Search Results
83 Ergebnisse gefunden mit einer leeren Suche
- Servicesupport
In KPM Engineering Solution Pvt. Ltd our solutions are Thermal Imager camera, fever monitoring solution, Relay Test Kit, CT/PT Analyzer, Oil BDV, Transformer Testing , Circuit Breaker Testing, LA Testing, Ground Testing, Partial Discharge Testing. Visit www.kpmtek.com for details Technical support and services Localized Service Center A Key to Success for Hi-Tech Equipment Providers Relay Test Kits CT/PT Analyzers Tan Delta Kits And other advanced diagnostic instruments. With local spare parts availability, we ensure fast turnaround times and reliable repairs, resulting in minimal downtime and maximum customer satisfaction. At KPM, we believe that a localized service center is crucial to the success of any high-tech equipment provider. We take pride in operating a state-of-the-art service center with over 10 years of experience in the repair and maintenance of critical testing equipment, including: Contact Us
- KPM| Transformer Test Equipment | tandelta, twrt, ttr, oilbdv|Transformer Testing
Our transformer testing equipment consist of -: Tan Delta Kit, Winding Resistance Kit,Turns Ratio Kit, IR Testers (5 KV to 25KV ), OIL BDV Test Kits. TRANSFORMATOR PRÜFSET Video FAQ Theorie Hellbrauner Delta-Tester Mehr sehen KPM TD-12 ist ein einfaches und robustes Gerät für PF/DF-Messungen von -: Leistungstransformatoren Rotierende Maschinen Stromtransformatoren Spannungswandler Hochspannungskabel (HV). Gasisolierte Schaltanlagen (GIS)-Systeme KPM TD-12 ist mit Hilfe seines speziellen Designs in der Lage, Tan-Delta-Tests in hochbelasteten Umspannwerkumgebungen bis zu 765 kV durchzuführen. Einige wichtige Punkte Testen bei 10 kV/12 kV mit 0,1-kV-Schritten Freq @45HZ/55HZ , 47.5HZ/52.5HZ, 55HZ/65HZ, 57.5HZ/62.5HZ, Automatic doppelte Frequenz Leistungsstarkes Gerät mit 2000 VA Das Instrument verfügt über viele Schutzmaßnahmen, wie z. B. Eingangsspannungsschwankung, Ausgangskurzschluss, Überspannung, Überstrom und Übertemperatur. KPM TD 12 mit Hilfe von optionalem Zubehör kann Tan Delta von -: testen Transformatoröl mit Hilfe von Oil Test Cell Generatoren mit hoher Kapazität . Bitte wenden Sie sich für weitere Informationen an . IR-Tester Mehr sehen KPM-5KP is an easy to use 5KV IR Tester with user selectable voltage ranges 500V,1000V,2500V,5000V._cc781905-5cde- 3194-bb3b-136bad5cf58d_ Es eignet sich zum Messen der Isolierung von Schaltanlagen, Paneelen, Schaltanlagen, Hochspannungsmotoren, Hochspannungsgeneratoren Kondensatoren, Stromkabel, Überspannungsableiter und andere ideale Prüfgeräte für den Isolationswiderstand. Hauptmerkmale-: PI/DAR-Einrichtung Kurzschlussstrom <1mA Automatische Entladungsfunktion, um den Betrieb sicher zu machen. Fortschrittliche „Guard“-Funktion für genaue Messungen Warnsymbole für Stromkreise mit Audiotönen. Geeignet für funktionierendes 12V DC-Netzteil (12V/1A) oder internen Akku Windungsverhältnis Tester Mehr sehen KPM-TTR3 ist ein dreiphasiger Transformatorverhältnistester zur Messung des Spannungsverhältnisses von 3- oder 1 Phasentransformatoren. Alle Daten und Testergebnisse werden auf einem 320*240 LCD angezeigt. Alle Testergebnisse können vor Ort mit dem Mikrodrucker ausgedruckt werden. KPM-TTR3 hat einen eingebauten Speicher zum Speichern der Testergebnisse. Die erweiterte Rauschunterdrückungsschaltung macht das KPM-TTR3 zu einem idealen Gerät für Feldbedingungen. Transformatorwicklungswiderstandsprüfer (1 Phase) Mehr sehen KPM bietet ein komplettes Sortiment an Prüfgeräten für Transformatoren an. TWRT-2A (2A, 1-Phasen-Test) TWRT-10A (10A, 1-Phasen-Test) TWRT-20A (20A, 1-Phasen-Test) TWRT-40A (40A, 1-Phasen-Test) TWRT-20 ( 40A , 1 Phase Testing & 20A, 3Phase Testing ) . SFRA & Sht. CKt. Impedanz Mehr sehen Leistungstransformatoren sind ein wichtiges elektrisches Gerät, dessen sicherer und zuverlässiger Betrieb für Stromversorgungssysteme äußerst wichtig ist. KPM SFRA+ wurde entwickelt, um die mechanische und elektrische Integrität von Leistungstransformatoren nach dem Transport oder nach Einwirkung hoher Fehlerströme zu prüfen. Es verwendet die SFRA-Prinzip (Sweep Frequency Response Analysis) Sht. Ckt. Impedanzmethode & misst die elektrische Übertragungsfunktion über einen breiten Frequenzbereich. Hellbrauner Delta-Tester Mehr sehen KPM TD-12 ist ein einfaches und robustes Gerät für PF/DF-Messungen von -: Leistungstransformatoren Rotierende Maschinen Stromtransformatoren Spannungswandler Hochspannungskabel (HV). Gasisolierte Schaltanlagen (GIS)-Systeme KPM TD-12 ist mit Hilfe seines speziellen Designs in der Lage, Tan-Delta-Tests in hochbelasteten Umspannwerkumgebungen bis zu 765 kV durchzuführen. Einige wichtige Punkte Testen bei 10 kV/12 kV mit 0,1-kV-Schritten Freq @45HZ/55HZ , 47.5HZ/52.5HZ, 55HZ/65HZ, 57.5HZ/62.5HZ, Automatic doppelte Frequenz Leistungsstarkes Gerät mit 2000 VA Das Instrument verfügt über viele Schutzmaßnahmen, wie z. B. Eingangsspannungsschwankung, Ausgangskurzschluss, Überspannung, Überstrom und Übertemperatur. KPM TD 12 mit Hilfe von optionalem Zubehör kann Tan Delta von -: testen Transformatoröl mit Hilfe von Oil Test Cell Generatoren mit hoher Kapazität . Bitte wenden Sie sich für weitere Informationen an . IR-Tester Mehr sehen KPM-5KP is an easy to use 5KV IR Tester with user selectable voltage ranges 500V,1000V,2500V,5000V._cc781905-5cde- 3194-bb3b-136bad5cf58d_ Es eignet sich zum Messen der Isolierung von Schaltanlagen, Paneelen, Schaltanlagen, Hochspannungsmotoren, Hochspannungsgeneratoren Kondensatoren, Stromkabel, Überspannungsableiter und andere ideale Prüfgeräte für den Isolationswiderstand. Hauptmerkmale-: PI/DAR-Einrichtung Kurzschlussstrom <1mA Automatische Entladungsfunktion, um den Betrieb sicher zu machen. Fortschrittliche „Guard“-Funktion für genaue Messungen Warnsymbole für Stromkreise mit Audiotönen. Geeignet für funktionierendes 12V DC-Netzteil (12V/1A) oder internen Akku OIL BDV-Testkit Mehr sehen Wie der Name schon sagt, wird das Oil BDV Test Set (KPM-OBD80/100+) zur Messung der Durchschlagfestigkeit des Isolieröls verwendet. Kann mit integriertem Drucker 80/100 kV erzeugen. Motorisierter & programmierter Rührer Geringes Gewicht 5 kV/s Spannungsanstieg mit automatischen Testplänen gemäß IEC & IS 0.5KV/sec to 5KV/sec variable voltage rise as per ASTM Standards ( available in "A+"_cc781905-5cde-3194-bb3b- 136bad5cf58d_ Modelle) SFRA & Sht. CKt. Impedanz Mehr sehen Leistungstransformatoren sind ein wichtiges elektrisches Gerät, dessen sicherer und zuverlässiger Betrieb für Stromversorgungssysteme äußerst wichtig ist. KPM SFRA+ wurde entwickelt, um die mechanische und elektrische Integrität von Leistungstransformatoren nach dem Transport oder nach Einwirkung hoher Fehlerströme zu prüfen. Es verwendet die SFRA-Prinzip (Sweep Frequency Response Analysis) Sht. Ckt. Impedanzmethode & misst die elektrische Übertragungsfunktion über einen breiten Frequenzbereich. SFRA & Sht. CKt. Impedanz Mehr sehen Leistungstransformatoren sind ein wichtiges elektrisches Gerät, dessen sicherer und zuverlässiger Betrieb für Stromversorgungssysteme äußerst wichtig ist. KPM SFRA+ wurde entwickelt, um die mechanische und elektrische Integrität von Leistungstransformatoren nach dem Transport oder nach Einwirkung hoher Fehlerströme zu prüfen. Es verwendet die SFRA-Prinzip (Sweep Frequency Response Analysis) Sht. Ckt. Impedanzmethode & misst die elektrische Übertragungsfunktion über einen breiten Frequenzbereich. Video – Prüfung von Leistungstransformatoren Video - Power Transformer Testing 765KV live switchyard ,Tan Delta Testing of Grading Capacitors Video abspielen CT PT Analyzer Video abspielen Power of 90' Rotational view , thermal imager camera Video abspielen 765KV live switchyard ,Tan Delta Testing of Grading Capacitors Video abspielen CT PT Analyzer Video abspielen Facebook Twitter Pinterest Tumblr Link kopieren Link kopiert Schließen Theory Power Transformer Testing Theorie - Prüfung von Leistungstransformatoren Hochspannungstransformatoren gehören zu den wichtigsten (und teuersten) Ausrüstungsgegenständen, die für den Betrieb eines Stromversorgungssystems erforderlich sind. Beim Zusammenbau des Transformators in der Umspannstation werden eine Vielzahl von Prüfungen und Tests durchgeführt. Der Testingenieur führt möglicherweise nicht alle folgenden Tests und Inspektionen direkt durch, muss aber sicher sein, dass sie zufriedenstellend abgeschlossen sind um eine endgültige Entscheidung über den Transformator zu treffen Bereitschaft der Bank, energetisiert zu werden. IR-Tests Kapazität & Tan Delta Widerstandstester für Transformatorwicklungen Transformator Windungsverhältnis Magnetischer Gleichgewichtstest des Transformators Magnetisierungsstromtest des Transformators Vektorgruppentest des Transformators Temperaturanstieg des Transformators Tap-Wechsler-Test SFRA – Sweep Frequency Response Analyzer Transformatorbuchsen-CT-Test . Häufig gestellte Fragen (FAQ) FAQ - TDK FAQ 01 Was ist Tan Delta Kit, Tan Delta Test | Verlustwinkeltest | Verlustfaktortest" Ein Isolator, wenn er über Leitung und Erde verbunden ist, verhält er sich wie ein Kondensator mit einem gewissen Widerstandseffekt aufgrund von Verunreinigungen. Tan Delta ist das Verhältnis von Widerstandsstrom (Ir) zu kapazitivem Strom (Ic) zu W.R.T 02 Ist KPM-TD12 schwierig zu bedienen?" _d04a07d8-9cd1-3239-9149 -20813d6c673b_KPM TD 12 ist ein leistungsstarkes Tan-Delta-Kit mit einfachster Bedienung. Bei weiteren Fragen wenden Sie sich bitte an unseren technischen Berater unter consulter@kpmtek.com 03 Welche Geräte können mit dem Tan Delta Test Kit - KPM TD12 getestet werden? KPM TD 12 ist in der Lage, Leistungstransformatoren (LV, HV & EHV), CT, PT, Grading-Kondensatoren usw. zu testen. KPM TD12 kann auch zum Testen von Öl-Tan-Delta- und Generator-Tan-Delta-Tests aufgerüstet werden. 04 Warum wir eine separate Anordnung/Zubehör benötigen, um Tan-Delta-Tests von Generatoren durchzuführen. Die Kapazität einiger Generatoren ist sehr hoch, daher ist ihr Leckstrom außerhalb der Reichweite der internen Stromquellen von Tan-Delta-Kits. Zur Durchführung von Tan-Delta-Tests von Generatoren haben verschiedene Hersteller unterschiedliche Methoden, wie z. B. Resonanzinduktivität oder externe Stromquellen usw. 05 Wie können wir Oil Tan Delta mit dem KPM TD 12 Tan Delta Test Kit testen? Wir können eine Öltestzelle an KPM TD 12 anschließen, die die Ölprobe erhitzt und den Tan-Delta-Test gemäß internationalen Standards durchführt. 06 Ist KPM TD12 ein sperriges Gerät mit enormen Abmessungen und Gewicht? KPM TD12 wiegt nur 28 kg bei kleinsten Abmessungen im Vergleich zu Mitbewerbern, z. 350 mm (L) × 270 mm (B) × 270 mm (H) Die Tragbarkeit macht es zu einem der am meisten bevorzugten Reisegeräte, das von Kunden mit viel Bewegung sehr bevorzugt wird. KPM TD 12, wenn es auf einem JUMBO TRUCK montiert ist, ist sehr leicht zu bewegen, selbst bei unebenen Bodenverhältnissen der Umspannstation mit allen Anordnungen von Werkzeugen, HV- und LV-Kabeltrommeln und Steckverbindern. 07 Ich habe Zweifel an Verbindungen zu KPM TD12, an wen kann ich mich wenden?" Verbindungen sind während des Tan-Delta-Tests sehr kritisch. Die Idee ist, den Weg des Leckstroms zu verstehen, der vom HV-Leiter zum LV-Leiter über die Isolierung fließt. Wenden Sie sich bei Unklarheiten jederzeit an unseren technischen Berater unter consulter@kpmtek.com 08 Wird das KPM-TD 12 Tan Delta Kit immer mit einem Jumbo Truck Trolley geliefert? Jumbo Truck ist optional, Benutzer können KPM TD 12 auch ohne Jumbo Truck kaufen. In diesem Fall erhält der Kunde ein KPM TD12-Gerät mit einer weichen Tragetasche mit allen Kabeln und Zubehör. 09 Was ist die Verwendung von Jumbo Truck Trolley? KPM TD 12, wenn es auf einem JUMBO TRUCK montiert ist, ist sehr leicht zu bewegen, selbst bei unebenen Bodenverhältnissen der Umspannstation mit allen Anordnungen von Werkzeugen, HV- und LV-Kabeltrommeln und Steckverbindern. Der Jumbo Truck kann auf 50 % seiner Größe zusammengeklappt werden, was ihn auch zu einem idealen Trolley für die Reise macht. Jumbo Truck kann für jedes KPM-Produkt angepasst werden. 10 So führen Sie die Kalibrierung des KPM TD 12 durch Die Kalibrierung des KPM TD12 kann mit dem Kalibrierungskondensatormodell KPM SC-100pF, einem 10-kV-, 100-pF-Standardkondensator, durchgeführt werden
- test | KPM India |test
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|test |https://kpmtek.wixsite.com/website/de/about-1 About Us Finding Inspiration in Every Turn This is your About Page. This space is a great opportunity to give a full background on who you are, what you do and what your website has to offer. Double click on the text box to start editing your content and make sure to add all the relevant details you want site visitors to know. Load More Our Story Every website has a story, and your visitors want to hear yours. This space is a great opportunity to give a full background on who you are, what your team does, and what your site has to offer. Double click on the text box to start editing your content and make sure to add all the relevant details you want site visitors to know. If you’re a business, talk about how you started and share your professional journey. Explain your core values, your commitment to customers, and how you stand out from the crowd. Add a photo, gallery, or video for even more engagement. Meet The Team Don Francis Founder & CEO Ashley Jones Tech Lead Tess Brown Office Manager Lisa Rose Product Manager Kevin Nye HR Lead Alex Young Customer Support Lead Our Clients EIN PUNKT-LÖSUNGSANBIETER FÜR ALLE ELEKTRISCHEN PRÜFANWENDUNGEN Cable LA Meter TRF Relay Machine Battery Testing GIS Circuit Breaker Tap Changer Monitor Testing EV Partial dischage CT/PT Earth testing
- Relay Test Kit | Relay Testing | KPM |Relay Testing
KPM automatic relay testing kits for highest specifications and strong support. With high power, current rating, accuracy and advance software. Capable of testing distance relays, differential relays, directional relays, power swing, synchronising function, df/dt etc of relays of ABB , siemens , alstom, sel, areva UNIVERSELLES RELAIS-TEST-KIT FAQ Video Theorie KF86 P , (6I , 6V & IEC 61850) 10Kg Tech-Blog KF 86P ist ein fortschrittliches, leistungsstarkes und hochpräzises automatisches Relais-Testkit, ideal für alle Arten von Relais-Testanwendungen. Hohe Nennleistung und hohe Stromstärke Ideales Relais-Testkit zum Testen von High Buden Elektromechanischen Relais Geringes Gewicht und hochmodernes Design (nur 10 kg) Hochmoderne Software (mit allen erweiterten Funktionen) zum Testen numerischer Relais Entspricht IEC61850-9-1, IEC61850-9-2, IEC60044-7/8 usw. (optional) Hardware-Merkmale des Universal-Relais-Testkits (KF86P): Sechs unabhängige Wechselspannungsquellen von jeweils 0–310 V bei 105 VA. Sechs unabhängige Stromquellen von 0 - 35 A bei je 425 VA. Eine unabhängige Hilfs-DC-Quelle von 14 ~ 300 V . Analogausgänge mit hoher Genauigkeit von <0,15 %rd + 0,05 %rg,Guar. Geeignet zum Prüfen von numerischen sowie elektromechanischen Relais Wandler- und Energiezählertest (optional im Relais-Testkit) KFA 300 , (3I & 3U), 3 kg Tech-Blog Einzigartiges Angebot: Leichtestes Relais-Testkit von < 3 kg mit analogem Ausgang Stromquellen: 3 x 10 A Spannungsquellen: 3 x 265 V Eingebautes Display und Akku Ideal zum Testen von numerischen und statischen Relais Softwarefunktion Manuelle/automatische AC-Testfunktion Zustandssequenzer-Testfunktion Überstrom-Breaker-Tester-Funktion Remote-Funktion (Signal, Messung, Steuerung). Fernsignaltestfunktion Relais-Testkit – K3063I (6I & 4U) Tech-Blog K3063i ist ein fortschrittliches und leistungsstarkes automatisches Relais-Testkit, das sich ideal zum Testen universeller Relaistests eignet Hohe Nennleistung und hohe Stromstärke Ideal zum Testen von High Buden Electro-mechanical Relays Geringes Gewicht und hochmodernes Design (nur 17 kg) State of Art Software (mit allen erweiterten Funktionen) zum Testen numerischer Relais Hardwaremerkmale von Universal Relay Test Kit (K3063i): Four unabhängige AC-Spannungsquellen von jeweils 0–310 V bei 124 VA. Sechs unabhängige Stromquellen of 0–35 A bei je 480 VA. Eine unabhängige Hilfsgleichstromquelle von 14~350 V bei 140 VA. Hochpräzise analoge Ausgänge von <0,15 % rd + 0,05 % rg, Guar. Geeignet zum Prüfen von numerischen sowie elektromechanischen Relais Prüfung des Energiezählers (optional) KFA 300 , (3I & 3U), 3 kg Tech-Blog Einzigartiges Angebot: Leichtestes Relais-Testkit von < 3 kg mit analogem Ausgang Stromquellen: 3 x 10 A Spannungsquellen: 3 x 265 V Eingebautes Display und Akku Ideal zum Testen von numerischen und statischen Relais Softwarefunktion Manuelle/automatische AC-Testfunktion Zustandssequenzer-Testfunktion Überstrom-Breaker-Tester-Funktion Remote-Funktion (Signal, Messung, Steuerung). Fernsignaltestfunktion Relais-Testkit - K3163i (6I & 4U & IEC 61850) Tech-Blog K3163i+ ist ein fortschrittliches, leistungsstarkes und hochpräzises automatisches Relais-Testkit, ideal für alle Arten von Relaistests applications. bad5cf58d_ Hohe Nennleistung und hohe Stromstärke Ideales Relais-Testkit zum Testen von High Buden Electro-mechanical Relays Geringes Gewicht und hochmodernes Design (nur 17 kg) State of Art Software (mit allen erweiterten Funktionen) zum Testen numerischer Relais Entspricht IEC61850-9-1, IEC61850-9-2, IEC60044-7/8 usw. (optional) Hardware-Eigenschaften von Universal Relay Test Kit (K3163i): Four unabhängige AC-Spannungsquellen von jeweils 0–310 V bei 124 VA. Sechs unabhängige Stromquellen von 0 - 35 A bei je 480 VA. Eine unabhängige Hilfsgleichstromquelle von 14~350 V bei 140 VA. Hochpräzise analoge Ausgänge von <0,15 % rd + 0,05 % rg, Guar. Geeignet zum Prüfen von numerischen sowie elektromechanischen Relais Wandler- und Energiezählertest (optionales in relay Testkit) Relais-Testkit - K68I (3I & 4U) Tech-Blog K68i ist ein leistungsstarkes und robustes Relais-Testkit zum halbautomatischen und manuellen Testen von Relais . Hardware Features of Relay Test Kit K68i: Relaistester im All-in-One-Design mit 6,4-Zoll-LCD-Display. Four unabhängige AC-Spannungsquellen von 0–300 V bei jeweils 110 VA. Drei unabhängige Stromquellen mit jeweils 0–35 A bei 450 VA. Eine unabhängige Hilfs-DC-Quelle von 0 ~ 300 V/0,6 A. Hochpräzise analoge Ausgänge von <0,15 % rd + 0,05 % rg, Guar. Projektorkompatibler Anschluss für Schulungs- und Studienzwecke. Robustes Design mit extrem langlebigem Drehgeber + Funktionstastatur. Softwarefunktionen von Universal Relay Test Kit K68i: Kann die meisten Relais im manuellen oder halbautomatischen Modus testen - Spannungsrelais, Stromrelais, Frequenzrelais, Leistungsrelais, Impedanzrelais, Oberschwingungsrelais, Distanzrelais usw. Mit Eigengehäuse & Erdungserkennungsfunktion Video Relay Test Kit Videos - Relais-Testkits Relay Test Kit Videos Relay Test Kit Videos Video abspielen Teilen Ganzer Kanal Dieses Video Facebook Twitter Pinterest Tumblr Link kopieren Link kopiert Search videos Video suchen... Wird abgespielt UNBOXING RELAY TEST KIT - KINGSINE K3063I 05:50 Video abspielen Wird abgespielt K68i , Fanox Sia B relay testing demonstration. 00:45 Video abspielen Wird abgespielt Unboxing Relay test kit 06:56 Video abspielen Theorie - Relaisprüfung Theory -Relay Test Kit Relais-Testkit – Theorie Das Schutzrelais ist ein Gerät, das die Ausrüstung des Stromversorgungssystems wartet und unter anormalen Bedingungen einen Ausgang liefert, um den Schutz des Systems zu gewährleisten. Das grundlegende Ziel des Schutzrelais besteht darin, den fehlerhaften Abschnitt in einem Stromversorgungssystem so schnell wie möglich zu isolieren, damit der Rest des Systems normal funktioniert. Es ist notwendig, Sicherheit, Zuverlässigkeit, Qualität, Empfindlichkeit und Geschwindigkeit von Relais zu ermitteln. In nationalen und internationalen Normen werden verschiedene Tests empfohlen, um die Widerstandsfähigkeit eines Relais unter Fehlerbedingungen zu überprüfen. Während des Tests wird das Schutzrelais simulierten Feldbedingungen unterzogen, um seine Leistung zu überprüfen. Die relevanten nationalen/internationalen Normen empfehlen viele Tests, um die Wirksamkeit des Relais zur Erfüllung seiner beabsichtigten Funktion zu ermitteln. Ein Relais empfängt die Eingangssignale von CTs/PTs und sein Programm berechnet die Fehlerbedingungen je nach Anwendung. Er gibt einen Auslösebefehl an den Leistungsschalter aus, wenn er einen fehlerhaften Zustand erkennt. Auf der Grundlage der Anwendung kann Relais in die folgenden Typen eingeteilt werden: Schritt 1: Relay Testing Kit injiziert einen Fehler in Form von I & V an den jeweiligen CT- und PT-Punkten von Relay under test . Der Timer des Relay Testing Kit beginnt mit der Initiierung von fault injection. Schritt 2: Das Relais erkennt den Fehler und gibt den Auslösebefehl aus, sein Auslösezeitpunkt muss von den Zeiteigenschaften der Relaiseinstellungen abhängen. Schritt 3: Das Relais-Testkit empfängt den Auslösebefehl vom Relais und stoppt den Timer. Schritt 4: Die gemessenen Auslösekennlinien werden in Bezug auf die erwartete Auslösung gemäß den Einstellungen des Ingenieurs verglichen. Der grundlegende Anschluss des Schutzrelais wurde im Bild gezeigt. Die Sekundärseite des Stromwandlers ist mit der Stromspule des Relais verbunden. Die Sekundärseite des Spannungswandlers ist mit der Spannungsspule des Relais verbunden. Immer wenn ein Fehler im Zuleitungskreis auftritt, fließt ein proportionaler Sekundärstrom des Stromwandlers durch die Stromspule des Relais, wodurch sich der MMF dieser Spule erhöht. Dieser erhöhte mmf reicht aus, um den normalerweise offenen Kontakt des Relais mechanisch zu schließen. Dieser Relaiskontakt schließt tatsächlich und vervollständigt den Gleichstrom-Auslösespulenkreis, und daher wird die Auslösespule erregt. Die mmf der Auslösespule leitet die mechanische Bewegung des Auslösemechanismus des Leistungsschalters ein und schließlich wird der Leistungsschalter ausgelöst, um den Fehler zu isolieren. Relaistypen nach verschiedenen Anforderungen: Differential Relay Überstrom Relay Frequenzbetätigt Relay Gerichteter Überstrom Relay Eingeschränkter Erdschluss Relay Über Fluxing Relay Entfernungsschemata Relay Stromschienenschutz Relay Rückwärtsleistung Relay Erregungsverlust Relay Negative Ph. Sequence Relay Energiezähler Relay Transducers Relay Fehler Playback Relay Häufig gestellte Fragen FAQ-RTK FAQ about all our Relay testing products 01 Was ist ein Relais-Testkit? Ein Relaistestkit ist eine Ausrüstung, die zum Testen verschiedener Arten von Relais verwendet wird. Das Relais-Testkit ist eine Kombination aus programmierbaren Strom- und Spannungsquellen und einem Timer. Während des Relaistests fügt das Relaistestkit einen Fehler in das Relais ein (in Form von CT & PT) und misst die Auslösezeit oder Reaktionszeit des Relais. Wenn das Verhalten des Relais seinen Einstellungen entspricht, hat das Relais den Test bestanden, andernfalls besteht das Relais den Test nicht . 02 Warum werden automatische Relais-Testkits gegenüber herkömmlichen (variac-basierten) Relais-Testkits bevorzugt? Automatische Relais-Testkits haben verschiedene Vorteile gegenüber herkömmlichen Kindertests 1. Signalstabilität: Der Ausgang des Strom- und Spannungsausgangs des automatischen Relais-Testkits ist nicht proportional zu seiner Eingangsstromversorgung. Dies bedeutet, dass der Strom- und Spannungsausgang des Relais-Testkits von analog zu digital und dann von digital zu analog mit einer Wandlung versorgt wird Rückkopplungsschleife, daher sind die Ausgangssignale des Relaistestkits nicht von seiner Eingangsstromversorgung abhängig. Die Ausgabe des automatischen Relais-Testkits ist stabil, auch wenn die Eingangsstromversorgung geringfügig instabil ist 2. Genauigkeit, Auflösung und Funktionalität: Mit automatischen Relais-Testkits kann der Benutzer Phasenfrequenz und Größe aller Strom- und Spannungssignale unabhängig voneinander mit sehr hoher Auflösung und Genauigkeit variieren. Dies ist bei herkömmlichen sekundären Injektionskits nicht möglich, die nur die Größe (V oder I) mit Hilfe eines manuellen Variac erhöhen oder variieren können. 03 Was ist ein numerisches Relais-Testkit? Numerisches Relaistestkit ist ein anderer Name für automatische oder mikroprozessorbasierte Relaistestkits. Numerische Relais haben im Allgemeinen eine hohe Genauigkeit, die mit hochgenauen automatischen Relais-Testkits getestet werden kann 04 Was ist ein universelles Relais-Testkit? Universal Relay Test Kit ist ein anderer Name für automatische Relais-Testkits, da der Benutzer Phase, Frequenz und Größe der Strom- und Spannungsquellen unabhängig variieren und jede Art von Fehler erzeugen kann. 05 Was ist ein 6-Phasen-Relais-Testkit, wenn im Stromsystem nur 3-Phasen-CT oder -PT vorhanden sind?" Viele Kunden sind mit der Notation des 6-Phasen-Relais-Testkits verwirrt. Die High-End-Relais-Testkits verfügen über sechs Stromquellen, deren Phasenfrequenz und -größe unabhängig variiert werden können. Diese 6 Stromquellen sind sehr nützlich beim Testen eines Differentialrelais. 06 Wozu ist eine Vorabsoftware mit automatischen Relais-Testkits erforderlich? Da wir wissen, dass jeder Fehler aufgrund von Schwankungen der Phase, Frequenz oder Größe im CT- oder PT-Signal erzeugt wird, sind wenige Fehlersimulationen nicht sehr einfach (wie das Testen von viereckigen Eigenschaften von Distanzrelais). Fortschrittliche Software ist sehr nützlich bei der Simulation komplexer Fehler. Kingsine-Benutzer erhalten All-in-One-Voraussoftware bei ihrem Standardkauf . 07 Warum Hochstrom- und Spannungsverstärker in Relaistestkits wünschenswert sind Es wird wirklich gesagt, dass Strom- und Spannungsquellen die Seele des Relais-Testkits sind. Hohe Strom- und Spannungssignale sind auf folgende Weise nützlich Zum 10-maligen Testen von 5-A-Überstromrelais müssen wir 3 x 50 A einspeisen, was mit Hochstrom-Relais-Testkits möglich ist Mit höherem Strom können wir ein Differentialrelais an einem höheren Punkt der BIAS-Kurve testen. Mit höheren Strömen können wir höhere Fehler in der Wiedergabe transienter Fehler simulieren. Kingsine-Testkits haben die höchsten Nennstromquellen von jeweils 0 bis 35 A (@450 VA) und jeweils 0 bis 300 V (124 VA) 08 Warum sind Hochleistungsverstärker in Relais-Testkits wünschenswert? Relais-Testkits mit Hochleistungsverstärkern werden bevorzugt, da zum Testen der elektromechanischen Relais eine hohe Leistung erforderlich ist. Auch wenn ein Relais-Testkit eine höhere Nennleistung hat, ist seine Einschaltdauer für eine niedrigere Nennleistung hoch und somit ein robusteres Design. Kingsine verfügt über die stärksten Stromquellen mit jeweils 480 VA ( @ 35 A ) und die stärksten Spannungsquellen mit jeweils 124 VA ( @ 310 V ) 09 Was ist wichtiger, Advance-Software oder leistungsstarke Hardware bei der Auswahl eines automatischen Relais-Testkits?" Eine leistungsstarke Hardware ist für die Langzeitrobustheit eines Relais-Testkits am wichtigsten. Wenige Anwendungen benötigen auch leistungsstarke Quellen. Eine fortschrittliche Software ist ein Werkzeug, das dem Benutzer hilft, selbst die komplexesten Relais auf einfachste Weise zu testen. Daher soll das Relais-Testkit im heutigen Szenario eine Kombination aus hoch bewerteten Quellen und fortschrittlicher Software sein. K3063i ist eine gute Kombination für beides 10 Warum haben Relais-Testkits von Kingsine die höchste Nennleistung auf dem Markt? Bei Kingsine beträgt jede Stromquelle 480 VA bei 35 A und die Spannungsquelle 124 VA bei 310 V, also die höchste auf dem Markt. 11 Warum ist Kingsine K3063i die beste Kombination aus Leistung und Genauigkeit? K3063i verfügt über eine leistungsstarke Spannungs- und Stromquelle (die Stromquelle beträgt 480 VA bei 35 A und die Spannungsquelle beträgt 124 VA bei 310 V), während es einen Strombereich von 3 A hat, was zu einer sehr hohen Genauigkeit bei niedrigeren Strömen führt. p> 12 An wen wenden Sie sich für Support für Testgeräte von KPM? Bei Fragen wenden Sie sich bitte an unseren technischen Berater unter Consultant@kpmtek.com . 13 Wo befindet sich das Servicezentrum für Relais-Testkits von Kingsine in Indien? Wir haben ein Vorab-Servicezentrum in Gurgaon, Haryana, mit 100 % Ersatzteilverfügbarkeit . 14 Was ist df/dt-Relay, kann ich es mit Kingsine Relay Test Kits testen? Das Frequenzänderungs-Relais (ROCOF oder df/dt) wird für einen schnellen Lastabwurf verwendet, um die Betriebszeit in Über- und Unterfrequenzsituationen zu beschleunigen und einen Netzausfall zu erkennen. ROCOF- oder df/dt-Relais sind besonders effektiv beim Aufhalten des Frequenzeinbruchs eines Netzes im Falle eines plötzlichen Ausfalls einer großen Stromerzeugung. Dies liegt daran, dass durch Messen der Frequenzabfallrate die Korrekturmaßnahme viel vor dem Zeitpunkt eingeleitet werden kann, zu dem die Frequenz der synchronen Verbindung tatsächlich auf einen Punkt gesunken wäre, an dem Unterfrequenzrelais des Generators oder Hilfsgeräte der Einheit auslösen / arbeiten würden, was dazu führen würde ein komplettes Herunterfahren des Systems. Der df/dt wird zum Lastabwurf in Situationen verwendet, in denen ein plötzlicher Verlust der Erzeugungskapazität eines Systems mit einer Abnahme der Systemfrequenz einhergeht. In einer solchen Situation einer Lasterzeugungsfehlanpassung neigt die Systemfrequenz dazu, zu fallen. Das df/dt-Relais kann die Leistungsschalter steuern und ermöglichen, dass die Abzweige einzeln vom Netz getrennt werden. In Kingsine Software gibt es ein spezielles Modul zum Testen von df/dt 15 Was ist ein Distanzrelais, welche Relaistestkits können diese Relais testen?" Ein Distanzrelais / Impedanzrelais ist ein spannungsberuhigtes Überstromrelais. Das Relais misst die Impedanz bis zum Fehlerpunkt und gibt einen Auslösebefehl, wenn diese Impedanz kleiner als die Relaiseinstellung Z ist. Die Relaiseinstellung Z ist als Nachbildungsimpedanz bekannt und proportional zur eingestellten Impedanz, d. h. der Impedanz bis zur Reichweite des Relais . Das Relais überwacht kontinuierlich den Leitungsstrom I durch CT und die Busspannung V durch PT und spricht an, wenn das V/I-Verhältnis unter den eingestellten Wert fällt. In Kingsine haben sowohl K68i als auch K3063i spezialisierte Module zum Testen von Distanzrelais. 16 Warum ein Hochleistungs-Relais-Testkit zum Testen eines elektromechanischen Relais erforderlich ist Elektromechanische Relais haben Spulen mit hoher Impedanz, während des Testens des Relais-Testkits muss Strom über Spulen mit hoher Impedanz eingespeist werden, daher ist eine hohe Belastung erforderlich. Kingsine-Kits haben die höchste Belastung und sind daher ideal zum Testen aller Arten von Relais. 17 Was ist die erweiterte Transienten-Wiedergabefunktion des automatischen Relais-Testkits? Heutzutage sind alle Vorausrelais mit einer Fehlerschreiberfunktion ausgestattet. Immer wenn ein Fehler auftritt, wird diese Fehlerdatei im Relay in Form einer .cfg/comtrade-Datei gespeichert. Das Relais-Testkit hat die Funktion, diese Datei in seine Software zu importieren und die Datei unter Verwendung seiner Strom- und Spannungsquellen wiederzugeben. Dies wird als Transient-Wiedergabefunktion bezeichnet. 18 Welche Vorsichtsmaßnahmen sind beim Betrieb des Relais-Testkits bei den Anschlüssen zu beachten? Einige der Website-Vorsichtsmaßnahmen sind -: Alle CT- und PT-Klemmen, die an das Relais-Testkit angeschlossen werden sollen, dürfen nicht unter Spannung stehen. Die Erdung muss immer mit dem Bausatz verbunden sein. Während des Testens sollten Hochstromstoßgeräte wie Schweißgeräte im selben Stromversorgungskreis des Relaistestkits vermieden werden. Arbeiten Sie immer gemäß den relevanten lokalen oder internationalen Teststandards . 19 Welche Art von Schutzfunktionen gibt es in Kingsine Automatic Relay Test Kits? Kingsine Relay Test Kits haben die folgenden Schutzmaßnahmen Kurzschlussschutz mit Spannungsverstärkern Unterbrechungsschutz für Stromverstärker Überhitzungsschutz . Gesundheitserdanzeige usw. 20 Ich möchte Differentialrelais testen. Welche Art von Relais-Testkit ist für mich besser geeignet? Zum Testen eines Differentialrelais auf 3-Phasen-Basis benötigen wir ein 6-Stromquellen-Relais-Testkit, d
- KPM EU Operations | KPM India |KPM EU Operations
Benefiting world with INDO-EU partnerships, We are working in 1) Electrical t & m equipment 2) OEM services for Made In India electrical equipment 3) Sales & Purchase of Used / New M/Cs ( EU Origin ) all across the world . for detail visit us on http://www.kpmtek.eu MADE IN INDIA - OEM SERVICES CT , PT , Metering Cubicle , Isolators etc. TECH TIEUPS - POWER SECTOR Electrical Testing & Monitoring Solutions NEW / USED MACHINES - EU Printing M/C, Paper Converting M/C. etc. BENEFITING WORLD WITH INDO-EU OEM-SERVICES FÜR MESSTRANSFORMATOREN ( BIS ZU 33KV ) Wir bieten OEM-Services für Kunden aus der EU-Region for Messwandler (Öl- und Harzguss, bis zu 33 kV), Isolatoren, Messschränke und Zubehör für Übertragungsleitungen. Alle unsere Produkte werden in hochmodernen Anlagen in INDIEN hergestellt, wobei die Qualität auf höchstem Niveau gehalten wird . Jedes vom KPM-Team versandte Gerät wird gemäß den IEC-Werkstestanforderungen getestet . Messwandler & Zubehör Mfg. - WELLMAN INDIEN +48 539438443 sales@kpmtek.eu CT PT OEM GEBRAUCHTE MASCHINEN AUS EU-REGION Sind Sie ein Unternehmen, das bereit ist, gebrauchte, zuverlässige europäische Technologiemaschinen aus der EU-Region zu kaufen? Aus diesem Grund sind wir die erste Wahl für Kunden wie Sie ! Wir sind ein indisches Unternehmen, das sich mit der Lieferung hochwertiger alter Maschinen aus der EU-Region bis der Region des indischen Subkontinents befasst. Unsere Industrieabteilung Deals in einer umfangreichen Reihe von Flexo- und Offsetdruckmaschinen Papierverarbeitungsmaschinen, Vorrichtungen und Vorrichtungen Spezialmaschinen. Unsere technischen Berater sind ständig in der EU-Region stationiert und bieten Qualitätsprüfungsdienste von Grund auf für gebrauchte Maschinen. Unsere Experten überwachen den Demontageprozess bis zur Ladephase . In Indien haben wir ein erfahrenes Team für die effiziente Inbetriebnahme & Fehlerbehebung der gelieferten Maschinen. Jede von uns gelieferte Maschine wird durch eine 1-Jahres-Garantie in der INDISCHEN SUBKONTINENT-REGION unterstützt Kontaktieren Sie uns noch heute und besprechen Sie die Maschinen, die Sie suchen ! SUPPORTPARTNER FÜR INDIEN – WEBTECH, ein hochwertiger Hersteller von Druck, Papierverarbeitung und SPM . +48 539438443 sales@kpmtek.eu Anfrageformular Lösungen für den Energiesektor Technologie- und Unternehmensbindungen KPM verfügt über umfassende Vertriebs- und Anwendungserfahrung sowohl im Bereich elektrischer Prüf- und Messgeräte für Hochspannung als auch für Niederspannung. Jede von KPM Engineering gelieferte Ausrüstung hat sich unter Feldbedingungen bewährt. Unsere Prüfgeräte für Umspannwerke werden unter lauten Bedingungen von LIVE EHV-UHV-Schaltanlagen (bis zu 765 kV) getestet Wir sind aktiv offen für Diskussionen und suchen nach Corporate & Technical Verbindungen unter den Zeilen -: Ein Forschungs- und Designunternehmen mit einer Lösung für den Energiesektor, das nach technischen Verbindungen sucht . Ein Benutzer/Distributor, der bereit ist, die bestehenden Test- und Überwachungslösungen von KPM in der EU-Region . zu verkaufen/kaufen Investoren und Mitarbeiter +48 539438443 sales@kpmtek.eu USED MACHINES POWER SECTOR TIEUPS
- Battery Testing ( Utility ) | KPM Engineering Sol.|Battery Testing ( Utility )
Battery testing & monitoring Equip. for Utility Battery Banks .Our Solutions consist of Battery internal resistance analyzer, Battery Monitoring System, Battery Data Logger, Battery Discharge Load Banks with data acquisition. BATTERIETEST ( Dienstprogramm ) Batteriewiderstands- und Leitfähigkeitstester Katalog KPM BA-02 Batterieanalysator Der BA-02 Battery Anlayzer ist ein fortschrittlicher Tester, der ein sehr effektives und wirtschaftliches Batteriemanagementgerät zum Testen des Batterieinnenwiderstands, der Leitfähigkeit und der Spannung ist. Es hilft Ihnen, schwache Batterien zu eliminieren, um die Leistung Ihrer Batteriesysteme sicherzustellen. Es ist in der Lage, den Innenwiderstand (oder die Leitfähigkeit) von Batterien genau und konsistent zu messen, ventilgeregelte Bleisäure (VRLA), belüftete Bleisäure (VLA) und Ni-Cd-Batterien, die die Hauptbestandteile von kritischen Standby-Stromversorgungssystemen sind. Dieser Batterietester wird häufig von Dienstleistern, Betriebs- und Wartungsteams für Batteriemanagement und -messung eingesetzt, um die Leistungsintegrität in verschiedenen Branchen sicherzustellen Akku-Datenlogger Katalog KPM BDL ( Batteriedatenlogger ) Die KPM BDL-Serie ist ein aktualisierter Batteriedatenlogger, um die IEEE-Messstandards für Batteriespannung, Strangspannung, Strom und Umgebungstemperatur zu erfüllen. Es ist von 12 V bis 700 V für verschiedene Batteriesysteme angepasst. Und es lässt sich einfach für alle Batteriesysteme erweitern. Mit der WLAN-Kommunikation können Sie problemlos vollständige Daten anzeigen und Testberichte in der PC-Software erstellen. Für einen Schnelltest des Batterieinnenwiderstands/-leitwerts siehe auch KPM BA 01 Batteriezustandsanalysator . Batterieladebank Katalog KPM- Batterieladebank Wir bieten eine Reihe von kundenspezifischen Batterielastbänken mit vielen verschiedenen Modellen für Konstantstrom-Entladetests und Batteriekapazitätstests. Sie decken einen weiten Spannungsbereich von 12V bis 480V Nennspannungen bei Strömen bis 600A ab. Sie sind in verschiedenen Branchen weit verbreitet. Mit dem optionalen Batterie-Datenerfassungskoffer (DAC) können die Entladewerte JEDER Zelle gleichzeitig in der Batterieladebank und der PC-Software überwacht werden, indem die Datenansichtssoftware von Kongter verwendet wird. Derselbe DAC in Batterieladebank kann auch unabhängig mit „String DAC“ arbeiten, um ein anderes Produkt herzustellen, Batteriedatenlogger . Für einen Schnelltest des Batteriezustands siehe bitte BA-01 Batteriezustandsanalysator das den Innenwiderstand/Leitfähigkeit der Batterie in Sekunden testet. Häufig gestellte Fragen FAQ about all our battery utility : 01 What is the purpose of battery utility testing in backup power systems? Battery utility testing ensures the reliability, health, and performance of backup power systems used in utilities, substations, data centers, and critical infrastructure. Over time, batteries degrade due to factors like temperature, charge-discharge cycles, and age. Testing helps detect early signs of failure such as increased internal resistance, reduced capacity, or imbalance among cells. This enables timely maintenance or replacement, preventing unexpected power loss during outages. Utility testing validates whether batteries meet required discharge durations and ensures compliance with standards like IEEE 450 or IEC 60896. Regular testing minimizes downtime, enhances operational safety, and protects expensive downstream equipment. KPM provides advanced battery analyzers and constant current discharge kits designed for utility-scale battery banks. These instruments measure internal resistance, voltage, and capacity under load conditions. KPM’s systems are aligned with international testing standards and are used by utilities to perform periodic health checks, identify weak cells, and ensure uninterrupted power backup readiness. 02 What safety precautions must be taken during battery testing? Battery testing involves handling high voltages, currents, and hazardous chemicals, so strict safety precautions are essential. Always wear appropriate personal protective equipment (PPE) such as insulated gloves, eye protection, and flame-resistant clothing. Ensure proper ventilation, especially for lead-acid batteries that emit hydrogen gas during charging or discharging. Isolate the battery bank from the load before testing, and use insulated tools to prevent short circuits. Verify polarity before connecting test equipment to avoid damage or sparking. Never allow metal objects near open battery terminals. Maintain safe distances and use warning signs during high-current discharge tests. Monitor temperature rise and terminate testing if overheating or voltage instability is observed. Follow the manufacturer’s guidelines and applicable standards (IEEE, IEC) during every procedure. KPM’s battery analyzers and discharge testers are equipped with multiple safety features such as overcurrent protection, reverse polarity alarms, thermal cutoffs, and auto-shutdown. KPM also provides user training and safety documentation to ensure proper and secure operation. 03 How does internal resistance measurement indicate battery health? Internal resistance (IR) is the opposition a battery offers to current flow within its own structure. As batteries age or degrade, their internal resistance increases due to chemical wear, sulfation (in lead-acid), or electrode deterioration. Here's how it reflects battery health: Low IR = Healthy battery: Indicates good electrolyte condition, intact electrodes, and low energy loss during discharge. High IR = Degraded battery: Results in voltage drops under load, reduced capacity, and heat generation during operation. Rising IR over time signals aging or developing faults, even if voltage appears normal. Sudden spikes in IR may indicate failing cells or poor interconnections. Thus, internal resistance is a quick, non-invasive diagnostic metric used to identify weak or failing batteries before they cause critical power failures. KPM’s battery analyzers measure IR accurately across large battery banks, providing real-time indicators of cell health and enabling predictive maintenance. 04 What are the key parameters measured by a battery analyzer? A battery analyzer is used to assess the condition and performance of individual cells and complete battery banks. The key parameters it typically measures include: Internal Resistance (IR):Indicates the battery’s ability to deliver current. Higher resistance means deterioration or aging. Voltage (V): Measures the open-circuit voltage of each cell or unit to check state-of-charge and overall health. Conductance (optional): Used as an alternative to resistance in some analyzers to determine battery condition. Temperature (°C): Affects performance and safety. Monitoring ensures accurate readings and helps prevent overheating. State of Health (SoH): Some analyzers estimate the health of the battery based on historical and real-time data. Cell Imbalance: Detects inconsistencies among cells in a battery bank, which can lead to system failure. Ripple Voltage (if applicable): Monitors AC noise on DC lines, often in UPS and telecom systems. KPM’s battery analyzers measure all key parameters—internal resistance, voltage, temperature, and cell imbalance—with high accuracy. Features include: High-precision sensors and rugged design for utility environments, Built-in safety features (reverse polarity, overvoltage alerts), PC software for data logging, trending, and report generation. Widely used in substations, power plants, and telecom towers for preventive maintenance and health diagnostics. 05 Can battery conductivity testing detect early-stage cell degradation ? Conductivity is a measure of a battery’s ability to pass electrical current. In healthy batteries, conductivity is high because the internal chemical pathways are clean and efficient. As a cell begins to degrade (due to sulfation, corrosion, electrolyte breakdown, or plate shedding), these pathways become obstructed, causing conductivity to decrease—even before voltage or capacity noticeably drops. Early Detection: Changes in conductivity often occur before performance failures, allowing for early intervention. Identifies Weak Cells: It helps isolate underperforming cells within a battery bank. Prevents Failures: Enables predictive maintenance and avoids costly downtime. Monitors Aging: Tracks gradual degradation over time for lifecycle management. KPM’s advanced battery analyzers can perform conductivity or internal resistance-based diagnostics, depending on battery type. These tools help utility and industrial users identify subtle degradation trends early, plan timely maintenance, and ensure long-term battery reliability. 06 Why is constant current discharge testing crucial in critical power applications? Constant current discharge testing is essential because it directly evaluates a battery’s actual capacity and performance under load, simulating real-world power demands. In critical power applications—such as substations, hospitals, data centers, and telecom systems—batteries must supply reliable power during outages or switching events. If a battery cannot sustain the required current for the expected duration, it risks system failure, data loss, or equipment damage. Key reasons it’s crucial: Confirms True Capacity: Validates if the battery can deliver its rated ampere-hours (Ah) under specified load. Identifies Weak Batteries: Detects hidden degradation not revealed by voltage or internal resistance alone. Reveals Runtime Performance: Simulates backup duration under real conditions. Supports Preventive Maintenance: Enables data-driven decisions for battery replacement and servicing. KPM’s constant current discharge kits are designed for high-reliability environments. They offer programmable loads, auto cut-off, data logging, and safety features, ensuring accurate, safe, and standards-compliant capacity testing for critical backup systems. 07 How is the battery's capacity (Ah) validated through a discharge test? Battery capacity, measured in ampere-hours (Ah), is validated by discharging the battery at a constant current until it reaches its specified cut-off voltage. The total time it takes to reach that voltage determines the actual capacity using the formula: Capacity (Ah)=Discharge Current (A) × Discharge Time (hours) Example: If a battery is discharged at 10 A and it takes 5 hours to reach the end voltage, the delivered capacity is: 10 A × 5 hrs = 50 Ah This result is then compared to the battery’s rated capacity (e.g., 100 Ah). If it delivers significantly less, it indicates degradation or failure. KPM’s constant current discharge kits precisely control and monitor the discharge current and voltage. They record time-stamped data, auto-calculate Ah, and generate test reports. These tools comply with standards like IEEE 450, ensuring reliable capacity validation for utility and industrial batteries. 08 What role does ambient temperature play in discharge test accuracy? Ambient temperature has a significant impact on the accuracy and outcome of battery discharge tests. Battery performance is highly temperature-sensitive, particularly for lead-acid, lithium-ion, and Ni-Cd chemistries. At High Temperatures: Battery capacity appears higher because chemical reactions speed up. Can lead to overestimation of real-world performance. Increases the risk of thermal runaway or cell damage. At Low Temperatures: Capacity drops due to slower electrochemical activity. May result in underestimated performance and early cut-off in tests. Internal resistance rises, leading to voltage drops under load. Deviations from this temperature should be noted and corrected using manufacturer-specified compensation factors or software. KPM’s battery discharge testers and analyzers include temperature monitoring sensors. The system records ambient and cell temperatures during testing and can apply correction factors to ensure accurate capacity evaluation under varying environmental conditions. 09 How do we determine end-voltage for discharge cut-off? The end-voltage, or cut-off voltage, is the minimum voltage at which a battery should be discharged to avoid deep discharge damage and to ensure reliable capacity measurement. It is determined based on the battery type, rated capacity, discharge rate (C-rate), and manufacturer specifications. For example, a 12V lead-acid battery typically has an end-voltage of 10.5V (1.75V per cell) at standard rates. Discharging below this threshold can lead to irreversible sulfation, reduced life, or failure. In lithium-ion batteries, cut-off is often set higher (e.g., 2.5V–3.0V per cell) to protect cell chemistry and safety. The correct end-voltage ensures consistent and safe testing across different test cycles. It must also be adjusted for ambient temperature and load current, as higher loads can cause greater voltage sag. KPM’s discharge kits allow users to program end-voltage settings per battery specs. The system automatically halts testing at the preset voltage to prevent over-discharge and protect battery health. 10 How can test data be used to predict battery end-of-life? Battery test data—such as internal resistance, voltage, capacity, and temperature trends—can be analyzed over time to accurately predict end-of-life (EOL). A consistent increase in internal resistance and decline in capacity (Ah) are key indicators of aging. When a battery can no longer deliver at least 80% of its rated capacity, it is generally considered at the end of its useful life. Regular discharge tests and impedance measurements create a performance history that reveals degradation rates, enabling predictive analytics. By identifying abnormal changes, such as faster resistance rise in one cell compared to others, maintenance teams can isolate failing units early. Trend-based monitoring allows scheduling replacements before failures occur, ensuring reliability in critical applications. KPM’s analyzers and discharge kits offer data logging, graphing, and reporting features that help utilities and industries track battery health over time, enabling data-driven EOL prediction and proactive asset management.
- Monitoring Solutions | KPM Engineering Sol.|Monitoring Tester
Our monitoring solutions consist of Online power cable temperature monitoring using optical sensors, Online cable partial discharge monitoring, Online Earth Resistance Monitoring etc. ONLINE-TE- UND ERDUNGSÜBERWACHUNG Penta PD - Teilentladungsdetektor Mehr wissen Penta PD Teilentladungsdetektor Teilentladungsdetektor Penta-PD ist ein idealer Partner für zustandsbasierte Wartungsprogramme. Teilentladungsdetektor Penta-PD enthält alle 5 Arten von Online-PD-Sensortechnologie. Informationen von mehreren Sensoren verleihen dem Teilentladungsdetektor Penta-PD die Vielseitigkeit, verschiedene Arten von TE in einer Vielzahl von Umspannwerksgeräten zu erkennen. Erkennungsbandbreite 1.TEV - Transiente Erdspannung, Bereich 3 ~ 100 MHz 2.UHF – Ultrahochfrequenz 300MHz~2000 MHz 3.UA – Ultraschall 40 ~ 200 KHz Messbereich 1.UA: -90~80dB 2. TEV: -80 ~ 10 dBm 3. UHF: -80 ~ 10 dBm. Sensor: a) Ultraschallsensor: 20~200 (kHz); b) EV-Sensor (Transient Earth Voltage): 5 ~ 100 MHz; c) UHF-Sensor: 300 ~ 2000 (MHz), mit gerichteter Empfangscharakteristik. Penta PD - Teilentladungsdetektor Mehr wissen Penta PD Teilentladungsdetektor Teilentladungsdetektor Penta-PD ist ein idealer Partner für zustandsbasierte Wartungsprogramme. Teilentladungsdetektor Penta-PD enthält alle 5 Arten von Online-PD-Sensortechnologie. Informationen von mehreren Sensoren verleihen dem Teilentladungsdetektor Penta-PD die Vielseitigkeit, verschiedene Arten von TE in einer Vielzahl von Umspannwerksgeräten zu erkennen. Erkennungsbandbreite 1.TEV - Transiente Erdspannung, Bereich 3 ~ 100 MHz 2.UHF – Ultrahochfrequenz 300MHz~2000 MHz 3.UA – Ultraschall 40 ~ 200 KHz Messbereich 1.UA: -90~80dB 2. TEV: -80 ~ 10 dBm 3. UHF: -80 ~ 10 dBm. Sensor: a) Ultraschallsensor: 20~200 (kHz); b) EV-Sensor (Transient Earth Voltage): 5 ~ 100 MHz; c) UHF-Sensor: 300 ~ 2000 (MHz), mit gerichteter Empfangscharakteristik. PQ-Analysator Light Mehr wissen Modell KPM PQ Light 1) Produktkomponententyp Mehrphasiger Hand-Leistungsmesser 2) Phasenbezeichnung 3PH4W (ohne In) 3PH3W 1PH2W (LN); 1PH2W(LL);1PH3W(LLN) 3. Geräteanwendung • Leistungsanalyse • Energiezähler 4. Eingangstyp • Externe Rogowski-Spule • Externer Stromwandler (nur 333 mV) 5. Anzeige 3,5-Zoll-TFT-Bildschirmanzeige 6. Abtastrate 8.000 Abtastungen pro Sekunde 7. Harmonische 52. Max 8. Mechanische Eigenschaften • Gewicht 350 g • Maße L x B x T: 21,5 x 10 x 3,5 cm PQ-Analysator + Mehr wissen Modell KPM PQ Light 1) Produktkomponententyp Mehrphasiger Hand-Leistungsmesser 2) Phasenbeschreibung 3PH4W (mit In) 3PH3W 1PH2W (LN); 1PH2W(LL);1PH3W(LLN) 3. Geräteanwendung • Leistungsanalyse • Energiezähler 4. Eingangstyp • Externe Rogowski-Spule • Externer Stromwandler (nur 333 mV) 5. Anzeige 3,5-Zoll-TFT-Bildschirmanzeige 6. Abtastrate 8.000 Abtastungen pro Sekunde 7. Harmonische 52. Max 8. PC-Konnektivität 8. Mechanische Eigenschaften • Gewicht 350 g • Maße L x B x T: 21,5 x 10 x 3,5 cm PQ-Analysator + Mehr wissen Modell KPM PQ Light 1) Produktkomponententyp Mehrphasiger Hand-Leistungsmesser 2) Phasenbeschreibung 3PH4W (mit In) 3PH3W 1PH2W (LN); 1PH2W(LL);1PH3W(LLN) 3. Geräteanwendung • Leistungsanalyse • Energiezähler 4. Eingangstyp • Externe Rogowski-Spule • Externer Stromwandler (nur 333 mV) 5. Anzeige 3,5-Zoll-TFT-Bildschirmanzeige 6. Abtastrate 8.000 Abtastungen pro Sekunde 7. Harmonische 52. Max 8. PC-Konnektivität 8. Mechanische Eigenschaften • Gewicht 350 g • Maße L x B x T: 21,5 x 10 x 3,5 cm Penta PD - Teilentladungsdetektor Mehr wissen Penta PD Teilentladungsdetektor Teilentladungsdetektor Penta-PD ist ein idealer Partner für zustandsbasierte Wartungsprogramme. Teilentladungsdetektor Penta-PD enthält alle 5 Arten von Online-PD-Sensortechnologie. Informationen von mehreren Sensoren verleihen dem Teilentladungsdetektor Penta-PD die Vielseitigkeit, verschiedene Arten von TE in einer Vielzahl von Umspannwerksgeräten zu erkennen. Erkennungsbandbreite 1.TEV - Transiente Erdspannung, Bereich 3 ~ 100 MHz 2.UHF – Ultrahochfrequenz 300MHz~2000 MHz 3.UA – Ultraschall 40 ~ 200 KHz Messbereich 1.UA: -90~80dB 2. TEV: -80 ~ 10 dBm 3. UHF: -80 ~ 10 dBm. Sensor: a) Ultraschallsensor: 20~200 (kHz); b) EV-Sensor (Transient Earth Voltage): 5 ~ 100 MHz; c) UHF-Sensor: 300 ~ 2000 (MHz), mit gerichteter Empfangscharakteristik. Penta PD - Teilentladungsdetektor Mehr wissen Penta PD Teilentladungsdetektor Teilentladungsdetektor Penta-PD ist ein idealer Partner für zustandsbasierte Wartungsprogramme. Teilentladungsdetektor Penta-PD enthält alle 5 Arten von Online-PD-Sensortechnologie. Informationen von mehreren Sensoren verleihen dem Teilentladungsdetektor Penta-PD die Vielseitigkeit, verschiedene Arten von TE in einer Vielzahl von Umspannwerksgeräten zu erkennen. Erkennungsbandbreite 1.TEV - Transiente Erdspannung, Bereich 3 ~ 100 MHz 2.UHF – Ultrahochfrequenz 300MHz~2000 MHz 3.UA – Ultraschall 40 ~ 200 KHz Messbereich 1.UA: -90~80dB 2. TEV: -80 ~ 10 dBm 3. UHF: -80 ~ 10 dBm. Sensor: a) Ultraschallsensor: 20~200 (kHz); b) EV-Sensor (Transient Earth Voltage): 5 ~ 100 MHz; c) UHF-Sensor: 300 ~ 2000 (MHz), mit gerichteter Empfangscharakteristik. PQ-Analysator + Mehr wissen Modell KPM PQ Light 1) Produktkomponententyp Mehrphasiger Hand-Leistungsmesser 2) Phasenbeschreibung 3PH4W (mit In) 3PH3W 1PH2W (LN); 1PH2W(LL);1PH3W(LLN) 3. Geräteanwendung • Leistungsanalyse • Energiezähler 4. Eingangstyp • Externe Rogowski-Spule • Externer Stromwandler (nur 333 mV) 5. Anzeige 3,5-Zoll-TFT-Bildschirmanzeige 6. Abtastrate 8.000 Abtastungen pro Sekunde 7. Harmonische 52. Max 8. PC-Konnektivität 8. Mechanische Eigenschaften • Gewicht 350 g • Maße L x B x T: 21,5 x 10 x 3,5 cm PQ-Analysator + Mehr wissen Modell KPM PQ Light 1) Produktkomponententyp Mehrphasiger Hand-Leistungsmesser 2) Phasenbeschreibung 3PH4W (mit In) 3PH3W 1PH2W (LN); 1PH2W(LL);1PH3W(LLN) 3. Geräteanwendung • Leistungsanalyse • Energiezähler 4. Eingangstyp • Externe Rogowski-Spule • Externer Stromwandler (nur 333 mV) 5. Anzeige 3,5-Zoll-TFT-Bildschirmanzeige 6. Abtastrate 8.000 Abtastungen pro Sekunde 7. Harmonische 52. Max 8. PC-Konnektivität 8. Mechanische Eigenschaften • Gewicht 350 g • Maße L x B x T: 21,5 x 10 x 3,5 cm PQ-Analysator + Mehr wissen Modell KPM PQ Light 1) Produktkomponententyp Mehrphasiger Hand-Leistungsmesser 2) Phasenbeschreibung 3PH4W (mit In) 3PH3W 1PH2W (LN); 1PH2W(LL);1PH3W(LLN) 3. Geräteanwendung • Leistungsanalyse • Energiezähler 4. Eingangstyp • Externe Rogowski-Spule • Externer Stromwandler (nur 333 mV) 5. Anzeige 3,5-Zoll-TFT-Bildschirmanzeige 6. Abtastrate 8.000 Abtastungen pro Sekunde 7. Harmonische 52. Max 8. PC-Konnektivität 8. Mechanische Eigenschaften • Gewicht 350 g • Maße L x B x T: 21,5 x 10 x 3,5 cm Häufig gestellte Fragen (FAQ) FAQ about Monitoring testing : 01 What is the use of online partial discharge (PD) monitoring of panels using TEV and contact ultrasonic methods? Online partial discharge monitoring of medium-voltage and high-voltage panels using TEV (Transient Earth Voltage) and contact ultrasonic methods is used to detect and localize internal insulation defects and surface discharges without shutting down the equipment. Here's how each method contributes: 1. TEV (Transient Earth Voltage) Method Use: Detects internal PD activity, especially within air-insulated switchgear (AIS) and cable terminations inside metal-clad panels. How it works? When PD occurs inside enclosed metal-clad gear, it emits fast-rising electromagnetic pulses that induce transient voltages on the metal surfaces. TEV sensors pick up these signals from outside the panel. Benefit: Non-invasive, detects internal voids, tracking, and corona effects. 2. Contact Ultrasonic Method Use: Detects surface discharges, such as corona or tracking, which emit high-frequency acoustic signals. How it works? A piezoelectric sensor placed on the panel surface detects ultrasonic noise generated by PD activity, even through the enclosure. Benefit: Helps locate poor insulation, loose connections, or contamination issues causing discharge on the surface. Combined Use – Why It Matters? Using both TEV and ultrasonic methods together enhances diagnostic accuracy: TEV gives insight into internal discharge severity and location. Ultrasonic confirms surface or near-surface PD sources and allows cross-verification. This dual-method approach is vital for: Preventive maintenance, Avoiding insulation failures, Improving switchgear reliability, and Extending equipment life without needing shutdowns.
- About Us | KPM Engineering Solutions Pvt. Ltd.|About Us
KPM ENGINEERING SOLUTIONS is electrical test equipment provider with strong support. Our solutions are Relay Test Kit, CT/PT Analyzer, Oil BDV, Tan delta , Circuit Breaker Analyzer, LA Testing,Partial Discharge Test Kit, Thermal Imager Camera, PIK, SIK, AC/DC HIPOT. Visit us @ www.kpmtek.com ÜBER KPM Bei KPM sind wir in den Bereichen Fertigung, Mehrwerthandel und Beratungsdienste tätig. Wir arbeiten mit weltweit führenden Forschungs- und Entwicklungs- und Produktionshäusern auf der ganzen Welt zusammen, um unseren geschätzten Kunden die besten und zuverlässigsten Lösungen vor die Haustür zu bringen. Seit 1992 ist KPM Engineering Solutions ein a führendes Unternehmen in der Elektroberatung und , das sowohl an Führung als auch an Entwicklung beteiligt ist. Wir sind stolz darauf, mit innovativen Ideen, bahnbrechender Technologie und Transparenz den Weg in eine effizientere Zukunft zu weisen. Wir haben an Dutzenden von Projekten mit dem Ziel gearbeitet, innovative technische Lösungen bereitzustellen. Wir sind eine Gruppe von Technokraten mit umfassender Verkaufs- und Anwendungserfahrung sowohl in der Hochspannungs- als auch in der Niederspannungs-Elektro-T & M-Industrie. Als genetisches Beratungsunternehmen für Elektrotechnik bieten wir unseren geschätzten Kunden Design- und Fehlerbehebungsdienste an für die letzten 1,5 Jahrzehnte. Unsere Beratung hat ein breites Kundenspektrum bedient, darunter Industrie, Krankenhäuser, Wohnanlagen, Bildungseinrichtungen, Dammprojekte usw. Bei KPM sind wir bestrebt, unseren Kunden präzise Ausrüstung für die richtige T & M-Anwendung bereitzustellen und dann als erster Ansprechpartner zu fungieren für jede Unterstützung im Zusammenhang mit dem Produkt . Bei Bedarf bietet unsere T&M-Abteilung und unsere Beratungsabteilung Mehrwertdienste wie Ergebnisinterpretation und Ursachenanalyse für DUT-Ausfälle (Device Under Test) an. In Kontakt kommen Our Team. Our team is a fantastic mix of experienced and mid-level professionals who work together like a well-oiled machine. They bring a blend of wisdom and fresh ideas to the table, making them unstoppable as they tackle any challenge that comes their way. S.C.Sharma - Chairperson M.Tech. Elec. HBTI Kanpur , 1985 B.Tech. Elec. MNREC, Allahabad, 1974 S.C Sharma is an experienced electrical engineer with technical consultancy background of 40+ years. His guidance is followed by KPM at policy & administrative level Pankaj Modi - Country Sales Head BE Electrical, Dr. A.P.J. Abdul Kalam Technical University, Lucknow, 2004 Pankaj is a seasoned sales professional with almost 20 years of experience in the testing & measuring equipment , automation, and Industry 4.0, IOT solutions industry. He is managing sales of KPM products at all India level. He is supported by the team of techno-sales engineers Kunal Sharma - Sr Tech. Consultant M.Sc. Electrical, Warsaw University of Technology - Poland , 2024 B.E Electrical, MDU India, 2006 Kunal is a seasoned techno sales professional with 15+ years of experience in sales, application and technical support to power utility customers all across the globe. He was recently granted his M.Sc. with final research thesis on "partial discharge measurement techniques" . Kunal is responsible for customer's technical satisfaction and is supported by the team of techno-sales engineers He is also responsible for KPM's technology tieups all across the globe. KPM Promotes Lifelong Learning: Sr. Consultant Achieves Master's in Electrical Engineering We are delighted to announce that our Sr. Consultant Mr. Kunal Sharma has completed his Master's in Electrical Engineering, with a distinguished project on "Methods for Measurement and Detection of Partial Discharge." from Warsaw University Of Technology , Poland. This significant achievement highlights his dedication and expertise in the field. Anchor 1 UNSERE FACHKOMPETENZ IST IHR VORTEIL
- Products | KPM Engineering Solutions Pvt. Ltd.|Products
KPM Solutions|We are electrical Test Equipment supplier |https://www.kpmtek.com/test-equipment | Relay Test Kits CT/PT Analyzers LA Testers TTR , Transformer Turns Ratio TWRT (Transformer Winding Resistance Tester) Tan delta Partial Discharge Testing ( Portable ) etc POWER SYSTEM PRÜFGERÄTE KPM VIT-100 KPM Vacuum Interrupter Tester KPM ICAL Pro KPM Instrument Calibrator KPM MT 3000 D+ Three phase Reference Standard Energy Meter specially used for energy meter on-site test KPM PSR12 KPM’s Power Signal Recorder 12 KPM TD12 A+ Automatic 12KV Capacitance & Dissipation Factor Test Set KPM TWRT YY 3 Phase Winding Resistance Tester with automatic change of connections Energy Meter Test Benchs 3 phase energy meter test bench for testing energy meters of 0.5 to 0.02 accuracy levels. KPM-SG_70kV, 70mA Cable Testing Surge Generator / Thumper KPM LBVV 240V 110A Battery Discharge Kit (Constant Current , Constant Power) KPM LB4815+ Battery Load Bank , Constant Current, Constant Power , Constant Resistance Mode KPM AL- 80H Battery Pack Air Leak Tester KPM AL- 80L KPM Battery Pack Air Leak Tester KPM CCDB + Series KPM Li Ion Cell Charge Discharge & Balancer KPM CCDB SERIES KPM Li Ion Cell Charge Discharge & Balancer KPM PDH SERIES KPM Pack Discharging (800V / 1000V) KPM PCD Series KPM li Ion Battery Pack Charge Discharge Test kit PCDH Series KPM li Ion Battery Pack Charge Discharge Test kit ( 800V / 1000V ) KPM MCD 2550 KPM charging , discharging & cyclic charging - discharging of Li Ion modules , Constant Current Discharge KPM CCDB 5V 15A KPM Li-ion Cell Charge Discharge Balancing kit, Constant Current Discharge (5V, 15 A) KPM BCD 0550 KPM Li-ion Battery Charging Discharging kit , Constant Current Discharge (5V, 50 A), Used for high current applications like forklifts, cranes etc. KPM BCD 0530 KPM Li-ion Battery Charging Discharging kit (5V, 30A), Constant Current Discharge , Used for high current applications like forklifts, cranes etc. KPM BCD B-4X KPM Li-ion Battery Charging Discharging kit with 4 independent channels (100A), Constant Current Discharge , Used for high current applications like forklifts, cranes etc. KPM KS30 KPM SF6 Gas Analyzer KPM BA-02 Battery Analyzer for testing battery internal resistance, conductance and voltage. Auto increase in the serial number of results using touch and test function, this also reduces testing time KPM Battery Data Logger To check Battery voltage, current and temperature. These sensors are integrated with battery discharge units KPM LA 103 Pro LA Tester measures and displays the values of Total Leakage Current and Third Harmonic Resistive Leakage Current directly with ambient temperature and line harmonic compensation KPM ER1 KPM ER1C is the Three phase Reference Standard Energy Meter specially used to calibrate single phase energy meter on-site . KPM AC HIPOT KPM Cable testing KPM VLF Hipot Tester KPM VLF HIGH VOLTAGE TESTER Hipot Tester KPM DC HIPOT KPM DC Hipot Test Set KPM TD 40 KPM 40kV Tan Delta measurement unit used for cable testing KPM VLF Series KPM VLF series with Tan Delta & PD Measurement Facility KPM Penta Pd pro Hand held Partial Discharge Tester with multichannel PD detection functions which can be integrated with multiple sensors like UHF , TEV, HFCT, AE , Contact Acoustic etc. KPM CEST 1800 KPM’s Clamp Earth & Spike Tester KPM CRT 6002G Contact Resistance Tester with single-end and double-end grounding test technology, It is available in 200A & 600A KPM Onload Tap Changer Analyzer Onload Tap Changer Analyzer is testing key parameters of an OLTC such as ,Transient time, Transition waveform, Transition resistance, Synchronization status of three phase. td12 Automatic 12KV Capacitance & Dissipation Factor Test Set with 4 Nos channels for Bushing testing in one test , Built In 10kV - 5mA Diagnostic Insulation Tester KPM APIK Automatic Primary Injection Kit is used for high voltage switch testing, protection system testing and current transformer testing in power system KPM CTA C+ CT Analyzer ( for factory & field applications ) KPM CT/PT Tester pro An automatic device used for testing of instrument transformers (CTs & PTs) by injection of secondary voltage. This is capable of ratio error , phase error , winding resistance, knee point upto 2kV etc. K3063i 6I & 4U - Automatic Relay Test Kit RTK(KPM KFA 300) The Lightest Relay Test Kit with 3 Current Sources & 4 voltage sources . Builtin software with AC Test , DC Test , Frequency Test , Distance Test , Harmonic Test Modules RTK(K316i) Automatic Relay Test Kit ( 6I,4U) KPM-DPM-01 KPM Dew Point Meter K68i Relay test kit 3I & 4U - Automatic Relay Test Kit RTK KPM KF 86P Automatic Relay Test Kit with 6 current and 6 voltages , with advanced software with RIO / XRIO Import function KPM CT/PT analyzer It tests all type of CT/PT as per IEC standards (deal tool for CT/PT Manufacturers & Utility Customers) KPM CT:PT Tester KPM CT PT Testing , Primary Current Method CT PT PRO KPM CT PT Tester , Voltage Ratio Method KPM CT/PT HVCTR High Voltage Current Transformer Ratio Tester measures Key CT parameters of upto 33KV system KPM CT/PT PIK For testing Current Transformer , Circuit Breakers etc. by injecting current in Primary side of CT. Moduler design for transporting easily KPM TD12 KPM 12kV Tan delta Tester / Dissipation Tester KPM TTR3 On-site measurement of DC resistance of transformer or motors (High Current Source of 20 A) KPM SFRA 01 Sweep Frequency Response Analysis Test Set (SFRA) for checking the core and winding integrity of a power transformer KPM TWRT Series On-site measurement of DC resistance of transformer (High Current Source of 20 A) KPM 5KP 5 KV Diagnostic Insulation Tester KPM 5KP+ IR Tester ( 5KV, 10KV, 15KV, 20KV) TPL-Trans Power Loss Tester KPM Transformer Power Loss Analyzer OLTC Analyzer KPM Online Tap Changer Tester KPM CB Analyzer KPM Circuit Breaker Analyzer KPM CBA 01 KPM Circuit Breaker Tester KPM CRT Contact Resistance Tester CBT-01 KPM Circuit Breaker Timer VILA KPM Vacuum Interrupter Life Analyzer KPM Oil BDV 100+ KPM Oil Breakdown Voltage Test Kit KPM Oil BDV 100 A+ KPM Oil Breakdown Voltage Test Kit with variable rate of rise voltage KPM OT-01 CC KPM Flash Point Tester Close Cup KPM OT-01 OC KPM Flash Point Tester Open cup KPM OT 02 KPM Karl Fischer Tester , Moisture in oil tester KPM OT O3 KPM Viscosity Tester KPM OT-05 KPM Oil Acid Value Tester KPM OT01 KPM Oil Tan Delta Furan Tester KPM FT-01 KPM HPLC , Furan Tester KPM IPT 01 KPM Imputiry Particle Tester KPM PCM 01 KPM Petroleum Colorimeter KPM ODT 01 KPM Oil Density Tester KPM Interfacial Tension Meter KPM Interfacial Tension Meter KPM-OPPT-01 KPM Oil Pour Point Tester KPM PDTI Monitor KPM Online Partial Discharge Monitor with Temperature & Sht. Ckt Current for HV Cable terminations KPM PDM-01 KPM Partial Discharge Monitor KPM Duo PD KPM online Partial Discharge Tester with acoustic and TEV sensors KPM PD Pulse-8 KPM Online PD Tester for PD Monitoring of switchgears and Ring Main Units KPM PDA-01 KPM Partial Discharge Analyzer , electrical method KPM Penta PD KPM Hand Held partial discharge Tester with TEV , HFCT, AE , Contact Acoustic, UHF sensors KPM CORONA POINTER KPM PD Pointer for laboratory corona finding KPM PQA+ KPM Power Quality Analyzer and recorder KPM - PQ Analyzer Light KPM Power Quality Analyzer and recorder KPM LA 100 + , LA TESTER KPM LA Tester / Surge arrester Tester / MOA Tester / 3rd harmonic leakage current tester kpm la 103+ KPM LA Tester / Surge arrester Tester / MOA Tester / 3rd harmonic leakage current tester KPM MT 3000 D 3-Phase energy meter tester KPM SF6 DPM Light KPM SF6 Dew Point Meter KPM CTTC KPM CT Heat Run Test Device KPM CEST KPM Clamp Earth Spike Tester KPM CET 1200 KPM Clamp Earth Tester KPM ET30K KPM Earth Tester with Spikes KPM GERM KPM Online Grid Earth Resistance Monitor KPM CM-0524 KPM Cell Voltage Monitor for Li Ion Batteries KPM battery load bank KPM DC Load Bank , KPM Battery Discharge Kit , KPM Constant Current DC load banks
- PD - Projects | KPM Engineering Solutions Pvt. Ltd.|PD - Projects
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD - Projects |https://kpmtek.wixsite.com/website/de/pd-projects Teilentladungsprojekte Generating Sets at QEC, Vietnam PD & VW Test System for Surge Arrester at Siemens, China 15kVA/120kV PD & VW Test for Instrument Transformer at Xishang Electric 10kVA-120kV VW test for Electric Components at Hangzhou Yunuo Technology Shielding Room of PD and VW test for Switch Cabinet at Pinggao Electric Group Power Transfomer Comprehensive Tests for Power Transformer at Ningbo Gerace Electric 5kVA/150kV Digital PD test for 35kV Switch Cabinet at China Energy Engineering Group Partial Discharge Equipment for 35kV Dry type Power Transformer at Dongmeng Electric Partial Discharge Shielding Room for Power Transformer PD test at Dongfang Electronics Co., Ltd. 50kVA/50kV Power Frequency Voltage WIthstanding Test for Various Electrical Equipment at Shanghai El 150kV Partial Discharge & Voltage Withstanding Test for Switch Cabinet at ABB, China
- PD Calibrator | KPM India |PD Calibrator
KPM India |We are electrical test equipment manufacturers, We deal in CT PT Analyzer, Relay Test Kit , Tan delta , Transformer Test Kits , LA Testers etc.|PD Calibrator |https://kpmtek.wixsite.com/website/de/pdcalibrator PD-Kalibrator
- Earth Testing | KPM Engineering Solutions Pvt. Ltd.|Earth Testing
In KPM Engineering Solutions we have all type of state of art earth resistance testers such as Spike Method , Clamp On Method , Grid Earth Resistance Monitor Etc. |Earth Testing |https://www.kpmtek.com/earth-testing-app ERD-/BODENPRÜFUNG Earth Tester - Spike-Methode Mehr wissen Earth Tester (Spike Method) KPM -ET30K Earth Resistance & Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage &_cc781905-5cde-3194-bb3b- 136bad5cf58d_Wechselspannung. ET30K adopts the latest technology for precise 4-pole, 3 -pole and simple 2-pole measurement for earth Widerstand. importing FFT and AFC technology,_cc781905-5cde- 3194-bb3b-136bad5cf58d_ with a unique function of anti-interference capability and the ability to adapt to the_cc781905-5cde-3194- bb3b-136bad5cf58d_ environment, consistency of repeat testing,_cc781905-5cde-3194-bb3b -136bad5cf58d_ um hohe Präzision, hohe Stabilität und Zuverlässigkeit für längere Messungen zu gewährleisten Erdungsprüfer – Klemmmethode Mehr wissen Clamp Earth Tester (KPM-CET1200) ist weit verbreitet in der Erdungswiderstandsmessung, Loop Widerstandsmessung in Bereichen wie Elektro Widerstandsmessung in Bereichen wie Elektro Meteorologie, Telekommunikation_Energie , Ölfeld, Architektur und industrielle elektrische Ausrüstung usw. Beim Messen des Erdungssystems mit Schleife gibt es keine Notwendigkeit, die Erdung zu trennen Draht ohne Hilfs Elektrode, was sicherer und schneller bedeutet. Schlüsselspezifikationen von Clamp Earth Tester (KPM-CET1200) Misst den Erdwiderstand/Schleifenwiderstand Große Backengröße (65 mm x 32 mm) Großer Widerstandsmessbereich (0,01 Ω bis 1200 Ω) Großer Strommessbereich (0,01 A bis 20 A) Ideal zum Testen von miteinander verbundenen Erdgrubenschaltungen like Grid Earthing, Mesh Earthing, Transmission Tower Earthing Earth Tester - Spike-Methode Mehr wissen Earth Tester (Spike Method) KPM -ET30K Earth Resistance & Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage &_cc781905-5cde-3194-bb3b- 136bad5cf58d_Wechselspannung. ET30K adopts the latest technology for precise 4-pole, 3 -pole and simple 2-pole measurement for earth Widerstand. importing FFT and AFC technology,_cc781905-5cde- 3194-bb3b-136bad5cf58d_ with a unique function of anti-interference capability and the ability to adapt to the_cc781905-5cde-3194- bb3b-136bad5cf58d_ environment, consistency of repeat testing,_cc781905-5cde-3194-bb3b -136bad5cf58d_ um hohe Präzision, hohe Stabilität und Zuverlässigkeit für längere Messungen zu gewährleisten Online Earth Tester (GERM) Mehr wissen Ein hochmodernes Gerät zur Online-Überwachung des Zustands Ihres kritischen Erdungssystems Grid Earth Resistance Monitor (Germ) ist ein state of Art Gerät, das Online den Erdwiderstandswert der Erdgruben in Echtzeit überwacht und einen Alarm auslöst, wenn es einen Fehler erkennt . Alle Informationen von der Website werden über fortgeschrittene Kommunikationsmethoden sicher an den Server gesendet. Häufig gestellte Fragen (FAQ) FAQ about Earth testing : 01 Difference between Clamp and Spike Method? Earth Resistance Testing: Clamp vs. Spike Method : The Clamp Method and the Spike (Fall-of-Potential) Method are two commonly used techniques for measuring earth resistance, each with distinct use cases. The Spike Method (also known as the three-point or fall-of-potential method) is considered the most accurate and is typically used during installation or scheduled maintenance when it’s feasible to disconnect the grounding system. It requires driving two auxiliary spikes into the ground at set distances from the earth electrode and measuring the voltage drop created by a test current. This method provides a true earth resistance value but is time-consuming, invasive, and requires open ground access. In contrast, the Clamp Method (or Stakeless method) is a quick, non-intrusive test ideal for live systems where disconnecting the earth rod is not possible. Using a special clamp meter, the method induces a test signal and measures current flow through parallel earth paths. It’s convenient and fast but is only applicable when multiple grounding paths exist (e.g., in mesh or grid systems). The Clamp Method does not provide accurate results for isolated earth rods or when there is only a single grounding point. In summary, the Spike Method is best for accurate baseline testing during commissioning, while the Clamp Method is ideal for routine checks on operational systems without disrupting service. 02 How to Ensure Compliance With Earth Testing in Renewable Sites? Ensuring Compliance with Earth Testing in Renewable Sites : To ensure safety and meet regulatory standards in solar, wind, or hybrid renewable energy systems, proper earth resistance testing is essential. Key Steps: Follow Standards: Comply with IEC 60364, IEEE 80, BS 7430, or local codes. Test Soil Early: Conduct soil resistivity surveys during design to select the right grounding method. Use Proper Methods: Apply the Fall-of-Potential method for commissioning and Clamp Method for periodic checks. Keep Records: Log all test data with method, instrument, and environmental details. Test Regularly: Schedule annual or biannual resistance tests to catch degradation early. Use Remote Monitoring (if available): SCADA or sensors can track resistance levels continuously. Train Personnel: Ensure field staff know correct testing procedures and safety protocols. Third-Party Verification: For audits or large projects, use certified inspectors for compliance reporting. 03 What will be seasonal Impact on Ground Resistance Measurements? Seasonal Impact on Ground Resistance Measurements Ground resistance values can vary significantly with seasonal changes due to environmental factors affecting soil conditions: Soil Moisture: During wet seasons (rainy or winter), soil moisture increases, lowering ground resistance by improving conductivity. Conversely, dry seasons cause soil to dry out, increasing resistance. Soil Temperature: Colder temperatures can increase soil resistivity as water in soil may freeze, reducing conductivity. Warmer temperatures generally improve conductivity. Soil Composition Changes: Seasonal changes in organic matter decomposition and salt concentration may also affect soil resistivity. Vegetation and Ground Cover: Plant growth during certain seasons can affect soil moisture retention and contact with grounding electrodes. Implications Testing during different seasons may yield varying results; hence, baseline measurements should be taken in both dry and wet conditions to understand worst-case scenarios. For accurate monitoring and compliance, schedule tests consistently or adjust acceptable resistance thresholds based on seasonal variation.