CT PT Analyzer jest używany przez wszystkich klientów, którzy zajmują się wytwarzaniem, przesyłem oraz dystrybucją energii. 08 Czy możemy zmierzyć rezystancję pierwotną i wtórną PT za pomocą analizatora KPM CT PT Rezystancja uzwojenia pierwotnego PT jest wyrażona w kohmach. KPM CT PT Analyzer posiada zakres rezystancji w Kohmach, za pomocą którego w łatwy sposób można sprawdzić rezystancję pierwotną PT. Rezystancja wtórna PT jest wyrażona w omach, co można łatwo sprawdzić. 09 Czy możemy uzyskać krzywą histerezy CT za pomocą analizatora KPM CT PT Tak Analizator KPM CT PT ma funkcję krzywej histerezy. Pod koniec testu obliczana jest krzywa histerezy przekładnika prądowego, która wyraźnie pokazuje charakterystykę utraty mocy testowanego przekładnika prądowego. 10 Co to jest krzywa histerezy i jakie jest jej znaczenie Namagnesowanie substancji ferromagnetycznych spowodowane zmiennym polem magnetycznym pozostaje w tyle za polem. Efekt ten nazywa się histerezą, a termin ten jest używany do opisania każdego systemu, którego reakcja zależy nie tylko od jego obecnego stanu, ale także od jego przeszłej historii. W KPM CT PT Analyzer obliczana jest krzywa histerezy przekładnika prądowego. Szerokość krzywej histerezy wyraźnie pokazuje charakterystykę strat mocy badanego przekładnika prądowego. 11 W jaki sposób analizator KPM CT PT może automatycznie znaleźć wartość rezystancji uzwojenia przy 75°C. Analizator KPM CT PT posiada wbudowany czujnik temperatury, za pomocą którego mierzy temperaturę pokojową w czasie pomiaru rezystancji uzwojeń. Po zakończeniu pomiaru pokazuje wartość rezystancji uzwojenia w temperaturze pokojowej oraz skompensowaną temperaturę rezystancji uzwojenia wartość @ 75'C automatycznie. Zmniejsza to ryzyko błędu ludzkiego związanego z ręcznym wprowadzaniem danych o temperaturze . 12 Co to jest test obciążenia wtórnego CT i jakie jest jego znaczenie Wszystkie typy CT i PT są zaprojektowane do stałego obciążenia obciążenia do obsługi. Jeśli podłączone obciążenie przekładnika prądowego jest większe niż wymagane obciążenie, wówczas wyjście przekładnika prądowego nie będzie zgodne ze specyfikacją i zostanie wprowadzony błąd. Analizator KPM CT PT ma funkcję testowania obciążenia, w której analizator KPM CT PT znajduje VA całej pętli przewodnika. 13 Jakie badanie można przeprowadzić za pomocą analizatora KPM CT PT? Poniższy test można przeprowadzić na CT i PT przy użyciu analizatora KPM CT / PT Testy przekładnika prądowego: Test krzywej wzbudzenia i parametrów Test współczynnika obrotów Test współczynnika i błędu fazy Sprawdzanie oznaczenia biegunowości Pomiar rezystancji cewki Pomiar obciążenia pętli wtórnej Test krzywej linii błędu dla przekładnika prądowego ochrony Test parametrów przejściowych CT Zgadnij tabliczkę znamionową CT Pomiar krzywej pętli histerezy nasycenia Testy przekładnika napięciowego: Test przełożenia i błędu kąta fazowego Test polaryzacji Test dodatkowego obciążenia Test rezystancji uzwojenia

  • test | KPM India |test

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|test |https://kpmtek.wixsite.com/website/pl/about-1 Heading 1 Heading 2 Heading 3 Heading 4 I'm a paragraph. Click here to add your own text and edit me. It's easy. I'm a paragraph. Click here to add your own text and edit me. It's easy. Maximum ROI

  • PD - HV Lab | KPM Engineering Sol.|PD - HV Lab

    Expert high voltage testing and partial discharge (PD) analysis. KPM advanced HV lab provides precise diagnostic services to ensure insulation integrity and equipment reliability. Detektor wyładowań niezupełnych NON PD Capacitive Voltage Divider_edited Non PD Capacitive Voltage Divider KPM Non PD Transformer Non PD Test Transformer Calibrator PD Calibrator Non PD Coupling Capacitor01 Non PD Coupling Capacitor Motor driven contact type voltage regular Motor driven contact Motor driven contact type voltage regula Motor driven contact type voltage regular Measuring Impedance Measuring Impedance Intermediate Transformer Intermediate transformer KPM PDA-01 Digital PD Monitor KPM PDM-01 Analog PD Monitor KPM Current Input unit High Current Input Unit

  • Tap Changer Testing Equipment by KPM | Transformer Testing|Tap Changer Testing

    Advanced tap changer testing equipment by KPM for precise diagnostics, condition monitoring, and maintenance of transformer tap changers. ANALIZATOR PRZEŁĄCZNIKA ZACZEPÓW POD OBCIĄŻENIEM (OLTC). Zobacz więcej Skontaktuj się z nami Analizator przełącznika zaczepów KPM Analizator przełącznika zaczepów pod obciążeniem transformatora to połączenie Timer przejścia & Tester rezystancji uzwojenia. KPM Transformer analizator podobciążeniowych przełączników zaczepów to wszechstronne urządzenie pomiarowe do pomiaru i analizy wskaźników wydajności elektrycznej transformatorów mocy i specjalnych przełączników zaczepów pod obciążeniem w systemy zasilania. Przyjmuje sterowanie mikrokomputerem, a dzięki zaprojektowaniu precyzyjnego obwodu pomiarowego może realizować dokładny pomiar czasu przejścia, kształtu fali przejścia, rezystancji przejścia i synchronizacji trójfazowej włączenia -obciążenie przełącznika zaczepów. Użytkownik może przetestować przełącznik zaczepów z i bez uzwojenia transformatora. Przyrząd posiada funkcje wyświetlania, analizy, przechowywania i drukowania zmierzonych danych. Możliwa jest diagnoza potencjalnej awarii przełącznika zaczepów pod obciążeniem w teście prewencyjnym urządzeń elektroenergetycznych i przeglądzie transformatora, co ma ogromne znaczenie dla poprawy niezawodności pracy systemu elektroenergetycznego. Parametry techniczne 1> prąd wyjściowy: 1,0 a, 0,5 a, 0,3 a 2> Zakres rezystancji: 1,0 A bieg 0,1 ~ 10 Ω, 0,5 A bieg 5 ~ 20 Ω, 0,3 A bieg 10 ~ 40 Ω 3> Dokładność pomiaru rezystancji: 0,1 Ω ~ 1 Ω ± 0,1 Ω, 1 Ω ~ 40 Ω ± 1% (bez 1 Ω) 4> Pomiar czasu przejścia: zakres 1 ~ 250 ms, dokładność: 1 ms ~ 100 ms ± 0,1 ms 100 ms ~ 250 ms ± 1% 5> Częstotliwość próbkowania: 10 ~ 20 KHz 6> synchronizacja trójfazowa: 0,01 ms 7> Temperatura pracy: 0 ~ 40 ° C 8> Wilgotność otoczenia: ≤90% RH, bez kondensacji 9> Wymiary (mm): 420 × 350 × 220, waga: 12 kg (wraz z akcesoriami)

  • Voltage Regulator (ContactType) | KPM India |Voltage Regulator (ContactType)

    KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|Voltage Regulator (ContactType) |https://kpmtek.wixsite.com/website/pl/voltageregulator-contacttype Regulator napięcia (typ styku)

  • Test Lab Infra | KPM Engineering Solutions Pvt. Ltd.|Test Lab ( Infra )

    In KPM Engineering Solution Pvt. Ltd our solutions are Thermal Imager camera, fever monitoring solution, Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing , Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing. Visit www.kpmtek.com for details LABORATORIUM INFRA

bottom of page